ACE3/addons/medical/functions/fnc_getBloodPressure.sqf

32 lines
960 B
Plaintext

/*
* Author: Glowbal
* Calculates the blood volume change and decreases the IVs given to the unit.
*
* Arguments:
* 0: The Unit <OBJECT>
*
* ReturnValue:
* 0: BloodPressure Low <NUMBER>
* 1: BloodPressure High <NUMBER>
*
* Public: No
*/
#include "script_component.hpp"
// Value is taken because with cardic output and resistance at default values, it will put blood pressure High at 120.
#define MODIFIER_BP_HIGH 0.229
// Value is taken because with cardic output and resistance at default values, it will put blood pressure Low at 80.
#define MODIFIER_BP_LOW 0.1524
params ["_unit"];
private _cardiacOutput = [_unit] call FUNC(getCardiacOutput);
private _resistance = _unit getVariable [QGVAR(peripheralResistance), 100];
private _bloodPressureHigh = (_cardiacOutput * MODIFIER_BP_HIGH) * _resistance;
private _bloodPressureLow = (_cardiacOutput * MODIFIER_BP_LOW) * _resistance;
[_bloodPressureLow max 0, _bloodPressureHigh max 0]