mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#139 emergency coolant enabled on RPS low coolant
This commit is contained in:
@ -108,6 +108,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
plc_cache = {
|
||||
active = false,
|
||||
ok = false,
|
||||
rps_trip = false,
|
||||
---@type rps_status
|
||||
rps_status = {
|
||||
dmg_crit = false,
|
||||
@ -315,11 +316,12 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
local __rs_w = rs_rtu_io_ctl.digital_write
|
||||
local __rs_r = rs_rtu_io_ctl.digital_read
|
||||
|
||||
-- waste valves
|
||||
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
|
||||
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
|
||||
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
|
||||
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
|
||||
-- valves
|
||||
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
|
||||
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
|
||||
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
|
||||
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
|
||||
local emer_cool = { open = function () __rs_w(IO.U_EMER_COOL, true) end, close = function () __rs_w(IO.U_EMER_COOL, false) end }
|
||||
|
||||
--#endregion
|
||||
|
||||
@ -462,6 +464,15 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- update status text
|
||||
logic.update_status_text(self)
|
||||
|
||||
-- check if emergency coolant is needed
|
||||
if self.plc_cache.rps_status.no_cool then
|
||||
emer_cool.open()
|
||||
elseif not self.plc_cache.rps_trip then
|
||||
-- can't turn off on sufficient coolant level since it might drop again
|
||||
-- turn off once system is OK again
|
||||
emer_cool.close()
|
||||
end
|
||||
end
|
||||
|
||||
-- AUTO CONTROL OPERATIONS --
|
||||
|
Reference in New Issue