ACE3/addons/refuel/initSettings.sqf
Samuel Deutsch edf4a70ed6
Refuel - Added ability to refuel fuel sources (#8981)
* Simplify main fuel loop

* Remove unecessary action macro

* Add container refueling

* Fuel counter behaviour is now consistent for both limited and unlimited fuel sources

* Update maxFuel and refuelContainer whenever fueling begins

* Update maxFuel and refuelContainer whenever fueling begins

* Prevent loading of fuel sources into cargo when they have a nozzle connected to them

* Added action to check how much fuel is left in a jerry can

* Prevent jerry cans from being picked up if they have a nozzle connected to them

* Added function to check if a nozzle can be connected to an object

* Prevent fuel sources which have their nozzle deployed from being loaded

* Compute both tank volumes inside of refuel instead of durring turn on

* Didn't mean to delete these

* Allow for user defined fuel capacities

* Handle more edge cases with infinite fuel sources

* Refuel - Prevent fuel sources from being dragged while they're refueling other things

* Refuel - Added flow rate multiplier for refueling fuel sources

* Refuel - Use FUNC instead of DFUNC for nozzle actions

* Refuel - getCapacity should return REFUEL_DISABLED_FUEL instead of 0 when argument is not a fuel source

* Refuel - Correctly reset fuel counter when fueling a new target

* Refuel - Implemented all suggested changes

* Refuel - Added newlines to end of files

* Refuel - Added missing newline at end of XEH_PREP

* Only setFuel once per jerry can creation

Co-authored-by: PabstMirror <pabstmirror@gmail.com>

* Calling getFuel will initialize the fuel source

* Refuel - Add newline to end of file

---------

Co-authored-by: BaerMitUmlaut <baermitumlaut@users.noreply.github.com>
Co-authored-by: PabstMirror <pabstmirror@gmail.com>
2023-02-16 20:06:11 -06:00

36 lines
1.6 KiB
Plaintext

[
QGVAR(rate), "SLIDER",
[LSTRING(RefuelSettings_speed_DisplayName), LSTRING(RefuelSettings_speed_Description)],
[localize ELSTRING(OptionsMenu,CategoryLogistics), localize "str_state_refuel"],
[0,25,1,1], // [min, max, default value, trailing decimals (-1 for whole numbers only)]
true, // isGlobal
{[QGVAR(rate), _this] call EFUNC(common,cbaSettings_settingChanged)}
] call CBA_fnc_addSetting;
[
QGVAR(cargoRate), "SLIDER",
[LSTRING(RefuelSettings_speedCargo_DisplayName), LSTRING(RefuelSettings_speedCargo_Description)],
[localize ELSTRING(OptionsMenu,CategoryLogistics), localize "str_state_refuel"],
[0,250,10,1], // [min, max, default value, trailing decimals (-1 for whole numbers only)]
true, // isGlobal
{[QGVAR(cargoRate), _this] call EFUNC(common,cbaSettings_settingChanged)}
] call CBA_fnc_addSetting;
[
QGVAR(hoseLength), "SLIDER",
[LSTRING(RefuelSettings_hoseLength_DisplayName)],
[localize ELSTRING(OptionsMenu,CategoryLogistics), localize "str_state_refuel"],
[0,50,12,1], // [min, max, default value, trailing decimals (-1 for whole numbers only)]
true, // isGlobal
{[QGVAR(hoseLength), _this] call EFUNC(common,cbaSettings_settingChanged)}
] call CBA_fnc_addSetting;
[
QGVAR(progressDuration), "TIME",
[LSTRING(RefuelSettings_progressDuration_DisplayName), LSTRING(RefuelSettings_progressDuration_Description)],
[localize ELSTRING(OptionsMenu,CategoryLogistics), localize "str_state_refuel"],
[0, 10, 2], // [min, max, default value]
true, // isGlobal
{[QGVAR(progressDuration), _this] call EFUNC(common,cbaSettings_settingChanged)}
] call CBA_fnc_addSetting;