mirror of
https://github.com/acemod/ACE3.git
synced 2024-08-30 18:23:18 +00:00
6ea0312770
* open bolt and spare barrel cooling boost * change magic number to macro
73 lines
2.6 KiB
Plaintext
73 lines
2.6 KiB
Plaintext
#include "..\script_component.hpp"
|
|
/*
|
|
* Author: esteldunedain
|
|
* Calculate the cooling down of a weapon over a time interval.
|
|
*
|
|
* Arguments:
|
|
* 0: Initial temperature <NUMBER>
|
|
* 1: Barrel mass <NUMBER>
|
|
* 2: Time interval <NUMBER>
|
|
* 3: Bolt type <NUMBER>
|
|
*
|
|
* Return Value:
|
|
* Final temperature <NUMBER>
|
|
*
|
|
* Example:
|
|
* [_temperature, _barrelMass, _totalTime] call ace_overheating_fnc_calculateCooling
|
|
*
|
|
* Public: No
|
|
*/
|
|
|
|
params ["_temperature", "_barrelMass", "_totalTime", "_boltType"];
|
|
|
|
// The lowest temperature a weapon can reach is the ambient air temperature.
|
|
private _ambientTemperature = ambientTemperature select 0;
|
|
|
|
// If a long time passed since the last shot, there's no need to calculate anything; the weapon should be cool
|
|
if (_totalTime > 1800) exitWith {_ambientTemperature};
|
|
if (_temperature <= _ambientTemperature) exitWith {_ambientTemperature};
|
|
|
|
//AR-15 (0.00570m bullet diameter) (barrel diameter usually 0.75" or 0.008255m radius)
|
|
//Steel Denisty = 7850 m^3 / kg
|
|
//Area of a cylinder (2/r)*(Pi * r^3 + V) - for a 0.008255m radius barrel -> Area = 210(1/meters) * Volume
|
|
//Adjusted volume for being hollowed out is ~1.1x
|
|
//So Area = 210 * 1.1 * (mass / 7850) = mass * 0.029427 (for steel near that diameter)
|
|
|
|
private _barrelSurface = _barrelMass * 0.029427;
|
|
private _convectionRate = 25;
|
|
|
|
//provide additional cooling if swimming or raining or windy
|
|
if (ACE_player call EFUNC(common,isSwimming)) then {
|
|
_convectionRate = 500;
|
|
} else {
|
|
// this will give a convection rate between 25 (no wind or rain) and 125 (max rain and >=50 m/s wind)
|
|
_convectionRate = _convectionRate * ((linearConversion [0,1,rain,1,5,true] + (5 min (vectorMagnitude wind / 10))) / 2);
|
|
};
|
|
|
|
//Increase convection cooling for open bolt type guns
|
|
if (_boltType == 0) then {_convectionRate = _convectionRate * OPEN_BOLT_ADDITIONAL_CONVECTION};
|
|
|
|
TRACE_4("cooling",_temperature,_totalTime,_barrelMass,_barrelSurface);
|
|
|
|
private _time = 0;
|
|
while {true} do {
|
|
private _deltaTime = (_totalTime - _time) min 20;
|
|
|
|
_temperature = _temperature - (
|
|
// Convective cooling
|
|
_convectionRate * _barrelSurface * _temperature
|
|
// Radiative cooling
|
|
+ 0.4 * 5.67e-8 * _barrelSurface * ((_temperature + 273.15) ^ 4 - 273.15 ^ 4)
|
|
) * GVAR(coolingCoef) * _deltaTime / (_barrelMass * 466);
|
|
|
|
if (_temperature <= _ambientTemperature) exitWith {_ambientTemperature};
|
|
|
|
if (isNil "_temperature") exitWith {
|
|
diag_log text format ["[ACE] ERROR: _totalTime = %1; _time = %2; _deltaTime = %3;", _totalTime, _time, _deltaTime];
|
|
0
|
|
};
|
|
|
|
_time = _time + _deltaTime;
|
|
if (_time >= _totalTime) exitWith {_temperature max _ambientTemperature};
|
|
};
|