@ -801,7 +801,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
|
||||
local burn_rate = 0.0
|
||||
|
||||
if type(status) ~= "table" or #status ~= 5 then
|
||||
if type(status) ~= "table" or #status ~= 6 then
|
||||
log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)")
|
||||
valid = false
|
||||
else
|
||||
@ -1122,6 +1122,30 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
valid = false
|
||||
end
|
||||
|
||||
-- valve states
|
||||
local valve_states = status[6]
|
||||
|
||||
if type(valve_states) == "table" then
|
||||
if #valve_states == 5 then
|
||||
unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0)
|
||||
unit.unit_ps.publish("V_pu_state", valve_states[1] == 2)
|
||||
unit.unit_ps.publish("V_po_conn", valve_states[2] > 0)
|
||||
unit.unit_ps.publish("V_po_state", valve_states[2] == 2)
|
||||
unit.unit_ps.publish("V_pl_conn", valve_states[3] > 0)
|
||||
unit.unit_ps.publish("V_pl_state", valve_states[3] == 2)
|
||||
unit.unit_ps.publish("V_am_conn", valve_states[4] > 0)
|
||||
unit.unit_ps.publish("V_am_state", valve_states[4] == 2)
|
||||
unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0)
|
||||
unit.unit_ps.publish("V_emc_state", valve_states[5] == 2)
|
||||
else
|
||||
log.debug(log_header .. "valve states length mismatch")
|
||||
valid = false
|
||||
end
|
||||
else
|
||||
log.debug(log_header .. "valve states not a table")
|
||||
valid = false
|
||||
end
|
||||
|
||||
-- determine waste production for this unit, add to statistics
|
||||
|
||||
local is_pu = unit.waste_product == types.WASTE_PRODUCT.PLUTONIUM
|
||||
|
@ -45,6 +45,7 @@ local function make(parent, x, y, wide, unit)
|
||||
|
||||
local v_start = 1 + ((unit.unit_id - 1) * 4)
|
||||
local prv_start = 1 + ((unit.unit_id - 1) * 3)
|
||||
local v_fields = { "pu", "po", "pl", "am" }
|
||||
local v_names = {
|
||||
sprintf("PV%02d-PU", v_start),
|
||||
sprintf("PV%02d-PO", v_start + 1),
|
||||
@ -169,7 +170,9 @@ local function make(parent, x, y, wide, unit)
|
||||
local function _valve(vx, vy, n)
|
||||
TextBox{parent=waste,x=vx,y=vy,text="\x10\x11",fg_bg=text_c,width=2,height=1}
|
||||
local conn = IndicatorLight{parent=waste,x=vx-3,y=vy+1,label=v_names[n],colors=ind_grn}
|
||||
local state = IndicatorLight{parent=waste,x=vx-3,y=vy+2,label="STATE",colors=ind_wht}
|
||||
local open = IndicatorLight{parent=waste,x=vx-3,y=vy+2,label="OPEN",colors=ind_wht}
|
||||
conn.register(unit.unit_ps, util.c("V_", v_fields[n], "_conn"), conn.update)
|
||||
open.register(unit.unit_ps, util.c("V_", v_fields[n], "_state"), open.update)
|
||||
end
|
||||
|
||||
local function _machine(mx, my, name)
|
||||
|
@ -254,7 +254,10 @@ local function init(main)
|
||||
TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=cpair(colors.black,colors.lightGray),width=2,height=1}
|
||||
|
||||
local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", i + 13),colors=cpair(colors.green,colors.gray)}
|
||||
local state = IndicatorLight{parent=main,x=9,y=vy+2,label="STATE",colors=cpair(colors.white,colors.white)}
|
||||
local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=cpair(colors.white,colors.gray)}
|
||||
|
||||
conn.register(units[i].unit_ps, "V_emc_conn", conn.update)
|
||||
open.register(units[i].unit_ps, "V_emc_state", open.update)
|
||||
end
|
||||
end
|
||||
|
||||
|
@ -172,7 +172,8 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
|
||||
unit.get_rtu_statuses(),
|
||||
unit.get_annunciator(),
|
||||
unit.get_alarms(),
|
||||
unit.get_state()
|
||||
unit.get_state(),
|
||||
unit.get_valves()
|
||||
}
|
||||
end
|
||||
|
||||
|
@ -11,6 +11,18 @@ function rsctl.new(redstone_rtus)
|
||||
---@class rs_controller
|
||||
local public = {}
|
||||
|
||||
-- check if a redstone port has available connections
|
||||
---@param port IO_PORT
|
||||
---@return boolean
|
||||
function public.is_connected(port)
|
||||
for i = 1, #redstone_rtus do
|
||||
local db = redstone_rtus[i].get_db() ---@type redstone_session_db
|
||||
if db.io[port] ~= nil then return true end
|
||||
end
|
||||
|
||||
return false
|
||||
end
|
||||
|
||||
-- write to a digital redstone port (applies to all RTUs)
|
||||
---@param port IO_PORT
|
||||
---@param value boolean
|
||||
|
@ -333,14 +333,28 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
--#region redstone I/O
|
||||
|
||||
local __rs_w = self.io_ctl.digital_write
|
||||
-- create a generic valve interface
|
||||
---@nodiscard
|
||||
---@param port IO_PORT
|
||||
local function _make_valve_iface(port)
|
||||
---@class unit_valve_iface
|
||||
local iface = {
|
||||
open = function () self.io_ctl.digital_write(port, true) end,
|
||||
close = function () self.io_ctl.digital_write(port, false) end,
|
||||
-- check valve state
|
||||
---@nodiscard
|
||||
---@return 0|1|2 0 for not connected, 1 for inactive, 2 for active
|
||||
check = function () return util.trinary(self.io_ctl.is_connected(port), util.trinary(self.io_ctl.digital_read(port), 2, 1), 0) end
|
||||
}
|
||||
return iface
|
||||
end
|
||||
|
||||
-- valves
|
||||
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
|
||||
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
|
||||
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
|
||||
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
|
||||
local emer_cool = { open = function () __rs_w(IO.U_EMER_COOL, true) end, close = function () __rs_w(IO.U_EMER_COOL, false) end }
|
||||
local waste_pu = _make_valve_iface(IO.WASTE_PU)
|
||||
local waste_sna = _make_valve_iface(IO.WASTE_PO)
|
||||
local waste_po = _make_valve_iface(IO.WASTE_POPL)
|
||||
local waste_sps = _make_valve_iface(IO.WASTE_AM)
|
||||
local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
|
||||
|
||||
---@class unit_valves
|
||||
self.valves = {
|
||||
@ -869,6 +883,19 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
}
|
||||
end
|
||||
|
||||
-- get valve states
|
||||
---@nodiscard
|
||||
function public.get_valves()
|
||||
local v = self.valves
|
||||
return {
|
||||
v.waste_pu.check(),
|
||||
v.waste_sna.check(),
|
||||
v.waste_po.check(),
|
||||
v.waste_sps.check(),
|
||||
v.emer_cool.check()
|
||||
}
|
||||
end
|
||||
|
||||
-- get the reactor ID
|
||||
---@nodiscard
|
||||
function public.get_id() return self.r_id end
|
||||
|