2022-01-14 21:33:09 +00:00
|
|
|
--
|
|
|
|
-- Reactor Programmable Logic Controller
|
|
|
|
--
|
|
|
|
|
|
|
|
os.loadAPI("scada-common/util.lua")
|
|
|
|
os.loadAPI("scada-common/comms.lua")
|
|
|
|
os.loadAPI("reactor-plc/config.lua")
|
|
|
|
os.loadAPI("reactor-plc/plc.lua")
|
|
|
|
|
|
|
|
local R_PLC_VERSION = "alpha-v0.1"
|
|
|
|
|
|
|
|
local print_ts = util.print_ts
|
|
|
|
|
|
|
|
local reactor = peripheral.find("fissionReactor")
|
|
|
|
local modem = peripheral.find("modem")
|
|
|
|
|
|
|
|
print(">> Reactor PLC " .. R_PLC_VERSION .. " <<")
|
|
|
|
|
|
|
|
-- we need a reactor and a modem
|
|
|
|
if reactor == nil then
|
|
|
|
print("Fission reactor not found, exiting...");
|
|
|
|
return
|
|
|
|
elseif modem == nil then
|
|
|
|
print("No modem found, disabling reactor and exiting...")
|
|
|
|
reactor.scram()
|
|
|
|
return
|
|
|
|
end
|
|
|
|
|
|
|
|
-- just booting up, no fission allowed (neutrons stay put thanks)
|
|
|
|
reactor.scram()
|
|
|
|
|
|
|
|
-- init internal safety system
|
|
|
|
local iss = plc.iss_init(reactor)
|
|
|
|
|
|
|
|
-- start comms
|
|
|
|
if not modem.isOpen(config.LISTEN_PORT) then
|
|
|
|
modem.open(config.LISTEN_PORT)
|
|
|
|
end
|
|
|
|
|
|
|
|
local comms = comms.rplc_comms(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor)
|
|
|
|
|
|
|
|
-- attempt server connection
|
|
|
|
-- exits application if connection is denied
|
|
|
|
plc.scada_link(comms)
|
|
|
|
|
|
|
|
-- comms watchdog, 3 second timeout
|
|
|
|
local conn_watchdog = watchdog.new_watchdog(3)
|
|
|
|
|
|
|
|
-- loop clock (10Hz, 2 ticks)
|
|
|
|
-- send status updates at 4Hz (every 5 ticks)
|
|
|
|
local loop_tick = os.startTimer(0.05)
|
|
|
|
local ticks_to_update = 5
|
|
|
|
|
|
|
|
-- event loop
|
|
|
|
while true do
|
|
|
|
local event, param1, param2, param3, param4, param5 = os.pullEvent()
|
|
|
|
|
|
|
|
-- check safety (SCRAM occurs if tripped)
|
|
|
|
local iss_status, iss_tripped = iss.check()
|
|
|
|
|
|
|
|
-- handle event
|
|
|
|
if event == "timer" and param1 == loop_tick then
|
|
|
|
-- basic event tick, send updated data if it is time
|
|
|
|
ticks_to_update = ticks_to_update - 1
|
|
|
|
if ticks_to_update == 0 then
|
|
|
|
ticks_to_update = 5
|
|
|
|
end
|
|
|
|
elseif event == "modem_message" then
|
|
|
|
-- got a packet
|
|
|
|
-- feed the watchdog first so it doesn't eat our packets
|
|
|
|
conn_watchdog.feed()
|
|
|
|
|
|
|
|
elseif event == "timer" and param1 == conn_watchdog.get_timer() then
|
|
|
|
-- haven't heard from server recently? shutdown
|
|
|
|
reactor.scram()
|
|
|
|
print_ts("[alert] server timeout, reactor disabled\n")
|
|
|
|
end
|
2022-01-02 00:45:33 +00:00
|
|
|
end
|