* fn_getBloodVolumeChange.sqf
* @Descr: Calculates the blood volume change and decreases the IVs given to the unit.
* @Author: Glowbal
*
* @Arguments: []
* @Return: NUMBER Bloodvolume change
* @PublicAPI: false
*/
#include "script_component.hpp"
/*
IV Change per second calculation:
250ml should take 60 seconds to fill. 250/60 = 4.166.
*/
#define IV_CHANGE_PER_SECOND -4.166
/*
Blood Change per second calculation for IVs:
250ml should take 60 seconds to fill in. Total blood volume is 7000ml = 100%.
7000/100 = 70 = 1%
250 / 70 = 3.571428571%
3.571428571 / 60 = 0.0595% per second.
*/
#define BLOOD_CHANGE_PER_SECOND 0.0595
private ["_unit","_bloodVolume","_bloodVolumeChange", "_ivVolume"];
_unit = _this select 0;
_bloodVolume = _unit getvariable [QGVAR(bloodVolume), 100];
_bloodVolumeChange = -(_unit call FUNC(getBloodLoss));
if (_bloodVolume < 100.0) then {
if ((_unit getvariable [QGVAR(salineIVVolume), 0]) > 0) then {
_bloodVolumeChange = _bloodVolumeChange + BLOOD_CHANGE_PER_SECOND;
_ivVolume = (_unit getvariable [QGVAR(salineIVVolume), 0]) + IV_CHANGE_PER_SECOND;
_unit setvariable [QGVAR(salineIVVolume),_ivVolume];
if ([QEGVAR(fieldRations,module)] call EFUNC(common,isModuleEnabled_F)) then {
if ([_unit] call EFUNC(fieldRations,canDrink)) then {
_unit setvariable [QEGVAR(fieldRations,drinkStatus), (_unit getvariable [QEGVAR(fieldRations,drinkStatus), 100]) + 0.2];
};
};
};
if ((_unit getvariable [QGVAR(plasmaIVVolume), 0]) > 0) then {
_bloodVolumeChange = _bloodVolumeChange + BLOOD_CHANGE_PER_SECOND;
_ivVolume = (_unit getvariable [QGVAR(plasmaIVVolume), 0]) + IV_CHANGE_PER_SECOND;
_unit setvariable [QGVAR(plasmaIVVolume),_ivVolume];
};
if ((_unit getvariable [QGVAR(bloodIVVolume), 0]) > 0) then {
_bloodVolumeChange = _bloodVolumeChange + BLOOD_CHANGE_PER_SECOND;
_ivVolume = (_unit getvariable [QGVAR(bloodIVVolume), 0]) + IV_CHANGE_PER_SECOND;
_unit setvariable [QGVAR(bloodIVVolume),_ivVolume];
};
};
_bloodVolumeChange