mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#201 supervisor pocket diagnostics session
This commit is contained in:
parent
d295c2b3c3
commit
449e393b73
@ -10,6 +10,7 @@ config.TRUSTED_RANGE = 0
|
||||
config.PLC_TIMEOUT = 5
|
||||
config.RTU_TIMEOUT = 5
|
||||
config.CRD_TIMEOUT = 5
|
||||
config.PKT_TIMEOUT = 5
|
||||
|
||||
-- expected number of reactors
|
||||
config.NUM_REACTORS = 4
|
||||
|
@ -64,7 +64,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
|
||||
connected = true,
|
||||
received_struct = false,
|
||||
received_status_cache = false,
|
||||
plc_conn_watchdog = util.new_watchdog(timeout),
|
||||
conn_watchdog = util.new_watchdog(timeout),
|
||||
last_rtt = 0,
|
||||
-- periodic messages
|
||||
periodics = {
|
||||
@ -233,7 +233,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
|
||||
|
||||
-- mark this PLC session as closed, stop watchdog
|
||||
local function _close()
|
||||
self.plc_conn_watchdog.cancel()
|
||||
self.conn_watchdog.cancel()
|
||||
self.connected = false
|
||||
end
|
||||
|
||||
@ -301,7 +301,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
|
||||
end
|
||||
|
||||
-- feed watchdog
|
||||
self.plc_conn_watchdog.feed()
|
||||
self.conn_watchdog.feed()
|
||||
|
||||
-- handle packet by type
|
||||
if pkt.type == RPLC_TYPE.STATUS then
|
||||
@ -576,7 +576,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
|
||||
-- check if a timer matches this session's watchdog
|
||||
---@nodiscard
|
||||
function public.check_wd(timer)
|
||||
return self.plc_conn_watchdog.is_timer(timer) and self.connected
|
||||
return self.conn_watchdog.is_timer(timer) and self.connected
|
||||
end
|
||||
|
||||
-- close the connection
|
||||
|
222
supervisor/session/pocket.lua
Normal file
222
supervisor/session/pocket.lua
Normal file
@ -0,0 +1,222 @@
|
||||
local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local pocket = {}
|
||||
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
||||
|
||||
local println = util.println
|
||||
|
||||
-- retry time constants in ms
|
||||
-- local INITIAL_WAIT = 1500
|
||||
-- local RETRY_PERIOD = 1000
|
||||
|
||||
local POCKET_S_CMDS = {
|
||||
}
|
||||
|
||||
local POCKET_S_DATA = {
|
||||
}
|
||||
|
||||
pocket.POCKET_S_CMDS = POCKET_S_CMDS
|
||||
pocket.POCKET_S_DATA = POCKET_S_DATA
|
||||
|
||||
local PERIODICS = {
|
||||
KEEP_ALIVE = 2000
|
||||
}
|
||||
|
||||
-- pocket diagnostics session
|
||||
---@nodiscard
|
||||
---@param id integer session ID
|
||||
---@param in_queue mqueue in message queue
|
||||
---@param out_queue mqueue out message queue
|
||||
---@param timeout number communications timeout
|
||||
function pocket.new_session(id, in_queue, out_queue, timeout)
|
||||
local log_header = "diag_session(" .. id .. "): "
|
||||
|
||||
local self = {
|
||||
-- connection properties
|
||||
seq_num = 0,
|
||||
r_seq_num = nil,
|
||||
connected = true,
|
||||
conn_watchdog = util.new_watchdog(timeout),
|
||||
last_rtt = 0,
|
||||
-- periodic messages
|
||||
periodics = {
|
||||
keep_alive = 0
|
||||
},
|
||||
-- when to next retry one of these requests
|
||||
retry_times = {
|
||||
},
|
||||
-- command acknowledgements
|
||||
acks = {
|
||||
},
|
||||
-- session database
|
||||
---@class diag_db
|
||||
sDB = {
|
||||
}
|
||||
}
|
||||
|
||||
---@class diag_session
|
||||
local public = {}
|
||||
|
||||
-- mark this diagnostics session as closed, stop watchdog
|
||||
local function _close()
|
||||
self.conn_watchdog.cancel()
|
||||
self.connected = false
|
||||
end
|
||||
|
||||
-- send a SCADA management packet
|
||||
---@param msg_type SCADA_MGMT_TYPE
|
||||
---@param msg table
|
||||
local function _send_mgmt(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
out_queue.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- handle a packet
|
||||
---@param pkt mgmt_frame
|
||||
local function _handle_packet(pkt)
|
||||
-- check sequence number
|
||||
if self.r_seq_num == nil then
|
||||
self.r_seq_num = pkt.scada_frame.seq_num()
|
||||
elseif self.r_seq_num >= pkt.scada_frame.seq_num() then
|
||||
log.warning(log_header .. "sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. pkt.scada_frame.seq_num())
|
||||
return
|
||||
else
|
||||
self.r_seq_num = pkt.scada_frame.seq_num()
|
||||
end
|
||||
|
||||
-- process packet
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
---@cast pkt mgmt_frame
|
||||
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive reply
|
||||
if pkt.length == 2 then
|
||||
local srv_start = pkt.data[1]
|
||||
-- local diag_send = pkt.data[2]
|
||||
local srv_now = util.time()
|
||||
self.last_rtt = srv_now - srv_start
|
||||
|
||||
if self.last_rtt > 750 then
|
||||
log.warning(log_header .. "DIAG KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
|
||||
end
|
||||
|
||||
-- log.debug(log_header .. "DIAG RTT = " .. self.last_rtt .. "ms")
|
||||
-- log.debug(log_header .. "DIAG TT = " .. (srv_now - diag_send) .. "ms")
|
||||
else
|
||||
log.debug(log_header .. "SCADA keep alive packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
|
||||
-- close the session
|
||||
_close()
|
||||
else
|
||||
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- get the session ID
|
||||
---@nodiscard
|
||||
function public.get_id() return id end
|
||||
|
||||
-- get the session database
|
||||
---@nodiscard
|
||||
function public.get_db() return self.sDB end
|
||||
|
||||
-- check if a timer matches this session's watchdog
|
||||
---@nodiscard
|
||||
function public.check_wd(timer)
|
||||
return self.conn_watchdog.is_timer(timer) and self.connected
|
||||
end
|
||||
|
||||
-- close the connection
|
||||
function public.close()
|
||||
_close()
|
||||
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
|
||||
println("connection to pocket diag session " .. id .. " closed by server")
|
||||
log.info(log_header .. "session closed by server")
|
||||
end
|
||||
|
||||
-- iterate the session
|
||||
---@nodiscard
|
||||
---@return boolean connected
|
||||
function public.iterate()
|
||||
if self.connected then
|
||||
------------------
|
||||
-- handle queue --
|
||||
------------------
|
||||
|
||||
local handle_start = util.time()
|
||||
|
||||
while in_queue.ready() and self.connected do
|
||||
-- get a new message to process
|
||||
local message = in_queue.pop()
|
||||
|
||||
if message ~= nil then
|
||||
if message.qtype == mqueue.TYPE.PACKET then
|
||||
-- handle a packet
|
||||
_handle_packet(message.message)
|
||||
elseif message.qtype == mqueue.TYPE.COMMAND then
|
||||
-- handle instruction
|
||||
elseif message.qtype == mqueue.TYPE.DATA then
|
||||
-- instruction with body
|
||||
end
|
||||
end
|
||||
|
||||
-- max 100ms spent processing queue
|
||||
if util.time() - handle_start > 100 then
|
||||
log.warning(log_header .. "exceeded 100ms queue process limit")
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
-- exit if connection was closed
|
||||
if not self.connected then
|
||||
println("connection to pocket diag session " .. id .. " closed by remote host")
|
||||
log.info(log_header .. "session closed by remote host")
|
||||
return self.connected
|
||||
end
|
||||
|
||||
----------------------
|
||||
-- update periodics --
|
||||
----------------------
|
||||
|
||||
local elapsed = util.time() - self.periodics.last_update
|
||||
|
||||
local periodics = self.periodics
|
||||
|
||||
-- keep alive
|
||||
|
||||
periodics.keep_alive = periodics.keep_alive + elapsed
|
||||
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
|
||||
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
|
||||
periodics.keep_alive = 0
|
||||
end
|
||||
|
||||
self.periodics.last_update = util.time()
|
||||
|
||||
---------------------
|
||||
-- attempt retries --
|
||||
---------------------
|
||||
|
||||
-- local rtimes = self.retry_times
|
||||
end
|
||||
|
||||
return self.connected
|
||||
end
|
||||
|
||||
return public
|
||||
end
|
||||
|
||||
return pocket
|
@ -47,7 +47,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
seq_num = 0,
|
||||
r_seq_num = nil,
|
||||
connected = true,
|
||||
rtu_conn_watchdog = util.new_watchdog(timeout),
|
||||
conn_watchdog = util.new_watchdog(timeout),
|
||||
last_rtt = 0,
|
||||
-- periodic messages
|
||||
periodics = {
|
||||
@ -174,7 +174,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
|
||||
-- mark this RTU session as closed, stop watchdog
|
||||
local function _close()
|
||||
self.rtu_conn_watchdog.cancel()
|
||||
self.conn_watchdog.cancel()
|
||||
self.connected = false
|
||||
|
||||
-- mark all RTU unit sessions as closed so the reactor unit knows
|
||||
@ -222,7 +222,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
end
|
||||
|
||||
-- feed watchdog
|
||||
self.rtu_conn_watchdog.feed()
|
||||
self.conn_watchdog.feed()
|
||||
|
||||
-- process packet
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
|
||||
@ -286,7 +286,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
---@nodiscard
|
||||
---@param timer number
|
||||
function public.check_wd(timer)
|
||||
return self.rtu_conn_watchdog.is_timer(timer) and self.connected
|
||||
return self.conn_watchdog.is_timer(timer) and self.connected
|
||||
end
|
||||
|
||||
-- close the connection
|
||||
|
@ -121,6 +121,7 @@ function redstone.new(session_id, unit_id, advert, out_queue)
|
||||
---@nodiscard
|
||||
read = function () return rsio.digital_is_active(port, self.phy_io.digital_in[port].phy) end,
|
||||
---@param active boolean
|
||||
---@diagnostic disable-next-line: unused-local
|
||||
write = function (active) end
|
||||
}
|
||||
|
||||
@ -155,6 +156,7 @@ function redstone.new(session_id, unit_id, advert, out_queue)
|
||||
---@return integer
|
||||
read = function () return self.phy_io.analog_in[port].phy end,
|
||||
---@param value integer
|
||||
---@diagnostic disable-next-line: unused-local
|
||||
write = function (value) end
|
||||
}
|
||||
|
||||
|
@ -9,6 +9,7 @@ local svqtypes = require("supervisor.session.svqtypes")
|
||||
|
||||
local coordinator = require("supervisor.session.coordinator")
|
||||
local plc = require("supervisor.session.plc")
|
||||
local pocket = require("supervisor.session.pocket")
|
||||
local rtu = require("supervisor.session.rtu")
|
||||
|
||||
-- Supervisor Sessions Handler
|
||||
@ -22,29 +23,28 @@ local CRD_S_DATA = coordinator.CRD_S_DATA
|
||||
local svsessions = {}
|
||||
|
||||
local SESSION_TYPE = {
|
||||
RTU_SESSION = 0,
|
||||
PLC_SESSION = 1,
|
||||
COORD_SESSION = 2
|
||||
RTU_SESSION = 0, -- RTU gateway
|
||||
PLC_SESSION = 1, -- reactor PLC
|
||||
COORD_SESSION = 2, -- coordinator
|
||||
DIAG_SESSION = 3 -- pocket diagnostics
|
||||
}
|
||||
|
||||
svsessions.SESSION_TYPE = SESSION_TYPE
|
||||
|
||||
local self = {
|
||||
modem = nil,
|
||||
modem = nil, ---@type table|nil
|
||||
num_reactors = 0,
|
||||
facility = nil, ---@type facility
|
||||
rtu_sessions = {},
|
||||
plc_sessions = {},
|
||||
coord_sessions = {},
|
||||
next_rtu_id = 0,
|
||||
next_plc_id = 0,
|
||||
next_coord_id = 0
|
||||
facility = nil, ---@type facility|nil
|
||||
sessions = { rtu = {}, plc = {}, coord = {}, diag = {} },
|
||||
next_ids = { rtu = 0, plc = 0, coord = 0, diag = 0 }
|
||||
}
|
||||
|
||||
---@alias sv_session_structs plc_session_struct|rtu_session_struct|coord_session_struct|diag_session_struct
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- handle a session output queue
|
||||
---@param session plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
---@param session sv_session_structs
|
||||
local function _sv_handle_outq(session)
|
||||
-- record handler start time
|
||||
local handle_start = util.time()
|
||||
@ -112,7 +112,7 @@ end
|
||||
---@param sessions table
|
||||
local function _iterate(sessions)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
|
||||
if session.open and session.instance.iterate() then
|
||||
_sv_handle_outq(session)
|
||||
@ -123,7 +123,7 @@ local function _iterate(sessions)
|
||||
end
|
||||
|
||||
-- cleanly close a session
|
||||
---@param session plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
---@param session sv_session_structs
|
||||
local function _shutdown(session)
|
||||
session.open = false
|
||||
session.instance.close()
|
||||
@ -143,7 +143,7 @@ end
|
||||
---@param sessions table
|
||||
local function _close(sessions)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
if session.open then _shutdown(session) end
|
||||
end
|
||||
end
|
||||
@ -153,7 +153,7 @@ end
|
||||
---@param timer_event number
|
||||
local function _check_watchdogs(sessions, timer_event)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
if session.open then
|
||||
local triggered = session.instance.check_wd(timer_event)
|
||||
if triggered then
|
||||
@ -170,7 +170,7 @@ end
|
||||
local function _free_closed(sessions)
|
||||
local f = function (session) return session.open end
|
||||
|
||||
---@param session plc_session_struct|rtu_session_struct|coord_session_struct
|
||||
---@param session sv_session_structs
|
||||
local on_delete = function (session)
|
||||
log.debug(util.c("free'ing closed ", session.s_type, " session ", session.instance.get_id(),
|
||||
" on remote port ", session.r_port))
|
||||
@ -183,7 +183,7 @@ end
|
||||
---@nodiscard
|
||||
---@param list table
|
||||
---@param port integer
|
||||
---@return plc_session_struct|rtu_session_struct|coord_session_struct|nil
|
||||
---@return sv_session_structs|nil
|
||||
local function _find_session(list, port)
|
||||
for i = 1, #list do
|
||||
if list[i].r_port == port then return list[i] end
|
||||
@ -215,7 +215,7 @@ end
|
||||
---@return rtu_session_struct|nil
|
||||
function svsessions.find_rtu_session(remote_port)
|
||||
-- check RTU sessions
|
||||
local session = _find_session(self.rtu_sessions, remote_port)
|
||||
local session = _find_session(self.sessions.rtu, remote_port)
|
||||
---@cast session rtu_session_struct
|
||||
return session
|
||||
end
|
||||
@ -226,7 +226,7 @@ end
|
||||
---@return plc_session_struct|nil
|
||||
function svsessions.find_plc_session(remote_port)
|
||||
-- check PLC sessions
|
||||
local session = _find_session(self.plc_sessions, remote_port)
|
||||
local session = _find_session(self.sessions.plc, remote_port)
|
||||
---@cast session plc_session_struct
|
||||
return session
|
||||
end
|
||||
@ -237,10 +237,10 @@ end
|
||||
---@return plc_session_struct|rtu_session_struct|nil
|
||||
function svsessions.find_device_session(remote_port)
|
||||
-- check RTU sessions
|
||||
local session = _find_session(self.rtu_sessions, remote_port)
|
||||
local session = _find_session(self.sessions.rtu, remote_port)
|
||||
|
||||
-- check PLC sessions
|
||||
if session == nil then session = _find_session(self.plc_sessions, remote_port) end
|
||||
if session == nil then session = _find_session(self.sessions.plc, remote_port) end
|
||||
---@cast session plc_session_struct|rtu_session_struct|nil
|
||||
|
||||
return session
|
||||
@ -253,7 +253,7 @@ end
|
||||
---@return coord_session_struct|nil
|
||||
function svsessions.find_coord_session(remote_port)
|
||||
-- check coordinator sessions
|
||||
local session = _find_session(self.coord_sessions, remote_port)
|
||||
local session = _find_session(self.sessions.coord, remote_port)
|
||||
---@cast session coord_session_struct
|
||||
return session
|
||||
end
|
||||
@ -262,7 +262,7 @@ end
|
||||
---@nodiscard
|
||||
---@return coord_session_struct|nil
|
||||
function svsessions.get_coord_session()
|
||||
return self.coord_sessions[1]
|
||||
return self.sessions.coord[1]
|
||||
end
|
||||
|
||||
-- get a session by reactor ID
|
||||
@ -272,9 +272,9 @@ end
|
||||
function svsessions.get_reactor_session(reactor)
|
||||
local session = nil
|
||||
|
||||
for i = 1, #self.plc_sessions do
|
||||
if self.plc_sessions[i].reactor == reactor then
|
||||
session = self.plc_sessions[i]
|
||||
for i = 1, #self.sessions.plc do
|
||||
if self.sessions.plc[i].reactor == reactor then
|
||||
session = self.sessions.plc[i]
|
||||
end
|
||||
end
|
||||
|
||||
@ -303,15 +303,15 @@ function svsessions.establish_plc_session(local_port, remote_port, for_reactor,
|
||||
instance = nil ---@type plc_session
|
||||
}
|
||||
|
||||
plc_s.instance = plc.new_session(self.next_plc_id, for_reactor, plc_s.in_queue, plc_s.out_queue, config.PLC_TIMEOUT)
|
||||
table.insert(self.plc_sessions, plc_s)
|
||||
plc_s.instance = plc.new_session(self.next_ids.plc, for_reactor, plc_s.in_queue, plc_s.out_queue, config.PLC_TIMEOUT)
|
||||
table.insert(self.sessions.plc, plc_s)
|
||||
|
||||
local units = self.facility.get_units()
|
||||
units[for_reactor].link_plc_session(plc_s)
|
||||
|
||||
log.debug(util.c("established new PLC session to ", remote_port, " with ID ", self.next_plc_id, " for reactor ", for_reactor))
|
||||
log.debug(util.c("established new PLC session to ", remote_port, " with ID ", self.next_ids.plc, " for reactor ", for_reactor))
|
||||
|
||||
self.next_plc_id = self.next_plc_id + 1
|
||||
self.next_ids.plc = self.next_ids.plc + 1
|
||||
|
||||
-- success
|
||||
return plc_s.instance.get_id()
|
||||
@ -341,12 +341,12 @@ function svsessions.establish_rtu_session(local_port, remote_port, advertisement
|
||||
instance = nil ---@type rtu_session
|
||||
}
|
||||
|
||||
rtu_s.instance = rtu.new_session(self.next_rtu_id, rtu_s.in_queue, rtu_s.out_queue, config.RTU_TIMEOUT, advertisement, self.facility)
|
||||
table.insert(self.rtu_sessions, rtu_s)
|
||||
rtu_s.instance = rtu.new_session(self.next_ids.rtu, rtu_s.in_queue, rtu_s.out_queue, config.RTU_TIMEOUT, advertisement, self.facility)
|
||||
table.insert(self.sessions.rtu, rtu_s)
|
||||
|
||||
log.debug("established new RTU session to " .. remote_port .. " with ID " .. self.next_rtu_id)
|
||||
log.debug("established new RTU session to " .. remote_port .. " with ID " .. self.next_ids.rtu)
|
||||
|
||||
self.next_rtu_id = self.next_rtu_id + 1
|
||||
self.next_ids.rtu = self.next_ids.rtu + 1
|
||||
|
||||
-- success
|
||||
return rtu_s.instance.get_id()
|
||||
@ -372,12 +372,12 @@ function svsessions.establish_coord_session(local_port, remote_port, version)
|
||||
instance = nil ---@type coord_session
|
||||
}
|
||||
|
||||
coord_s.instance = coordinator.new_session(self.next_coord_id, coord_s.in_queue, coord_s.out_queue, config.CRD_TIMEOUT, self.facility)
|
||||
table.insert(self.coord_sessions, coord_s)
|
||||
coord_s.instance = coordinator.new_session(self.next_ids.coord, coord_s.in_queue, coord_s.out_queue, config.CRD_TIMEOUT, self.facility)
|
||||
table.insert(self.sessions.coord, coord_s)
|
||||
|
||||
log.debug("established new coordinator session to " .. remote_port .. " with ID " .. self.next_coord_id)
|
||||
log.debug("established new coordinator session to " .. remote_port .. " with ID " .. self.next_ids.coord)
|
||||
|
||||
self.next_coord_id = self.next_coord_id + 1
|
||||
self.next_ids.coord = self.next_ids.coord + 1
|
||||
|
||||
-- success
|
||||
return coord_s.instance.get_id()
|
||||
@ -387,32 +387,49 @@ function svsessions.establish_coord_session(local_port, remote_port, version)
|
||||
end
|
||||
end
|
||||
|
||||
-- establish a new pocket diagnostics session
|
||||
---@nodiscard
|
||||
---@param local_port integer
|
||||
---@param remote_port integer
|
||||
---@param version string
|
||||
---@return integer|false session_id
|
||||
function svsessions.establish_diag_session(local_port, remote_port, version)
|
||||
---@class diag_session_struct
|
||||
local diag_s = {
|
||||
s_type = "pkt",
|
||||
open = true,
|
||||
version = version,
|
||||
l_port = local_port,
|
||||
r_port = remote_port,
|
||||
in_queue = mqueue.new(),
|
||||
out_queue = mqueue.new(),
|
||||
instance = nil ---@type diag_session
|
||||
}
|
||||
|
||||
diag_s.instance = pocket.new_session(self.next_ids.diag, diag_s.in_queue, diag_s.out_queue, config.PKT_TIMEOUT)
|
||||
table.insert(self.sessions.diag, diag_s)
|
||||
|
||||
log.debug("established new pocket diagnostics session to " .. remote_port .. " with ID " .. self.next_ids.diag)
|
||||
|
||||
self.next_ids.diag = self.next_ids.diag + 1
|
||||
|
||||
-- success
|
||||
return diag_s.instance.get_id()
|
||||
end
|
||||
|
||||
-- attempt to identify which session's watchdog timer fired
|
||||
---@param timer_event number
|
||||
function svsessions.check_all_watchdogs(timer_event)
|
||||
-- check RTU session watchdogs
|
||||
_check_watchdogs(self.rtu_sessions, timer_event)
|
||||
|
||||
-- check PLC session watchdogs
|
||||
_check_watchdogs(self.plc_sessions, timer_event)
|
||||
|
||||
-- check coordinator session watchdogs
|
||||
_check_watchdogs(self.coord_sessions, timer_event)
|
||||
for _, list in pairs(self.sessions) do _check_watchdogs(list, timer_event) end
|
||||
end
|
||||
|
||||
-- iterate all sessions
|
||||
-- iterate all sessions, and update facility/unit data & process control logic
|
||||
function svsessions.iterate_all()
|
||||
-- iterate RTU sessions
|
||||
_iterate(self.rtu_sessions)
|
||||
|
||||
-- iterate PLC sessions
|
||||
_iterate(self.plc_sessions)
|
||||
|
||||
-- iterate coordinator sessions
|
||||
_iterate(self.coord_sessions)
|
||||
-- iterate sessions
|
||||
for _, list in pairs(self.sessions) do _iterate(list) end
|
||||
|
||||
-- report RTU sessions to facility
|
||||
self.facility.report_rtus(self.rtu_sessions)
|
||||
self.facility.report_rtus(self.sessions.rtu)
|
||||
|
||||
-- iterate facility
|
||||
self.facility.update()
|
||||
@ -423,22 +440,15 @@ end
|
||||
|
||||
-- delete all closed sessions
|
||||
function svsessions.free_all_closed()
|
||||
-- free closed RTU sessions
|
||||
_free_closed(self.rtu_sessions)
|
||||
|
||||
-- free closed PLC sessions
|
||||
_free_closed(self.plc_sessions)
|
||||
|
||||
-- free closed coordinator sessions
|
||||
_free_closed(self.coord_sessions)
|
||||
for _, list in pairs(self.sessions) do _free_closed(list) end
|
||||
end
|
||||
|
||||
-- close all open connections
|
||||
function svsessions.close_all()
|
||||
-- close sessions
|
||||
_close(self.rtu_sessions)
|
||||
_close(self.plc_sessions)
|
||||
_close(self.coord_sessions)
|
||||
for _, list in pairs(self.sessions) do
|
||||
_close(list)
|
||||
end
|
||||
|
||||
-- free sessions
|
||||
svsessions.free_all_closed()
|
||||
|
@ -14,7 +14,7 @@ local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v0.14.5"
|
||||
local SUPERVISOR_VERSION = "v0.15.0"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
@ -34,6 +34,8 @@ cfv.assert_type_num(config.RTU_TIMEOUT)
|
||||
cfv.assert_min(config.RTU_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.CRD_TIMEOUT)
|
||||
cfv.assert_min(config.CRD_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.PKT_TIMEOUT)
|
||||
cfv.assert_min(config.PKT_TIMEOUT, 2)
|
||||
cfv.assert_type_int(config.NUM_REACTORS)
|
||||
cfv.assert_type_table(config.REACTOR_COOLING)
|
||||
cfv.assert_type_str(config.LOG_PATH)
|
||||
|
Loading…