mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
fixed recording bad stats on induction matrix faults
This commit is contained in:
parent
f958b0e3b7
commit
25dc47d520
@ -137,7 +137,9 @@ function facility.new(config, cooling_conf)
|
||||
avg_net = util.mov_avg(60), -- 60 seconds
|
||||
imtx_last_capacity = 0,
|
||||
imtx_last_charge = 0,
|
||||
imtx_last_charge_t = 0
|
||||
imtx_last_charge_t = 0,
|
||||
-- track faulted induction matrix update times to reject
|
||||
imtx_faulted_times = { 0, 0, 0 }
|
||||
}
|
||||
|
||||
-- create units
|
||||
@ -310,10 +312,26 @@ function facility.new(config, cooling_conf)
|
||||
local matrix = self.induction[1] ---@type unit_session
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
|
||||
charge_update = db.tanks.last_update
|
||||
local build_update = db.build.last_update
|
||||
rate_update = db.state.last_update
|
||||
charge_update = db.tanks.last_update
|
||||
|
||||
if (charge_update > 0) and (rate_update > 0) then
|
||||
local has_data = build_update > 0 and rate_update > 0 and charge_update > 0
|
||||
|
||||
if matrix.is_faulted() then
|
||||
-- a fault occured, cannot reliably update stats
|
||||
has_data = false
|
||||
self.im_stat_init = false
|
||||
self.imtx_faulted_times = { build_update, rate_update, charge_update }
|
||||
elseif not self.im_stat_init then
|
||||
-- prevent operation with partially invalid data
|
||||
-- all fields must have updated since the last fault
|
||||
has_data = self.imtx_faulted_times[1] < build_update and
|
||||
self.imtx_faulted_times[2] < rate_update and
|
||||
self.imtx_faulted_times[3] < charge_update
|
||||
end
|
||||
|
||||
if has_data then
|
||||
local energy = util.joules_to_fe(db.tanks.energy)
|
||||
local input = util.joules_to_fe(db.state.last_input)
|
||||
local output = util.joules_to_fe(db.state.last_output)
|
||||
@ -349,6 +367,10 @@ function facility.new(config, cooling_conf)
|
||||
self.imtx_last_charge = energy
|
||||
self.imtx_last_charge_t = charge_update
|
||||
end
|
||||
else
|
||||
-- prevent use by control systems
|
||||
rate_update = 0
|
||||
charge_update = 0
|
||||
end
|
||||
else
|
||||
self.im_stat_init = false
|
||||
@ -507,7 +529,7 @@ function facility.new(config, cooling_conf)
|
||||
|
||||
self.status_text = { "CHARGE MODE", "running control loop" }
|
||||
log.info("FAC: CHARGE mode starting PID control")
|
||||
elseif self.last_update ~= charge_update then
|
||||
elseif self.last_update < charge_update then
|
||||
-- convert to kFE to make constants not microscopic
|
||||
local error = util.round((self.charge_setpoint - avg_charge) / 1000) / 1000
|
||||
|
||||
@ -581,7 +603,7 @@ function facility.new(config, cooling_conf)
|
||||
self.status_text = { "GENERATION MODE", "running control loop" }
|
||||
log.info("FAC: GEN_RATE process mode initial hold completed, starting PID control")
|
||||
end
|
||||
elseif self.last_update ~= rate_update then
|
||||
elseif self.last_update < rate_update then
|
||||
-- convert to MFE (in rounded kFE) to make constants not microscopic
|
||||
local error = util.round((self.gen_rate_setpoint - avg_inflow) / 1000) / 1000
|
||||
|
||||
|
@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v1.3.9"
|
||||
local SUPERVISOR_VERSION = "v1.3.10"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
Loading…