Merge pull request #281 from MikaylaFischler/devel

2023.07.16 Release
This commit is contained in:
Mikayla 2023-07-16 21:25:00 -04:00 committed by GitHub
commit 9bd79dacad
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
77 changed files with 2497 additions and 808 deletions

109
ccmsi.lua
View File

@ -20,7 +20,7 @@ SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
local function println(message) print(tostring(message)) end
local function print(message) term.write(tostring(message)) end
local CCMSI_VERSION = "v1.5a"
local CCMSI_VERSION = "v1.7d"
local install_dir = "/.install-cache"
local manifest_path = "https://mikaylafischler.github.io/cc-mek-scada/manifests/"
@ -44,11 +44,15 @@ local function get_opt(opt, options)
return nil
end
-- wait for any key to be pressed
---@diagnostic disable-next-line: undefined-field
local function any_key() os.pullEvent("key_up") end
-- ask the user yes or no
local function ask_y_n(question, default)
print(question)
if default == true then print(" (Y/n)? ") else print(" (y/N)? ") end
local response = read()
local response = read();any_key()
if response == "" then return default
elseif response == "Y" or response == "y" then return true
elseif response == "N" or response == "n" then return false
@ -93,9 +97,7 @@ local function get_remote_manifest()
end
local ok, manifest = pcall(function () return textutils.unserializeJSON(response.readAll()) end)
if not ok then
red(); println("error parsing remote installation manifest"); white()
end
if not ok then red();println("error parsing remote installation manifest");white() end
return ok, manifest
end
@ -120,6 +122,78 @@ local function write_install_manifest(manifest, dependencies)
imfile.close()
end
-- recursively build a tree out of the file manifest
local function gen_tree(manifest)
local function _tree_add(tree, split)
if #split > 1 then
local name = table.remove(split, 1)
if tree[name] == nil then tree[name] = {} end
table.insert(tree[name], _tree_add(tree[name], split))
else return split[1] end
return nil
end
local list, tree = {}, {}
-- make a list of each and every file
for _, files in pairs(manifest.files) do for i = 1, #files do table.insert(list, files[i]) end end
for i = 1, #list do
local split = {}
string.gsub(list[i], "([^/]+)", function(c) split[#split + 1] = c end)
if #split == 1 then table.insert(tree, list[i])
else table.insert(tree, _tree_add(tree, split)) end
end
return tree
end
local function _in_array(val, array)
for _, v in pairs(array) do if v == val then return true end end
return false
end
local function _clean_dir(dir, tree)
if tree == nil then tree = {} end
local ls = fs.list(dir)
for _, val in pairs(ls) do
local path = dir .. "/" .. val
if fs.isDir(path) then
_clean_dir(path, tree[val])
if #fs.list(path) == 0 then fs.delete(path);println("deleted " .. path) end
elseif not _in_array(val, tree) then
fs.delete(path)
println("deleted " .. path)
end
end
end
-- go through app/common directories to delete unused files
local function clean(manifest)
local root_ext = false
local tree = gen_tree(manifest)
table.insert(tree, "install_manifest.json")
table.insert(tree, "ccmsi.lua")
table.insert(tree, "log.txt")
lgray()
local ls = fs.list("/")
for _, val in pairs(ls) do
if fs.isDir(val) then
if tree[val] ~= nil then _clean_dir("/" .. val, tree[val]) end
if #fs.list(val) == 0 then fs.delete(val);println("deleted " .. val) end
elseif not _in_array(val, tree) then
root_ext = true
yellow();println(val .. " not used")
end
end
white()
if root_ext then println("Files in root directory won't be automatically deleted.") end
end
-- get and validate command line options
println("-- CC Mekanism SCADA Installer " .. CCMSI_VERSION .. " --")
@ -277,7 +351,7 @@ elseif mode == "install" or mode == "update" then
ver.lockbox.changed = ver.lockbox.v_local ~= ver.lockbox.v_remote
-- ask for confirmation
if not ask_y_n("Continue?", false) then return end
if not ask_y_n("Continue", false) then return end
--------------------------
-- START INSTALL/UPDATE --
@ -384,6 +458,9 @@ elseif mode == "install" or mode == "update" then
if mode == "install" then
println("Installation completed successfully.")
else println("Update completed successfully.") end
white();println("Ready to clean up unused files, press any key to continue...")
any_key();clean(manifest)
white();println("Done.")
else
if mode == "install" then
red();println("Installation failed.")
@ -424,6 +501,9 @@ elseif mode == "install" or mode == "update" then
if mode == "install" then
println("Installation completed successfully.")
else println("Update completed successfully.") end
white();println("Ready to clean up unused files, press any key to continue...")
any_key();clean(manifest)
white();println("Done.")
else
red()
if mode == "install" then
@ -449,7 +529,10 @@ elseif mode == "remove" or mode == "purge" then
end
-- ask for confirmation
if not ask_y_n("Continue?", false) then return end
if not ask_y_n("Continue", false) then return end
-- delete unused files first
clean(manifest)
local file_list = manifest.files
local dependencies = manifest.depends[app]
@ -470,8 +553,8 @@ elseif mode == "remove" or mode == "purge" then
if not log_deleted then
red();println("failed to delete log file")
white(); println("press enter to continue...")
read(); lgray()
white();println("press any key to continue...")
any_key();lgray()
end
end
@ -480,10 +563,7 @@ elseif mode == "remove" or mode == "purge" then
local files = file_list[dependency]
for _, file in pairs(files) do
if mode == "purge" or file ~= config_file then
if fs.exists(file) then
fs.delete(file)
println("deleted " .. file)
end
if fs.exists(file) then fs.delete(file);println("deleted " .. file) end
end
end
@ -508,8 +588,7 @@ elseif mode == "remove" or mode == "purge" then
end
if folder ~= app and fs.isDir(folder) then
fs.delete(folder)
println("deleted app subdirectory " .. folder)
fs.delete(folder);println("deleted app subdirectory " .. folder)
end
end
end

View File

@ -2,6 +2,7 @@ local comms = require("scada-common.comms")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local util = require("scada-common.util")
local types = require("scada-common.types")
local iocontrol = require("coordinator.iocontrol")
local process = require("coordinator.process")
@ -12,7 +13,6 @@ local dialog = require("coordinator.ui.dialog")
local print = util.print
local println = util.println
local println_ts = util.println_ts
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
@ -22,6 +22,8 @@ local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
local UNIT_COMMAND = comms.UNIT_COMMAND
local FAC_COMMAND = comms.FAC_COMMAND
local LINK_TIMEOUT = 60.0
local coordinator = {}
-- request the user to select a monitor
@ -227,9 +229,12 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
sv_seq_num = 0,
sv_r_seq_num = nil,
sv_config_err = false,
connected = false,
last_est_ack = ESTABLISH_ACK.ALLOW,
last_api_est_acks = {}
last_api_est_acks = {},
est_start = 0,
est_last = 0,
est_tick_waiting = nil,
est_task_done = nil
}
comms.set_trusted_range(range)
@ -295,55 +300,30 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
---@class coord_comms
local public = {}
-- close the connection to the server
function public.close()
sv_watchdog.cancel()
self.sv_addr = comms.BROADCAST
self.sv_linked = false
self.sv_r_seq_num = nil
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.CLOSE, {})
end
-- try to connect to the supervisor if not already linked
---@param abort boolean? true to print out cancel info if not linked (use on program terminate)
---@return boolean ok, boolean start_ui
function public.try_connect(abort)
local ok = true
local start_ui = false
-- attempt to connect to the subervisor
---@nodiscard
---@param timeout_s number timeout in seconds
---@param tick_dmesg_waiting function callback to tick dmesg waiting
---@param task_done function callback to show done on dmesg
---@return boolean sv_linked true if connected, false otherwise
--- EVENT_CONSUMER: this function consumes events
function public.sv_connect(timeout_s, tick_dmesg_waiting, task_done)
local clock = util.new_clock(1)
local start = util.time_s()
local terminated = false
if not self.sv_linked then
if self.est_tick_waiting == nil then
self.est_start = util.time_s()
self.est_last = self.est_start
self.est_tick_waiting, self.est_task_done =
coordinator.log_comms_connecting("attempting to connect to configured supervisor on channel " .. svr_channel)
_send_establish()
clock.start()
while (util.time_s() - start) < timeout_s and (not self.sv_linked) and (not self.sv_config_err) do
local event, p1, p2, p3, p4, p5 = util.pull_event()
if event == "timer" and clock.is_clock(p1) then
-- timed out attempt, try again
tick_dmesg_waiting(math.max(0, timeout_s - (util.time_s() - start)))
_send_establish()
clock.start()
elseif event == "timer" then
-- keep checking watchdog timers
apisessions.check_all_watchdogs(p1)
elseif event == "modem_message" then
-- handle message
local packet = public.parse_packet(p1, p2, p3, p4, p5)
public.handle_packet(packet)
elseif event == "terminate" then
terminated = true
break
end
else
self.est_tick_waiting(math.max(0, LINK_TIMEOUT - (util.time_s() - self.est_start)))
end
task_done(self.sv_linked)
if abort or (util.time_s() - self.est_start) >= LINK_TIMEOUT then
self.est_task_done(false)
if terminated then
if abort then
coordinator.log_comms("supervisor connection attempt cancelled by user")
elseif self.sv_config_err then
coordinator.log_comms("supervisor cooling configuration invalid, check supervisor config file")
@ -359,13 +339,39 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
end
end
return self.sv_linked
ok = false
elseif self.sv_config_err then
coordinator.log_comms("supervisor cooling configuration invalid, check supervisor config file")
ok = false
elseif (util.time_s() - self.est_last) > 1.0 then
_send_establish()
self.est_last = util.time_s()
end
elseif self.est_tick_waiting ~= nil then
self.est_task_done(true)
self.est_tick_waiting = nil
self.est_task_done = nil
start_ui = true
end
return ok, start_ui
end
-- close the connection to the server
function public.close()
sv_watchdog.cancel()
self.sv_addr = comms.BROADCAST
self.sv_linked = false
self.sv_r_seq_num = nil
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.CLOSE, {})
end
-- send a facility command
---@param cmd FAC_COMMAND command
function public.send_fac_command(cmd)
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, { cmd })
---@param option any? optional option options for the optional options (like waste mode)
function public.send_fac_command(cmd, option)
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, { cmd, option })
end
-- send the auto process control configuration with a start command
@ -379,7 +385,7 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
-- send a unit command
---@param cmd UNIT_COMMAND command
---@param unit integer unit ID
---@param option any? optional option options for the optional options (like burn rate) (does option still look like a word?)
---@param option any? optional option options for the optional options (like burn rate)
function public.send_unit_command(cmd, unit, option)
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.UNIT_CMD, { cmd, unit, option })
end
@ -424,7 +430,10 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
-- handle a packet
---@param packet mgmt_frame|crdn_frame|capi_frame|nil
---@return boolean close_ui
function public.handle_packet(packet)
local was_linked = self.sv_linked
if packet ~= nil then
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
@ -434,7 +443,9 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
if l_chan ~= crd_channel then
log.debug("received packet on unconfigured channel " .. l_chan, true)
elseif r_chan == pkt_channel then
if protocol == PROTOCOL.COORD_API then
if not self.sv_linked then
log.debug("discarding pocket API packet before linked to supervisor")
elseif protocol == PROTOCOL.COORD_API then
---@cast packet capi_frame
-- look for an associated session
local session = apisessions.find_session(src_addr)
@ -473,7 +484,6 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
elseif dev_type == DEVICE_TYPE.PKT then
-- pocket linking request
local id = apisessions.establish_session(src_addr, firmware_v)
println(util.c("[API] pocket (", firmware_v, ") [@", src_addr, "] \xbb connected"))
coordinator.log_comms(util.c("API_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", id))
_send_api_establish_ack(packet.scada_frame, ESTABLISH_ACK.ALLOW)
@ -496,12 +506,12 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
-- check sequence number
if self.sv_r_seq_num == nil then
self.sv_r_seq_num = packet.scada_frame.seq_num()
elseif self.connected and ((self.sv_r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
elseif self.sv_linked and ((self.sv_r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.sv_r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
return false
elseif self.sv_linked and src_addr ~= self.sv_addr then
log.debug("received packet from unknown computer " .. src_addr .. " while linked; channel in use by another system?")
return
return false
else
self.sv_r_seq_num = packet.scada_frame.seq_num()
end
@ -563,6 +573,10 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
end
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
iocontrol.get_db().facility.ack_alarms_ack(ack)
elseif cmd == FAC_COMMAND.SET_WASTE_MODE then
process.waste_ack_handle(packet.data[2])
elseif cmd == FAC_COMMAND.SET_PU_FB then
process.pu_fb_ack_handle(packet.data[2])
else
log.debug(util.c("received facility command ack with unknown command ", cmd))
end
@ -627,70 +641,7 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 2 then
local est_ack = packet.data[1]
local config = packet.data[2]
if est_ack == ESTABLISH_ACK.ALLOW then
if type(config) == "table" and #config > 1 then
-- get configuration
---@class facility_conf
local conf = {
num_units = config[1], ---@type integer
defs = {} -- boilers and turbines
}
if (#config - 1) == (conf.num_units * 2) then
-- record sequence of pairs of [#boilers, #turbines] per unit
for i = 2, #config do
table.insert(conf.defs, config[i])
end
-- init io controller
iocontrol.init(conf, public)
self.sv_addr = src_addr
self.sv_linked = true
self.sv_config_err = false
else
self.sv_config_err = true
log.warning("invalid supervisor configuration definitions received, establish failed")
end
else
log.debug("invalid supervisor configuration table received, establish failed")
end
else
log.debug("SCADA_MGMT establish packet reply (len = 2) unsupported")
end
self.last_est_ack = est_ack
elseif packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.DENY then
if self.last_est_ack ~= est_ack then
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.last_est_ack ~= est_ack then
log.warning("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.last_est_ack ~= est_ack then
log.warning("supervisor comms version mismatch")
end
else
log.debug("SCADA_MGMT establish packet reply (len = 1) unsupported")
end
self.last_est_ack = est_ack
else
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif self.sv_linked then
if self.sv_linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
@ -715,11 +666,83 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
self.sv_addr = comms.BROADCAST
self.sv_linked = false
self.sv_r_seq_num = nil
println_ts("server connection closed by remote host")
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
log.info("server connection closed by remote host")
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type)
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 2 then
local est_ack = packet.data[1]
local config = packet.data[2]
if est_ack == ESTABLISH_ACK.ALLOW then
-- reset to disconnected before validating
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
if type(config) == "table" and #config > 1 then
-- get configuration
---@class facility_conf
local conf = {
num_units = config[1], ---@type integer
defs = {} -- boilers and turbines
}
if (#config - 1) == (conf.num_units * 2) then
-- record sequence of pairs of [#boilers, #turbines] per unit
for i = 2, #config do
table.insert(conf.defs, config[i])
end
-- init io controller
iocontrol.init(conf, public)
self.sv_addr = src_addr
self.sv_linked = true
self.sv_r_seq_num = nil
self.sv_config_err = false
iocontrol.fp_link_state(types.PANEL_LINK_STATE.LINKED)
else
self.sv_config_err = true
log.warning("invalid supervisor configuration definitions received, establish failed")
end
else
log.debug("invalid supervisor configuration table received, establish failed")
end
else
log.debug("SCADA_MGMT establish packet reply (len = 2) unsupported")
end
self.last_est_ack = est_ack
elseif packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.DENY then
if self.last_est_ack ~= est_ack then
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DENIED)
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.last_est_ack ~= est_ack then
iocontrol.fp_link_state(types.PANEL_LINK_STATE.COLLISION)
log.warning("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.last_est_ack ~= est_ack then
iocontrol.fp_link_state(types.PANEL_LINK_STATE.BAD_VERSION)
log.warning("supervisor comms version mismatch")
end
else
log.debug("SCADA_MGMT establish packet reply (len = 1) unsupported")
end
self.last_est_ack = est_ack
else
log.debug("SCADA_MGMT establish packet length mismatch")
end
else
log.debug("discarding non-link SCADA_MGMT packet before linked")
end
@ -730,6 +753,8 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
log.debug("received packet for unknown channel " .. r_chan, true)
end
end
return was_linked and not self.sv_linked
end
-- check if the coordinator is still linked to the supervisor

View File

@ -10,9 +10,15 @@ local util = require("scada-common.util")
local process = require("coordinator.process")
local sounder = require("coordinator.sounder")
local pgi = require("coordinator.ui.pgi")
local ALARM_STATE = types.ALARM_STATE
local PROCESS = types.PROCESS
-- nominal RTT is ping (0ms to 10ms usually) + 500ms for CRD main loop tick
local WARN_RTT = 1000 -- 2x as long as expected w/ 0 ping
local HIGH_RTT = 1500 -- 3.33x as long as expected w/ 0 ping
local iocontrol = {}
---@class ioctl
@ -27,6 +33,19 @@ local function __generic_ack(success) end
-- luacheck: unused args
-- initialize front panel PSIL
---@param firmware_v string coordinator version
---@param comms_v string comms version
function iocontrol.init_fp(firmware_v, comms_v)
---@class ioctl_front_panel
io.fp = {
ps = psil.create()
}
io.fp.ps.publish("version", firmware_v)
io.fp.ps.publish("comms_version", comms_v)
end
-- initialize the coordinator IO controller
---@param conf facility_conf configuration
---@param comms coord_comms comms reference
@ -52,6 +71,10 @@ function iocontrol.init(conf, comms)
gen_fault = false
},
---@type WASTE_PRODUCT
auto_current_waste_product = types.WASTE_PRODUCT.PLUTONIUM,
auto_pu_fallback_active = false,
radiation = types.new_zero_radiation_reading(),
save_cfg_ack = __generic_ack,
@ -65,16 +88,21 @@ function iocontrol.init(conf, comms)
induction_ps_tbl = {},
induction_data_tbl = {},
sps_ps_tbl = {},
sps_data_tbl = {},
tank_ps_tbl = {},
tank_data_tbl = {},
env_d_ps = psil.create(),
env_d_data = {}
}
-- create induction tables (currently only 1 is supported)
for _ = 1, conf.num_units do
local data = {} ---@type imatrix_session_db
-- create induction and SPS tables (currently only 1 of each is supported)
table.insert(io.facility.induction_ps_tbl, psil.create())
table.insert(io.facility.induction_data_tbl, data)
end
table.insert(io.facility.induction_data_tbl, {})
table.insert(io.facility.sps_ps_tbl, psil.create())
table.insert(io.facility.sps_data_tbl, {})
io.units = {}
for i = 1, conf.num_units do
@ -87,11 +115,15 @@ function iocontrol.init(conf, comms)
num_boilers = 0,
num_turbines = 0,
num_snas = 0,
control_state = false,
burn_rate_cmd = 0.0,
waste_control = 0,
radiation = types.new_zero_radiation_reading(),
sna_prod_rate = 0.0,
waste_mode = types.WASTE_MODE.MANUAL_PLUTONIUM,
waste_product = types.WASTE_PRODUCT.PLUTONIUM,
-- auto control group
a_group = 0,
@ -101,9 +133,9 @@ function iocontrol.init(conf, comms)
reset_rps = function () process.reset_rps(i) end,
ack_alarms = function () process.ack_all_alarms(i) end,
set_burn = function (rate) process.set_rate(i, rate) end, ---@param rate number burn rate
set_waste = function (mode) process.set_waste(i, mode) end, ---@param mode integer waste processing mode
set_waste = function (mode) process.set_unit_waste(i, mode) end, ---@param mode WASTE_MODE waste processing mode
set_group = function (grp) process.set_group(i, grp) end, ---@param grp integer|0 group ID or 0
set_group = function (grp) process.set_group(i, grp) end, ---@param grp integer|0 group ID or 0 for manual
start_ack = __generic_ack,
scram_ack = __generic_ack,
@ -152,7 +184,10 @@ function iocontrol.init(conf, comms)
boiler_data_tbl = {},
turbine_ps_tbl = {},
turbine_data_tbl = {}
turbine_data_tbl = {},
tank_ps_tbl = {},
tank_data_tbl = {}
}
-- create boiler tables
@ -179,6 +214,92 @@ function iocontrol.init(conf, comms)
process.init(io, comms)
end
--#region Front Panel PSIL
-- toggle heartbeat indicator
function iocontrol.heartbeat() io.fp.ps.toggle("heartbeat") end
-- report presence of the wireless modem
---@param has_modem boolean
function iocontrol.fp_has_modem(has_modem) io.fp.ps.publish("has_modem", has_modem) end
-- report presence of the speaker
---@param has_speaker boolean
function iocontrol.fp_has_speaker(has_speaker) io.fp.ps.publish("has_speaker", has_speaker) end
-- report supervisor link state
---@param state integer
function iocontrol.fp_link_state(state) io.fp.ps.publish("link_state", state) end
-- report monitor connection state
---@param id integer unit ID or 0 for main
function iocontrol.fp_monitor_state(id, connected)
local name = "main_monitor"
if id > 0 then name = "unit_monitor_" .. id end
io.fp.ps.publish(name, connected)
end
-- report PKT firmware version and PKT session connection state
---@param session_id integer PKT session
---@param fw string firmware version
---@param s_addr integer PKT computer ID
function iocontrol.fp_pkt_connected(session_id, fw, s_addr)
io.fp.ps.publish("pkt_" .. session_id .. "_fw", fw)
io.fp.ps.publish("pkt_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr))
pgi.create_pkt_entry(session_id)
end
-- report PKT session disconnected
---@param session_id integer PKT session
function iocontrol.fp_pkt_disconnected(session_id)
pgi.delete_pkt_entry(session_id)
end
-- transmit PKT session RTT
---@param session_id integer PKT session
---@param rtt integer round trip time
function iocontrol.fp_pkt_rtt(session_id, rtt)
io.fp.ps.publish("pkt_" .. session_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.yellow_hc)
else
io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.green)
end
end
--#endregion
--#region Builds
-- record and publish multiblock RTU build data
---@param id integer
---@param entry table
---@param data_tbl table
---@param ps_tbl table
---@param create boolean? true to create an entry if non exists, false to fail on missing
---@return boolean ok true if data saved, false if invalid ID
local function _record_multiblock_build(id, entry, data_tbl, ps_tbl, create)
local exists = type(data_tbl[id]) == "table"
if exists or create then
if not exists then
ps_tbl[id] = psil.create()
data_tbl[id] = {}
end
data_tbl[id].formed = entry[1] ---@type boolean
data_tbl[id].build = entry[2] ---@type table
ps_tbl[id].publish("formed", entry[1])
for key, val in pairs(data_tbl[id].build) do ps_tbl[id].publish(key, val) end
end
return exists or (create == true)
end
-- populate facility structure builds
---@param build table
---@return boolean valid
@ -191,21 +312,29 @@ function iocontrol.record_facility_builds(build)
-- induction matricies
if type(build.induction) == "table" then
for id, matrix in pairs(build.induction) do
if type(fac.induction_data_tbl[id]) == "table" then
fac.induction_data_tbl[id].formed = matrix[1] ---@type boolean
fac.induction_data_tbl[id].build = matrix[2] ---@type table
fac.induction_ps_tbl[id].publish("formed", matrix[1])
for key, val in pairs(fac.induction_data_tbl[id].build) do
fac.induction_ps_tbl[id].publish(key, val)
end
else
if not _record_multiblock_build(id, matrix, fac.induction_data_tbl, fac.induction_ps_tbl) then
log.debug(util.c("iocontrol.record_facility_builds: invalid induction matrix id ", id))
valid = false
end
end
end
-- SPS
if type(build.sps) == "table" then
for id, sps in pairs(build.sps) do
if not _record_multiblock_build(id, sps, fac.sps_data_tbl, fac.sps_ps_tbl) then
log.debug(util.c("iocontrol.record_facility_builds: invalid SPS id ", id))
valid = false
end
end
end
-- dynamic tanks
if type(build.tanks) == "table" then
for id, tank in pairs(build.tanks) do
_record_multiblock_build(id, tank, fac.tank_data_tbl, fac.tank_ps_tbl, true)
end
end
else
log.debug("facility builds not a table")
valid = false
@ -249,16 +378,7 @@ function iocontrol.record_unit_builds(builds)
-- boiler builds
if type(build.boilers) == "table" then
for b_id, boiler in pairs(build.boilers) do
if type(unit.boiler_data_tbl[b_id]) == "table" then
unit.boiler_data_tbl[b_id].formed = boiler[1] ---@type boolean
unit.boiler_data_tbl[b_id].build = boiler[2] ---@type table
unit.boiler_ps_tbl[b_id].publish("formed", boiler[1])
for key, val in pairs(unit.boiler_data_tbl[b_id].build) do
unit.boiler_ps_tbl[b_id].publish(key, val)
end
else
if not _record_multiblock_build(b_id, boiler, unit.boiler_data_tbl, unit.boiler_ps_tbl) then
log.debug(util.c(log_header, "invalid boiler id ", b_id))
valid = false
end
@ -268,27 +388,49 @@ function iocontrol.record_unit_builds(builds)
-- turbine builds
if type(build.turbines) == "table" then
for t_id, turbine in pairs(build.turbines) do
if type(unit.turbine_data_tbl[t_id]) == "table" then
unit.turbine_data_tbl[t_id].formed = turbine[1] ---@type boolean
unit.turbine_data_tbl[t_id].build = turbine[2] ---@type table
unit.turbine_ps_tbl[t_id].publish("formed", turbine[1])
for key, val in pairs(unit.turbine_data_tbl[t_id].build) do
unit.turbine_ps_tbl[t_id].publish(key, val)
end
else
if not _record_multiblock_build(t_id, turbine, unit.turbine_data_tbl, unit.turbine_ps_tbl) then
log.debug(util.c(log_header, "invalid turbine id ", t_id))
valid = false
end
end
end
-- dynamic tank builds
if type(build.tanks) == "table" then
for d_id, d_tank in pairs(build.tanks) do
_record_multiblock_build(d_id, d_tank, unit.tank_data_tbl, unit.tank_ps_tbl, true)
end
end
end
end
return valid
end
--#endregion
--#region Statuses
-- record and publish multiblock status data
---@param entry any
---@param data imatrix_session_db|sps_session_db|dynamicv_session_db|turbinev_session_db|boilerv_session_db
---@param ps psil
---@return boolean is_faulted
local function _record_multiblock_status(entry, data, ps)
local is_faulted = entry[1] ---@type boolean
data.formed = entry[2] ---@type boolean
data.state = entry[3] ---@type table
data.tanks = entry[4] ---@type table
ps.publish("formed", data.formed)
ps.publish("faulted", is_faulted)
for key, val in pairs(data.state) do ps.publish(key, val) end
for key, val in pairs(data.tanks) do ps.publish(key, val) end
return is_faulted
end
-- update facility status
---@param status table
---@return boolean valid
@ -306,7 +448,7 @@ function iocontrol.update_facility_status(status)
local ctl_status = status[1]
if type(ctl_status) == "table" and #ctl_status == 14 then
if type(ctl_status) == "table" and #ctl_status == 16 then
fac.all_sys_ok = ctl_status[1]
fac.auto_ready = ctl_status[2]
@ -354,6 +496,12 @@ function iocontrol.update_facility_status(status)
io.units[i].unit_ps.publish("auto_group", names[group_map[i] + 1])
end
end
fac.auto_current_waste_product = ctl_status[15]
fac.auto_pu_fallback_active = ctl_status[16]
fac.ps.publish("current_waste_product", fac.auto_current_waste_product)
fac.ps.publish("pu_fallback_active", fac.auto_pu_fallback_active)
else
log.debug(log_header .. "control status not a table or length mismatch")
valid = false
@ -390,36 +538,23 @@ function iocontrol.update_facility_status(status)
for id, matrix in pairs(rtu_statuses.induction) do
if type(fac.induction_data_tbl[id]) == "table" then
local rtu_faulted = matrix[1] ---@type boolean
fac.induction_data_tbl[id].formed = matrix[2] ---@type boolean
fac.induction_data_tbl[id].state = matrix[3] ---@type table
fac.induction_data_tbl[id].tanks = matrix[4] ---@type table
local data = fac.induction_data_tbl[id] ---@type imatrix_session_db
local ps = fac.induction_ps_tbl[id] ---@type psil
fac.induction_ps_tbl[id].publish("formed", data.formed)
fac.induction_ps_tbl[id].publish("faulted", rtu_faulted)
local rtu_faulted = _record_multiblock_status(matrix, data, ps)
if data.formed then
if rtu_faulted then
fac.induction_ps_tbl[id].publish("computed_status", 3) -- faulted
elseif data.tanks.energy_fill >= 0.99 then
fac.induction_ps_tbl[id].publish("computed_status", 6) -- full
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.tanks.energy_fill >= 0.99 then
ps.publish("computed_status", 6) -- full
elseif data.tanks.energy_fill <= 0.01 then
fac.induction_ps_tbl[id].publish("computed_status", 5) -- empty
ps.publish("computed_status", 5) -- empty
else
fac.induction_ps_tbl[id].publish("computed_status", 4) -- on-line
ps.publish("computed_status", 4) -- on-line
end
else
fac.induction_ps_tbl[id].publish("computed_status", 2) -- not formed
end
for key, val in pairs(fac.induction_data_tbl[id].state) do
fac.induction_ps_tbl[id].publish(key, val)
end
for key, val in pairs(fac.induction_data_tbl[id].tanks) do
fac.induction_ps_tbl[id].publish(key, val)
ps.publish("computed_status", 2) -- not formed
end
else
log.debug(util.c(log_header, "invalid induction matrix id ", id))
@ -430,6 +565,82 @@ function iocontrol.update_facility_status(status)
valid = false
end
-- SPS statuses
if type(rtu_statuses.sps) == "table" then
for id = 1, #fac.sps_ps_tbl do
if rtu_statuses.sps[id] == nil then
-- disconnected
fac.sps_ps_tbl[id].publish("computed_status", 1)
end
end
for id, sps in pairs(rtu_statuses.sps) do
if type(fac.sps_data_tbl[id]) == "table" then
local data = fac.sps_data_tbl[id] ---@type sps_session_db
local ps = fac.sps_ps_tbl[id] ---@type psil
local rtu_faulted = _record_multiblock_status(sps, data, ps)
if rtu_faulted then
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.state.process_rate > 0 then
ps.publish("computed_status", 5) -- active
else
ps.publish("computed_status", 4) -- idle
end
else
ps.publish("computed_status", 2) -- not formed
end
io.facility.ps.publish("am_rate", data.state.process_rate * 1000)
else
log.debug(util.c(log_header, "invalid sps id ", id))
end
end
else
log.debug(log_header .. "sps list not a table")
valid = false
end
-- dynamic tank statuses
if type(rtu_statuses.tanks) == "table" then
for id = 1, #fac.tank_ps_tbl do
if rtu_statuses.tanks[id] == nil then
-- disconnected
fac.tank_ps_tbl[id].publish("computed_status", 1)
end
end
for id, tank in pairs(rtu_statuses.tanks) do
if type(fac.tank_data_tbl[id]) == "table" then
local data = fac.tank_data_tbl[id] ---@type dynamicv_session_db
local ps = fac.tank_ps_tbl[id] ---@type psil
local rtu_faulted = _record_multiblock_status(tank, data, ps)
if rtu_faulted then
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.tanks.fill >= 0.99 then
ps.publish("computed_status", 6) -- full
elseif data.tanks.fill < 0.20 then
ps.publish("computed_status", 5) -- low
else
ps.publish("computed_status", 4) -- on-line
end
else
ps.publish("computed_status", 2) -- not formed
end
else
log.debug(util.c(log_header, "invalid dynamic tank id ", id))
end
end
else
log.debug(log_header .. "dyanmic tank list not a table")
valid = false
end
-- environment detector status
if type(rtu_statuses.rad_mon) == "table" then
if #rtu_statuses.rad_mon > 0 then
@ -472,6 +683,9 @@ function iocontrol.update_unit_statuses(statuses)
valid = false
else
local burn_rate_sum = 0.0
local sna_count_sum = 0
local pu_rate = 0.0
local po_rate = 0.0
-- get all unit statuses
for i = 1, #statuses do
@ -480,6 +694,8 @@ function iocontrol.update_unit_statuses(statuses)
local unit = io.units[i] ---@type ioctl_unit
local status = statuses[i]
local burn_rate = 0.0
if type(status) ~= "table" or #status ~= 5 then
log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)")
valid = false
@ -515,7 +731,8 @@ function iocontrol.update_unit_statuses(statuses)
-- if status hasn't been received, mek_status = {}
if type(unit.reactor_data.mek_status.act_burn_rate) == "number" then
burn_rate_sum = burn_rate_sum + unit.reactor_data.mek_status.act_burn_rate
burn_rate = unit.reactor_data.mek_status.act_burn_rate
burn_rate_sum = burn_rate_sum + burn_rate
end
if unit.reactor_data.mek_status.status then
@ -571,34 +788,21 @@ function iocontrol.update_unit_statuses(statuses)
for id, boiler in pairs(rtu_statuses.boilers) do
if type(unit.boiler_data_tbl[id]) == "table" then
local rtu_faulted = boiler[1] ---@type boolean
unit.boiler_data_tbl[id].formed = boiler[2] ---@type boolean
unit.boiler_data_tbl[id].state = boiler[3] ---@type table
unit.boiler_data_tbl[id].tanks = boiler[4] ---@type table
local data = unit.boiler_data_tbl[id] ---@type boilerv_session_db
local ps = unit.boiler_ps_tbl[id] ---@type psil
unit.boiler_ps_tbl[id].publish("formed", data.formed)
unit.boiler_ps_tbl[id].publish("faulted", rtu_faulted)
local rtu_faulted = _record_multiblock_status(boiler, data, ps)
if rtu_faulted then
unit.boiler_ps_tbl[id].publish("computed_status", 3) -- faulted
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.state.boil_rate > 0 then
unit.boiler_ps_tbl[id].publish("computed_status", 5) -- active
ps.publish("computed_status", 5) -- active
else
unit.boiler_ps_tbl[id].publish("computed_status", 4) -- idle
ps.publish("computed_status", 4) -- idle
end
else
unit.boiler_ps_tbl[id].publish("computed_status", 2) -- not formed
end
for key, val in pairs(unit.boiler_data_tbl[id].state) do
unit.boiler_ps_tbl[id].publish(key, val)
end
for key, val in pairs(unit.boiler_data_tbl[id].tanks) do
unit.boiler_ps_tbl[id].publish(key, val)
ps.publish("computed_status", 2) -- not formed
end
else
log.debug(util.c(log_header, "invalid boiler id ", id))
@ -621,36 +825,23 @@ function iocontrol.update_unit_statuses(statuses)
for id, turbine in pairs(rtu_statuses.turbines) do
if type(unit.turbine_data_tbl[id]) == "table" then
local rtu_faulted = turbine[1] ---@type boolean
unit.turbine_data_tbl[id].formed = turbine[2] ---@type boolean
unit.turbine_data_tbl[id].state = turbine[3] ---@type table
unit.turbine_data_tbl[id].tanks = turbine[4] ---@type table
local data = unit.turbine_data_tbl[id] ---@type turbinev_session_db
local ps = unit.turbine_ps_tbl[id] ---@type psil
unit.turbine_ps_tbl[id].publish("formed", data.formed)
unit.turbine_ps_tbl[id].publish("faulted", rtu_faulted)
local rtu_faulted = _record_multiblock_status(turbine, data, ps)
if rtu_faulted then
unit.turbine_ps_tbl[id].publish("computed_status", 3) -- faulted
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.tanks.energy_fill >= 0.99 then
unit.turbine_ps_tbl[id].publish("computed_status", 6) -- trip
ps.publish("computed_status", 6) -- trip
elseif data.state.flow_rate < 100 then
unit.turbine_ps_tbl[id].publish("computed_status", 4) -- idle
ps.publish("computed_status", 4) -- idle
else
unit.turbine_ps_tbl[id].publish("computed_status", 5) -- active
ps.publish("computed_status", 5) -- active
end
else
unit.turbine_ps_tbl[id].publish("computed_status", 2) -- not formed
end
for key, val in pairs(unit.turbine_data_tbl[id].state) do
unit.turbine_ps_tbl[id].publish(key, val)
end
for key, val in pairs(unit.turbine_data_tbl[id].tanks) do
unit.turbine_ps_tbl[id].publish(key, val)
ps.publish("computed_status", 2) -- not formed
end
else
log.debug(util.c(log_header, "invalid turbine id ", id))
@ -662,6 +853,58 @@ function iocontrol.update_unit_statuses(statuses)
valid = false
end
-- dynamic tank statuses
if type(rtu_statuses.tanks) == "table" then
for id = 1, #unit.tank_ps_tbl do
if rtu_statuses.tanks[i] == nil then
-- disconnected
unit.tank_ps_tbl[id].publish("computed_status", 1)
end
end
for id, tank in pairs(rtu_statuses.tanks) do
if type(unit.tank_data_tbl[id]) == "table" then
local data = unit.tank_data_tbl[id] ---@type dynamicv_session_db
local ps = unit.tank_ps_tbl[id] ---@type psil
local rtu_faulted = _record_multiblock_status(tank, data, ps)
if rtu_faulted then
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
if data.tanks.fill >= 0.99 then
ps.publish("computed_status", 6) -- full
elseif data.tanks.fill < 0.20 then
ps.publish("computed_status", 5) -- low
else
ps.publish("computed_status", 5) -- active
end
else
ps.publish("computed_status", 2) -- not formed
end
else
log.debug(util.c(log_header, "invalid dynamic tank id ", id))
valid = false
end
end
else
log.debug(log_header .. "dynamic tank list not a table")
valid = false
end
-- solar neutron activator status info
if type(rtu_statuses.sna) == "table" then
unit.num_snas = rtu_statuses.sna[1] ---@type integer
unit.sna_prod_rate = rtu_statuses.sna[2] ---@type number
unit.unit_ps.publish("sna_prod_rate", unit.sna_prod_rate)
sna_count_sum = sna_count_sum + unit.num_snas
else
log.debug(log_header .. "sna statistic list not a table")
valid = false
end
-- environment detector status
if type(rtu_statuses.rad_mon) == "table" then
if #rtu_statuses.rad_mon > 0 then
@ -739,12 +982,17 @@ function iocontrol.update_unit_statuses(statuses)
local unit_state = status[5]
if type(unit_state) == "table" then
if #unit_state == 5 then
if #unit_state == 6 then
unit.waste_mode = unit_state[5]
unit.waste_product = unit_state[6]
unit.unit_ps.publish("U_StatusLine1", unit_state[1])
unit.unit_ps.publish("U_StatusLine2", unit_state[2])
unit.unit_ps.publish("U_WasteMode", unit_state[3])
unit.unit_ps.publish("U_AutoReady", unit_state[4])
unit.unit_ps.publish("U_AutoDegraded", unit_state[5])
unit.unit_ps.publish("U_AutoReady", unit_state[3])
unit.unit_ps.publish("U_AutoDegraded", unit_state[4])
unit.unit_ps.publish("U_AutoWaste", unit.waste_mode == types.WASTE_MODE.AUTO)
unit.unit_ps.publish("U_WasteMode", unit.waste_mode)
unit.unit_ps.publish("U_WasteProduct", unit.waste_product)
else
log.debug(log_header .. "unit state length mismatch")
valid = false
@ -753,10 +1001,18 @@ function iocontrol.update_unit_statuses(statuses)
log.debug(log_header .. "unit state not a table")
valid = false
end
-- determine waste production for this unit, add to statistics
local is_pu = unit.waste_product == types.WASTE_PRODUCT.PLUTONIUM
pu_rate = pu_rate + util.trinary(is_pu, burn_rate / 10.0, 0.0)
po_rate = po_rate + util.trinary(not is_pu, math.min(burn_rate / 10.0, unit.sna_prod_rate), 0.0)
end
end
io.facility.ps.publish("burn_sum", burn_rate_sum)
io.facility.ps.publish("sna_count", sna_count_sum)
io.facility.ps.publish("pu_rate", pu_rate)
io.facility.ps.publish("po_rate", po_rate)
-- update alarm sounder
sounder.eval(io.units)
@ -765,6 +1021,8 @@ function iocontrol.update_unit_statuses(statuses)
return valid
end
--#endregion
-- get the IO controller database
function iocontrol.get_db() return io end

View File

@ -11,6 +11,7 @@ local FAC_COMMAND = comms.FAC_COMMAND
local UNIT_COMMAND = comms.UNIT_COMMAND
local PROCESS = types.PROCESS
local PRODUCT = types.WASTE_PRODUCT
---@class process_controller
local process = {}
@ -24,7 +25,9 @@ local self = {
burn_target = 0.0,
charge_target = 0.0,
gen_target = 0.0,
limits = {}
limits = {},
waste_product = PRODUCT.PLUTONIUM,
pu_fallback = false
}
}
@ -48,19 +51,23 @@ function process.init(iocontrol, coord_comms)
log.error("process.init(): failed to load coordinator settings file")
end
-- facility auto control configuration
local config = settings.get("PROCESS") ---@type coord_auto_config|nil
if type(config) == "table" then
self.config.mode = config.mode
self.config.burn_target = config.burn_target
self.config.charge_target = config.charge_target
self.config.gen_target = config.gen_target
self.config.limits = config.limits
self.config.waste_product = config.waste_product
self.config.pu_fallback = config.pu_fallback
self.io.facility.ps.publish("process_mode", self.config.mode)
self.io.facility.ps.publish("process_burn_target", self.config.burn_target)
self.io.facility.ps.publish("process_charge_target", self.config.charge_target)
self.io.facility.ps.publish("process_gen_target", self.config.gen_target)
self.io.facility.ps.publish("process_waste_product", self.config.waste_product)
self.io.facility.ps.publish("process_pu_fallback", self.config.pu_fallback)
for id = 1, math.min(#self.config.limits, self.io.facility.num_units) do
local unit = self.io.units[id] ---@type ioctl_unit
@ -70,18 +77,18 @@ function process.init(iocontrol, coord_comms)
log.info("PROCESS: loaded auto control settings from coord.settings")
end
local waste_mode = settings.get("WASTE_MODES") ---@type table|nil
if type(waste_mode) == "table" then
for id, mode in pairs(waste_mode) do
-- unit waste states
local waste_modes = settings.get("WASTE_MODES") ---@type table|nil
if type(waste_modes) == "table" then
for id, mode in pairs(waste_modes) do
self.comms.send_unit_command(UNIT_COMMAND.SET_WASTE, id, mode)
end
log.info("PROCESS: loaded waste mode settings from coord.settings")
log.info("PROCESS: loaded unit waste mode settings from coord.settings")
end
-- unit priority groups
local prio_groups = settings.get("PRIORITY_GROUPS") ---@type table|nil
if type(prio_groups) == "table" then
for id, group in pairs(prio_groups) do
self.comms.send_unit_command(UNIT_COMMAND.SET_GROUP, id, group)
@ -137,7 +144,7 @@ end
-- set waste mode
---@param id integer unit ID
---@param mode integer waste mode
function process.set_waste(id, mode)
function process.set_unit_waste(id, mode)
-- publish so that if it fails then it gets reset
self.io.units[id].unit_ps.publish("U_WasteMode", mode)
@ -153,7 +160,7 @@ function process.set_waste(id, mode)
settings.set("WASTE_MODES", waste_mode)
if not settings.save("/coord.settings") then
log.error("process.set_waste(): failed to save coordinator settings file")
log.error("process.set_unit_waste(): failed to save coordinator settings file")
end
end
@ -204,6 +211,24 @@ end
-- AUTO PROCESS CONTROL --
--------------------------
-- write auto process control to config file
local function _write_auto_config()
-- attempt to load settings
if not settings.load("/coord.settings") then
log.warning("process._write_auto_config(): failed to load coordinator settings file")
end
-- save config
settings.set("PROCESS", self.config)
local saved = settings.save("/coord.settings")
if not saved then
log.warning("process._write_auto_config(): failed to save coordinator settings file")
end
return not not saved
end
-- stop automatic process control
function process.stop_auto()
self.comms.send_fac_command(FAC_COMMAND.STOP)
@ -216,6 +241,30 @@ function process.start_auto()
log.debug("PROCESS: START AUTO CTL")
end
-- set automatic process control waste mode
---@param product WASTE_PRODUCT waste product for auto control
function process.set_process_waste(product)
self.comms.send_fac_command(FAC_COMMAND.SET_WASTE_MODE, product)
log.debug(util.c("PROCESS: SET WASTE ", product))
-- update config table and save
self.config.waste_product = product
_write_auto_config()
end
-- set automatic process control plutonium fallback
---@param enabled boolean whether to enable plutonium fallback
function process.set_pu_fallback(enabled)
self.comms.send_fac_command(FAC_COMMAND.SET_PU_FB, enabled)
log.debug(util.c("PROCESS: SET PU FALLBACK ", enabled))
-- update config table and save
self.config.pu_fallback = enabled
_write_auto_config()
end
-- save process control settings
---@param mode PROCESS control mode
---@param burn_target number burn rate target
@ -223,29 +272,17 @@ end
---@param gen_target number generation rate target
---@param limits table unit burn rate limits
function process.save(mode, burn_target, charge_target, gen_target, limits)
-- attempt to load settings
if not settings.load("/coord.settings") then
log.warning("process.save(): failed to load coordinator settings file")
end
log.debug("PROCESS: SAVE")
-- config table
self.config = {
mode = mode,
burn_target = burn_target,
charge_target = charge_target,
gen_target = gen_target,
limits = limits
}
-- update config table
self.config.mode = mode
self.config.burn_target = burn_target
self.config.charge_target = charge_target
self.config.gen_target = gen_target
self.config.limits = limits
-- save config
settings.set("PROCESS", self.config)
local saved = settings.save("/coord.settings")
if not saved then
log.warning("process.save(): failed to save coordinator settings file")
end
self.io.facility.save_cfg_ack(saved)
self.io.facility.save_cfg_ack(_write_auto_config())
end
-- handle a start command acknowledgement
@ -258,16 +295,33 @@ function process.start_ack_handle(response)
self.config.charge_target = response[4]
self.config.gen_target = response[5]
for i = 1, #response[6] do
for i = 1, math.min(#response[6], self.io.facility.num_units) do
self.config.limits[i] = response[6][i]
local unit = self.io.units[i] ---@type ioctl_unit
unit.unit_ps.publish("burn_limit", self.config.limits[i])
end
self.io.facility.ps.publish("auto_mode", self.config.mode)
self.io.facility.ps.publish("burn_target", self.config.burn_target)
self.io.facility.ps.publish("charge_target", self.config.charge_target)
self.io.facility.ps.publish("gen_target", self.config.gen_target)
self.io.facility.ps.publish("process_mode", self.config.mode)
self.io.facility.ps.publish("process_burn_target", self.config.burn_target)
self.io.facility.ps.publish("process_charge_target", self.config.charge_target)
self.io.facility.ps.publish("process_gen_target", self.config.gen_target)
self.io.facility.start_ack(ack)
end
-- record waste product state after attempting to change it
---@param response WASTE_PRODUCT supervisor waste product state
function process.waste_ack_handle(response)
self.config.waste_product = response
self.io.facility.ps.publish("process_waste_product", response)
end
-- record plutonium fallback state after attempting to change it
---@param response boolean supervisor plutonium fallback state
function process.pu_fb_ack_handle(response)
self.config.pu_fallback = response
self.io.facility.ps.publish("process_pu_fallback", response)
end
return process

View File

@ -5,8 +5,12 @@
local log = require("scada-common.log")
local util = require("scada-common.util")
local style = require("coordinator.ui.style")
local iocontrol = require("coordinator.iocontrol")
local style = require("coordinator.ui.style")
local pgi = require("coordinator.ui.pgi")
local panel_view = require("coordinator.ui.layout.front_panel")
local main_view = require("coordinator.ui.layout.main_view")
local unit_view = require("coordinator.ui.layout.unit_view")
@ -21,7 +25,9 @@ local engine = {
monitors = nil, ---@type monitors_struct|nil
dmesg_window = nil, ---@type table|nil
ui_ready = false,
fp_ready = false,
ui = {
front_panel = nil, ---@type graphics_element|nil
main_display = nil, ---@type graphics_element|nil
unit_displays = {}
}
@ -46,24 +52,10 @@ end
---@param monitors monitors_struct
function renderer.set_displays(monitors)
engine.monitors = monitors
end
-- check if the renderer is configured to use a given monitor peripheral
---@nodiscard
---@param periph table peripheral
---@return boolean is_used
function renderer.is_monitor_used(periph)
if engine.monitors ~= nil then
if engine.monitors.primary == periph then
return true
else
for _, monitor in ipairs(engine.monitors.unit_displays) do
if monitor == periph then return true end
end
end
end
return false
-- report to front panel as connected
iocontrol.fp_monitor_state(0, true)
for i = 1, #engine.monitors.unit_displays do iocontrol.fp_monitor_state(i, true) end
end
-- init all displays in use by the renderer
@ -75,6 +67,17 @@ function renderer.init_displays()
for _, monitor in ipairs(engine.monitors.unit_displays) do
_init_display(monitor)
end
-- init terminal
term.setTextColor(colors.white)
term.setBackgroundColor(colors.black)
term.clear()
term.setCursorPos(1, 1)
-- set overridden colors
for i = 1, #style.fp.colors do
term.setPaletteColor(style.fp.colors[i].c, style.fp.colors[i].hex)
end
end
-- check main display width
@ -109,6 +112,51 @@ function renderer.init_dmesg()
log.direct_dmesg(engine.dmesg_window)
end
-- start the coordinator front panel
function renderer.start_fp()
if not engine.fp_ready then
-- show front panel view on terminal
engine.ui.front_panel = DisplayBox{window=term.native(),fg_bg=style.fp.root}
panel_view(engine.ui.front_panel, #engine.monitors.unit_displays)
-- start flasher callback task
flasher.run()
-- report front panel as ready
engine.fp_ready = true
end
end
-- close out the front panel
function renderer.close_fp()
if engine.fp_ready then
if not engine.ui_ready then
-- stop blinking indicators
flasher.clear()
end
-- disable PGI
pgi.unlink()
-- hide to stop animation callbacks and clear root UI elements
engine.ui.front_panel.hide()
engine.ui.front_panel = nil
engine.fp_ready = false
-- restore colors
for i = 1, #style.colors do
local r, g, b = term.nativePaletteColor(style.colors[i].c)
term.setPaletteColor(style.colors[i].c, r, g, b)
end
-- reset terminal
term.setTextColor(colors.white)
term.setBackgroundColor(colors.black)
term.clear()
term.setCursorPos(1, 1)
end
end
-- start the coordinator GUI
function renderer.start_ui()
if not engine.ui_ready then
@ -116,13 +164,15 @@ function renderer.start_ui()
engine.dmesg_window.setVisible(false)
-- show main view on main monitor
if engine.monitors.primary ~= nil then
engine.ui.main_display = DisplayBox{window=engine.monitors.primary,fg_bg=style.root}
main_view(engine.ui.main_display)
end
-- show unit views on unit displays
for i = 1, #engine.monitors.unit_displays do
engine.ui.unit_displays[i] = DisplayBox{window=engine.monitors.unit_displays[i],fg_bg=style.root}
unit_view(engine.ui.unit_displays[i], i)
for idx, display in pairs(engine.monitors.unit_displays) do
engine.ui.unit_displays[idx] = DisplayBox{window=display,fg_bg=style.root}
unit_view(engine.ui.unit_displays[idx], idx)
end
-- start flasher callback task
@ -135,12 +185,14 @@ end
-- close out the UI
function renderer.close_ui()
if not engine.fp_ready then
-- stop blinking indicators
flasher.clear()
end
-- delete element trees
if engine.ui.main_display ~= nil then engine.ui.main_display.delete() end
for _, display in ipairs(engine.ui.unit_displays) do display.delete() end
for _, display in pairs(engine.ui.unit_displays) do display.delete() end
-- report ui as not ready
engine.ui_ready = false
@ -157,15 +209,112 @@ function renderer.close_ui()
engine.dmesg_window.redraw()
end
-- is the front panel ready?
---@nodiscard
---@return boolean ready
function renderer.fp_ready() return engine.fp_ready end
-- is the UI ready?
---@nodiscard
---@return boolean ready
function renderer.ui_ready() return engine.ui_ready end
-- handle a monitor peripheral being disconnected
---@param device table monitor
---@return boolean is_used if the monitor is one of the configured monitors
function renderer.handle_disconnect(device)
local is_used = false
if engine.monitors ~= nil then
if engine.monitors.primary == device then
if engine.ui.main_display ~= nil then
-- delete element tree and clear root UI elements
engine.ui.main_display.delete()
end
is_used = true
engine.monitors.primary = nil
engine.ui.main_display = nil
iocontrol.fp_monitor_state(0, false)
else
for idx, monitor in pairs(engine.monitors.unit_displays) do
if monitor == device then
if engine.ui.unit_displays[idx] ~= nil then
engine.ui.unit_displays[idx].delete()
end
is_used = true
engine.monitors.unit_displays[idx] = nil
engine.ui.unit_displays[idx] = nil
iocontrol.fp_monitor_state(idx, false)
break
end
end
end
end
return is_used
end
-- handle a monitor peripheral being reconnected
---@param name string monitor name
---@param device table monitor
---@return boolean is_used if the monitor is one of the configured monitors
function renderer.handle_reconnect(name, device)
local is_used = false
if engine.monitors ~= nil then
if engine.monitors.primary_name == name then
is_used = true
_init_display(device)
engine.monitors.primary = device
local disp_x, disp_y = engine.monitors.primary.getSize()
engine.dmesg_window.reposition(1, 1, disp_x, disp_y, engine.monitors.primary)
if engine.ui_ready and (engine.ui.main_display == nil) then
engine.dmesg_window.setVisible(false)
engine.ui.main_display = DisplayBox{window=device,fg_bg=style.root}
main_view(engine.ui.main_display)
else
engine.dmesg_window.setVisible(true)
engine.dmesg_window.redraw()
end
iocontrol.fp_monitor_state(0, true)
else
for idx, monitor in ipairs(engine.monitors.unit_name_map) do
if monitor == name then
is_used = true
_init_display(device)
engine.monitors.unit_displays[idx] = device
if engine.ui_ready and (engine.ui.unit_displays[idx] == nil) then
engine.ui.unit_displays[idx] = DisplayBox{window=device,fg_bg=style.root}
unit_view(engine.ui.unit_displays[idx], idx)
end
iocontrol.fp_monitor_state(idx, true)
break
end
end
end
end
return is_used
end
-- handle a touch event
---@param event mouse_interaction|nil
function renderer.handle_mouse(event)
if engine.ui_ready and event ~= nil then
if event ~= nil then
if engine.fp_ready and event.monitor == "terminal" then
engine.ui.front_panel.handle_mouse(event)
elseif engine.ui_ready then
if event.monitor == engine.monitors.primary_name then
engine.ui.main_display.handle_mouse(event)
else
@ -173,6 +322,8 @@ function renderer.handle_mouse(event)
if event.monitor == monitor then
local layout = engine.ui.unit_displays[id] ---@type graphics_element
layout.handle_mouse(event)
break
end
end
end
end

View File

@ -4,6 +4,7 @@ local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local config = require("coordinator.config")
local iocontrol = require("coordinator.iocontrol")
local pocket = require("coordinator.session.pocket")
@ -112,6 +113,7 @@ function apisessions.establish_session(source_addr, version)
setmetatable(pkt_s, mt)
iocontrol.fp_pkt_connected(id, version, source_addr)
log.debug(util.c("[API] established new session: ", pkt_s))
self.next_id = id + 1

View File

@ -3,14 +3,14 @@ local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
local pocket = {}
local PROTOCOL = comms.PROTOCOL
-- local CAPI_TYPE = comms.CAPI_TYPE
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local println = util.println
-- retry time constants in ms
-- local INITIAL_WAIT = 1500
-- local RETRY_PERIOD = 1000
@ -69,6 +69,7 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout)
local function _close()
self.conn_watchdog.cancel()
self.connected = false
iocontrol.fp_pkt_disconnected(id)
end
-- send a CAPI packet
@ -140,6 +141,8 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout)
-- log.debug(log_header .. "PKT RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "PKT TT = " .. (srv_now - api_send) .. "ms")
iocontrol.fp_pkt_rtt(id, self.last_rtt)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
@ -172,7 +175,6 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout)
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println("connection to pocket session " .. id .. " closed by server")
log.info(log_header .. "session closed by server")
end
@ -211,7 +213,6 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout)
-- exit if connection was closed
if not self.connected then
println("connection to pocket session " .. id .. " closed by remote host")
log.info(log_header .. "session closed by remote host")
return self.connected
end

View File

@ -4,6 +4,7 @@
require("/initenv").init_env()
local comms = require("scada-common.comms")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local network = require("scada-common.network")
@ -21,7 +22,7 @@ local sounder = require("coordinator.sounder")
local apisessions = require("coordinator.session.apisessions")
local COORDINATOR_VERSION = "v0.17.1"
local COORDINATOR_VERSION = "v0.21.0"
local println = util.println
local println_ts = util.println_ts
@ -30,7 +31,6 @@ local log_graphics = coordinator.log_graphics
local log_sys = coordinator.log_sys
local log_boot = coordinator.log_boot
local log_comms = coordinator.log_comms
local log_comms_connecting = coordinator.log_comms_connecting
local log_crypto = coordinator.log_crypto
----------------------------------------
@ -80,6 +80,9 @@ local function main()
-- mount connected devices
ppm.mount_all()
-- report versions/init fp PSIL
iocontrol.init_fp(COORDINATOR_VERSION, comms.version)
-- setup monitors
local configured, monitors = coordinator.configure_monitors(config.NUM_UNITS)
if not configured or monitors == nil then
@ -127,6 +130,7 @@ local function main()
sounder.init(speaker, config.SOUNDER_VOLUME)
log_boot("tone generation took " .. (util.time_ms() - sounder_start) .. "ms")
log_sys("annunciator alarm configured")
iocontrol.fp_has_speaker(true)
end
----------------------------------------
@ -148,6 +152,7 @@ local function main()
return
else
log_comms("wireless modem connected")
iocontrol.fp_has_modem(true)
end
-- create connection watchdog
@ -167,76 +172,54 @@ local function main()
local loop_clock = util.new_clock(MAIN_CLOCK)
----------------------------------------
-- connect to the supervisor
-- start front panel & UI start function
----------------------------------------
-- attempt to connect to the supervisor or exit
local function init_connect_sv()
local tick_waiting, task_done = log_comms_connecting("attempting to connect to configured supervisor on channel " .. config.SVR_CHANNEL)
log_graphics("starting front panel UI...")
-- attempt to establish a connection with the supervisory computer
if not coord_comms.sv_connect(60, tick_waiting, task_done) then
log_sys("supervisor connection failed, shutting down...")
log.fatal("failed to connect to supervisor")
return false
end
return true
end
if not init_connect_sv() then
println("startup> failed to connect to supervisor")
log_sys("system shutdown")
local fp_ok, fp_message = pcall(renderer.start_fp)
if not fp_ok then
renderer.close_fp()
log_graphics(util.c("front panel UI error: ", fp_message))
println_ts("front panel UI creation failed")
log.fatal(util.c("front panel GUI render failed with error ", fp_message))
return
else
log_sys("supervisor connected, proceeding to UI start")
end
else log_graphics("front panel ready") end
----------------------------------------
-- start the UI
----------------------------------------
-- start up the UI
-- start up the main UI
---@return boolean ui_ok started ok
local function init_start_ui()
log_graphics("starting UI...")
local function start_main_ui()
log_graphics("starting main UI...")
local draw_start = util.time_ms()
local ui_ok, message = pcall(renderer.start_ui)
local ui_ok, ui_message = pcall(renderer.start_ui)
if not ui_ok then
renderer.close_ui()
log_graphics(util.c("UI crashed: ", message))
println_ts("UI crashed")
log.fatal(util.c("GUI crashed with error ", message))
log_graphics(util.c("main UI error: ", ui_message))
log.fatal(util.c("main GUI render failed with error ", ui_message))
else
log_graphics("first UI draw took " .. (util.time_ms() - draw_start) .. "ms")
-- start clock
loop_clock.start()
log_graphics("main UI draw took " .. (util.time_ms() - draw_start) .. "ms")
end
return ui_ok
end
local ui_ok = init_start_ui()
----------------------------------------
-- main event loop
----------------------------------------
local link_failed = false
local ui_ok = true
local date_format = util.trinary(config.TIME_24_HOUR, "%X \x04 %A, %B %d %Y", "%r \x04 %A, %B %d %Y")
if ui_ok then
-- start connection watchdog
conn_watchdog.feed()
log.debug("startup> conn watchdog started")
-- start clock
loop_clock.start()
log_sys("system started successfully")
end
-- main event loop
while ui_ok do
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
-- handle event
@ -250,31 +233,32 @@ local function main()
if nic.is_modem(device) then
nic.disconnect()
log_sys("comms modem disconnected")
println_ts("wireless modem disconnected!")
-- close out UI
local other_modem = ppm.get_wireless_modem()
if other_modem then
log_sys("found another wireless modem, using it for comms")
nic.connect(other_modem)
else
-- close out main UI
renderer.close_ui()
-- alert user to status
log_sys("awaiting comms modem reconnect...")
iocontrol.fp_has_modem(false)
end
else
log_sys("non-comms modem disconnected")
end
elseif type == "monitor" then
if renderer.is_monitor_used(device) then
---@todo will be handled properly in #249
-- "halt and catch fire" style handling
local msg = "lost a configured monitor, system will now exit"
println_ts(msg)
log_sys(msg)
break
if renderer.handle_disconnect(device) then
log_sys("lost a configured monitor")
else
log_sys("lost unused monitor, ignoring")
log_sys("lost an unused monitor")
end
elseif type == "speaker" then
local msg = "lost alarm sounder speaker"
println_ts(msg)
log_sys(msg)
log_sys("lost alarm sounder speaker")
iocontrol.fp_has_speaker(false)
end
end
elseif event == "peripheral" then
@ -282,33 +266,50 @@ local function main()
if type ~= nil and device ~= nil then
if type == "modem" then
if device.isWireless() then
if device.isWireless() and not nic.is_connected() then
-- reconnected modem
nic.connect(device)
log_sys("comms modem reconnected")
println_ts("wireless modem reconnected.")
-- re-init system
if not init_connect_sv() then break end
ui_ok = init_start_ui()
nic.connect(device)
iocontrol.fp_has_modem(true)
elseif device.isWireless() then
log.info("unused wireless modem reconnected")
else
log_sys("wired modem reconnected")
end
-- elseif type == "monitor" then
---@todo will be handled properly in #249
-- not supported, system will exit on loss of in-use monitors
elseif type == "monitor" then
if renderer.handle_reconnect(param1, device) then
log_sys(util.c("configured monitor ", param1, " reconnected"))
else
log_sys(util.c("unused monitor ", param1, " connected"))
end
elseif type == "speaker" then
local msg = "alarm sounder speaker reconnected"
println_ts(msg)
log_sys(msg)
log_sys("alarm sounder speaker reconnected")
sounder.reconnect(device)
iocontrol.fp_has_speaker(true)
end
end
elseif event == "timer" then
if loop_clock.is_clock(param1) then
-- main loop tick
-- toggle heartbeat
iocontrol.heartbeat()
-- maintain connection
if nic.is_connected() then
local ok, start_ui = coord_comms.try_connect()
if not ok then
link_failed = true
log_sys("supervisor connection failed, shutting down...")
log.fatal("failed to connect to supervisor")
break
elseif start_ui then
log_sys("supervisor connected, proceeding to main UI start")
ui_ok = start_main_ui()
if not ui_ok then break end
end
end
-- iterate sessions
apisessions.iterate_all()
@ -316,25 +317,19 @@ local function main()
apisessions.free_all_closed()
-- update date and time string for main display
if coord_comms.is_linked() then
iocontrol.get_db().facility.ps.publish("date_time", os.date(date_format))
end
loop_clock.start()
elseif conn_watchdog.is_timer(param1) then
-- supervisor watchdog timeout
local msg = "supervisor server timeout"
log_comms(msg)
println_ts(msg)
log_comms("supervisor server timeout")
-- close connection, UI, and stop sounder
-- close connection, main UI, and stop sounder
coord_comms.close()
renderer.close_ui()
sounder.stop()
if nic.connected() then
-- try to re-connect to the supervisor
if not init_connect_sv() then break end
ui_ok = init_start_ui()
end
else
-- a non-clock/main watchdog timer event
@ -347,25 +342,19 @@ local function main()
elseif event == "modem_message" then
-- got a packet
local packet = coord_comms.parse_packet(param1, param2, param3, param4, param5)
coord_comms.handle_packet(packet)
-- check if it was a disconnect
if not coord_comms.is_linked() then
-- handle then check if it was a disconnect
if coord_comms.handle_packet(packet) then
log_comms("supervisor closed connection")
-- close connection, UI, and stop sounder
-- close connection, main UI, and stop sounder
coord_comms.close()
renderer.close_ui()
sounder.stop()
if nic.connected() then
-- try to re-connect to the supervisor
if not init_connect_sv() then break end
ui_ok = init_start_ui()
end
end
elseif event == "monitor_touch" then
-- handle a monitor touch event
elseif event == "monitor_touch" or event == "mouse_click" or event == "mouse_up" or
event == "mouse_drag" or event == "mouse_scroll" then
-- handle a mouse event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
elseif event == "speaker_audio_empty" then
-- handle speaker buffer emptied
@ -374,10 +363,17 @@ local function main()
-- check for termination request
if event == "terminate" or ppm.should_terminate() then
println_ts("terminate requested, closing connections...")
-- handle supervisor connection
coord_comms.try_connect(true)
if coord_comms.is_linked() then
log_comms("terminate requested, closing supervisor connection...")
else link_failed = true end
coord_comms.close()
log_comms("supervisor connection closed")
-- handle API sessions
log_comms("closing api sessions...")
apisessions.close_all()
log_comms("api sessions closed")
@ -386,15 +382,20 @@ local function main()
end
renderer.close_ui()
renderer.close_fp()
sounder.stop()
log_sys("system shutdown")
if link_failed then println_ts("failed to connect to supervisor") end
if not ui_ok then println_ts("main UI creation failed") end
println_ts("exited")
log.info("exited")
end
if not xpcall(main, crash.handler) then
pcall(renderer.close_ui)
pcall(renderer.close_fp)
pcall(sounder.stop)
crash.exit()
else

View File

@ -0,0 +1,48 @@
--
-- Pocket Connection Entry
--
local iocontrol = require("coordinator.iocontrol")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create a pocket list entry
---@param parent graphics_element parent
---@param id integer PKT session ID
local function init(parent, id)
local ps = iocontrol.get_db().fp.ps
-- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2,hidden=true}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=cpair(colors.black,colors.white)}
local ps_prefix = "pkt_" .. id .. "_"
TextBox{parent=entry,x=1,y=1,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
local pkt_addr = TextBox{parent=entry,x=1,y=2,text="@ C ??",alignment=TEXT_ALIGN.CENTER,width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray),nav_active=cpair(colors.gray,colors.black)}
TextBox{parent=entry,x=1,y=3,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
pkt_addr.register(ps, ps_prefix .. "addr", pkt_addr.set_value)
TextBox{parent=entry,x=10,y=2,text="FW:",width=3,height=1}
local pkt_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
pkt_fw_v.register(ps, ps_prefix .. "fw", pkt_fw_v.set_value)
TextBox{parent=entry,x=35,y=2,text="RTT:",width=4,height=1}
local pkt_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=cpair(colors.lightGray,colors.white)}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
pkt_rtt.register(ps, ps_prefix .. "rtt", pkt_rtt.update)
pkt_rtt.register(ps, ps_prefix .. "rtt_color", pkt_rtt.recolor)
return root
end
return init

View File

@ -15,8 +15,10 @@ local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local IndicatorLight = require("graphics.elements.indicators.light")
local RadIndicator = require("graphics.elements.indicators.rad")
local StateIndicator = require("graphics.elements.indicators.state")
local TriIndicatorLight = require("graphics.elements.indicators.trilight")
local Checkbox = require("graphics.elements.controls.checkbox")
local HazardButton = require("graphics.elements.controls.hazard_button")
local RadioButton = require("graphics.elements.controls.radio_button")
local SpinboxNumeric = require("graphics.elements.controls.spinbox_numeric")
@ -43,7 +45,7 @@ local function new_view(root, x, y)
local lu_cpair = cpair(colors.gray, colors.gray)
local dis_colors = cpair(colors.white, colors.lightGray)
local main = Div{parent=root,width=104,height=24,x=x,y=y}
local main = Div{parent=root,width=128,height=24,x=x,y=y}
local scram = HazardButton{parent=main,x=1,y=1,text="FAC SCRAM",accent=colors.yellow,dis_colors=dis_colors,callback=process.fac_scram,fg_bg=hzd_fg_bg}
local ack_a = HazardButton{parent=main,x=16,y=1,text="ACK \x13",accent=colors.orange,dis_colors=dis_colors,callback=process.fac_ack_alarms,fg_bg=hzd_fg_bg}
@ -52,12 +54,14 @@ local function new_view(root, x, y)
facility.ack_alarms_ack = ack_a.on_response
local all_ok = IndicatorLight{parent=main,y=5,label="Unit Systems Online",colors=cpair(colors.green,colors.red)}
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=cpair(colors.green,colors.gray)}
local rad_mon = TriIndicatorLight{parent=main,label="Radiation Monitor",c1=colors.gray,c2=colors.yellow,c3=colors.green}
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=cpair(colors.green,colors.gray)}
local sps = IndicatorLight{parent=main,label="SPS Connected",colors=cpair(colors.green,colors.gray)}
all_ok.register(facility.ps, "all_sys_ok", all_ok.update)
ind_mat.register(facility.induction_ps_tbl[1], "computed_status", function (status) ind_mat.update(status > 1) end)
rad_mon.register(facility.ps, "rad_computed_status", rad_mon.update)
ind_mat.register(facility.induction_ps_tbl[1], "computed_status", function (status) ind_mat.update(status > 1) end)
sps.register(facility.sps_ps_tbl[1], "computed_status", function (status) sps.update(status > 1) end)
main.line_break()
@ -99,7 +103,7 @@ local function new_view(root, x, y)
-- process control --
---------------------
local proc = Div{parent=main,width=78,height=24,x=27,y=1}
local proc = Div{parent=main,width=103,height=24,x=27,y=1}
-----------------------------
-- process control targets --
@ -148,54 +152,85 @@ local function new_view(root, x, y)
local rate_limits = {}
for i = 1, facility.num_units do
local unit = units[i] ---@type ioctl_unit
for i = 1, 4 do
local unit
local tag_fg_bg = cpair(colors.gray,colors.white)
local lim_fg_bg = cpair(colors.lightGray,colors.white)
local ctl_fg = colors.lightGray
local cur_fg_bg = cpair(colors.lightGray,colors.white)
local cur_lu = colors.lightGray
if i <= facility.num_units then
unit = units[i] ---@type ioctl_unit
tag_fg_bg = cpair(colors.black,colors.lightBlue)
lim_fg_bg = bw_fg_bg
ctl_fg = colors.gray
cur_fg_bg = cpair(colors.black,colors.brown)
cur_lu = colors.black
end
local _y = ((i - 1) * 5) + 1
local unit_tag = Div{parent=limit_div,x=1,y=_y,width=8,height=4,fg_bg=cpair(colors.black,colors.lightBlue)}
local unit_tag = Div{parent=limit_div,x=1,y=_y,width=8,height=4,fg_bg=tag_fg_bg}
TextBox{parent=unit_tag,x=2,y=2,text="Unit "..i.." Limit",width=7,height=2}
local lim_ctl = Div{parent=limit_div,x=9,y=_y,width=14,height=3,fg_bg=cpair(colors.gray,colors.white)}
rate_limits[i] = SpinboxNumeric{parent=lim_ctl,x=2,y=1,whole_num_precision=4,fractional_precision=1,min=0.1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
local lim_ctl = Div{parent=limit_div,x=9,y=_y,width=14,height=3,fg_bg=cpair(ctl_fg,colors.white)}
local lim = SpinboxNumeric{parent=lim_ctl,x=2,y=1,whole_num_precision=4,fractional_precision=1,min=0.1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=lim_fg_bg}
TextBox{parent=lim_ctl,x=9,y=2,text="mB/t",width=4,height=1}
local cur_burn = DataIndicator{parent=limit_div,x=9,y=_y+3,label="",format="%7.1f",value=0,unit="mB/t",commas=false,lu_colors=cpair(cur_lu,cur_lu),width=14,fg_bg=cur_fg_bg}
if i <= facility.num_units then
rate_limits[i] = lim
rate_limits[i].register(unit.unit_ps, "max_burn", rate_limits[i].set_max)
rate_limits[i].register(unit.unit_ps, "burn_limit", rate_limits[i].set_value)
local cur_burn = DataIndicator{parent=limit_div,x=9,y=_y+3,label="",format="%7.1f",value=0,unit="mB/t",commas=false,lu_colors=cpair(colors.black,colors.black),width=14,fg_bg=cpair(colors.black,colors.brown)}
cur_burn.register(unit.unit_ps, "act_burn_rate", cur_burn.update)
else
lim.disable()
end
end
-------------------
-- unit statuses --
-------------------
local stat_div = Div{parent=proc,width=38,height=19,x=57,y=6}
local stat_div = Div{parent=proc,width=22,height=24,x=57,y=6}
for i = 1, facility.num_units do
local unit = units[i] ---@type ioctl_unit
for i = 1, 4 do
local tag_fg_bg = cpair(colors.gray,colors.white)
local ind_fg_bg = cpair(colors.lightGray,colors.white)
local ind_off = colors.lightGray
if i <= facility.num_units then
tag_fg_bg = cpair(colors.black,colors.cyan)
ind_fg_bg = bw_fg_bg
ind_off = colors.gray
end
local _y = ((i - 1) * 5) + 1
local unit_tag = Div{parent=stat_div,x=1,y=_y,width=8,height=4,fg_bg=cpair(colors.black,colors.lightBlue)}
local unit_tag = Div{parent=stat_div,x=1,y=_y,width=8,height=4,fg_bg=tag_fg_bg}
TextBox{parent=unit_tag,x=2,y=2,text="Unit "..i.." Status",width=7,height=2}
local lights = Div{parent=stat_div,x=9,y=_y,width=12,height=4,fg_bg=bw_fg_bg}
local ready = IndicatorLight{parent=lights,x=2,y=2,label="Ready",colors=cpair(colors.green,colors.gray)}
local degraded = IndicatorLight{parent=lights,x=2,y=3,label="Degraded",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local lights = Div{parent=stat_div,x=9,y=_y,width=14,height=4,fg_bg=ind_fg_bg}
local ready = IndicatorLight{parent=lights,x=2,y=2,label="Ready",colors=cpair(colors.green,ind_off)}
local degraded = IndicatorLight{parent=lights,x=2,y=3,label="Degraded",colors=cpair(colors.red,ind_off),flash=true,period=period.BLINK_250_MS}
if i <= facility.num_units then
local unit = units[i] ---@type ioctl_unit
ready.register(unit.unit_ps, "U_AutoReady", ready.update)
degraded.register(unit.unit_ps, "U_AutoDegraded", degraded.update)
end
end
-------------------------
-- controls and status --
-------------------------
local ctl_opts = { "Monitored Max Burn", "Combined Burn Rate", "Charge Level", "Generation Rate" }
local mode = RadioButton{parent=proc,x=34,y=1,options=ctl_opts,callback=function()end,radio_colors=cpair(colors.purple,colors.black),radio_bg=colors.gray}
local mode = RadioButton{parent=proc,x=34,y=1,options=ctl_opts,callback=function()end,radio_colors=cpair(colors.white,colors.black),radio_bg=colors.purple}
mode.register(facility.ps, "process_mode", mode.set_value)
@ -261,6 +296,60 @@ local function new_view(root, x, y)
for i = 1, #rate_limits do rate_limits[i].enable() end
end
end)
------------------------------
-- waste production control --
------------------------------
local waste_status = Div{parent=proc,width=24,height=4,x=57,y=1,}
for i = 1, facility.num_units do
local unit = units[i] ---@type ioctl_unit
TextBox{parent=waste_status,y=i,text="U"..i.." Waste",width=8,height=1}
local a_waste = IndicatorLight{parent=waste_status,x=10,y=i,label="Auto",colors=cpair(colors.white,colors.gray)}
local waste_m = StateIndicator{parent=waste_status,x=17,y=i,states=style.waste.states_abbrv,value=1,min_width=6}
a_waste.register(unit.unit_ps, "U_AutoWaste", a_waste.update)
waste_m.register(unit.unit_ps, "U_WasteProduct", waste_m.update)
end
local waste_sel = Div{parent=proc,width=21,height=24,x=81,y=1}
TextBox{parent=waste_sel,text=" ",width=21,height=1,x=1,y=1,fg_bg=cpair(colors.black,colors.brown)}
TextBox{parent=waste_sel,text="WASTE PRODUCTION",alignment=TEXT_ALIGN.CENTER,width=21,height=1,x=1,y=2,fg_bg=cpair(colors.lightGray,colors.brown)}
local rect = Rectangle{parent=waste_sel,border=border(1,colors.brown,true),width=21,height=22,x=1,y=3}
local status = StateIndicator{parent=rect,x=2,y=1,states=style.waste.states,value=1,min_width=17}
status.register(facility.ps, "current_waste_product", status.update)
local waste_prod = RadioButton{parent=rect,x=2,y=3,options=style.waste.options,callback=process.set_process_waste,radio_colors=cpair(colors.white,colors.black),radio_bg=colors.brown}
local pu_fallback = Checkbox{parent=rect,x=2,y=7,label="Pu Fallback",callback=process.set_pu_fallback,box_fg_bg=cpair(colors.green,colors.black)}
waste_prod.register(facility.ps, "process_waste_product", waste_prod.set_value)
pu_fallback.register(facility.ps, "process_pu_fallback", pu_fallback.set_value)
local fb_active = IndicatorLight{parent=rect,x=2,y=9,label="Fallback Active",colors=cpair(colors.white,colors.gray)}
fb_active.register(facility.ps, "pu_fallback_active", fb_active.update)
TextBox{parent=rect,x=2,y=11,text="Plutonium Rate",height=1,width=17,fg_bg=style.label}
local pu_rate = DataIndicator{parent=rect,x=2,label="",unit="mB/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
TextBox{parent=rect,x=2,y=14,text="Polonium Rate",height=1,width=17,fg_bg=style.label}
local po_rate = DataIndicator{parent=rect,x=2,label="",unit="mB/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
TextBox{parent=rect,x=2,y=17,text="Antimatter Rate",height=1,width=17,fg_bg=style.label}
local am_rate = DataIndicator{parent=rect,x=2,label="",unit="\xb5B/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
pu_rate.register(facility.ps, "pu_rate", pu_rate.update)
po_rate.register(facility.ps, "po_rate", po_rate.update)
am_rate.register(facility.ps, "am_rate", am_rate.update)
local sna_count = DataIndicator{parent=rect,x=2,y=20,label="Linked SNAs:",format="%4d",value=0,lu_colors=lu_cpair,width=17}
sna_count.register(facility.ps, "sna_count", sna_count.update)
end
return new_view

View File

@ -33,41 +33,21 @@ local border = core.border
local period = core.flasher.PERIOD
local waste_opts = {
{
text = "Auto",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.white, colors.gray)
},
{
text = "Pu",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.green)
},
{
text = "Po",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.cyan)
},
{
text = "AM",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.purple)
}
}
-- create a unit view
---@param parent graphics_element parent
---@param id integer
local function init(parent, id)
local unit = iocontrol.get_db().units[id] ---@type ioctl_unit
local f_ps = iocontrol.get_db().facility.ps
local main = Div{parent=parent,x=1,y=1}
if unit == nil then return main end
local u_ps = unit.unit_ps
local b_ps = unit.boiler_ps_tbl
local t_ps = unit.turbine_ps_tbl
local main = Div{parent=parent,x=1,y=1}
TextBox{parent=main,text="Reactor Unit #" .. id,alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}
local bw_fg_bg = cpair(colors.black, colors.white)
@ -398,7 +378,7 @@ local function init(parent, id)
local waste_proc = Rectangle{parent=main,border=border(1,colors.brown,true),thin=true,width=33,height=3,x=46,y=49}
local waste_div = Div{parent=waste_proc,x=2,y=1,width=31,height=1}
local waste_mode = MultiButton{parent=waste_div,x=1,y=1,options=waste_opts,callback=unit.set_waste,min_width=6}
local waste_mode = MultiButton{parent=waste_div,x=1,y=1,options=style.waste.unit_opts,callback=unit.set_waste,min_width=6}
waste_mode.register(u_ps, "U_WasteMode", waste_mode.set_value)

View File

@ -0,0 +1,121 @@
--
-- Coordinator Front Panel GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
local pgi = require("coordinator.ui.pgi")
local style = require("coordinator.ui.style")
local pkt_entry = require("coordinator.ui.components.pkt_entry")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local ListBox = require("graphics.elements.listbox")
local MultiPane = require("graphics.elements.multipane")
local TextBox = require("graphics.elements.textbox")
local TabBar = require("graphics.elements.controls.tabbar")
local LED = require("graphics.elements.indicators.led")
local RGBLED = require("graphics.elements.indicators.ledrgb")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create new front panel view
---@param panel graphics_element main displaybox
---@param num_units integer number of units (number of unit monitors)
local function init(panel, num_units)
local ps = iocontrol.get_db().fp.ps
TextBox{parent=panel,y=1,text="SCADA COORDINATOR",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.fp.header}
local page_div = Div{parent=panel,x=1,y=3}
--
-- system indicators
--
local main_page = Div{parent=page_div,x=1,y=1}
local system = Div{parent=main_page,width=14,height=17,x=2,y=2}
local status = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=cpair(colors.green,colors.green_off)}
status.update(true)
system.line_break()
heartbeat.register(ps, "heartbeat", heartbeat.update)
local modem = LED{parent=system,label="MODEM",colors=cpair(colors.green,colors.green_off)}
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,colors.gray}}
network.update(types.PANEL_LINK_STATE.DISCONNECTED)
system.line_break()
modem.register(ps, "has_modem", modem.update)
network.register(ps, "link_state", network.update)
local speaker = LED{parent=system,label="SPEAKER",colors=cpair(colors.green,colors.green_off)}
speaker.register(ps, "has_speaker", speaker.update)
---@diagnostic disable-next-line: undefined-field
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=4,width=6,height=1,text=comp_id,fg_bg=cpair(colors.lightGray,colors.ivory)}
local monitors = Div{parent=main_page,width=16,height=17,x=18,y=2}
local main_monitor = LED{parent=monitors,label="MAIN MONITOR",colors=cpair(colors.green,colors.green_off)}
main_monitor.register(ps, "main_monitor", main_monitor.update)
monitors.line_break()
for i = 1, num_units do
local unit_monitor = LED{parent=monitors,label="UNIT "..i.." MONITOR",colors=cpair(colors.green,colors.green_off)}
unit_monitor.register(ps, "unit_monitor_" .. i, unit_monitor.update)
end
--
-- about footer
--
local about = Div{parent=main_page,width=15,height=3,x=1,y=16,fg_bg=cpair(colors.lightGray,colors.ivory)}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00",alignment=TEXT_ALIGN.LEFT,height=1}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00",alignment=TEXT_ALIGN.LEFT,height=1}
fw_v.register(ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
--
-- page handling
--
-- API page
local api_page = Div{parent=page_div,x=1,y=1,hidden=true}
local api_list = ListBox{parent=api_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=cpair(colors.black,colors.ivory),nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=api_list,height=1,hidden=true} -- padding
-- assemble page panes
local panes = { main_page, api_page }
local page_pane = MultiPane{parent=page_div,x=1,y=1,panes=panes}
local tabs = {
{ name = "CRD", color = cpair(colors.black, colors.ivory) },
{ name = "API", color = cpair(colors.black, colors.ivory) },
}
TabBar{parent=panel,y=2,tabs=tabs,min_width=9,callback=page_pane.set_value,fg_bg=cpair(colors.black,colors.white)}
-- link pocket API list management to PGI
pgi.link_elements(api_list, pkt_entry)
end
return init

View File

@ -9,7 +9,7 @@ local iocontrol = require("coordinator.iocontrol")
local style = require("coordinator.ui.style")
local imatrix = require("coordinator.ui.components.imatrix")
local process_ctl = require("coordinator.ui.components.processctl")
local process_ctl = require("coordinator.ui.components.process_ctl")
local unit_overview = require("coordinator.ui.components.unit_overview")
local core = require("graphics.core")

58
coordinator/ui/pgi.lua Normal file
View File

@ -0,0 +1,58 @@
--
-- Protected Graphics Interface
--
local log = require("scada-common.log")
local util = require("scada-common.util")
local pgi = {}
local data = {
pkt_list = nil, ---@type nil|graphics_element
pkt_entry = nil, ---@type function
-- session entries
s_entries = { pkt = {} }
}
-- link list boxes
---@param pkt_list graphics_element pocket list element
---@param pkt_entry function pocket entry constructor
function pgi.link_elements(pkt_list, pkt_entry)
data.pkt_list = pkt_list
data.pkt_entry = pkt_entry
end
-- unlink all fields, disabling the PGI
function pgi.unlink()
data.pkt_list = nil
data.pkt_entry = nil
end
-- add a PKT entry to the PKT list
---@param session_id integer pocket session
function pgi.create_pkt_entry(session_id)
if data.pkt_list ~= nil and data.pkt_entry ~= nil then
local success, result = pcall(data.pkt_entry, data.pkt_list, session_id)
if success then
data.s_entries.pkt[session_id] = result
else
log.error(util.c("PGI: failed to create PKT entry (", result, ")"), true)
end
end
end
-- delete a PKT entry from the PKT list
---@param session_id integer pocket session
function pgi.delete_pkt_entry(session_id)
if data.s_entries.pkt[session_id] ~= nil then
local success, result = pcall(data.s_entries.pkt[session_id].delete)
data.s_entries.pkt[session_id] = nil
if not success then
log.error(util.c("PGI: failed to delete PKT entry (", result, ")"), true)
end
end
end
return pgi

View File

@ -10,6 +10,41 @@ local cpair = core.cpair
-- GLOBAL --
-- add color mappings for front panel
colors.ivory = colors.pink
colors.yellow_hc = colors.purple
colors.red_off = colors.brown
colors.yellow_off = colors.magenta
colors.green_off = colors.lime
-- front panel styling
style.fp = {}
style.fp.root = cpair(colors.black, colors.ivory)
style.fp.header = cpair(colors.black, colors.lightGray)
style.fp.colors = {
{ c = colors.red, hex = 0xdf4949 }, -- RED ON
{ c = colors.orange, hex = 0xffb659 },
{ c = colors.yellow, hex = 0xf9fb53 }, -- YELLOW ON
{ c = colors.lime, hex = 0x16665a }, -- GREEN OFF
{ c = colors.green, hex = 0x6be551 }, -- GREEN ON
{ c = colors.cyan, hex = 0x34bac8 },
{ c = colors.lightBlue, hex = 0x6cc0f2 },
{ c = colors.blue, hex = 0x0096ff },
{ c = colors.purple, hex = 0xb156ee }, -- YELLOW HIGH CONTRAST
{ c = colors.pink, hex = 0xdcd9ca }, -- IVORY
{ c = colors.magenta, hex = 0x85862c }, -- YELLOW OFF
-- { c = colors.white, hex = 0xdcd9ca },
{ c = colors.lightGray, hex = 0xb1b8b3 },
{ c = colors.gray, hex = 0x575757 },
-- { c = colors.black, hex = 0x191919 },
{ c = colors.brown, hex = 0x672223 } -- RED OFF
}
-- main GUI styling
style.root = cpair(colors.black, colors.lightGray)
style.header = cpair(colors.white, colors.gray)
style.label = cpair(colors.gray, colors.lightGray)
@ -151,7 +186,90 @@ style.imatrix = {
{
color = cpair(colors.black, colors.yellow),
text = "HIGH CHARGE"
}
}
}
style.sps = {
-- SPS states
states = {
{
color = cpair(colors.black, colors.yellow),
text = "OFF-LINE"
},
{
color = cpair(colors.black, colors.orange),
text = "NOT FORMED"
},
{
color = cpair(colors.black, colors.orange),
text = "RTU FAULT"
},
{
color = cpair(colors.black, colors.gray),
text = "IDLE"
},
{
color = cpair(colors.black, colors.green),
text = "ACTIVE"
}
}
}
style.waste = {
-- auto waste processing states
states = {
{
color = cpair(colors.black, colors.green),
text = "PLUTONIUM"
},
{
color = cpair(colors.black, colors.cyan),
text = "POLONIUM"
},
{
color = cpair(colors.black, colors.purple),
text = "ANTI MATTER"
}
},
states_abbrv = {
{
color = cpair(colors.black, colors.green),
text = "Pu"
},
{
color = cpair(colors.black, colors.cyan),
text = "Po"
},
{
color = cpair(colors.black, colors.purple),
text = "AM"
}
},
-- process radio button options
options = { "Plutonium", "Polonium", "Antimatter" },
-- unit waste selection
unit_opts = {
{
text = "Auto",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.white, colors.gray)
},
{
text = "Pu",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.green)
},
{
text = "Po",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.cyan)
},
{
text = "AM",
fg_bg = cpair(colors.black, colors.lightGray),
active_fg_bg = cpair(colors.black, colors.purple)
}
}
}

View File

@ -7,7 +7,7 @@ local flasher = require("graphics.flasher")
local core = {}
core.version = "1.0.0"
core.version = "1.0.1"
core.flasher = flasher
core.events = events

View File

@ -20,6 +20,7 @@ local element = {}
---@alias graphics_args graphics_args_generic
---|waiting_args
---|checkbox_args
---|hazard_button_args
---|multi_button_args
---|push_button_args

View File

@ -8,7 +8,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -8,7 +8,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field hidden? boolean true to hide on initial draw
-- new color map

View File

@ -0,0 +1,85 @@
-- Checkbox Graphics Element
local core = require("graphics.core")
local element = require("graphics.element")
---@class checkbox_args
---@field label string checkbox text
---@field box_fg_bg cpair colors for checkbox
---@field callback function function to call on press
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new checkbox control
---@param args checkbox_args
---@return graphics_element element, element_id id
local function checkbox(args)
assert(type(args.label) == "string", "graphics.elements.controls.checkbox: label is a required field")
assert(type(args.box_fg_bg) == "table", "graphics.elements.controls.checkbox: box_fg_bg is a required field")
assert(type(args.callback) == "function", "graphics.elements.controls.checkbox: callback is a required field")
args.height = 1
args.width = 3 + string.len(args.label)
-- create new graphics element base object
local e = element.new(args)
e.value = false
-- show the button state
local function draw()
e.window.setCursorPos(1, 1)
if e.value then
-- show as selected
e.window.setTextColor(args.box_fg_bg.bkg)
e.window.setBackgroundColor(args.box_fg_bg.fgd)
e.window.write("\x88")
e.window.setTextColor(args.box_fg_bg.fgd)
e.window.setBackgroundColor(e.fg_bg.bkg)
e.window.write("\x95")
else
-- show as unselected
e.window.setTextColor(e.fg_bg.bkg)
e.window.setBackgroundColor(args.box_fg_bg.bkg)
e.window.write("\x88")
e.window.setTextColor(args.box_fg_bg.bkg)
e.window.setBackgroundColor(e.fg_bg.bkg)
e.window.write("\x95")
end
end
-- handle mouse interaction
---@param event mouse_interaction mouse event
function e.handle_mouse(event)
if e.enabled and core.events.was_clicked(event.type) then
e.value = not e.value
draw()
args.callback(e.value)
end
end
-- set the value
---@param val integer new value
function e.set_value(val)
e.value = val
draw()
end
-- write label text
e.window.setCursorPos(3, 1)
e.window.setTextColor(e.fg_bg.fgd)
e.window.setBackgroundColor(e.fg_bg.bkg)
e.window.write(args.label)
-- initial draw
draw()
return e.complete()
end
return checkbox

View File

@ -14,7 +14,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -20,7 +20,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -16,7 +16,7 @@ local CLICK_TYPE = core.events.CLICK_TYPE
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -13,7 +13,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -17,7 +17,7 @@ local CLICK_TYPE = core.events.CLICK_TYPE
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -16,7 +16,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -12,7 +12,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -18,7 +18,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -6,7 +6,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -16,7 +16,7 @@ local flasher = require("graphics.flasher")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -11,7 +11,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
-- new core map box
---@nodiscard

View File

@ -14,7 +14,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -10,7 +10,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -16,7 +16,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -14,7 +14,7 @@ local flasher = require("graphics.flasher")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -16,7 +16,7 @@ local flasher = require("graphics.flasher")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -9,7 +9,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -14,7 +14,7 @@ local flasher = require("graphics.flasher")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -13,7 +13,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -14,7 +14,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -15,7 +15,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field height? integer 1 if omitted, must be an odd number
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -16,7 +16,7 @@ local flasher = require("graphics.flasher")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw

View File

@ -8,7 +8,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -15,7 +15,7 @@ local CLICK_TYPE = core.events.CLICK_TYPE
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -7,7 +7,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -11,7 +11,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field hidden? boolean true to hide on initial draw
-- new pipe network

View File

@ -11,7 +11,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -13,7 +13,7 @@ local TEXT_ALIGN = core.TEXT_ALIGN
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -11,7 +11,7 @@ local element = require("graphics.element")
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height

View File

@ -43,9 +43,11 @@ end
-- start/resume the flasher periodic
function flasher.run()
if not active then
active = true
callback_250ms()
end
end
-- clear all blinking indicators and stop the flasher periodic
function flasher.clear()

File diff suppressed because one or more lines are too long

View File

@ -18,7 +18,7 @@ local coreio = require("pocket.coreio")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local POCKET_VERSION = "alpha-v0.5.1"
local POCKET_VERSION = "alpha-v0.5.2"
local println = util.println
local println_ts = util.println_ts
@ -112,7 +112,7 @@ local function main()
if not ui_ok then
renderer.close_ui()
println(util.c("UI error: ", message))
log.error(util.c("startup> GUI crashed with error ", message))
log.error(util.c("startup> GUI render failed with error ", message))
else
-- start clock
loop_clock.start()

View File

@ -1,5 +1,5 @@
--
-- Main SCADA Coordinator GUI
-- Reactor PLC Front Panel GUI
--
local types = require("scada-common.types")
@ -28,7 +28,7 @@ local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
local border = core.border
-- create new main view
-- create new front panel view
---@param panel graphics_element main displaybox
local function init(panel)
local header = TextBox{parent=panel,y=1,text="REACTOR PLC - UNIT ?",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}

View File

@ -12,6 +12,7 @@ local cpair = core.cpair
-- remap global colors
colors.ivory = colors.pink
colors.yellow_hc = colors.purple
colors.red_off = colors.brown
colors.yellow_off = colors.magenta
colors.green_off = colors.lime
@ -28,7 +29,7 @@ style.colors = {
{ c = colors.cyan, hex = 0x34bac8 },
{ c = colors.lightBlue, hex = 0x6cc0f2 },
{ c = colors.blue, hex = 0x0096ff },
{ c = colors.purple, hex = 0xb156ee },
{ c = colors.purple, hex = 0xb156ee }, -- YELLOW HIGH CONTRAST
{ c = colors.pink, hex = 0xdcd9ca }, -- IVORY
{ c = colors.magenta, hex = 0x85862c }, -- YELLOW OFF
-- { c = colors.white, hex = 0xdcd9ca },

View File

@ -929,47 +929,7 @@ function plc.comms(id, version, nic, plc_channel, svr_channel, range, reactor, r
---@cast packet mgmt_frame
-- if linked, only accept packets from configured supervisor
if self.linked then
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- link request confirmation
if packet.length == 1 then
log.debug("received unsolicited establish response")
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
self.status_cache = nil
_send_struct()
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("re-sent initial status data due to re-establish")
else
if est_ack == ESTABLISH_ACK.DENY then
println_ts("received unsolicited link denial, unlinking")
log.warning("unsolicited establish request denied")
elseif est_ack == ESTABLISH_ACK.COLLISION then
println_ts("received unsolicited link collision, unlinking")
log.warning("unsolicited establish request collision")
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
println_ts("received unsolicited link version mismatch, unlinking")
log.warning("unsolicited establish request version mismatch")
else
println_ts("invalid unsolicited link response")
log.debug("unsolicited unknown establish request response")
end
-- unlink
self.sv_addr = comms.BROADCAST
self.linked = false
end
-- clear this since this is for something that was unsolicited
self.last_est_ack = ESTABLISH_ACK.ALLOW
-- report link state
databus.tx_link_state(est_ack + 1)
else
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 and type(packet.data[1]) == "number" then
local timestamp = packet.data[1]

View File

@ -19,7 +19,7 @@ local plc = require("reactor-plc.plc")
local renderer = require("reactor-plc.renderer")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "v1.5.0"
local R_PLC_VERSION = "v1.5.5"
local println = util.println
local println_ts = util.println_ts
@ -190,7 +190,7 @@ local function main()
renderer.close_ui()
println_ts(util.c("UI error: ", message))
println("init> running without front panel")
log.error(util.c("GUI crashed with error ", message))
log.error(util.c("front panel GUI render failed with error ", message))
log.info("init> running in headless mode without front panel")
end
end

View File

@ -77,7 +77,7 @@ function threads.thread__main(smem, init)
loop_clock.start()
-- send updated data
if nic.connected() then
if nic.is_connected() then
if plc_comms.is_linked() then
smem.q.mq_comms_tx.push_command(MQ__COMM_CMD.SEND_STATUS)
else
@ -116,7 +116,7 @@ function threads.thread__main(smem, init)
smem.q.mq_rps.push_command(MQ__RPS_CMD.SCRAM)
-- determine if we are still in a degraded state
if (not networked) or nic.connected() then
if (not networked) or nic.is_connected() then
plc_state.degraded = false
end
@ -146,7 +146,7 @@ function threads.thread__main(smem, init)
-- update indicators
databus.tx_hw_status(plc_state)
elseif event == "modem_message" and networked and plc_state.init_ok and nic.connected() then
elseif event == "modem_message" and networked and plc_state.init_ok and nic.is_connected() then
-- got a packet
local packet = plc_comms.parse_packet(param1, param2, param3, param4, param5)
if packet ~= nil then
@ -177,16 +177,21 @@ function threads.thread__main(smem, init)
nic.disconnect()
println_ts("comms modem disconnected!")
log.error("comms modem disconnected")
log.warning("comms modem disconnected")
local other_modem = ppm.get_wireless_modem()
if other_modem then
log.info("found another wireless modem, using it for comms")
nic.connect(other_modem)
else
plc_state.no_modem = true
plc_state.degraded = true
if plc_state.init_ok then
-- try to scram reactor if it is still connected
smem.q.mq_rps.push_command(MQ__RPS_CMD.DEGRADED_SCRAM)
end
plc_state.degraded = true
end
else
log.warning("non-comms modem disconnected")
end
@ -230,7 +235,7 @@ function threads.thread__main(smem, init)
rps.reset()
end
elseif networked and type == "modem" then
if device.isWireless() then
if device.isWireless() and not nic.is_connected() then
-- reconnected modem
plc_dev.modem = device
plc_state.no_modem = false
@ -244,6 +249,8 @@ function threads.thread__main(smem, init)
if not plc_state.no_reactor then
plc_state.degraded = false
end
elseif device.isWireless() then
log.info("unused wireless modem reconnected")
else
log.info("wired modem reconnected")
end

View File

@ -2,7 +2,7 @@ local rtu = require("rtu.rtu")
local boilerv_rtu = {}
-- create new boiler (mek 10.1+) device
-- create new boiler device
---@nodiscard
---@param boiler table
---@return rtu_device interface, boolean faulted

48
rtu/dev/dynamicv_rtu.lua Normal file
View File

@ -0,0 +1,48 @@
local rtu = require("rtu.rtu")
local dynamicv_rtu = {}
-- create new dynamic tank device
---@nodiscard
---@param dynamic_tank table
---@return rtu_device interface, boolean faulted
function dynamicv_rtu.new(dynamic_tank)
local unit = rtu.init_unit()
-- disable auto fault clearing
dynamic_tank.__p_clear_fault()
dynamic_tank.__p_disable_afc()
-- discrete inputs --
unit.connect_di(dynamic_tank.isFormed)
-- coils --
unit.connect_coil(function () dynamic_tank.incrementContainerEditMode() end, function () end)
unit.connect_coil(function () dynamic_tank.decrementContainerEditMode() end, function () end)
-- input registers --
-- multiblock properties
unit.connect_input_reg(dynamic_tank.getLength)
unit.connect_input_reg(dynamic_tank.getWidth)
unit.connect_input_reg(dynamic_tank.getHeight)
unit.connect_input_reg(dynamic_tank.getMinPos)
unit.connect_input_reg(dynamic_tank.getMaxPos)
-- build properties
unit.connect_input_reg(dynamic_tank.getTankCapacity)
unit.connect_input_reg(dynamic_tank.getChemicalTankCapacity)
-- tanks/containers
unit.connect_input_reg(dynamic_tank.getStored)
unit.connect_input_reg(dynamic_tank.getFilledPercentage)
-- holding registers --
unit.connect_holding_reg(dynamic_tank.getContainerEditMode, dynamic_tank.setContainerEditMode)
-- check if any calls faulted
local faulted = dynamic_tank.__p_is_faulted()
dynamic_tank.__p_clear_fault()
dynamic_tank.__p_enable_afc()
return unit.interface(), faulted
end
return dynamicv_rtu

View File

@ -2,7 +2,7 @@ local rtu = require("rtu.rtu")
local turbinev_rtu = {}
-- create new turbine (mek 10.1+) device
-- create new turbine device
---@nodiscard
---@param turbine table
---@return rtu_device interface, boolean faulted

View File

@ -1,5 +1,5 @@
--
-- Main SCADA Coordinator GUI
-- RTU Front Panel GUI
--
local types = require("scada-common.types")
@ -26,6 +26,7 @@ local UNIT_TYPE_LABELS = {
"REDSTONE",
"BOILER",
"TURBINE",
"DYNAMIC TANK",
"IND MATRIX",
"SPS",
"SNA",
@ -33,7 +34,7 @@ local UNIT_TYPE_LABELS = {
}
-- create new main view
-- create new front panel view
---@param panel graphics_element main displaybox
---@param units table unit list
local function init(panel, units)

View File

@ -12,6 +12,7 @@ local cpair = core.cpair
-- remap global colors
colors.ivory = colors.pink
colors.yellow_hc = colors.purple
colors.red_off = colors.brown
colors.yellow_off = colors.magenta
colors.green_off = colors.lime
@ -28,7 +29,7 @@ style.colors = {
{ c = colors.cyan, hex = 0x34bac8 },
{ c = colors.lightBlue, hex = 0x6cc0f2 },
{ c = colors.blue, hex = 0x0096ff },
{ c = colors.purple, hex = 0xb156ee },
{ c = colors.purple, hex = 0xb156ee }, -- YELLOW HIGH CONTRAST
{ c = colors.pink, hex = 0xdcd9ca }, -- IVORY
{ c = colors.magenta, hex = 0x85862c }, -- YELLOW OFF
-- { c = colors.white, hex = 0xdcd9ca },

View File

@ -22,6 +22,7 @@ local rtu = require("rtu.rtu")
local threads = require("rtu.threads")
local boilerv_rtu = require("rtu.dev.boilerv_rtu")
local dynamicv_rtu = require("rtu.dev.dynamicv_rtu")
local envd_rtu = require("rtu.dev.envd_rtu")
local imatrix_rtu = require("rtu.dev.imatrix_rtu")
local redstone_rtu = require("rtu.dev.redstone_rtu")
@ -29,7 +30,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
local sps_rtu = require("rtu.dev.sps_rtu")
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
local RTU_VERSION = "v1.4.0"
local RTU_VERSION = "v1.5.4"
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
@ -342,6 +343,18 @@ local function main()
log.fatal(util.c("configure> failed to check if '", name, "' is a formed turbine multiblock"))
return false
end
elseif type == "dynamicValve" then
-- dynamic tank multiblock
rtu_type = RTU_UNIT_TYPE.DYNAMIC_VALVE
rtu_iface, faulted = dynamicv_rtu.new(device)
is_multiblock = true
formed = device.isFormed()
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
log.fatal(util.c("configure> failed to check if '", name, "' is a formed dynamic tank multiblock"))
return false
end
elseif type == "inductionPort" then
-- induction matrix multiblock
rtu_type = RTU_UNIT_TYPE.IMATRIX
@ -464,7 +477,7 @@ local function main()
renderer.close_ui()
println_ts(util.c("UI error: ", message))
println("startup> running without front panel")
log.error(util.c("GUI crashed with error ", message))
log.error(util.c("front panel GUI render failed with error ", message))
log.info("startup> running in headless mode without front panel")
end

View File

@ -10,6 +10,7 @@ local modbus = require("rtu.modbus")
local renderer = require("rtu.renderer")
local boilerv_rtu = require("rtu.dev.boilerv_rtu")
local dynamicv_rtu = require("rtu.dev.dynamicv_rtu")
local envd_rtu = require("rtu.dev.envd_rtu")
local imatrix_rtu = require("rtu.dev.imatrix_rtu")
local sna_rtu = require("rtu.dev.sna_rtu")
@ -97,9 +98,15 @@ function threads.thread__main(smem)
nic.disconnect()
println_ts("wireless modem disconnected!")
log.warning("comms modem disconnected!")
log.warning("comms modem disconnected")
local other_modem = ppm.get_wireless_modem()
if other_modem then
log.info("found another wireless modem, using it for comms")
nic.connect(other_modem)
else
databus.tx_hw_modem(false)
end
else
log.warning("non-comms modem disconnected")
end
@ -127,7 +134,7 @@ function threads.thread__main(smem)
if type ~= nil and device ~= nil then
if type == "modem" then
if device.isWireless() then
if device.isWireless() and not nic.is_connected() then
-- reconnected modem
nic.connect(device)
@ -135,6 +142,8 @@ function threads.thread__main(smem)
log.info("comms modem reconnected")
databus.tx_hw_modem(true)
elseif device.isWireless() then
log.info("unused wireless modem reconnected")
else
log.info("wired modem reconnected")
end
@ -181,21 +190,22 @@ function threads.thread__main(smem)
databus.tx_unit_hw_type(unit.uid, unit.type)
end
-- note for multiblock structures: if not formed, indexing the multiblock functions results in a PPM fault
if unit.type == RTU_UNIT_TYPE.BOILER_VALVE then
unit.rtu, faulted = boilerv_rtu.new(device)
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
unit.formed = util.trinary(faulted, false, nil)
elseif unit.type == RTU_UNIT_TYPE.TURBINE_VALVE then
unit.rtu, faulted = turbinev_rtu.new(device)
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
unit.formed = util.trinary(faulted, false, nil)
elseif unit.type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
unit.rtu, faulted = dynamicv_rtu.new(device)
unit.formed = util.trinary(faulted, false, nil)
elseif unit.type == RTU_UNIT_TYPE.IMATRIX then
unit.rtu, faulted = imatrix_rtu.new(device)
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
unit.formed = util.trinary(faulted, false, nil)
elseif unit.type == RTU_UNIT_TYPE.SPS then
unit.rtu, faulted = sps_rtu.new(device)
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
unit.formed = util.trinary(faulted, false, nil)
elseif unit.type == RTU_UNIT_TYPE.SNA then
unit.rtu, faulted = sna_rtu.new(device)
@ -441,6 +451,12 @@ function threads.thread__unit_comms(smem, unit)
unit.rtu, faulted = turbinev_rtu.new(device)
unit.formed = device.isFormed()
unit.modbus_io = modbus.new(unit.rtu, true)
elseif type == "dynamicValve" and unit.type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
-- dynamic tank multiblock
unit.device = device
unit.rtu, faulted = dynamicv_rtu.new(device)
unit.formed = device.isFormed()
unit.modbus_io = modbus.new(unit.rtu, true)
elseif type == "inductionPort" and unit.type == RTU_UNIT_TYPE.IMATRIX then
-- induction matrix multiblock
unit.device = device

View File

@ -14,7 +14,7 @@ local max_distance = nil ---@type number|nil maximum acceptable t
---@class comms
local comms = {}
comms.version = "2.1.0"
comms.version = "2.1.2"
---@enum PROTOCOL
local PROTOCOL = {
@ -92,9 +92,11 @@ local PLC_AUTO_ACK = {
---@enum FAC_COMMAND
local FAC_COMMAND = {
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic control
START = 2, -- start automatic control
ACK_ALL_ALARMS = 3 -- acknowledge all alarms on all units
STOP = 1, -- stop automatic process control
START = 2, -- start automatic process control
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
SET_WASTE_MODE = 4, -- set automatic waste processing mode
SET_PU_FB = 5 -- set plutonium fallback mode
}
---@enum UNIT_COMMAND

View File

@ -20,7 +20,9 @@ local logger = {
mode = MODE.APPEND,
debug = false,
file = nil,
dmesg_out = nil
dmesg_out = nil,
dmesg_restore_coord = { 1, 1 },
dmesg_scroll_count = 0
}
---@type function
@ -158,6 +160,7 @@ function log.dmesg(msg, tag, tag_color)
if cur_y == out_h then
out.scroll(1)
out.setCursorPos(1, cur_y)
logger.dmesg_scroll_count = logger.dmesg_scroll_count + 1
else
out.setCursorPos(1, cur_y + 1)
end
@ -193,6 +196,7 @@ function log.dmesg(msg, tag, tag_color)
if cur_y == out_h then
out.scroll(1)
out.setCursorPos(1, cur_y)
logger.dmesg_scroll_count = logger.dmesg_scroll_count + 1
else
out.setCursorPos(1, cur_y + 1)
end
@ -201,6 +205,8 @@ function log.dmesg(msg, tag, tag_color)
out.write(lines[i])
end
logger.dmesg_restore_coord = { out.getCursorPos() }
_log(util.c("[", t_stamp, "] [", tag, "] ", msg))
end
@ -215,6 +221,7 @@ end
---@return function update, function done
function log.dmesg_working(msg, tag, tag_color)
local ts_coord = log.dmesg(msg, tag, tag_color)
local initial_scroll = logger.dmesg_scroll_count
local out = logger.dmesg_out
local width = (ts_coord.x2 - ts_coord.x1) + 1
@ -225,11 +232,14 @@ function log.dmesg_working(msg, tag, tag_color)
local counter = 0
local function update(sec_remaining)
local new_y = ts_coord.y - (logger.dmesg_scroll_count - initial_scroll)
if new_y < 1 then return end
local time = util.sprintf("%ds", sec_remaining)
local available = width - (string.len(time) + 2)
local progress = ""
out.setCursorPos(ts_coord.x1, ts_coord.y)
out.setCursorPos(ts_coord.x1, new_y)
out.write(" ")
if counter % 4 == 0 then
@ -249,10 +259,15 @@ function log.dmesg_working(msg, tag, tag_color)
out.setTextColor(initial_color)
counter = counter + 1
out.setCursorPos(table.unpack(logger.dmesg_restore_coord))
end
local function done(ok)
out.setCursorPos(ts_coord.x1, ts_coord.y)
local new_y = ts_coord.y - (logger.dmesg_scroll_count - initial_scroll)
if new_y < 1 then return end
out.setCursorPos(ts_coord.x1, new_y)
if ok or ok == nil then
out.setTextColor(colors.green)
@ -263,6 +278,8 @@ function log.dmesg_working(msg, tag, tag_color)
end
out.setTextColor(initial_color)
out.setCursorPos(table.unpack(logger.dmesg_restore_coord))
end
return update, done

View File

@ -94,7 +94,7 @@ function network.nic(modem)
-- check if this NIC has a connected modem
---@nodiscard
function public.connected() return self.connected end
function public.is_connected() return self.connected end
-- connect to a modem peripheral
---@param reconnected_modem table

View File

@ -89,16 +89,18 @@ types.RTU_UNIT_TYPE = {
REDSTONE = 1, -- redstone I/O
BOILER_VALVE = 2, -- boiler mekanism 10.1+
TURBINE_VALVE = 3, -- turbine, mekanism 10.1+
IMATRIX = 4, -- induction matrix
SPS = 5, -- SPS
SNA = 6, -- SNA
ENV_DETECTOR = 7 -- environment detector
DYNAMIC_VALVE = 4, -- dynamic tank, mekanism 10.1+
IMATRIX = 5, -- induction matrix
SPS = 6, -- SPS
SNA = 7, -- SNA
ENV_DETECTOR = 8 -- environment detector
}
types.RTU_UNIT_NAMES = {
"redstone",
"boiler_valve",
"turbine_valve",
"dynamic_valve",
"induction_matrix",
"sps",
"sna",
@ -115,6 +117,7 @@ function types.rtu_type_to_string(utype)
elseif utype == types.RTU_UNIT_TYPE.REDSTONE or
utype == types.RTU_UNIT_TYPE.BOILER_VALVE or
utype == types.RTU_UNIT_TYPE.TURBINE_VALVE or
utype == types.RTU_UNIT_TYPE.DYNAMIC_VALVE or
utype == types.RTU_UNIT_TYPE.IMATRIX or
utype == types.RTU_UNIT_TYPE.SPS or
utype == types.RTU_UNIT_TYPE.SNA or
@ -158,13 +161,26 @@ types.PROCESS_NAMES = {
---@enum WASTE_MODE
types.WASTE_MODE = {
AUTO = 1,
PLUTONIUM = 2,
POLONIUM = 3,
ANTI_MATTER = 4
MANUAL_PLUTONIUM = 2,
MANUAL_POLONIUM = 3,
MANUAL_ANTI_MATTER = 4
}
types.WASTE_MODE_NAMES = {
"AUTO",
"MANUAL_PLUTONIUM",
"MANUAL_POLONIUM",
"MANUAL_ANTI_MATTER"
}
---@enum WASTE_PRODUCT
types.WASTE_PRODUCT = {
PLUTONIUM = 1,
POLONIUM = 2,
ANTI_MATTER = 3
}
types.WASTE_PRODUCT_NAMES = {
"PLUTONIUM",
"POLONIUM",
"ANTI_MATTER"
@ -315,6 +331,17 @@ types.RPS_TRIP_CAUSE = {
FORCE_DISABLED = "force_disabled"
}
---@alias container_mode
---| "BOTH"
---| "FILL"
---| "EMPTY"
types.CONTAINER_MODE = {
BOTH = "BOTH",
FILL = "FILL",
EMPTY = "EMPTY"
}
---@alias dumping_mode
---| "IDLE"
---| "DUMPING"

View File

@ -11,6 +11,9 @@ local rsctl = require("supervisor.session.rsctl")
local PROCESS = types.PROCESS
local PROCESS_NAMES = types.PROCESS_NAMES
local PRIO = types.ALARM_PRIORITY
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local WASTE = types.WASTE_PRODUCT
local WASTE_MODE = types.WASTE_MODE
local IO = rsio.IO
@ -59,8 +62,11 @@ function facility.new(num_reactors, cooling_conf)
all_sys_ok = false,
-- rtus
rtu_conn_count = 0,
rtu_list = {},
redstone = {},
induction = {},
sps = {},
tanks = {},
envd = {},
-- redstone I/O control
io_ctl = nil, ---@type rs_controller
@ -99,6 +105,10 @@ function facility.new(num_reactors, cooling_conf)
last_update = 0,
last_error = 0.0,
last_time = 0.0,
-- waste processing
waste_product = WASTE.PLUTONIUM,
current_waste_product = WASTE.PLUTONIUM,
pu_fallback = false,
-- statistics
im_stat_init = false,
avg_charge = util.mov_avg(3, 0.0),
@ -112,15 +122,12 @@ function facility.new(num_reactors, cooling_conf)
table.insert(self.group_map, 0)
end
-- list for RTU session management
self.rtu_list = { self.redstone, self.induction, self.sps, self.tanks, self.envd }
-- init redstone RTU I/O controller
self.io_ctl = rsctl.new(self.redstone)
-- unlink disconnected units
---@param sessions table
local function _unlink_disconnected_units(sessions)
util.filter_table(sessions, function (u) return u.is_connected() end)
end
-- check if all auto-controlled units completed ramping
---@nodiscard
local function _all_units_ramped()
@ -205,24 +212,50 @@ function facility.new(num_reactors, cooling_conf)
table.insert(self.redstone, rs_unit)
end
-- link an imatrix RTU session
-- link an induction matrix RTU session
---@param imatrix unit_session
---@return boolean linked induction matrix accepted (max 1)
function public.add_imatrix(imatrix)
if #self.induction == 0 then
table.insert(self.induction, imatrix)
return true
else return false end
end
-- link an SPS RTU session
---@param sps unit_session
---@return boolean linked SPS accepted (max 1)
function public.add_sps(sps)
if #self.sps == 0 then
table.insert(self.sps, sps)
return true
else return false end
end
-- link a dynamic tank RTU session
---@param dynamic_tank unit_session
---@return boolean linked dynamic tank accepted (max 1)
function public.add_tank(dynamic_tank)
if #self.tanks == 0 then
table.insert(self.tanks, dynamic_tank)
return true
else return false end
end
-- link an environment detector RTU session
---@param envd unit_session
---@return boolean linked environment detector accepted (max 1)
function public.add_envd(envd)
if #self.envd == 0 then
table.insert(self.envd, envd)
return true
else return false end
end
-- purge devices associated with the given RTU session ID
---@param session integer RTU session ID
function public.purge_rtu_devices(session)
util.filter_table(self.redstone, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.induction, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.envd, function (s) return s.get_session_id() ~= session end)
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (s) return s.get_session_id() ~= session end) end
end
-- UPDATE --
@ -236,9 +269,7 @@ function facility.new(num_reactors, cooling_conf)
-- update (iterate) the facility management
function public.update()
-- unlink RTU unit sessions if they are closed
_unlink_disconnected_units(self.redstone)
_unlink_disconnected_units(self.induction)
_unlink_disconnected_units(self.envd)
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- current state for process control
local charge_update = 0
@ -277,6 +308,8 @@ function facility.new(num_reactors, cooling_conf)
-- Run Process Control --
-------------------------
--#region Process Control
local avg_charge = self.avg_charge.compute()
local avg_inflow = self.avg_inflow.compute()
@ -542,10 +575,14 @@ function facility.new(num_reactors, cooling_conf)
next_mode = PROCESS.INACTIVE
end
--#endregion
------------------------------
-- Evaluate Automatic SCRAM --
------------------------------
--#region Automatic SCRAM
local astatus = self.ascram_status
if self.induction[1] ~= nil then
@ -659,6 +696,8 @@ function facility.new(num_reactors, cooling_conf)
end
end
--#endregion
-- update last mode and set next mode
self.last_mode = self.mode
self.mode = next_mode
@ -692,12 +731,33 @@ function facility.new(num_reactors, cooling_conf)
self.io_ctl.digital_write(IO.F_ALARM, has_alarm)
end
-----------------------------
-- Update Waste Processing --
-----------------------------
local insufficent_po_rate = false
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
if u.get_control_inf().waste_mode == WASTE_MODE.AUTO then
if (u.get_sna_rate() * 10.0) < u.get_burn_rate() then
insufficent_po_rate = true
break
end
end
end
-- call the update function of all units in the facility
if self.waste_product == WASTE.PLUTONIUM or (self.pu_fallback and insufficent_po_rate) then
self.current_waste_product = WASTE.PLUTONIUM
else self.current_waste_product = self.waste_product end
end
-- call the update function of all units in the facility<br>
-- additionally sets the requested auto waste mode if applicable
function public.update_units()
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
u.auto_set_waste(self.current_waste_product)
u.update()
end
end
@ -721,14 +781,14 @@ function facility.new(num_reactors, cooling_conf)
end
-- stop auto control
function public.auto_stop()
self.mode = PROCESS.INACTIVE
end
function public.auto_stop() self.mode = PROCESS.INACTIVE end
-- set automatic control configuration and start the process
---@param config coord_auto_config configuration
---@return table response ready state (successfully started) and current configuration (after updating)
function public.auto_start(config)
local charge_scaler = 1000000 -- convert MFE to FE
local gen_scaler = 1000 -- convert kFE to FE
local ready = false
-- load up current limits
@ -749,11 +809,11 @@ function facility.new(num_reactors, cooling_conf)
end
if (type(config.charge_target) == "number") and config.charge_target >= 0 then
self.charge_setpoint = config.charge_target * 1000000 -- convert MFE to FE
self.charge_setpoint = config.charge_target * charge_scaler
end
if (type(config.gen_target) == "number") and config.gen_target >= 0 then
self.gen_rate_setpoint = config.gen_target * 1000 -- convert kFE to FE
self.gen_rate_setpoint = config.gen_target * gen_scaler
end
if (type(config.limits) == "table") and (#config.limits == num_reactors) then
@ -769,11 +829,9 @@ function facility.new(num_reactors, cooling_conf)
ready = self.mode_set > 0
if (self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0) then
ready = false
elseif (self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0) then
ready = false
elseif (self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1) then
if (self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0) or
(self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0) or
(self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1) then
ready = false
end
@ -782,7 +840,14 @@ function facility.new(num_reactors, cooling_conf)
if ready then self.mode = self.mode_set end
end
return { ready, self.mode_set, self.burn_target, self.charge_setpoint, self.gen_rate_setpoint, limits }
return {
ready,
self.mode_set,
self.burn_target,
self.charge_setpoint / charge_scaler,
self.gen_rate_setpoint / gen_scaler,
limits
}
end
-- SETTINGS --
@ -807,15 +872,35 @@ function facility.new(num_reactors, cooling_conf)
end
end
-- set waste production
---@param product WASTE_PRODUCT target product
---@return WASTE_PRODUCT product newly set value, if valid
function public.set_waste_product(product)
if product == WASTE.PLUTONIUM or product == WASTE.POLONIUM or product == WASTE.ANTI_MATTER then
self.waste_product = product
end
return self.waste_product
end
-- enable/disable plutonium fallback
---@param enabled boolean requested state
---@return boolean enabled newly set value
function public.set_pu_fallback(enabled)
self.pu_fallback = enabled == true
return self.pu_fallback
end
-- READ STATES/PROPERTIES --
-- get build properties of all machines
-- get build properties of all facility devices
---@nodiscard
---@param inc_imatrix boolean? true/nil to include induction matrix build, false to exclude
function public.get_build(inc_imatrix)
---@param type RTU_UNIT_TYPE? type or nil to include only a particular unit type, or to include all if nil
function public.get_build(type)
local all = type == nil
local build = {}
if inc_imatrix ~= false then
if all or type == RTU_UNIT_TYPE.IMATRIX then
build.induction = {}
for i = 1, #self.induction do
local matrix = self.induction[i] ---@type unit_session
@ -823,6 +908,22 @@ function facility.new(num_reactors, cooling_conf)
end
end
if all or type == RTU_UNIT_TYPE.SPS then
build.sps = {}
for i = 1, #self.sps do
local sps = self.sps[i] ---@type unit_session
build.sps[sps.get_device_idx()] = { sps.get_db().formed, sps.get_db().build }
end
end
if all or type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
build.tanks = {}
for i = 1, #self.tanks do
local tank = self.tanks[i] ---@type unit_session
build.tanks[tank.get_device_idx()] = { tank.get_db().formed, tank.get_db().build }
end
end
return build
end
@ -844,7 +945,9 @@ function facility.new(num_reactors, cooling_conf)
astat.gen_fault or self.mode == PROCESS.GEN_RATE_FAULT_IDLE,
self.status_text[1],
self.status_text[2],
self.group_map
self.group_map,
self.current_waste_product,
(self.current_waste_product == WASTE.PLUTONIUM) and (self.waste_product ~= WASTE.PLUTONIUM)
}
end
@ -867,22 +970,31 @@ function facility.new(num_reactors, cooling_conf)
status.induction = {}
for i = 1, #self.induction do
local matrix = self.induction[i] ---@type unit_session
status.induction[matrix.get_device_idx()] = {
matrix.is_faulted(),
matrix.get_db().formed,
matrix.get_db().state,
matrix.get_db().tanks
}
local db = matrix.get_db() ---@type imatrix_session_db
status.induction[matrix.get_device_idx()] = { matrix.is_faulted(), db.formed, db.state, db.tanks }
end
-- status of sps
status.sps = {}
for i = 1, #self.sps do
local sps = self.sps[i] ---@type unit_session
local db = sps.get_db() ---@type sps_session_db
status.sps[sps.get_device_idx()] = { sps.is_faulted(), db.formed, db.state, db.tanks }
end
-- status of dynamic tanks
status.tanks = {}
for i = 1, #self.tanks do
local tank = self.tanks[i] ---@type unit_session
local db = tank.get_db() ---@type dynamicv_session_db
status.tanks[tank.get_device_idx()] = { tank.is_faulted(), db.formed, db.state, db.tanks }
end
-- radiation monitors (environment detectors)
status.rad_mon = {}
for i = 1, #self.envd do
local envd = self.envd[i] ---@type unit_session
status.rad_mon[envd.get_device_idx()] = {
envd.is_faulted(),
envd.get_db().radiation
}
status.rad_mon[envd.get_device_idx()] = { envd.is_faulted(), envd.get_db().radiation }
end
return status

View File

@ -1,5 +1,5 @@
--
-- Main SCADA Coordinator GUI
-- Supervisor Front Panel GUI
--
local util = require("scada-common.util")
@ -29,7 +29,7 @@ local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create new main view
-- create new front panel view
---@param panel graphics_element main displaybox
local function init(panel)
TextBox{parent=panel,y=1,text="SCADA SUPERVISOR",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}

View File

@ -1,7 +1,6 @@
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("supervisor.databus")
@ -16,8 +15,6 @@ local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
local UNIT_COMMAND = comms.UNIT_COMMAND
local FAC_COMMAND = comms.FAC_COMMAND
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local SV_Q_DATA = svqtypes.SV_Q_DATA
-- retry time constants in ms
@ -258,6 +255,18 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
facility.ack_all()
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMAND.SET_WASTE_MODE then
if pkt.length == 2 then
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, facility.set_waste_product(pkt.data[2]) })
else
log.debug(log_header .. "CRDN set waste mode packet length mismatch")
end
elseif cmd == FAC_COMMAND.SET_PU_FB then
if pkt.length == 2 then
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, facility.set_pu_fallback(pkt.data[2]) })
else
log.debug(log_header .. "CRDN set pu fallback packet length mismatch")
end
else
log.debug(log_header .. "CRDN facility command unknown")
end
@ -294,9 +303,9 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
end
elseif cmd == UNIT_COMMAND.SET_WASTE then
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] > 0) and (pkt.data[3] <= 4) then
unit.set_waste(pkt.data[3])
unit.set_waste_mode(pkt.data[3])
else
log.debug(log_header .. "CRDN unit command set waste missing option")
log.debug(log_header .. "CRDN unit command set waste missing/invalid option")
end
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
unit.ack_all()
@ -394,7 +403,7 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
local builds = {}
local unit = self.units[unit_id] ---@type reactor_unit
builds[unit_id] = unit.get_build(true, false, false)
builds[unit_id] = unit.get_build(-1)
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
elseif cmd.key == CRD_S_DATA.RESEND_RTU_BUILD then
@ -408,7 +417,7 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
local builds = {}
local unit = self.units[unit_id] ---@type reactor_unit
builds[unit_id] = unit.get_build(false, cmd.val.type == RTU_UNIT_TYPE.BOILER_VALVE, cmd.val.type == RTU_UNIT_TYPE.TURBINE_VALVE)
builds[unit_id] = unit.get_build(cmd.val.type)
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
else
@ -417,7 +426,7 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
self.retry_times.f_builds_packet = util.time() + PARTIAL_RETRY_PERIOD
self.acks.fac_builds = false
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build(cmd.val.type == RTU_UNIT_TYPE.IMATRIX) })
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build(cmd.val.type) })
end
else
log.error(log_header .. "unsupported data command received in in_queue (this is a bug)", true)

View File

@ -313,17 +313,19 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
if pkt.type == RPLC_TYPE.STATUS then
-- status packet received, update data
if pkt.length >= 5 then
if (type(pkt.data[1]) == "number") and (type(pkt.data[2]) == "boolean") and (type(pkt.data[3]) == "boolean") and
(type(pkt.data[4]) == "boolean") and (type(pkt.data[5]) == "number") then
self.sDB.last_status_update = pkt.data[1]
self.sDB.control_state = pkt.data[2]
self.sDB.no_reactor = pkt.data[3]
self.sDB.formed = pkt.data[4]
self.sDB.auto_ack_token = pkt.data[5]
if not self.sDB.no_reactor and self.sDB.formed then
if (not self.sDB.no_reactor) and self.sDB.formed and (type(pkt.data[6]) == "number") then
self.sDB.mek_status.heating_rate = pkt.data[6] or 0.0
-- attempt to read mek_data table
if pkt.data[7] ~= nil then
if type(pkt.data[7]) == "table" then
local status = pcall(_copy_status, pkt.data[7])
if status then
-- copied in status data OK
@ -334,6 +336,9 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
end
end
end
else
log.debug(log_header .. "RPLC status packet invalid")
end
else
log.debug(log_header .. "RPLC status packet length mismatch")
end

View File

@ -11,6 +11,7 @@ local svqtypes = require("supervisor.session.svqtypes")
-- supervisor rtu sessions (svrs)
local unit_session = require("supervisor.session.rtu.unit_session")
local svrs_boilerv = require("supervisor.session.rtu.boilerv")
local svrs_dynamicv = require("supervisor.session.rtu.dynamicv")
local svrs_envd = require("supervisor.session.rtu.envd")
local svrs_imatrix = require("supervisor.session.rtu.imatrix")
local svrs_redstone = require("supervisor.session.rtu.redstone")
@ -138,6 +139,14 @@ function rtu.new_session(id, s_addr, in_queue, out_queue, timeout, advertisement
-- turbine
unit = svrs_turbinev.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_turbine(unit) end
elseif u_type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
-- dynamic tank
unit = svrs_dynamicv.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_tank(unit) end
elseif u_type == RTU_UNIT_TYPE.SNA then
-- solar neutron activator
unit = svrs_sna.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_sna(unit) end
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
@ -161,9 +170,11 @@ function rtu.new_session(id, s_addr, in_queue, out_queue, timeout, advertisement
elseif u_type == RTU_UNIT_TYPE.SPS then
-- super-critical phase shifter
unit = svrs_sps.new(id, i, unit_advert, self.modbus_q)
elseif u_type == RTU_UNIT_TYPE.SNA then
-- solar neutron activator
unit = svrs_sna.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_sps(unit) end
elseif u_type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
-- dynamic tank
unit = svrs_dynamicv.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_tank(unit) end
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)

View File

@ -0,0 +1,289 @@
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local qtypes = require("supervisor.session.rtu.qtypes")
local unit_session = require("supervisor.session.rtu.unit_session")
local dynamicv = {}
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local CONTAINER_MODE = types.CONTAINER_MODE
local MODBUS_FCODE = types.MODBUS_FCODE
local DTV_RTU_S_CMDS = qtypes.DTV_RTU_S_CMDS
local DTV_RTU_S_DATA = qtypes.DTV_RTU_S_DATA
local TXN_TYPES = {
FORMED = 1,
BUILD = 2,
STATE = 3,
TANKS = 4,
INC_CONT = 5,
DEC_CONT = 6,
SET_CONT = 7
}
local TXN_TAGS = {
"dynamicv.formed",
"dynamicv.build",
"dynamicv.state",
"dynamicv.tanks",
"dynamicv.inc_cont_mode",
"dynamicv.dec_cont_mode",
"dynamicv.set_cont_mode"
}
local PERIODICS = {
FORMED = 2000,
BUILD = 1000,
STATE = 1000,
TANKS = 500
}
-- create a new dynamicv rtu session runner
---@nodiscard
---@param session_id integer RTU session ID
---@param unit_id integer RTU unit ID
---@param advert rtu_advertisement RTU advertisement table
---@param out_queue mqueue RTU unit message out queue
function dynamicv.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPE.DYNAMIC_VALVE then
log.error("attempt to instantiate dynamicv RTU for type '" .. types.rtu_type_to_string(advert.type) .. "'. this is a bug.")
return nil
end
local log_tag = "session.rtu(" .. session_id .. ").dynamicv(" .. advert.index .. "): "
local self = {
session = unit_session.new(session_id, unit_id, advert, out_queue, log_tag, TXN_TAGS),
has_build = false,
periodics = {
next_formed_req = 0,
next_build_req = 0,
next_state_req = 0,
next_tanks_req = 0
},
---@class dynamicv_session_db
db = {
formed = false,
build = {
last_update = 0,
length = 0,
width = 0,
height = 0,
min_pos = types.new_zero_coordinate(),
max_pos = types.new_zero_coordinate(),
tank_capacity = 0,
chem_tank_capacity = 0
},
state = {
last_update = 0,
container_mode = CONTAINER_MODE.BOTH ---@type container_mode
},
tanks = {
last_update = 0,
stored = types.new_empty_gas(),
fill = 0
}
}
}
local public = self.session.get()
-- PRIVATE FUNCTIONS --
-- increment the container mode
local function _inc_cont_mode()
-- write coil 1 with unused value 0
self.session.send_request(TXN_TYPES.INC_CONT, MODBUS_FCODE.WRITE_SINGLE_COIL, { 1, 0 })
end
-- decrement the container mode
local function _dec_cont_mode()
-- write coil 2 with unused value 0
self.session.send_request(TXN_TYPES.DEC_CONT, MODBUS_FCODE.WRITE_SINGLE_COIL, { 2, 0 })
end
-- set the container mode
---@param mode container_mode
local function _set_cont_mode(mode)
-- write holding register 1
self.session.send_request(TXN_TYPES.SET_CONT, MODBUS_FCODE.WRITE_SINGLE_HOLD_REG, { 1, mode })
end
-- query if the multiblock is formed
local function _request_formed()
-- read discrete input 1 (start = 1, count = 1)
self.session.send_request(TXN_TYPES.FORMED, MODBUS_FCODE.READ_DISCRETE_INPUTS, { 1, 1 })
end
-- query the build of the device
local function _request_build()
-- read input registers 1 through 7 (start = 1, count = 7)
self.session.send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 7 })
end
-- query the state of the device
local function _request_state()
-- read holding register 1 (start = 1, count = 1)
self.session.send_request(TXN_TYPES.STATE, MODBUS_FCODE.READ_MUL_HOLD_REGS, { 1, 1 })
end
-- query the tanks of the device
local function _request_tanks()
-- read input registers 8 through 9 (start = 8, count = 2)
self.session.send_request(TXN_TYPES.TANKS, MODBUS_FCODE.READ_INPUT_REGS, { 8, 2 })
end
-- PUBLIC FUNCTIONS --
-- handle a packet
---@param m_pkt modbus_frame
function public.handle_packet(m_pkt)
local txn_type = self.session.try_resolve(m_pkt)
if txn_type == false then
-- nothing to do
elseif txn_type == TXN_TYPES.FORMED then
-- formed response
-- load in data if correct length
if m_pkt.length == 1 then
self.db.formed = m_pkt.data[1]
if not self.db.formed then self.has_build = false end
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")")
end
elseif txn_type == TXN_TYPES.BUILD then
-- build response
if m_pkt.length == 7 then
self.db.build.last_update = util.time_ms()
self.db.build.length = m_pkt.data[1]
self.db.build.width = m_pkt.data[2]
self.db.build.height = m_pkt.data[3]
self.db.build.min_pos = m_pkt.data[4]
self.db.build.max_pos = m_pkt.data[5]
self.db.build.tank_capacity = m_pkt.data[6]
self.db.build.chem_tank_capacity = m_pkt.data[7]
self.has_build = true
out_queue.push_data(unit_session.RTU_US_DATA.BUILD_CHANGED, { unit = advert.reactor, type = advert.type })
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")")
end
elseif txn_type == TXN_TYPES.STATE then
-- state response
if m_pkt.length == 1 then
self.db.state.last_update = util.time_ms()
self.db.state.container_mode = m_pkt.data[1]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")")
end
elseif txn_type == TXN_TYPES.TANKS then
-- tanks response
if m_pkt.length == 2 then
self.db.tanks.last_update = util.time_ms()
self.db.tanks.stored = m_pkt.data[1]
self.db.tanks.fill = m_pkt.data[2]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")")
end
elseif txn_type == TXN_TYPES.INC_CONT or txn_type == TXN_TYPES.DEC_CONT or txn_type == TXN_TYPES.SET_CONT then
-- successful acknowledgement
elseif txn_type == nil then
log.error(log_tag .. "unknown transaction reply")
else
log.error(log_tag .. "unknown transaction type " .. txn_type)
end
end
-- update this runner
---@param time_now integer milliseconds
function public.update(time_now)
-- check command queue
while self.session.in_q.ready() do
-- get a new message to process
local msg = self.session.in_q.pop()
if msg ~= nil then
if msg.qtype == mqueue.TYPE.COMMAND then
-- instruction
local cmd = msg.message
if cmd == DTV_RTU_S_CMDS.INC_CONT_MODE then
_inc_cont_mode()
elseif cmd == DTV_RTU_S_CMDS.DEC_CONT_MODE then
_dec_cont_mode()
else
log.debug(util.c(log_tag, "unrecognized in-queue command ", cmd))
end
elseif msg.qtype == mqueue.TYPE.DATA then
-- instruction with body
local cmd = msg.message ---@type queue_data
if cmd.key == DTV_RTU_S_DATA.SET_CONT_MODE then
if cmd.val == types.CONTAINER_MODE.BOTH or
cmd.val == types.CONTAINER_MODE.FILL or
cmd.val == types.CONTAINER_MODE.EMPTY then
_set_cont_mode(cmd.val)
else
log.debug(util.c(log_tag, "unrecognized container mode \"", cmd.val, "\""))
end
else
log.debug(util.c(log_tag, "unrecognized in-queue data ", cmd.key))
end
end
end
-- max 100ms spent processing queue
if util.time() - time_now > 100 then
log.warning(log_tag .. "exceeded 100ms queue process limit")
break
end
end
time_now = util.time()
-- handle periodics
if self.periodics.next_formed_req <= time_now then
_request_formed()
self.periodics.next_formed_req = time_now + PERIODICS.FORMED
end
if self.db.formed then
if not self.has_build and self.periodics.next_build_req <= time_now then
_request_build()
self.periodics.next_build_req = time_now + PERIODICS.BUILD
end
if self.periodics.next_state_req <= time_now then
_request_state()
self.periodics.next_state_req = time_now + PERIODICS.STATE
end
if self.periodics.next_tanks_req <= time_now then
_request_tanks()
self.periodics.next_tanks_req = time_now + PERIODICS.TANKS
end
end
self.session.post_update()
end
-- invalidate build cache
function public.invalidate_cache()
self.periodics.next_formed_req = 0
self.periodics.next_build_req = 0
self.has_build = false
end
-- get the unit session database
---@nodiscard
function public.get_db() return self.db end
return public
end
return dynamicv

View File

@ -1,16 +1,31 @@
---@class rtu_unit_qtypes
local qtypes = {}
-- turbine valve rtu session commands
local TBV_RTU_S_CMDS = {
INC_DUMP_MODE = 1,
DEC_DUMP_MODE = 2
}
-- turbine valve rtu session commands w/ parameters
local TBV_RTU_S_DATA = {
SET_DUMP_MODE = 1
}
-- dynamic tank valve rtu session commands
local DTV_RTU_S_CMDS = {
INC_CONT_MODE = 1,
DEC_CONT_MODE = 2
}
-- dynamic tank valve rtu session commands w/ parameters
local DTV_RTU_S_DATA = {
SET_CONT_MODE = 1
}
qtypes.TBV_RTU_S_CMDS = TBV_RTU_S_CMDS
qtypes.TBV_RTU_S_DATA = TBV_RTU_S_DATA
qtypes.DTV_RTU_S_CMDS = DTV_RTU_S_CMDS
qtypes.DTV_RTU_S_DATA = DTV_RTU_S_DATA
return qtypes

View File

@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v0.18.0"
local SUPERVISOR_VERSION = "v0.20.2"
local println = util.println
local println_ts = util.println_ts
@ -116,7 +116,7 @@ local function main()
if not fp_ok then
renderer.close_ui()
println_ts(util.c("UI error: ", message))
log.error(util.c("GUI crashed with error ", message))
log.error(util.c("front panel GUI render failed with error ", message))
else
-- redefine println_ts local to not print as we have the front panel running
println_ts = function (_) end
@ -153,7 +153,13 @@ local function main()
println_ts("wireless modem disconnected!")
log.warning("comms modem disconnected")
local other_modem = ppm.get_wireless_modem()
if other_modem then
log.info("found another wireless modem, using it for comms")
nic.connect(other_modem)
else
databus.tx_hw_modem(false)
end
else
log.warning("non-comms modem disconnected")
end
@ -164,7 +170,7 @@ local function main()
if type ~= nil and device ~= nil then
if type == "modem" then
if device.isWireless() and not nic.connected() then
if device.isWireless() and not nic.is_connected() then
-- reconnected modem
nic.connect(device)
@ -172,6 +178,8 @@ local function main()
log.info("comms modem reconnected")
databus.tx_hw_modem(true)
elseif device.isWireless() then
log.info("unused wireless modem reconnected")
else
log.info("wired modem reconnected")
end

View File

@ -12,10 +12,12 @@ local rsctl = require("supervisor.session.rsctl")
local unit = {}
local WASTE_MODE = types.WASTE_MODE
local WASTE = types.WASTE_PRODUCT
local ALARM = types.ALARM
local PRIO = types.ALARM_PRIORITY
local ALARM_STATE = types.ALARM_STATE
local TRI_FAIL = types.TRI_FAIL
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local PLC_S_CMDS = plc.PLC_S_CMDS
@ -68,10 +70,14 @@ function unit.new(reactor_id, num_boilers, num_turbines)
num_turbines = num_turbines,
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
-- rtus
rtu_list = {},
redstone = {},
boilers = {},
turbines = {},
tanks = {},
snas = {},
envd = {},
sna_prod_rate = 0,
-- redstone control
io_ctl = nil, ---@type rs_controller
valves = {}, ---@type unit_valves
@ -89,7 +95,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
damage_start = 0,
damage_last = 0,
damage_est_last = 0,
waste_mode = WASTE_MODE.AUTO,
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
status_text = { "UNKNOWN", "awaiting connection..." },
-- logic for alarms
had_reactor = false,
@ -221,11 +227,15 @@ function unit.new(reactor_id, num_boilers, num_turbines)
degraded = false,
blade_count = 0,
br100 = 0,
lim_br100 = 0
lim_br100 = 0,
waste_mode = WASTE_MODE.AUTO ---@type WASTE_MODE
}
}
}
-- list for RTU session management
self.rtu_list = { self.redstone, self.boilers, self.turbines, self.tanks, self.snas, self.envd }
-- init redstone RTU I/O controller
self.io_ctl = rsctl.new(self.redstone)
@ -341,13 +351,33 @@ function unit.new(reactor_id, num_boilers, num_turbines)
emer_cool = emer_cool
}
--#endregion
-- route reactor waste for a given waste product
---@param product WASTE_PRODUCT waste product to route valves for
local function _set_waste_valves(product)
self.waste_product = product
-- unlink disconnected units
---@param sessions table
local function _unlink_disconnected_units(sessions)
util.filter_table(sessions, function (u) return u.is_connected() end)
if product == WASTE.PLUTONIUM then
-- route through plutonium generation
waste_pu.open()
waste_sna.close()
waste_po.close()
waste_sps.close()
elseif product == WASTE.POLONIUM then
-- route through polonium generation into pellets
waste_pu.close()
waste_sna.open()
waste_po.open()
waste_sps.close()
elseif product == WASTE.ANTI_MATTER then
-- route through polonium generation into SPS
waste_pu.close()
waste_sna.open()
waste_po.close()
waste_sps.open()
end
end
--#endregion
-- PUBLIC FUNCTIONS --
@ -378,11 +408,12 @@ function unit.new(reactor_id, num_boilers, num_turbines)
table.insert(self.redstone, rs_unit)
-- send or re-send waste settings
public.set_waste(self.waste_mode)
_set_waste_valves(self.waste_product)
end
-- link a turbine RTU session
---@param turbine unit_session
---@return boolean linked turbine accepted to associated device slot
function public.add_turbine(turbine)
if #self.turbines < num_turbines and turbine.get_device_idx() <= num_turbines then
table.insert(self.turbines, turbine)
@ -392,13 +423,12 @@ function unit.new(reactor_id, num_boilers, num_turbines)
_reset_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx())
return true
else
return false
end
else return false end
end
-- link a boiler RTU session
---@param boiler unit_session
---@return boolean linked boiler accepted to associated device slot
function public.add_boiler(boiler)
if #self.boilers < num_boilers and boiler.get_device_idx() <= num_boilers then
table.insert(self.boilers, boiler)
@ -410,24 +440,37 @@ function unit.new(reactor_id, num_boilers, num_turbines)
_reset_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx())
return true
else
return false
else return false end
end
-- link a dynamic tank RTU session
---@param dynamic_tank unit_session
---@return boolean linked dynamic tank accepted (max 1)
function public.add_tank(dynamic_tank)
if #self.tanks == 0 then
table.insert(self.tanks, dynamic_tank)
return true
else return false end
end
-- link a solar neutron activator RTU session
---@param sna unit_session
function public.add_sna(sna) table.insert(self.snas, sna) end
-- link an environment detector RTU session
---@param envd unit_session
---@return boolean linked environment detector accepted (max 1)
function public.add_envd(envd)
if #self.envd == 0 then
table.insert(self.envd, envd)
return true
else return false end
end
-- purge devices associated with the given RTU session ID
---@param session integer RTU session ID
function public.purge_rtu_devices(session)
util.filter_table(self.redstone, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.boilers, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.turbines, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.envd, function (s) return s.get_session_id() ~= session end)
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (s) return s.get_session_id() ~= session end) end
end
--#endregion
@ -445,10 +488,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
-- unlink RTU unit sessions if they are closed
_unlink_disconnected_units(self.redstone)
_unlink_disconnected_units(self.boilers)
_unlink_disconnected_units(self.turbines)
_unlink_disconnected_units(self.envd)
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- update degraded state for auto control
self.db.control.degraded = (#self.boilers ~= num_boilers) or (#self.turbines ~= num_turbines) or (self.plc_i == nil)
@ -577,6 +617,15 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
end
-- set automatic waste product if mode is set to auto
---@param product WASTE_PRODUCT waste product to generate
function public.auto_set_waste(product)
if self.db.control.waste_mode == WASTE_MODE.AUTO then
self.waste_product = product
_set_waste_valves(product)
end
end
--#endregion
-- OPERATIONS --
@ -621,34 +670,18 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
end
-- route reactor waste
---@param mode WASTE_MODE waste handling mode
function public.set_waste(mode)
if mode == WASTE_MODE.AUTO then
---@todo automatic waste routing
self.waste_mode = mode
elseif mode == WASTE_MODE.PLUTONIUM then
-- route through plutonium generation
self.waste_mode = mode
waste_pu.open()
waste_sna.close()
waste_po.close()
waste_sps.close()
elseif mode == WASTE_MODE.POLONIUM then
-- route through polonium generation into pellets
self.waste_mode = mode
waste_pu.close()
waste_sna.open()
waste_po.open()
waste_sps.close()
elseif mode == WASTE_MODE.ANTI_MATTER then
-- route through polonium generation into SPS
self.waste_mode = mode
waste_pu.close()
waste_sna.open()
waste_po.close()
waste_sps.open()
else
-- set waste processing mode
---@param mode WASTE_MODE processing mode
function public.set_waste_mode(mode)
self.db.control.waste_mode = mode
if mode == WASTE_MODE.MANUAL_PLUTONIUM then
_set_waste_valves(WASTE.PLUTONIUM)
elseif mode == WASTE_MODE.MANUAL_POLONIUM then
_set_waste_valves(WASTE.POLONIUM)
elseif mode == WASTE_MODE.MANUAL_ANTI_MATTER then
_set_waste_valves(WASTE.ANTI_MATTER)
elseif mode > WASTE_MODE.MANUAL_ANTI_MATTER then
log.debug(util.c("invalid waste mode setting ", mode))
end
end
@ -686,21 +719,25 @@ function unit.new(reactor_id, num_boilers, num_turbines)
return false
end
-- get build properties of all machines
-- get build properties of machines
--
-- filter options
-- - nil to include all builds
-- - -1 to include only PLC build
-- - RTU_UNIT_TYPE to include all builds of machines of that type
---@nodiscard
---@param inc_plc boolean? true/nil to include PLC build, false to exclude
---@param inc_boilers boolean? true/nil to include boiler builds, false to exclude
---@param inc_turbines boolean? true/nil to include turbine builds, false to exclude
function public.get_build(inc_plc, inc_boilers, inc_turbines)
---@param filter -1|RTU_UNIT_TYPE? filter as described above
function public.get_build(filter)
local all = filter == nil
local build = {}
if inc_plc ~= false then
if all or (filter == -1) then
if self.plc_i ~= nil then
build.reactor = self.plc_i.get_struct()
end
end
if inc_boilers ~= false then
if all or (filter == RTU_UNIT_TYPE.BOILER_VALVE) then
build.boilers = {}
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
@ -708,7 +745,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
end
if inc_turbines ~= false then
if all or (filter == RTU_UNIT_TYPE.TURBINE_VALVE) then
build.turbines = {}
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
@ -716,6 +753,14 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
end
if all or (filter == RTU_UNIT_TYPE.DYNAMIC_VALVE) then
build.tanks = {}
for i = 1, #self.tanks do
local tank = self.tanks[i] ---@type unit_session
build.tanks[tank.get_device_idx()] = { tank.get_db().formed, tank.get_db().build }
end
end
return build
end
@ -730,6 +775,14 @@ function unit.new(reactor_id, num_boilers, num_turbines)
return status
end
-- get the current burn rate (actual rate)
---@nodiscard
function public.get_burn_rate()
local rate = 0
if self.plc_i ~= nil then rate = self.plc_i.get_status().act_burn_rate end
return rate or 0
end
-- get RTU statuses
---@nodiscard
function public.get_rtu_statuses()
@ -739,39 +792,53 @@ function unit.new(reactor_id, num_boilers, num_turbines)
status.boilers = {}
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
status.boilers[boiler.get_device_idx()] = {
boiler.is_faulted(),
boiler.get_db().formed,
boiler.get_db().state,
boiler.get_db().tanks
}
local db = boiler.get_db() ---@type boilerv_session_db
status.boilers[boiler.get_device_idx()] = { boiler.is_faulted(), db.formed, db.state, db.tanks }
end
-- status of turbines (including tanks)
status.turbines = {}
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
status.turbines[turbine.get_device_idx()] = {
turbine.is_faulted(),
turbine.get_db().formed,
turbine.get_db().state,
turbine.get_db().tanks
}
local db = turbine.get_db() ---@type turbinev_session_db
status.turbines[turbine.get_device_idx()] = { turbine.is_faulted(), db.formed, db.state, db.tanks }
end
-- status of dynamic tanks
status.tanks = {}
for i = 1, #self.tanks do
local tank = self.tanks[i] ---@type unit_session
local db = tank.get_db() ---@type dynamicv_session_db
status.tanks[tank.get_device_idx()] = { tank.is_faulted(), db.formed, db.state, db.tanks }
end
-- basic SNA statistical information
status.sna = { #self.snas, public.get_sna_rate() }
-- radiation monitors (environment detectors)
status.rad_mon = {}
for i = 1, #self.envd do
local envd = self.envd[i] ---@type unit_session
status.rad_mon[envd.get_device_idx()] = {
envd.is_faulted(),
envd.get_db().radiation
}
status.rad_mon[envd.get_device_idx()] = { envd.is_faulted(), envd.get_db().radiation }
end
return status
end
-- get the current total [max] production rate is
---@nodiscard
---@return number total_avail_rate
function public.get_sna_rate()
local total_avail_rate = 0
for i = 1, #self.snas do
local db = self.snas[i].get_db() ---@type sna_session_db
total_avail_rate = total_avail_rate + db.state.production_rate
end
return total_avail_rate
end
-- get the annunciator status
---@nodiscard
function public.get_annunciator() return self.db.annunciator end
@ -787,7 +854,14 @@ function unit.new(reactor_id, num_boilers, num_turbines)
-- get unit state
---@nodiscard
function public.get_state()
return { self.status_text[1], self.status_text[2], self.waste_mode, self.db.control.ready, self.db.control.degraded }
return {
self.status_text[1],
self.status_text[2],
self.db.control.ready,
self.db.control.degraded,
self.db.control.waste_mode,
self.waste_product
}
end
-- get the reactor ID