#139 emergency coolant enabled on RPS low coolant

This commit is contained in:
Mikayla Fischler
2023-02-13 18:20:48 -05:00
parent ccd9f4b6cc
commit 2affe1b31c
3 changed files with 30 additions and 12 deletions

View File

@ -108,6 +108,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
plc_cache = {
active = false,
ok = false,
rps_trip = false,
---@type rps_status
rps_status = {
dmg_crit = false,
@ -315,11 +316,12 @@ function unit.new(for_reactor, num_boilers, num_turbines)
local __rs_w = rs_rtu_io_ctl.digital_write
local __rs_r = rs_rtu_io_ctl.digital_read
-- waste valves
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
-- valves
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
local emer_cool = { open = function () __rs_w(IO.U_EMER_COOL, true) end, close = function () __rs_w(IO.U_EMER_COOL, false) end }
--#endregion
@ -462,6 +464,15 @@ function unit.new(for_reactor, num_boilers, num_turbines)
-- update status text
logic.update_status_text(self)
-- check if emergency coolant is needed
if self.plc_cache.rps_status.no_cool then
emer_cool.open()
elseif not self.plc_cache.rps_trip then
-- can't turn off on sufficient coolant level since it might drop again
-- turn off once system is OK again
emer_cool.close()
end
end