mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#512 increased clarity of peripheral assignments
This commit is contained in:
parent
3762e9dced
commit
715765d442
@ -158,7 +158,6 @@ local tool_ctl = {
|
||||
p_idx = nil, ---@type graphics_element
|
||||
p_unit = nil, ---@type graphics_element
|
||||
p_assign_btn = nil, ---@type graphics_element
|
||||
p_assign_end = nil, ---@type graphics_element
|
||||
p_desc = nil, ---@type graphics_element
|
||||
p_desc_ext = nil, ---@type graphics_element
|
||||
p_err = nil, ---@type graphics_element
|
||||
@ -828,53 +827,35 @@ local function config_view(display)
|
||||
tool_ctl.p_name_msg.set_value("Configuring peripheral on '" .. name .. "':")
|
||||
tool_ctl.p_desc_ext.set_value("")
|
||||
|
||||
if type == "boilerValve" then
|
||||
tool_ctl.p_prompt.set_value("This is the # boiler for reactor unit # .")
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
local function reposition(prompt, idx_x, idx_max, unit_x, unit_y, desc_y)
|
||||
tool_ctl.p_prompt.set_value(prompt)
|
||||
tool_ctl.p_idx.reposition(idx_x, 4)
|
||||
tool_ctl.p_idx.enable()
|
||||
tool_ctl.p_idx.set_max(2)
|
||||
tool_ctl.p_unit.reposition(44, 4)
|
||||
tool_ctl.p_idx.set_max(idx_max)
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_unit.reposition(unit_x, unit_y)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
tool_ctl.p_desc.reposition(1, desc_y)
|
||||
end
|
||||
|
||||
if type == "boilerValve" then
|
||||
reposition("This is reactor unit # 's # boiler.", 31, 2, 23, 4, 7)
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
tool_ctl.p_desc.set_value("Each unit can have at most 2 boilers. Boiler #1 shows up first on the main display, followed by boiler #2 below it. These numberings are independent of which RTU they are connected to. For example, one RTU can have boiler #1 and another can have #2, but both cannot have #1.")
|
||||
elseif type == "turbineValve" then
|
||||
tool_ctl.p_prompt.set_value("This is the # turbine for reactor unit # .")
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.enable()
|
||||
tool_ctl.p_idx.set_max(3)
|
||||
tool_ctl.p_unit.reposition(45, 4)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
reposition("This is reactor unit # 's # turbine.", 31, 3, 23, 4, 7)
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
tool_ctl.p_desc.set_value("Each unit can have at most 3 turbines. Turbine #1 shows up first on the main display, followed by #2 then #3 below it. These numberings are independent of which RTU they are connected to. For example, one RTU can have turbine #1 and another can have #2, but both cannot have #1.")
|
||||
elseif type == "solarNeutronActivator" then
|
||||
reposition("This SNA is for reactor unit # .", 46, 1, 31, 4, 7)
|
||||
tool_ctl.p_idx.hide()
|
||||
tool_ctl.p_prompt.set_value("This SNA is for reactor unit # .")
|
||||
tool_ctl.p_unit.reposition(31, 4)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc_ext.set_value("Before adding lots of SNAs: multiply the \"PEAK\" rate on the flow monitor (after connecting at least 1 SNA) by 10 to get the mB/t of waste that they can process. Enough SNAs to provide 2x to 3x of your max burn rate should be a good margin to catch up after night or cloudy weather. Too many devices (such as SNAs) on one RTU can cause lag.")
|
||||
elseif type == "dynamicValve" then
|
||||
tool_ctl.p_prompt.set_value("This is the # dynamic tank for...")
|
||||
reposition("This is the below system's # dynamic tank.", 29, 4, 17, 6, 8)
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(4)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then
|
||||
tool_ctl.p_idx.enable()
|
||||
@ -885,22 +866,12 @@ local function config_view(display)
|
||||
tool_ctl.p_unit.enable()
|
||||
end
|
||||
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("Each reactor unit can have at most 1 tank and the facility can have at most 4. Each facility tank must have a unique # 1 through 4, regardless of where it is connected. Only a total of 4 tanks can be displayed on the flow monitor.")
|
||||
elseif type == "environmentDetector" then
|
||||
tool_ctl.p_prompt.set_value("This is the # environment detector for...")
|
||||
reposition("This is the below system's # env. detector.", 29, 99, 17, 6, 8)
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(99)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then tool_ctl.p_unit.disable() else tool_ctl.p_unit.enable() end
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility. In that case, the maximum radiation reading from those assigned to that particular unit or the facility will be used for alarms and display.")
|
||||
elseif type == "inductionPort" or type == "spsPort" then
|
||||
local dev = tri(type == "inductionPort", "induction matrix", "SPS")
|
||||
@ -908,7 +879,6 @@ local function config_view(display)
|
||||
tool_ctl.p_unit.hide(true)
|
||||
tool_ctl.p_prompt.set_value("This is the " .. dev .. " for the facility.")
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
tool_ctl.p_desc.set_value("There can only be one of these devices per SCADA network, so it will be assigned as the sole " .. dev .. " for the facility. There must only be one of these across all the RTUs you have.")
|
||||
else
|
||||
@ -965,11 +935,10 @@ local function config_view(display)
|
||||
|
||||
tool_ctl.p_name_msg = TextBox{parent=peri_c_4,x=1,y=1,height=2,text=""}
|
||||
tool_ctl.p_prompt = TextBox{parent=peri_c_4,x=1,y=4,height=2,text=""}
|
||||
tool_ctl.p_idx = NumberField{parent=peri_c_4,x=14,y=4,width=4,max_chars=2,min=1,max=2,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_assign_btn = RadioButton{parent=peri_c_4,x=1,y=5,default=1,options={"the facility.","a unit. (unit #"},callback=function(v)tool_ctl.p_assign(v)end,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.purple}
|
||||
tool_ctl.p_assign_end = TextBox{parent=peri_c_4,x=22,y=6,height=6,width=1,text=")"}
|
||||
tool_ctl.p_idx = NumberField{parent=peri_c_4,x=31,y=4,width=4,max_chars=2,min=1,max=2,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_assign_btn = RadioButton{parent=peri_c_4,x=1,y=5,default=1,options={"the facility","reactor unit #"},callback=function(v)tool_ctl.p_assign(v)end,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.purple}
|
||||
|
||||
tool_ctl.p_unit = NumberField{parent=peri_c_4,x=44,y=4,width=4,max_chars=2,min=1,max=4,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_unit = NumberField{parent=peri_c_4,x=23,y=4,width=4,max_chars=2,min=1,max=4,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_unit.disable()
|
||||
|
||||
function tool_ctl.p_assign(opt)
|
||||
|
@ -31,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
|
||||
local sps_rtu = require("rtu.dev.sps_rtu")
|
||||
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
|
||||
|
||||
local RTU_VERSION = "v1.10.1"
|
||||
local RTU_VERSION = "v1.10.2"
|
||||
|
||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
|
||||
|