@ -431,40 +431,48 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
if self.linked then
if packet.type == RPLC_TYPES.KEEP_ALIVE then
-- keep alive request received, echo back
local timestamp = packet.data[1]
local trip_time = util.time() - timestamp
if packet.length == 1 then
local timestamp = packet.data[1]
local trip_time = util.time() - timestamp
if trip_time > 500 then
log._warning("PLC KEEP_ALIVE trip time > 500ms (" .. trip_time .. ")")
if trip_time > 500 then
log._warning("PLC KEEP_ALIVE trip time > 500ms (" .. trip_time .. ")")
end
-- log._debug("RPLC RTT = ".. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
else
log._debug(log_header .. "RPLC keep alive packet length mismatch")
end
-- log._debug("RPLC RTT = ".. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
elseif packet.type == RPLC_TYPES.LINK_REQ then
-- link request confirmation
log._debug("received unsolicited link request response")
if packet.length == 1 then
log._debug("received unsolicited link request response")
local link_ack = packet.data[1]
if link_ack == RPLC_LINKING.ALLOW then
_send_struct()
send_status(plc_state.degraded)
log._debug("re-sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then
-- @todo: make sure this doesn't become a MITM security risk
println_ts("received unsolicited link denial, unlinking")
log._debug("unsolicited RPLC link request denied")
elseif link_ack == RPLC_LINKING.COLLISION then
-- @todo: make sure this doesn't become a MITM security risk
println_ts("received unsolicited link collision, unlinking")
log._warning("unsolicited RPLC link request collision")
local link_ack = packet.data[1]
if link_ack == RPLC_LINKING.ALLOW then
_send_struct()
send_status(plc_state.degraded)
log._debug("re-sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then
-- @todo: make sure this doesn't become a MITM security risk
println_ts("received unsolicited link denial, unlinking")
log._debug("unsolicited RPLC link request denied")
elseif link_ack == RPLC_LINKING.COLLISION then
-- @todo: make sure this doesn't become a MITM security risk
println_ts("received unsolicited link collision, unlinking")
log._warning("unsolicited RPLC link request collision")
else
println_ts("invalid unsolicited link response")
log._error("unsolicited unknown RPLC link request response")
end
self.linked = link_ack == RPLC_LINKING.ALLOW
else
println_ts("invalid unsolicited link response")
log._error("unsolicited unknown RPLC link request response")
log._debug(log_header .. "RPLC link req packet length mismatch")
end
self.linked = link_ack == RPLC_LINKING.ALLOW
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
-- request for physical structure
_send_struct()
@ -482,25 +490,29 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
_send_ack(packet.type, self.reactor.__p_is_ok())
elseif packet.type == RPLC_TYPES.MEK_BURN_RATE then
-- set the burn rate
local success = false
local burn_rate = packet.data[1]
local max_burn_rate = self.max_burn_rate
if packet.length == 1 then
local success = false
local burn_rate = packet.data[1]
local max_burn_rate = self.max_burn_rate
-- if no known max burn rate, check again
if max_burn_rate == nil then
max_burn_rate = self.reactor.getMaxBurnRate()
self.max_burn_rate = max_burn_rate
end
-- if we know our max burn rate, update current burn rate if in range
if max_burn_rate ~= ppm.ACCESS_FAULT then
if burn_rate > 0 and burn_rate <= max_burn_rate then
self.reactor.setBurnRate(burn_rate)
success = self.reactor.__p_is_ok()
-- if no known max burn rate, check again
if max_burn_rate == nil then
max_burn_rate = self.reactor.getMaxBurnRate()
self.max_burn_rate = max_burn_rate
end
end
_send_ack(packet.type, success)
-- if we know our max burn rate, update current burn rate if in range
if max_burn_rate ~= ppm.ACCESS_FAULT then
if burn_rate > 0 and burn_rate <= max_burn_rate then
self.reactor.setBurnRate(burn_rate)
success = self.reactor.__p_is_ok()
end
end
_send_ack(packet.type, success)
else
log._debug(log_header .. "RPLC set burn rate packet length mismatch")
end
elseif packet.type == RPLC_TYPES.ISS_CLEAR then
-- clear the ISS status
iss.reset()
@ -510,31 +522,35 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
end
elseif packet.type == RPLC_TYPES.LINK_REQ then
-- link request confirmation
local link_ack = packet.data[1]
if link_ack == RPLC_LINKING.ALLOW then
println_ts("linked!")
log._debug("RPLC link request approved")
if packet.length == 1 then
local link_ack = packet.data[1]
-- reset remote sequence number
self.r_seq_num = nil
if link_ack == RPLC_LINKING.ALLOW then
println_ts("linked!")
log._debug("RPLC link request approved")
_send_struct()
send_status(plc_state.degraded)
-- reset remote sequence number
self.r_seq_num = nil
log._debug("sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then
println_ts("link request denied, retrying...")
log._debug("RPLC link request denied")
elseif link_ack == RPLC_LINKING.COLLISION then
println_ts("reactor PLC ID collision (check config), retrying...")
log._warning("RPLC link request collision")
_send_struct()
send_status(plc_state.degraded)
log._debug("sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then
println_ts("link request denied, retrying...")
log._debug("RPLC link request denied")
elseif link_ack == RPLC_LINKING.COLLISION then
println_ts("reactor PLC ID collision (check config), retrying...")
log._warning("RPLC link request collision")
else
println_ts("invalid link response, bad channel? retrying...")
log._error("unknown RPLC link request response")
end
self.linked = link_ack == RPLC_LINKING.ALLOW
else
println_ts("invalid link response, bad channel? retrying...")
log._error("unknown RPLC link request response")
log._debug(log_header .. "RPLC link req packet length mismatch")
end
self.linked = link_ack == RPLC_LINKING.ALLOW
else
log._debug("discarding non-link packet before linked")
end

View File

@ -12,7 +12,7 @@ os.loadAPI("config.lua")
os.loadAPI("plc.lua")
os.loadAPI("threads.lua")
local R_PLC_VERSION = "alpha-v0.4.7"
local R_PLC_VERSION = "alpha-v0.4.8"
local print = util.print
local println = util.println