#367 reject and record bad or duplicate RTU IDs
This commit is contained in:
@ -37,7 +37,8 @@ local self = {
|
||||
config = nil, ---@type svr_config
|
||||
facility = nil, ---@type facility|nil
|
||||
sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} },
|
||||
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 }
|
||||
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 },
|
||||
dev_dbg = { duplicate = {}, out_of_range = {} }
|
||||
}
|
||||
|
||||
---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct
|
||||
@ -190,6 +191,49 @@ local function _find_session(list, s_addr)
|
||||
return nil
|
||||
end
|
||||
|
||||
local function _update_dev_dbg()
|
||||
local f = function (unit) return unit.is_connected() end
|
||||
|
||||
---@param unit unit_session
|
||||
local on_delete = function (unit)
|
||||
end
|
||||
|
||||
util.filter_table(self.dev_dbg.duplicate, f, on_delete)
|
||||
util.filter_table(self.dev_dbg.out_of_range, f, on_delete)
|
||||
end
|
||||
|
||||
-- SHARED FUNCTIONS --
|
||||
|
||||
---@param unit unit_session RTU session
|
||||
---@param list table table of RTU sessions
|
||||
---@param max integer max of this type of RTU
|
||||
---@return 0|1|2|3 fail_code, string fail_str 0 = success, 1 = out-of-range, 2 = duplicate, 3 = exceeded table max
|
||||
local function check_rtu_id(unit, list, max)
|
||||
local fail_code, fail_str = 0, "OK"
|
||||
|
||||
if (unit.get_device_idx() < 1 and max ~= 1) or unit.get_device_idx() > max then
|
||||
-- out-of-range
|
||||
fail_code, fail_str = 1, "index out of range"
|
||||
table.insert(self.dev_dbg.out_of_range, unit)
|
||||
else
|
||||
for _, u in ipairs(list) do
|
||||
if u.get_device_idx() == unit.get_device_idx() then
|
||||
-- duplicate
|
||||
fail_code, fail_str = 2, "duplicate index"
|
||||
table.insert(self.dev_dbg.duplicate, unit)
|
||||
break
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- make sure this won't exceed the maximum allowable devices
|
||||
if fail_code == 0 and #list >= max then
|
||||
fail_code, fail_str = 3, "too many of this type"
|
||||
end
|
||||
|
||||
return fail_code, fail_str
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- initialize svsessions
|
||||
@ -201,7 +245,7 @@ function svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
self.nic = nic
|
||||
self.fp_ok = fp_ok
|
||||
self.config = config
|
||||
self.facility = facility.new(config, cooling_conf)
|
||||
self.facility = facility.new(config, cooling_conf, check_rtu_id)
|
||||
end
|
||||
|
||||
-- find an RTU session by the computer ID
|
||||
@ -466,6 +510,8 @@ function svsessions.iterate_all()
|
||||
|
||||
-- iterate units
|
||||
self.facility.update_units()
|
||||
|
||||
_update_dev_dbg()
|
||||