-- Data Bus - Central Communication Linking for Supervisor Front Panel
--
local psil = require("scada-common.psil")
local util = require("scada-common.util")
2023-05-05 17:04:13 +00:00
local pgi = require("supervisor.panel.pgi")
-- nominal RTT is ping (0ms to 10ms usually) + 150ms for SV main loop tick
local WARN_RTT = 300 -- 2x as long as expected w/ 0 ping
local HIGH_RTT = 500 -- 3.33x as long as expected w/ 0 ping
2023-05-05 17:04:13 +00:00
local databus = {}
-- databus PSIL
databus.ps = psil.create()
2023-05-05 17:04:13 +00:00
-- call to toggle heartbeat signal
function databus.heartbeat() databus.ps.toggle("heartbeat") end
2023-05-05 17:04:13 +00:00
-- transmit firmware versions across the bus
2023-06-03 21:31:06 +00:00
---@param sv_v string supervisor version
2023-05-05 17:04:13 +00:00
---@param comms_v string comms version
2023-06-03 21:31:06 +00:00
function databus.tx_versions(sv_v, comms_v)
databus.ps.publish("version", sv_v)
databus.ps.publish("comms_version", comms_v)
2023-05-05 17:04:13 +00:00
end
-- transmit hardware status for modem connection state
---@param has_modem boolean
function databus.tx_hw_modem(has_modem)
databus.ps.publish("has_modem", has_modem)
end
-- transmit PLC firmware version and session connection state
---@param reactor_id integer reactor unit ID
---@param fw string firmware version
---@param s_addr integer PLC computer ID
function databus.tx_plc_connected(reactor_id, fw, s_addr)
databus.ps.publish("plc_" .. reactor_id .. "_fw", fw)
databus.ps.publish("plc_" .. reactor_id .. "_conn", true)
databus.ps.publish("plc_" .. reactor_id .. "_addr", util.sprintf("@% 4d", s_addr))
2023-05-05 17:04:13 +00:00
end
2023-06-03 21:31:06 +00:00
-- transmit PLC disconnected
---@param reactor_id integer reactor unit ID
function databus.tx_plc_disconnected(reactor_id)
databus.ps.publish("plc_" .. reactor_id .. "_fw", " ------- ")
databus.ps.publish("plc_" .. reactor_id .. "_conn", false)
databus.ps.publish("plc_" .. reactor_id .. "_addr", " --- ")
databus.ps.publish("plc_" .. reactor_id .. "_rtt", 0)
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.lightGray)
end
-- transmit PLC session RTT
---@param reactor_id integer reactor unit ID
---@param rtt integer round trip time
function databus.tx_plc_rtt(reactor_id, rtt)
databus.ps.publish("plc_" .. reactor_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.green_hc)
end
2023-05-05 17:04:13 +00:00
end
-- transmit RTU firmware version and session connection state
---@param session_id integer RTU session
---@param fw string firmware version
---@param s_addr integer RTU computer ID
function databus.tx_rtu_connected(session_id, fw, s_addr)
databus.ps.publish("rtu_" .. session_id .. "_fw", fw)
databus.ps.publish("rtu_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr))
pgi.create_rtu_entry(session_id)
end
-- transmit RTU disconnected
---@param session_id integer RTU session
function databus.tx_rtu_disconnected(session_id)
pgi.delete_rtu_entry(session_id)
end
-- transmit RTU session RTT
---@param session_id integer RTU session
---@param rtt integer round trip time
function databus.tx_rtu_rtt(session_id, rtt)
databus.ps.publish("rtu_" .. session_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.green_hc)
end
end
-- transmit RTU session unit count
---@param session_id integer RTU session
---@param units integer unit count
function databus.tx_rtu_units(session_id, units)
databus.ps.publish("rtu_" .. session_id .. "_units", units)
end
-- transmit coordinator firmware version and session connection state
---@param fw string firmware version
---@param s_addr integer coordinator computer ID
function databus.tx_crd_connected(fw, s_addr)
databus.ps.publish("crd_fw", fw)
databus.ps.publish("crd_conn", true)
databus.ps.publish("crd_addr", tostring(s_addr))
end
2023-06-03 21:31:06 +00:00
-- transmit coordinator disconnected
function databus.tx_crd_disconnected()
databus.ps.publish("crd_fw", " ------- ")
databus.ps.publish("crd_conn", false)
databus.ps.publish("crd_addr", "---")
databus.ps.publish("crd_rtt", 0)
databus.ps.publish("crd_rtt_color", colors.lightGray)
end
-- transmit coordinator session RTT
---@param rtt integer round trip time
function databus.tx_crd_rtt(rtt)
databus.ps.publish("crd_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("crd_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("crd_rtt_color", colors.yellow_hc)
else
databus.ps.publish("crd_rtt_color", colors.green_hc)
end
2023-05-05 17:04:13 +00:00
end
2023-06-03 21:31:06 +00:00
-- transmit PKT firmware version and PDG session connection state
---@param session_id integer PDG session
---@param fw string firmware version
---@param s_addr integer PDG computer ID
function databus.tx_pdg_connected(session_id, fw, s_addr)
databus.ps.publish("pdg_" .. session_id .. "_fw", fw)
databus.ps.publish("pdg_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr))
pgi.create_pdg_entry(session_id)
end
2023-06-03 21:31:06 +00:00
-- transmit PDG session disconnected
---@param session_id integer PDG session
function databus.tx_pdg_disconnected(session_id)
pgi.delete_pdg_entry(session_id)
end
-- transmit PDG session RTT
---@param session_id integer PDG session
---@param rtt integer round trip time
function databus.tx_pdg_rtt(session_id, rtt)
databus.ps.publish("pdg_" .. session_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.green_hc)
end
end
2023-05-05 17:04:13 +00:00
-- link a function to receive data from the bus
---@param field string field name
---@param func function function to link
function databus.rx_field(field, func)
databus.ps.subscribe(field, func)
2023-05-05 17:04:13 +00:00
end
return databus