mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#231 renamed unit a_ functions to auto_
This commit is contained in:
parent
351842c9a1
commit
0b939be412
@ -128,7 +128,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
for i = 1, #self.prio_defs do
|
||||
local units = self.prio_defs[i]
|
||||
for u = 1, #units do
|
||||
all_ramped = all_ramped and units[u].a_ramp_complete()
|
||||
all_ramped = all_ramped and units[u].auto_ramp_complete()
|
||||
end
|
||||
end
|
||||
|
||||
@ -159,7 +159,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
local u = units[id] ---@type reactor_unit
|
||||
|
||||
local ctl = u.get_control_inf()
|
||||
local lim_br100 = u.a_get_effective_limit()
|
||||
local lim_br100 = u.auto_get_effective_limit()
|
||||
|
||||
if abort_on_fault and (lim_br100 ~= ctl.lim_br100) then
|
||||
-- effective limit differs from set limit, unit is degraded
|
||||
@ -183,7 +183,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
unallocated = math.max(0, unallocated - ctl.br100)
|
||||
|
||||
if last ~= ctl.br100 then u.a_commit_br100(ramp) end
|
||||
if last ~= ctl.br100 then u.auto_commit_br100(ramp) end
|
||||
end
|
||||
end
|
||||
end
|
||||
@ -320,7 +320,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.start_fail = START_STATUS.BLADE_MISMATCH
|
||||
end
|
||||
|
||||
if self.start_fail == START_STATUS.OK then u.a_engage() end
|
||||
if self.start_fail == START_STATUS.OK then u.auto_engage() end
|
||||
|
||||
self.max_burn_combined = self.max_burn_combined + (u.get_control_inf().lim_br100 / 100.0)
|
||||
end
|
||||
@ -340,7 +340,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- use manual SCRAM since inactive was requested, and automatic SCRAM trips an alarm
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
u.scram()
|
||||
u.a_disengage()
|
||||
u.auto_disengage()
|
||||
end
|
||||
end
|
||||
|
||||
@ -601,7 +601,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- SCRAM all units
|
||||
for i = 1, #self.prio_defs do
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
u.a_scram()
|
||||
u.auto_scram()
|
||||
end
|
||||
end
|
||||
|
||||
@ -653,7 +653,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- reset PLC RPS trips if we should
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
u.a_cond_rps_reset()
|
||||
u.auto_cond_rps_reset()
|
||||
end
|
||||
end
|
||||
end
|
||||
|
@ -20,7 +20,7 @@ local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v0.16.7"
|
||||
local SUPERVISOR_VERSION = "v0.16.8"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
@ -506,7 +506,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
--#region
|
||||
|
||||
-- engage automatic control
|
||||
function public.a_engage()
|
||||
function public.auto_engage()
|
||||
self.auto_engaged = true
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_lock(true)
|
||||
@ -514,7 +514,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
end
|
||||
|
||||
-- disengage automatic control
|
||||
function public.a_disengage()
|
||||
function public.auto_disengage()
|
||||
self.auto_engaged = false
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_lock(false)
|
||||
@ -526,7 +526,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
-- if it is degraded or not ready, the limit will be 0
|
||||
---@nodiscard
|
||||
---@return integer lim_br100
|
||||
function public.a_get_effective_limit()
|
||||
function public.auto_get_effective_limit()
|
||||
if (not self.db.control.ready) or self.db.control.degraded or self.plc_cache.rps_trip then
|
||||
self.db.control.br100 = 0
|
||||
return 0
|
||||
@ -537,7 +537,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
-- set the automatic burn rate based on the last set burn rate in 100ths
|
||||
---@param ramp boolean true to ramp to rate, false to set right away
|
||||
function public.a_commit_br100(ramp)
|
||||
function public.auto_commit_br100(ramp)
|
||||
if self.auto_engaged then
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_set_burn(self.db.control.br100 / 100, ramp)
|
||||
@ -550,16 +550,16 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
-- check if ramping is complete (burn rate is same as target)
|
||||
---@nodiscard
|
||||
---@return boolean complete
|
||||
function public.a_ramp_complete()
|
||||
function public.auto_ramp_complete()
|
||||
if self.plc_i ~= nil then
|
||||
return self.plc_i.is_ramp_complete() or
|
||||
(self.plc_i.get_status().act_burn_rate == 0 and self.db.control.br100 == 0) or
|
||||
public.a_get_effective_limit() == 0
|
||||
public.auto_get_effective_limit() == 0
|
||||
else return true end
|
||||
end
|
||||
|
||||
-- perform an automatic SCRAM
|
||||
function public.a_scram()
|
||||
function public.auto_scram()
|
||||
if self.plc_s ~= nil then
|
||||
self.db.control.br100 = 0
|
||||
self.plc_s.in_queue.push_command(PLC_S_CMDS.ASCRAM)
|
||||
@ -567,7 +567,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
end
|
||||
|
||||
-- queue a command to clear timeout/auto-scram if set
|
||||
function public.a_cond_rps_reset()
|
||||
function public.auto_cond_rps_reset()
|
||||
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then
|
||||
local rps = self.plc_i.get_rps()
|
||||
if rps.timeout or rps.automatic then
|
||||
|
@ -549,7 +549,7 @@ function logic.update_auto_safety(public, self)
|
||||
end
|
||||
|
||||
if alarmed and not self.plc_cache.rps_status.automatic then
|
||||
public.a_scram()
|
||||
public.auto_scram()
|
||||
end
|
||||
|
||||
self.auto_was_alarmed = alarmed
|
||||
|
Loading…
Reference in New Issue