@ -79,7 +79,7 @@ local tool_ctl = {
|
||||
sv_cool_conf = nil, ---@type table list of boiler & turbine counts
|
||||
show_sv_cfg = nil, ---@type function
|
||||
|
||||
start_fail = false,
|
||||
start_fail = 0,
|
||||
fail_message = "",
|
||||
has_config = false,
|
||||
viewing_config = false,
|
||||
@ -120,8 +120,8 @@ local tmp_cfg = {
|
||||
SpeakerVolume = 1.0,
|
||||
Time24Hour = true,
|
||||
DisableFlowView = false,
|
||||
MainDisplay = nil,
|
||||
FlowDisplay = nil,
|
||||
MainDisplay = nil, ---@type string
|
||||
FlowDisplay = nil, ---@type string
|
||||
UnitDisplays = {},
|
||||
SVR_Channel = nil, ---@type integer
|
||||
CRD_Channel = nil, ---@type integer
|
||||
@ -161,9 +161,13 @@ local fields = {
|
||||
{ "LogDebug","Log Debug Messages", false }
|
||||
}
|
||||
|
||||
-- check if a value is an integer within a range (inclusive)
|
||||
---@param x integer
|
||||
---@param min integer
|
||||
---@param max integer
|
||||
local function is_int_min_max(x, min, max) return util.is_int(x) and x >= min and x <= max end
|
||||
|
||||
-- send an management packet to the supervisor
|
||||
-- send a management packet to the supervisor
|
||||
---@param msg_type MGMT_TYPE
|
||||
---@param msg table
|
||||
local function send_sv(msg_type, msg)
|
||||
@ -490,30 +494,6 @@ local function config_view(display)
|
||||
|
||||
tool_ctl.sv_conn_button = PushButton{parent=fac_c_1,x=1,y=9,text="Connect",min_width=9,callback=function()tool_ctl.sv_connect()end,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg,dis_fg_bg=dis_fg_bg}
|
||||
|
||||
function tool_ctl.sv_connect()
|
||||
tool_ctl.sv_conn_button.disable()
|
||||
tool_ctl.sv_conn_detail.set_value("")
|
||||
|
||||
local modem = ppm.get_wireless_modem()
|
||||
if modem == nil then
|
||||
tool_ctl.sv_conn_status.set_value("Please connect an ender/wireless modem.")
|
||||
else
|
||||
tool_ctl.sv_conn_status.set_value("Modem found, connecting...")
|
||||
if tool_ctl.nic == nil then tool_ctl.nic = network.nic(modem) end
|
||||
|
||||
tool_ctl.nic.closeAll()
|
||||
tool_ctl.nic.open(tmp_cfg.CRD_Channel)
|
||||
|
||||
tool_ctl.sv_addr = comms.BROADCAST
|
||||
tool_ctl.sv_seq_num = 0
|
||||
tool_ctl.net_listen = true
|
||||
|
||||
send_sv(MGMT_TYPE.ESTABLISH, { comms.version, "0.0.0", DEVICE_TYPE.CRD })
|
||||
|
||||
tcd.dispatch_unique(8, handle_timeout)
|
||||
end
|
||||
end
|
||||
|
||||
local function sv_skip()
|
||||
tcd.abort(handle_timeout)
|
||||
tool_ctl.sv_fac_conf = nil
|
||||
@ -575,47 +555,6 @@ local function config_view(display)
|
||||
TextBox{parent=mon_c_1,x=1,y=1,height=5,text="Your configuration requires the following monitors. The main and flow monitors' heights are dependent on your unit count and cooling setup. If you manually entered the unit count, a * will be shown on potentially inaccurate calculations."}
|
||||
local mon_reqs = ListBox{parent=mon_c_1,x=1,y=7,height=6,width=51,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
function tool_ctl.update_mon_reqs()
|
||||
local plural = tmp_cfg.UnitCount > 1
|
||||
|
||||
if tool_ctl.sv_cool_conf ~= nil then
|
||||
local cnf = tool_ctl.sv_cool_conf
|
||||
|
||||
local row1_tall = cnf[1][1] > 1 or cnf[1][2] > 2 or (cnf[2] and (cnf[2][1] > 1 or cnf[2][2] > 2))
|
||||
local row1_short = (cnf[1][1] == 0 and cnf[1][2] == 1) and (cnf[2] == nil or (cnf[2][1] == 0 and cnf[2][2] == 1))
|
||||
local row2_tall = (cnf[3] and (cnf[3][1] > 1 or cnf[3][2] > 2)) or (cnf[4] and (cnf[4][1] > 1 or cnf[4][2] > 2))
|
||||
local row2_short = (cnf[3] == nil or (cnf[3][1] == 0 and cnf[3][2] == 1)) and (cnf[4] == nil or (cnf[4][1] == 0 and cnf[4][2] == 1))
|
||||
|
||||
if tmp_cfg.UnitCount <= 2 then
|
||||
tool_ctl.main_mon_h = util.trinary(row1_tall, 5, 4)
|
||||
else
|
||||
-- is only one tall and the other short, or are both tall? -> 5 or 6; are neither tall? -> 5
|
||||
if row1_tall or row2_tall then
|
||||
tool_ctl.main_mon_h = util.trinary((row1_short and row2_tall) or (row1_tall and row2_short), 5, 6)
|
||||
else tool_ctl.main_mon_h = 5 end
|
||||
end
|
||||
else
|
||||
tool_ctl.main_mon_h = util.trinary(tmp_cfg.UnitCount <= 2, 4, 5)
|
||||
end
|
||||
|
||||
tool_ctl.flow_mon_h = 2 + tmp_cfg.UnitCount
|
||||
|
||||
local asterisk = util.trinary(tool_ctl.sv_cool_conf == nil, "*", "")
|
||||
local m_at_least = util.trinary(tool_ctl.main_mon_h < 6, "at least ", "")
|
||||
local f_at_least = util.trinary(tool_ctl.flow_mon_h < 6, "at least ", "")
|
||||
|
||||
mon_reqs.remove_all()
|
||||
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a "..tmp_cfg.UnitCount.." Unit View Monitor"..util.trinary(plural,"s","")}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" "..util.trinary(plural,"each ","").."must be 4 blocks wide by 4 tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a 1 Main View Monitor"}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" must be 8 blocks wide by "..m_at_least..tool_ctl.main_mon_h..asterisk.." tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
if not tmp_cfg.DisableFlowView then
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a 1 Flow View Monitor"}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" must be 8 blocks wide by "..f_at_least..tool_ctl.flow_mon_h.." tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
end
|
||||
end
|
||||
|
||||
local function next_from_reqs()
|
||||
-- unassign unit monitors above the unit count
|
||||
for i = tmp_cfg.UnitCount + 1, 4 do tmp_cfg.UnitDisplays[i] = nil end
|
||||
@ -672,7 +611,7 @@ local function config_view(display)
|
||||
mon_warn.show()
|
||||
elseif not util.table_contains(tool_ctl.mon_expect, val) then
|
||||
tool_ctl.apply_mon.disable()
|
||||
mon_warn.set_value("That assignment doesn't match monitor dimensions. You'll need to resize the monitor for it to work.")
|
||||
mon_warn.set_value("That assignment doesn't fit monitor dimensions. You'll need to resize the monitor for it to work.")
|
||||
mon_warn.show()
|
||||
else
|
||||
tool_ctl.apply_mon.enable()
|
||||
@ -709,9 +648,7 @@ local function config_view(display)
|
||||
tmp_cfg.FlowDisplay = nil
|
||||
else
|
||||
for i = 1, tmp_cfg.UnitCount do
|
||||
if tmp_cfg.UnitDisplays[i] == iface then
|
||||
tmp_cfg.UnitDisplays[i] = nil
|
||||
end
|
||||
if tmp_cfg.UnitDisplays[i] == iface then tmp_cfg.UnitDisplays[i] = nil end
|
||||
end
|
||||
end
|
||||
end
|
||||
@ -744,7 +681,7 @@ local function config_view(display)
|
||||
tool_ctl.apply_mon = PushButton{parent=mon_c_3,x=43,y=14,min_width=7,text="Apply",callback=apply_monitor,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg,dis_fg_bg=dis_fg_bg}
|
||||
|
||||
TextBox{parent=mon_c_4,x=1,y=1,height=3,text="For legacy compatibility with facilities built without space for a flow monitor, you can disable the flow monitor requirement here."}
|
||||
TextBox{parent=mon_c_4,x=1,y=5,height=3,text="Please be aware that THIS WILL BE REMOVED ON RELEASE. It will only be available for the remainder of the beta."}
|
||||
TextBox{parent=mon_c_4,x=1,y=5,height=3,text="Please be aware that THIS OPTION WILL BE REMOVED ON RELEASE. Disabling it will only be available for the remainder of the beta."}
|
||||
|
||||
local dis_flow_view = CheckBox{parent=mon_c_4,x=1,y=9,default=ini_cfg.DisableFlowView,label="Disable Flow View Monitor",box_fg_bg=cpair(colors.blue,colors.black)}
|
||||
|
||||
@ -1023,22 +960,85 @@ local function config_view(display)
|
||||
tool_ctl.importing_legacy = true
|
||||
end
|
||||
|
||||
-- attempt a connection to the supervisor to get cooling info
|
||||
function tool_ctl.sv_connect()
|
||||
tool_ctl.sv_conn_button.disable()
|
||||
tool_ctl.sv_conn_detail.set_value("")
|
||||
|
||||
local modem = ppm.get_wireless_modem()
|
||||
if modem == nil then
|
||||
tool_ctl.sv_conn_status.set_value("Please connect an ender/wireless modem.")
|
||||
else
|
||||
tool_ctl.sv_conn_status.set_value("Modem found, connecting...")
|
||||
if tool_ctl.nic == nil then tool_ctl.nic = network.nic(modem) end
|
||||
|
||||
tool_ctl.nic.closeAll()
|
||||
tool_ctl.nic.open(tmp_cfg.CRD_Channel)
|
||||
|
||||
tool_ctl.sv_addr = comms.BROADCAST
|
||||
tool_ctl.sv_seq_num = 0
|
||||
tool_ctl.net_listen = true
|
||||
|
||||
send_sv(MGMT_TYPE.ESTABLISH, { comms.version, "0.0.0", DEVICE_TYPE.CRD })
|
||||
|
||||
tcd.dispatch_unique(8, handle_timeout)
|
||||
end
|
||||
end
|
||||
|
||||
-- show the facility's unit count and cooling configuration data
|
||||
function tool_ctl.show_sv_cfg()
|
||||
local conf = tool_ctl.sv_cool_conf
|
||||
fac_config_list.remove_all()
|
||||
|
||||
local str = util.sprintf("Facility has %d reactor units:", #conf)
|
||||
|
||||
local line = Div{parent=fac_config_list,height=1,fg_bg=cpair(colors.gray,colors.white)}
|
||||
TextBox{parent=line,text=str,fg_bg=cpair(colors.black,line.get_fg_bg().bkg)}
|
||||
TextBox{parent=fac_config_list,height=1,text=str,fg_bg=cpair(colors.gray,colors.white)}
|
||||
|
||||
for i = 1, #conf do
|
||||
local num_b, num_t = conf[i][1], conf[i][2]
|
||||
str = util.sprintf("\x07 Unit %d has %d boiler%s and %d turbine%s", i, num_b, util.trinary(num_b == 1, "", "s"), num_t, util.trinary(num_t == 1, "", "s"))
|
||||
TextBox{parent=fac_config_list,height=1,text=str,fg_bg=cpair(colors.gray,colors.white)}
|
||||
end
|
||||
end
|
||||
|
||||
local c_line = Div{parent=fac_config_list,height=1,fg_bg=cpair(colors.gray,colors.white)}
|
||||
TextBox{parent=c_line,text=str,fg_bg=cpair(colors.black,line.get_fg_bg().bkg)}
|
||||
-- update list of monitor requirements
|
||||
function tool_ctl.update_mon_reqs()
|
||||
local plural = tmp_cfg.UnitCount > 1
|
||||
|
||||
if tool_ctl.sv_cool_conf ~= nil then
|
||||
local cnf = tool_ctl.sv_cool_conf
|
||||
|
||||
local row1_tall = cnf[1][1] > 1 or cnf[1][2] > 2 or (cnf[2] and (cnf[2][1] > 1 or cnf[2][2] > 2))
|
||||
local row1_short = (cnf[1][1] == 0 and cnf[1][2] == 1) and (cnf[2] == nil or (cnf[2][1] == 0 and cnf[2][2] == 1))
|
||||
local row2_tall = (cnf[3] and (cnf[3][1] > 1 or cnf[3][2] > 2)) or (cnf[4] and (cnf[4][1] > 1 or cnf[4][2] > 2))
|
||||
local row2_short = (cnf[3] == nil or (cnf[3][1] == 0 and cnf[3][2] == 1)) and (cnf[4] == nil or (cnf[4][1] == 0 and cnf[4][2] == 1))
|
||||
|
||||
if tmp_cfg.UnitCount <= 2 then
|
||||
tool_ctl.main_mon_h = util.trinary(row1_tall, 5, 4)
|
||||
else
|
||||
-- is only one tall and the other short, or are both tall? -> 5 or 6; are neither tall? -> 5
|
||||
if row1_tall or row2_tall then
|
||||
tool_ctl.main_mon_h = util.trinary((row1_short and row2_tall) or (row1_tall and row2_short), 5, 6)
|
||||
else tool_ctl.main_mon_h = 5 end
|
||||
end
|
||||
else
|
||||
tool_ctl.main_mon_h = util.trinary(tmp_cfg.UnitCount <= 2, 4, 5)
|
||||
end
|
||||
|
||||
tool_ctl.flow_mon_h = 2 + tmp_cfg.UnitCount
|
||||
|
||||
local asterisk = util.trinary(tool_ctl.sv_cool_conf == nil, "*", "")
|
||||
local m_at_least = util.trinary(tool_ctl.main_mon_h < 6, "at least ", "")
|
||||
local f_at_least = util.trinary(tool_ctl.flow_mon_h < 6, "at least ", "")
|
||||
|
||||
mon_reqs.remove_all()
|
||||
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a "..tmp_cfg.UnitCount.." Unit View Monitor"..util.trinary(plural,"s","")}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" "..util.trinary(plural,"each ","").."must be 4 blocks wide by 4 tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a 1 Main View Monitor"}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" must be 8 blocks wide by "..m_at_least..tool_ctl.main_mon_h..asterisk.." tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
if not tmp_cfg.DisableFlowView then
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text="\x1a 1 Flow View Monitor"}
|
||||
TextBox{parent=mon_reqs,x=1,y=1,height=1,text=" must be 8 blocks wide by "..f_at_least..tool_ctl.flow_mon_h.." tall",fg_bg=cpair(colors.gray,colors.white)}
|
||||
end
|
||||
end
|
||||
|
||||
@ -1178,7 +1178,7 @@ local function config_view(display)
|
||||
|
||||
if f[1] == "AuthKey" then val = string.rep("*", string.len(val))
|
||||
elseif f[1] == "LogMode" then val = util.trinary(raw == log.MODE.APPEND, "append", "replace")
|
||||
elseif f[1] == "UnitDisplays" then
|
||||
elseif f[1] == "UnitDisplays" and type(cfg.UnitDisplays) == "table" then
|
||||
val = ""
|
||||
for idx = 1, #cfg.UnitDisplays do
|
||||
val = val .. util.trinary(idx == 1, "", "\n") .. util.sprintf(" \x07 Unit %d - %s", idx, cfg.UnitDisplays[idx])
|
||||
@ -1195,7 +1195,7 @@ local function config_view(display)
|
||||
height = #lines + 1
|
||||
end
|
||||
|
||||
if f[1] == "UnitDisplays" and height == 1 then height = 2 end
|
||||
if (f[1] == "UnitDisplays") and (height == 1) and (val ~= "<not set>") then height = 2 end
|
||||
|
||||
local line = Div{parent=setting_list,height=height,fg_bg=c}
|
||||
TextBox{parent=line,text=f[2],width=string.len(f[2]),fg_bg=cpair(colors.black,line.get_fg_bg().bkg)}
|
||||
@ -1221,11 +1221,11 @@ local function reset_term()
|
||||
end
|
||||
|
||||
-- run the coordinator configurator<br>
|
||||
-- start_fail of 0 is OK (not expected, default if not provided), 1 is bad config, 2 is bad monitor config
|
||||
---@param start_fail? 0|1|2 indicate if this is being called by the startup app due to an invalid configuration
|
||||
-- start_fail of 0 is OK (default if not provided), 1 is bad config, 2 is bad monitor config
|
||||
---@param start_code? 0|1|2 indicate error state when called from the startup app
|
||||
---@param message? any string message to display on a start_fail of 2
|
||||
function configurator.configure(start_fail, message)
|
||||
tool_ctl.start_fail = start_fail or 0
|
||||
function configurator.configure(start_code, message)
|
||||
tool_ctl.start_fail = start_code or 0
|
||||
tool_ctl.fail_message = util.trinary(type(message) == "string", message, "")
|
||||
|
||||
load_settings(settings_cfg, true)
|
||||
|
@ -31,7 +31,7 @@ if not plc.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(plc.load_config(), "failed to load valid reactor PLC configuration")
|
||||
assert(plc.load_config(), "failed to load valid configuration")
|
||||
else
|
||||
assert(success, "reactor PLC configuration error: " .. error)
|
||||
end
|
||||
|
@ -47,7 +47,7 @@ if not rtu.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(rtu.load_config(), "failed to load valid RTU configuration")
|
||||
assert(rtu.load_config(), "failed to load valid configuration")
|
||||
else
|
||||
assert(success, "RTU configuration error: " .. error)
|
||||
end
|
||||
|
@ -425,13 +425,11 @@ end
|
||||
|
||||
-- get the block size of a monitor given its width and height <b>at a text scale of 0.5</b>
|
||||
---@nodiscard
|
||||
---@param w integer character width
|
||||
---@param h integer character height
|
||||
---@param width integer character width
|
||||
---@param height integer character height
|
||||
---@return integer block_width, integer block_height
|
||||
function ppm.monitor_block_size(w, h)
|
||||
local width = math.floor((w - 15) / 21) + 1
|
||||
local height = math.floor((h - 10) / 14) + 1
|
||||
return width, height
|
||||
function ppm.monitor_block_size(width, height)
|
||||
return math.floor((width - 15) / 21) + 1, math.floor((height - 10) / 14) + 1
|
||||
end
|
||||
|
||||
return ppm
|
||||
|
@ -968,7 +968,7 @@ local function config_view(display)
|
||||
|
||||
if f[1] == "AuthKey" then val = string.rep("*", string.len(val))
|
||||
elseif f[1] == "LogMode" then val = util.trinary(raw == log.MODE.APPEND, "append", "replace")
|
||||
elseif f[1] == "CoolingConfig" and cfg.CoolingConfig then
|
||||
elseif f[1] == "CoolingConfig" and type(cfg.CoolingConfig) == "table" then
|
||||
val = ""
|
||||
|
||||
for idx = 1, #cfg.CoolingConfig do
|
||||
@ -982,7 +982,7 @@ local function config_view(display)
|
||||
|
||||
if val == "" then val = "no facility tanks" end
|
||||
elseif f[1] == "FacilityTankMode" and raw == 0 then val = "0 (n/a, unit mode)"
|
||||
elseif f[1] == "FacilityTankDefs" and cfg.FacilityTankDefs then
|
||||
elseif f[1] == "FacilityTankDefs" and type(cfg.FacilityTankDefs) == "table" then
|
||||
val = ""
|
||||
|
||||
for idx = 1, #cfg.FacilityTankDefs do
|
||||
|
@ -34,7 +34,7 @@ if not supervisor.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(supervisor.load_config(), "failed to load valid supervisor configuration")
|
||||
assert(supervisor.load_config(), "failed to load valid configuration")
|
||||
else
|
||||
assert(success, "supervisor configuration error: " .. error)
|
||||
end
|
||||
|