mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
broke up comms file, setup base coordinator code
This commit is contained in:
parent
2ee503946c
commit
5eaeb50000
8
coordinator/coordinator.lua
Normal file
8
coordinator/coordinator.lua
Normal file
@ -0,0 +1,8 @@
|
||||
-- #REQUIRES comms.lua
|
||||
|
||||
-- coordinator communications
|
||||
function coord_comms()
|
||||
local self = {
|
||||
reactor_struct_cache = nil
|
||||
}
|
||||
end
|
27
coordinator/startup.lua
Normal file
27
coordinator/startup.lua
Normal file
@ -0,0 +1,27 @@
|
||||
--
|
||||
-- Nuclear Generation Facility SCADA Coordinator
|
||||
--
|
||||
|
||||
os.loadAPI("scada-common/log.lua")
|
||||
os.loadAPI("scada-common/util.lua")
|
||||
os.loadAPI("scada-common/ppm.lua")
|
||||
os.loadAPI("scada-common/comms.lua")
|
||||
|
||||
os.loadAPI("coordinator/config.lua")
|
||||
os.loadAPI("coordinator/coordinator.lua")
|
||||
|
||||
local COORDINATOR_VERSION = "alpha-v0.1.0"
|
||||
|
||||
local print_ts = util.print_ts
|
||||
|
||||
ppm.mount_all()
|
||||
|
||||
local modem = ppm.get_device("modem")
|
||||
|
||||
print("| SCADA Coordinator - " .. COORDINATOR_VERSION .. " |")
|
||||
|
||||
-- we need a modem
|
||||
if modem == nil then
|
||||
print("Please connect a modem.")
|
||||
return
|
||||
end
|
@ -1,3 +1,5 @@
|
||||
-- #REQUIRES comms.lua
|
||||
|
||||
function scada_link(plc_comms)
|
||||
local linked = false
|
||||
local link_timeout = os.startTimer(5)
|
||||
@ -169,3 +171,192 @@ function iss_init(reactor)
|
||||
timed_out = timed_out
|
||||
}
|
||||
end
|
||||
|
||||
-- reactor PLC communications
|
||||
function rplc_comms(id, modem, local_port, server_port, reactor)
|
||||
local self = {
|
||||
id = id,
|
||||
seq_num = 0,
|
||||
modem = modem,
|
||||
s_port = server_port,
|
||||
l_port = local_port,
|
||||
reactor = reactor,
|
||||
status_cache = nil
|
||||
}
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send = function (msg)
|
||||
local packet = scada_packet()
|
||||
packet.make(self.seq_num, PROTOCOLS.RPLC, msg)
|
||||
self.modem.transmit(self.s_port, self.l_port, packet.raw())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- variable reactor status information, excluding heating rate
|
||||
local _reactor_status = function ()
|
||||
return {
|
||||
status = self.reactor.getStatus(),
|
||||
burn_rate = self.reactor.getBurnRate(),
|
||||
act_burn_r = self.reactor.getActualBurnRate(),
|
||||
temp = self.reactor.getTemperature(),
|
||||
damage = self.reactor.getDamagePercent(),
|
||||
boil_eff = self.reactor.getBoilEfficiency(),
|
||||
env_loss = self.reactor.getEnvironmentalLoss(),
|
||||
|
||||
fuel = self.reactor.getFuel(),
|
||||
fuel_need = self.reactor.getFuelNeeded(),
|
||||
fuel_fill = self.reactor.getFuelFilledPercentage(),
|
||||
waste = self.reactor.getWaste(),
|
||||
waste_need = self.reactor.getWasteNeeded(),
|
||||
waste_fill = self.reactor.getWasteFilledPercentage(),
|
||||
cool_type = self.reactor.getCoolant()['name'],
|
||||
cool_amnt = self.reactor.getCoolant()['amount'],
|
||||
cool_need = self.reactor.getCoolantNeeded(),
|
||||
cool_fill = self.reactor.getCoolantFilledPercentage(),
|
||||
hcool_type = self.reactor.getHeatedCoolant()['name'],
|
||||
hcool_amnt = self.reactor.getHeatedCoolant()['amount'],
|
||||
hcool_need = self.reactor.getHeatedCoolantNeeded(),
|
||||
hcool_fill = self.reactor.getHeatedCoolantFilledPercentage()
|
||||
}
|
||||
end
|
||||
|
||||
local _update_status_cache = function ()
|
||||
local status = _reactor_status()
|
||||
local changed = false
|
||||
|
||||
for key, value in pairs(status) do
|
||||
if value ~= self.status_cache[key] then
|
||||
changed = true
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
if changed then
|
||||
self.status_cache = status
|
||||
end
|
||||
|
||||
return changed
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- parse an RPLC packet
|
||||
local parse_packet = function(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = scada_packet()
|
||||
|
||||
-- parse packet as generic SCADA packet
|
||||
s_pkt.recieve(side, sender, reply_to, message, distance)
|
||||
|
||||
-- get using RPLC protocol format
|
||||
if s_pkt.is_valid() and s_pkt.protocol() == PROTOCOLS.RPLC then
|
||||
local body = s_pkt.data()
|
||||
if #body > 2 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
id = body[1],
|
||||
type = body[2],
|
||||
length = #body - 2,
|
||||
body = { table.unpack(body, 3, 2 + #body) }
|
||||
}
|
||||
end
|
||||
end
|
||||
|
||||
return pkt
|
||||
end
|
||||
|
||||
-- handle a linking packet
|
||||
local handle_link = function (packet)
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
return packet.data[1] == RPLC_LINKING.ALLOW
|
||||
else
|
||||
return nil
|
||||
end
|
||||
end
|
||||
|
||||
-- handle an RPLC packet
|
||||
local handle_packet = function (packet)
|
||||
if packet.type == RPLC_TYPES.KEEP_ALIVE then
|
||||
-- keep alive request received, nothing to do except feed watchdog
|
||||
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
|
||||
-- request for physical structure
|
||||
send_struct()
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_CONNS then
|
||||
-- request for redstone connections
|
||||
send_rs_io_conns()
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_GET then
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_SET then
|
||||
elseif packet.type == RPLC_TYPES.MEK_SCRAM then
|
||||
elseif packet.type == RPLC_TYPES.MEK_ENABLE then
|
||||
elseif packet.type == RPLC_TYPES.MEK_BURN_RATE then
|
||||
elseif packet.type == RPLC_TYPES.ISS_GET then
|
||||
elseif packet.type == RPLC_TYPES.ISS_CLEAR then
|
||||
end
|
||||
end
|
||||
|
||||
-- attempt to establish link with supervisor
|
||||
local send_link_req = function ()
|
||||
local linking_data = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.LINK_REQ
|
||||
}
|
||||
|
||||
_send(linking_data)
|
||||
end
|
||||
|
||||
-- send structure properties (these should not change)
|
||||
-- (server will cache these)
|
||||
local send_struct = function ()
|
||||
local mek_data = {
|
||||
heat_cap = self.reactor.getHeatCapacity(),
|
||||
fuel_asm = self.reactor.getFuelAssemblies(),
|
||||
fuel_sa = self.reactor.getFuelSurfaceArea(),
|
||||
fuel_cap = self.reactor.getFuelCapacity(),
|
||||
waste_cap = self.reactor.getWasteCapacity(),
|
||||
cool_cap = self.reactor.getCoolantCapacity(),
|
||||
hcool_cap = self.reactor.getHeatedCoolantCapacity(),
|
||||
max_burn = self.reactor.getMaxBurnRate()
|
||||
}
|
||||
|
||||
local struct_packet = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.MEK_STRUCT,
|
||||
mek_data = mek_data
|
||||
}
|
||||
|
||||
_send(struct_packet)
|
||||
end
|
||||
|
||||
-- send live status information
|
||||
-- control_state : acknowledged control state from supervisor
|
||||
-- overridden : if ISS force disabled reactor
|
||||
local send_status = function (control_state, overridden)
|
||||
local mek_data = nil
|
||||
|
||||
if _update_status_cache() then
|
||||
mek_data = self.status_cache
|
||||
end
|
||||
|
||||
local sys_status = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.STATUS,
|
||||
timestamp = os.time(),
|
||||
control_state = control_state,
|
||||
overridden = overridden,
|
||||
heating_rate = self.reactor.getHeatingRate(),
|
||||
mek_data = mek_data
|
||||
}
|
||||
|
||||
_send(sys_status)
|
||||
end
|
||||
|
||||
return {
|
||||
parse_packet = parse_packet,
|
||||
handle_link = handle_link,
|
||||
handle_packet = handle_packet,
|
||||
send_link_req = send_link_req,
|
||||
send_struct = send_struct,
|
||||
send_status = send_status
|
||||
}
|
||||
end
|
||||
|
@ -42,7 +42,7 @@ if not modem.isOpen(config.LISTEN_PORT) then
|
||||
modem.open(config.LISTEN_PORT)
|
||||
end
|
||||
|
||||
local plc_comms = comms.rplc_comms(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor)
|
||||
local plc_comms = plc.rplc_comms(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor)
|
||||
|
||||
-- attempt server connection
|
||||
-- exit application if connection is denied
|
||||
|
165
rtu/rtu.lua
165
rtu/rtu.lua
@ -1,3 +1,6 @@
|
||||
-- #REQUIRES comms.lua
|
||||
-- #REQUIRES modbus.lua
|
||||
|
||||
function rtu_init()
|
||||
local self = {
|
||||
discrete_inputs = {},
|
||||
@ -85,3 +88,165 @@ function rtu_init()
|
||||
write_holding_reg = write_holding_reg
|
||||
}
|
||||
end
|
||||
|
||||
function rtu_comms(modem, local_port, server_port)
|
||||
local self = {
|
||||
seq_num = 0,
|
||||
txn_id = 0,
|
||||
modem = modem,
|
||||
s_port = server_port,
|
||||
l_port = local_port
|
||||
}
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send = function (protocol, msg)
|
||||
local packet = scada_packet()
|
||||
packet.make(self.seq_num, protocol, msg)
|
||||
self.modem.transmit(self.s_port, self.l_port, packet.raw())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- parse a MODBUS/SCADA packet
|
||||
local parse_packet = function(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = scada_packet()
|
||||
|
||||
-- parse packet as generic SCADA packet
|
||||
s_pkt.recieve(side, sender, reply_to, message, distance)
|
||||
|
||||
if s_pkt.is_valid() then
|
||||
-- get as MODBUS TCP packet
|
||||
if s_pkt.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
local m_pkt = modbus_packet()
|
||||
m_pkt.receive(s_pkt.data())
|
||||
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
modbus_frame = m_pkt
|
||||
}
|
||||
-- get as SCADA management packet
|
||||
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
local body = s_pkt.data()
|
||||
if #body > 1 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
type = body[1],
|
||||
length = #body - 1,
|
||||
body = { table.unpack(body, 2, 1 + #body) }
|
||||
}
|
||||
elseif #body == 1 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
type = body[1],
|
||||
length = #body - 1,
|
||||
body = nil
|
||||
}
|
||||
else
|
||||
log._error("Malformed SCADA packet has no length field")
|
||||
end
|
||||
else
|
||||
log._error("Illegal packet type " .. s_pkt.protocol(), true)
|
||||
end
|
||||
end
|
||||
|
||||
return pkt
|
||||
end
|
||||
|
||||
local handle_packet = function(packet, units, ref)
|
||||
if packet ~= nil then
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
if protocol == PROTOCOLS.MODBUS_TCP then
|
||||
-- MODBUS instruction
|
||||
if packet.modbus_frame.unit_id <= #units then
|
||||
local return_code, response = units.modbus_io.handle_packet(packet.modbus_frame)
|
||||
_send(response, PROTOCOLS.MODBUS_TCP)
|
||||
|
||||
if not return_code then
|
||||
log._warning("MODBUS operation failed")
|
||||
end
|
||||
else
|
||||
-- unit ID out of range?
|
||||
log._error("MODBUS packet requesting non-existent unit")
|
||||
end
|
||||
elseif protocol == PROTOCOLS.SCADA_MGMT then
|
||||
-- SCADA management packet
|
||||
if packet.type == SCADA_MGMT_TYPES.REMOTE_LINKED then
|
||||
-- acknowledgement
|
||||
ref.linked = true
|
||||
elseif packet.type == SCADA_MGMT_TYPES.RTU_ADVERT then
|
||||
-- request for capabilities again
|
||||
send_advertisement(units)
|
||||
else
|
||||
-- not supported
|
||||
log._warning("RTU got unexpected SCADA message type " .. packet.type, true)
|
||||
end
|
||||
else
|
||||
-- should be unreachable assuming packet is from parse_packet()
|
||||
log._error("Illegal packet type " .. protocol, true)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- send capability advertisement
|
||||
local send_advertisement = function (units)
|
||||
local advertisement = {
|
||||
type = SCADA_MGMT_TYPES.RTU_ADVERT,
|
||||
units = {}
|
||||
}
|
||||
|
||||
for i = 1, #units do
|
||||
local type = nil
|
||||
|
||||
if units[i].type == "boiler" then
|
||||
type = RTU_ADVERT_TYPES.BOILER
|
||||
elseif units[i].type == "turbine" then
|
||||
type = RTU_ADVERT_TYPES.TURBINE
|
||||
elseif units[i].type == "imatrix" then
|
||||
type = RTU_ADVERT_TYPES.IMATRIX
|
||||
elseif units[i].type == "redstone" then
|
||||
type = RTU_ADVERT_TYPES.REDSTONE
|
||||
end
|
||||
|
||||
if type ~= nil then
|
||||
if type == RTU_ADVERT_TYPES.REDSTONE then
|
||||
table.insert(advertisement.units, {
|
||||
unit = i,
|
||||
type = type,
|
||||
index = units[i].index,
|
||||
reactor = units[i].for_reactor,
|
||||
rsio = units[i].device
|
||||
})
|
||||
else
|
||||
table.insert(advertisement.units, {
|
||||
unit = i,
|
||||
type = type,
|
||||
index = units[i].index,
|
||||
reactor = units[i].for_reactor,
|
||||
rsio = nil
|
||||
})
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
_send(advertisement, PROTOCOLS.SCADA_MGMT)
|
||||
end
|
||||
|
||||
local send_heartbeat = function ()
|
||||
local heartbeat = {
|
||||
type = SCADA_MGMT_TYPES.RTU_HEARTBEAT
|
||||
}
|
||||
|
||||
_send(heartbeat, PROTOCOLS.SCADA_MGMT)
|
||||
end
|
||||
|
||||
return {
|
||||
parse_packet = parse_packet,
|
||||
handle_packet = handle_packet,
|
||||
send_advertisement = send_advertisement,
|
||||
send_heartbeat = send_heartbeat
|
||||
}
|
||||
end
|
||||
|
@ -41,7 +41,7 @@ if not modem.isOpen(config.LISTEN_PORT) then
|
||||
modem.open(config.LISTEN_PORT)
|
||||
end
|
||||
|
||||
local rtu_comms = comms.rtu_comms(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor)
|
||||
local rtu_comms = rtu.rtu_comms(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor)
|
||||
|
||||
----------------------------------------
|
||||
-- determine configuration
|
||||
|
@ -1,5 +1,3 @@
|
||||
-- #REQUIRES modbus.lua
|
||||
|
||||
PROTOCOLS = {
|
||||
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
|
||||
RPLC = 1, -- reactor PLC protocol
|
||||
@ -116,375 +114,3 @@ function scada_packet()
|
||||
data = data
|
||||
}
|
||||
end
|
||||
|
||||
-- coordinator communications
|
||||
function coord_comms()
|
||||
local self = {
|
||||
reactor_struct_cache = nil
|
||||
}
|
||||
end
|
||||
|
||||
-- supervisory controller communications
|
||||
function superv_comms(mode, num_reactors, modem, dev_listen, fo_channel, sv_channel)
|
||||
local self = {
|
||||
mode = mode,
|
||||
seq_num = 0,
|
||||
num_reactors = num_reactors,
|
||||
modem = modem,
|
||||
dev_listen = dev_listen,
|
||||
fo_channel = fo_channel,
|
||||
sv_channel = sv_channel,
|
||||
reactor_struct_cache = nil
|
||||
}
|
||||
end
|
||||
|
||||
function rtu_comms(modem, local_port, server_port)
|
||||
local self = {
|
||||
seq_num = 0,
|
||||
txn_id = 0,
|
||||
modem = modem,
|
||||
s_port = server_port,
|
||||
l_port = local_port
|
||||
}
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send = function (protocol, msg)
|
||||
local packet = scada_packet()
|
||||
packet.make(self.seq_num, protocol, msg)
|
||||
self.modem.transmit(self.s_port, self.l_port, packet.raw())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- parse a MODBUS/SCADA packet
|
||||
local parse_packet = function(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = scada_packet()
|
||||
|
||||
-- parse packet as generic SCADA packet
|
||||
s_pkt.recieve(side, sender, reply_to, message, distance)
|
||||
|
||||
if s_pkt.is_valid() then
|
||||
-- get as MODBUS TCP packet
|
||||
if s_pkt.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
local m_pkt = modbus_packet()
|
||||
m_pkt.receive(s_pkt.data())
|
||||
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
modbus_frame = m_pkt
|
||||
}
|
||||
-- get as SCADA management packet
|
||||
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
local body = s_pkt.data()
|
||||
if #body > 1 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
type = body[1],
|
||||
length = #body - 1,
|
||||
body = { table.unpack(body, 2, 1 + #body) }
|
||||
}
|
||||
elseif #body == 1 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
type = body[1],
|
||||
length = #body - 1,
|
||||
body = nil
|
||||
}
|
||||
else
|
||||
log._error("Malformed SCADA packet has no length field")
|
||||
end
|
||||
else
|
||||
log._error("Illegal packet type " .. s_pkt.protocol(), true)
|
||||
end
|
||||
end
|
||||
|
||||
return pkt
|
||||
end
|
||||
|
||||
local handle_packet = function(packet, units, ref)
|
||||
if packet ~= nil then
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
if protocol == PROTOCOLS.MODBUS_TCP then
|
||||
-- MODBUS instruction
|
||||
if packet.modbus_frame.unit_id <= #units then
|
||||
local return_code, response = units.modbus_io.handle_packet(packet.modbus_frame)
|
||||
_send(response, PROTOCOLS.MODBUS_TCP)
|
||||
|
||||
if not return_code then
|
||||
log._warning("MODBUS operation failed")
|
||||
end
|
||||
else
|
||||
-- unit ID out of range?
|
||||
log._error("MODBUS packet requesting non-existent unit")
|
||||
end
|
||||
elseif protocol == PROTOCOLS.SCADA_MGMT then
|
||||
-- SCADA management packet
|
||||
if packet.type == SCADA_MGMT_TYPES.REMOTE_LINKED then
|
||||
-- acknowledgement
|
||||
ref.linked = true
|
||||
elseif packet.type == SCADA_MGMT_TYPES.RTU_ADVERT then
|
||||
-- request for capabilities again
|
||||
send_advertisement(units)
|
||||
else
|
||||
-- not supported
|
||||
log._warning("RTU got unexpected SCADA message type " .. packet.type, true)
|
||||
end
|
||||
else
|
||||
-- should be unreachable assuming packet is from parse_packet()
|
||||
log._error("Illegal packet type " .. protocol, true)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- send capability advertisement
|
||||
local send_advertisement = function (units)
|
||||
local advertisement = {
|
||||
type = SCADA_MGMT_TYPES.RTU_ADVERT,
|
||||
units = {}
|
||||
}
|
||||
|
||||
for i = 1, #units do
|
||||
local type = nil
|
||||
|
||||
if units[i].type == "boiler" then
|
||||
type = RTU_ADVERT_TYPES.BOILER
|
||||
elseif units[i].type == "turbine" then
|
||||
type = RTU_ADVERT_TYPES.TURBINE
|
||||
elseif units[i].type == "imatrix" then
|
||||
type = RTU_ADVERT_TYPES.IMATRIX
|
||||
elseif units[i].type == "redstone" then
|
||||
type = RTU_ADVERT_TYPES.REDSTONE
|
||||
end
|
||||
|
||||
if type ~= nil then
|
||||
if type == RTU_ADVERT_TYPES.REDSTONE then
|
||||
table.insert(advertisement.units, {
|
||||
unit = i,
|
||||
type = type,
|
||||
index = units[i].index,
|
||||
reactor = units[i].for_reactor,
|
||||
rsio = units[i].device
|
||||
})
|
||||
else
|
||||
table.insert(advertisement.units, {
|
||||
unit = i,
|
||||
type = type,
|
||||
index = units[i].index,
|
||||
reactor = units[i].for_reactor,
|
||||
rsio = nil
|
||||
})
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
_send(advertisement, PROTOCOLS.SCADA_MGMT)
|
||||
end
|
||||
|
||||
local send_heartbeat = function ()
|
||||
local heartbeat = {
|
||||
type = SCADA_MGMT_TYPES.RTU_HEARTBEAT
|
||||
}
|
||||
|
||||
_send(heartbeat, PROTOCOLS.SCADA_MGMT)
|
||||
end
|
||||
|
||||
return {
|
||||
parse_packet = parse_packet,
|
||||
handle_packet = handle_packet,
|
||||
send_advertisement = send_advertisement,
|
||||
send_heartbeat = send_heartbeat
|
||||
}
|
||||
end
|
||||
|
||||
-- reactor PLC communications
|
||||
function rplc_comms(id, modem, local_port, server_port, reactor)
|
||||
local self = {
|
||||
id = id,
|
||||
seq_num = 0,
|
||||
modem = modem,
|
||||
s_port = server_port,
|
||||
l_port = local_port,
|
||||
reactor = reactor,
|
||||
status_cache = nil
|
||||
}
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send = function (msg)
|
||||
local packet = scada_packet()
|
||||
packet.make(self.seq_num, PROTOCOLS.RPLC, msg)
|
||||
self.modem.transmit(self.s_port, self.l_port, packet.raw())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- variable reactor status information, excluding heating rate
|
||||
local _reactor_status = function ()
|
||||
return {
|
||||
status = self.reactor.getStatus(),
|
||||
burn_rate = self.reactor.getBurnRate(),
|
||||
act_burn_r = self.reactor.getActualBurnRate(),
|
||||
temp = self.reactor.getTemperature(),
|
||||
damage = self.reactor.getDamagePercent(),
|
||||
boil_eff = self.reactor.getBoilEfficiency(),
|
||||
env_loss = self.reactor.getEnvironmentalLoss(),
|
||||
|
||||
fuel = self.reactor.getFuel(),
|
||||
fuel_need = self.reactor.getFuelNeeded(),
|
||||
fuel_fill = self.reactor.getFuelFilledPercentage(),
|
||||
waste = self.reactor.getWaste(),
|
||||
waste_need = self.reactor.getWasteNeeded(),
|
||||
waste_fill = self.reactor.getWasteFilledPercentage(),
|
||||
cool_type = self.reactor.getCoolant()['name'],
|
||||
cool_amnt = self.reactor.getCoolant()['amount'],
|
||||
cool_need = self.reactor.getCoolantNeeded(),
|
||||
cool_fill = self.reactor.getCoolantFilledPercentage(),
|
||||
hcool_type = self.reactor.getHeatedCoolant()['name'],
|
||||
hcool_amnt = self.reactor.getHeatedCoolant()['amount'],
|
||||
hcool_need = self.reactor.getHeatedCoolantNeeded(),
|
||||
hcool_fill = self.reactor.getHeatedCoolantFilledPercentage()
|
||||
}
|
||||
end
|
||||
|
||||
local _update_status_cache = function ()
|
||||
local status = _reactor_status()
|
||||
local changed = false
|
||||
|
||||
for key, value in pairs(status) do
|
||||
if value ~= self.status_cache[key] then
|
||||
changed = true
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
if changed then
|
||||
self.status_cache = status
|
||||
end
|
||||
|
||||
return changed
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- parse an RPLC packet
|
||||
local parse_packet = function(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = scada_packet()
|
||||
|
||||
-- parse packet as generic SCADA packet
|
||||
s_pkt.recieve(side, sender, reply_to, message, distance)
|
||||
|
||||
-- get using RPLC protocol format
|
||||
if s_pkt.is_valid() and s_pkt.protocol() == PROTOCOLS.RPLC then
|
||||
local body = s_pkt.data()
|
||||
if #body > 2 then
|
||||
pkt = {
|
||||
scada_frame = s_pkt,
|
||||
id = body[1],
|
||||
type = body[2],
|
||||
length = #body - 2,
|
||||
body = { table.unpack(body, 3, 2 + #body) }
|
||||
}
|
||||
end
|
||||
end
|
||||
|
||||
return pkt
|
||||
end
|
||||
|
||||
-- handle a linking packet
|
||||
local handle_link = function (packet)
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
return packet.data[1] == RPLC_LINKING.ALLOW
|
||||
else
|
||||
return nil
|
||||
end
|
||||
end
|
||||
|
||||
-- handle an RPLC packet
|
||||
local handle_packet = function (packet)
|
||||
if packet.type == RPLC_TYPES.KEEP_ALIVE then
|
||||
-- keep alive request received, nothing to do except feed watchdog
|
||||
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
|
||||
-- request for physical structure
|
||||
send_struct()
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_CONNS then
|
||||
-- request for redstone connections
|
||||
send_rs_io_conns()
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_GET then
|
||||
elseif packet.type == RPLC_TYPES.RS_IO_SET then
|
||||
elseif packet.type == RPLC_TYPES.MEK_SCRAM then
|
||||
elseif packet.type == RPLC_TYPES.MEK_ENABLE then
|
||||
elseif packet.type == RPLC_TYPES.MEK_BURN_RATE then
|
||||
elseif packet.type == RPLC_TYPES.ISS_GET then
|
||||
elseif packet.type == RPLC_TYPES.ISS_CLEAR then
|
||||
end
|
||||
end
|
||||
|
||||
-- attempt to establish link with supervisor
|
||||
local send_link_req = function ()
|
||||
local linking_data = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.LINK_REQ
|
||||
}
|
||||
|
||||
_send(linking_data)
|
||||
end
|
||||
|
||||
-- send structure properties (these should not change)
|
||||
-- (server will cache these)
|
||||
local send_struct = function ()
|
||||
local mek_data = {
|
||||
heat_cap = self.reactor.getHeatCapacity(),
|
||||
fuel_asm = self.reactor.getFuelAssemblies(),
|
||||
fuel_sa = self.reactor.getFuelSurfaceArea(),
|
||||
fuel_cap = self.reactor.getFuelCapacity(),
|
||||
waste_cap = self.reactor.getWasteCapacity(),
|
||||
cool_cap = self.reactor.getCoolantCapacity(),
|
||||
hcool_cap = self.reactor.getHeatedCoolantCapacity(),
|
||||
max_burn = self.reactor.getMaxBurnRate()
|
||||
}
|
||||
|
||||
local struct_packet = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.MEK_STRUCT,
|
||||
mek_data = mek_data
|
||||
}
|
||||
|
||||
_send(struct_packet)
|
||||
end
|
||||
|
||||
-- send live status information
|
||||
-- control_state : acknowledged control state from supervisor
|
||||
-- overridden : if ISS force disabled reactor
|
||||
local send_status = function (control_state, overridden)
|
||||
local mek_data = nil
|
||||
|
||||
if _update_status_cache() then
|
||||
mek_data = self.status_cache
|
||||
end
|
||||
|
||||
local sys_status = {
|
||||
id = self.id,
|
||||
type = RPLC_TYPES.STATUS,
|
||||
timestamp = os.time(),
|
||||
control_state = control_state,
|
||||
overridden = overridden,
|
||||
heating_rate = self.reactor.getHeatingRate(),
|
||||
mek_data = mek_data
|
||||
}
|
||||
|
||||
_send(sys_status)
|
||||
end
|
||||
|
||||
return {
|
||||
parse_packet = parse_packet,
|
||||
handle_link = handle_link,
|
||||
handle_packet = handle_packet,
|
||||
send_link_req = send_link_req,
|
||||
send_struct = send_struct,
|
||||
send_status = send_status
|
||||
}
|
||||
end
|
||||
|
Loading…
Reference in New Issue