@ -170,9 +170,43 @@ while true do
|
||||
local event, param1, param2, param3, param4, param5 = os.pullEventRaw()
|
||||
|
||||
if event == "peripheral_detach" then
|
||||
ppm.handle_unmount(param1)
|
||||
-- handle loss of a device
|
||||
local device = ppm.handle_unmount(param1)
|
||||
|
||||
-- todo: handle unit change
|
||||
for i = 1, #units do
|
||||
-- find disconnected device
|
||||
if units[i].device == device then
|
||||
-- we are going to let the PPM prevent crashes
|
||||
-- return fault flags/codes to MODBUS queries
|
||||
local unit = units[i]
|
||||
println_ts("lost the " .. unit.type .. " on interface " .. unit.name)
|
||||
end
|
||||
end
|
||||
elseif event == "peripheral" then
|
||||
-- relink lost peripheral to correct unit entry
|
||||
local type, device = ppm.mount(param1)
|
||||
|
||||
for i = 1, #units do
|
||||
local unit = units[i]
|
||||
|
||||
-- find disconnected device to reconnect
|
||||
if unit.name == param1 then
|
||||
-- found, re-link
|
||||
unit.device = device
|
||||
|
||||
if unit.type == "boiler" then
|
||||
unit.rtu = boiler_rtu(device)
|
||||
elseif unit.type == "turbine" then
|
||||
unit.rtu = turbine_rtu(device)
|
||||
elseif unit.type == "imatrix" then
|
||||
unit.rtu = imatrix_rtu(device)
|
||||
end
|
||||
|
||||
unit.modbus_io = modbus_init(unit.rtu)
|
||||
|
||||
println_ts("reconnected the " .. unit.type .. " on interface " .. unit.name)
|
||||
end
|
||||
end
|
||||
elseif event == "timer" and param1 == loop_tick then
|
||||
-- period tick, if we are linked send heartbeat, if not send advertisement
|
||||
if linked then
|
||||
|