ACE3/addons/common/functions/fnc_readSettingsFromParamsArray.sqf

68 lines
2.5 KiB
Plaintext
Raw Normal View History

/*
* Author: PabstMirror
* Read settins from paramsArray that have a ACE_setting = 1.
* Happens before modules but after all other configs (for force priority)
*
* Arguments:
* None
*
* Return Value:
* None
*
* Example:
* [] call ace_common_fnc_readSettingsFromParamsArray
*
* Public: No
*/
#define DEBUG_MODE_FULL
#include "script_component.hpp"
//paramsArray is a normal variable not a command
private _paramsArray = missionnamespace getVariable ["paramsArray", []];
TRACE_1("Reading missionConfigFile params",_paramsArray);
{
2015-11-17 20:02:20 +00:00
private _config = (missionConfigFile >> "params") select _forEachIndex;
if ((getNumber (_config >> "ACE_setting")) > 0) then {
2015-11-17 20:02:20 +00:00
private _settingName = configName _config;
private _settingValue = _x;
private _title = getText (_config >> "title");
2015-11-08 17:22:41 +00:00
TRACE_3("ace_setting",_title,_settingName,_settingValue);
// Check if the variable is already defined
if (isNil _settingName) exitWith {
ERROR_1("readSettingsFromParamsArray - param [%1] is not an ace_setting", _settingName);
};
// The setting is not forced, so update the value
// Read entry and cast it to the correct type from the existing variable
(cba_settings_default getVariable [_settingName, []]) params ["", "", ["_settingType", ""]];
2015-11-17 20:02:20 +00:00
private _validValue = false;
2015-11-07 02:53:05 +00:00
switch (true) do {
case (_settingType == "LIST");
case (_settingType == "SCALAR"): {
_validValue = [_settingName, _settingValue] call CBA_settings_fnc_check;
};
case (_settingType == "CHECKBOX"): {
_settingValue = _settingValue > 0;
_validValue = [_settingName, _settingValue] call CBA_settings_fnc_check;
};
// Will not Handle ARRAY,COLOR,STRING??? (bool/scalar covers most important settings)
};
if (!_validValue) exitWith {
WARNING_3("readSettingsFromParamsArray - param [%1] type not valid [%2] - expected type [%3]", _settingName,_settingValue,_settingType);
};
if ([_settingName, "mission"] call CBA_settings_fnc_isForced) then {
WARNING_1("Setting [%1] - Already Forced",_settingName);
};
// Set the setting as a mission setting and force it
private _return = ["CBA_settings_setSettingMission", [_settingName, _settingValue, true]] call CBA_fnc_localEvent;
TRACE_3("setSettingMission from paramsArray",_settingName,_settingValue,_return);
};
2015-11-30 16:23:48 +00:00
} forEach _paramsArray;