#367 reject and record bad or duplicate RTU IDs

This commit is contained in:
Mikayla 2024-08-16 18:08:53 +00:00
parent bee96ed12e
commit ab97f8935d
4 changed files with 113 additions and 35 deletions

View File

@ -65,7 +65,8 @@ local facility = {}
---@nodiscard ---@nodiscard
---@param config svr_config supervisor configuration ---@param config svr_config supervisor configuration
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units ---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
function facility.new(config, cooling_conf) ---@param check_rtu_id function ID checking function for RTUs attempting to be linked
function facility.new(config, cooling_conf, check_rtu_id)
local self = { local self = {
units = {}, units = {},
status_text = { "START UP", "initializing..." }, status_text = { "START UP", "initializing..." },
@ -144,7 +145,7 @@ function facility.new(config, cooling_conf)
-- create units -- create units
for i = 1, config.UnitCount do for i = 1, config.UnitCount do
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling)) table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, check_rtu_id, config.ExtChargeIdling))
table.insert(self.group_map, 0) table.insert(self.group_map, 0)
end end
@ -257,20 +258,30 @@ function facility.new(config, cooling_conf)
---@param imatrix unit_session ---@param imatrix unit_session
---@return boolean linked induction matrix accepted (max 1) ---@return boolean linked induction matrix accepted (max 1)
function public.add_imatrix(imatrix) function public.add_imatrix(imatrix)
if #self.induction == 0 then local fail_code, fail_str = check_rtu_id(imatrix, self.induction, 1)
if fail_code == 0 then
table.insert(self.induction, imatrix) table.insert(self.induction, imatrix)
return true else
else return false end log.warning(util.c("FAC: rejected induction matrix linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end end
-- link an SPS RTU session -- link an SPS RTU session
---@param sps unit_session ---@param sps unit_session
---@return boolean linked SPS accepted (max 1) ---@return boolean linked SPS accepted (max 1)
function public.add_sps(sps) function public.add_sps(sps)
if #self.sps == 0 then local fail_code, fail_str = check_rtu_id(sps, self.sps, 1)
if fail_code == 0 then
table.insert(self.sps, sps) table.insert(self.sps, sps)
return true else
else return false end log.warning(util.c("FAC: rejected SPS linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end end
-- link a dynamic tank RTU session -- link a dynamic tank RTU session
@ -293,7 +304,7 @@ function facility.new(config, cooling_conf)
-- update (iterate) the facility management -- update (iterate) the facility management
function public.update() function public.update()
-- unlink RTU unit sessions if they are closed -- unlink RTU sessions if they are closed
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- check if test routines are allowed right now -- check if test routines are allowed right now

View File

@ -37,7 +37,8 @@ local self = {
config = nil, ---@type svr_config config = nil, ---@type svr_config
facility = nil, ---@type facility|nil facility = nil, ---@type facility|nil
sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} }, sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} },
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 } next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 },
dev_dbg = { duplicate = {}, out_of_range = {} }
} }
---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct ---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct
@ -190,6 +191,49 @@ local function _find_session(list, s_addr)
return nil return nil
end end
local function _update_dev_dbg()
local f = function (unit) return unit.is_connected() end
---@param unit unit_session
local on_delete = function (unit)
end
util.filter_table(self.dev_dbg.duplicate, f, on_delete)
util.filter_table(self.dev_dbg.out_of_range, f, on_delete)
end
-- SHARED FUNCTIONS --
---@param unit unit_session RTU session
---@param list table table of RTU sessions
---@param max integer max of this type of RTU
---@return 0|1|2|3 fail_code, string fail_str 0 = success, 1 = out-of-range, 2 = duplicate, 3 = exceeded table max
local function check_rtu_id(unit, list, max)
local fail_code, fail_str = 0, "OK"
if (unit.get_device_idx() < 1 and max ~= 1) or unit.get_device_idx() > max then
-- out-of-range
fail_code, fail_str = 1, "index out of range"
table.insert(self.dev_dbg.out_of_range, unit)
else
for _, u in ipairs(list) do
if u.get_device_idx() == unit.get_device_idx() then
-- duplicate
fail_code, fail_str = 2, "duplicate index"
table.insert(self.dev_dbg.duplicate, unit)
break
end
end
end
-- make sure this won't exceed the maximum allowable devices
if fail_code == 0 and #list >= max then
fail_code, fail_str = 3, "too many of this type"
end
return fail_code, fail_str
end
-- PUBLIC FUNCTIONS -- -- PUBLIC FUNCTIONS --
-- initialize svsessions -- initialize svsessions
@ -201,7 +245,7 @@ function svsessions.init(nic, fp_ok, config, cooling_conf)
self.nic = nic self.nic = nic
self.fp_ok = fp_ok self.fp_ok = fp_ok
self.config = config self.config = config
self.facility = facility.new(config, cooling_conf) self.facility = facility.new(config, cooling_conf, check_rtu_id)
end end
-- find an RTU session by the computer ID -- find an RTU session by the computer ID
@ -466,6 +510,8 @@ function svsessions.iterate_all()
-- iterate units -- iterate units
self.facility.update_units() self.facility.update_units()
_update_dev_dbg()
end end
-- delete all closed sessions -- delete all closed sessions

View File

@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions") local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v1.4.3" local SUPERVISOR_VERSION = "v1.5.0"
local println = util.println local println = util.println
local println_ts = util.println_ts local println_ts = util.println_ts

View File

@ -63,11 +63,14 @@ local unit = {}
---@param reactor_id integer reactor unit number ---@param reactor_id integer reactor unit number
---@param num_boilers integer number of boilers expected ---@param num_boilers integer number of boilers expected
---@param num_turbines integer number of turbines expected ---@param num_turbines integer number of turbines expected
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
---@param ext_idle boolean extended idling mode ---@param ext_idle boolean extended idling mode
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle) function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
-- time (ms) to idle for auto idling -- time (ms) to idle for auto idling
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000) local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
local log_tag = "UNIT " .. reactor_id .. ": "
---@class _unit_self ---@class _unit_self
local self = { local self = {
r_id = reactor_id, r_id = reactor_id,
@ -441,22 +444,28 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
---@param turbine unit_session ---@param turbine unit_session
---@return boolean linked turbine accepted to associated device slot ---@return boolean linked turbine accepted to associated device slot
function public.add_turbine(turbine) function public.add_turbine(turbine)
if #self.turbines < num_turbines and turbine.get_device_idx() <= num_turbines then local fail_code, fail_str = check_rtu_id(turbine, self.turbines, num_turbines)
if fail_code == 0 then
table.insert(self.turbines, turbine) table.insert(self.turbines, turbine)
-- reset deltas -- reset deltas
_reset_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx()) _reset_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx())
_reset_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx()) _reset_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx())
else
log.warning(util.c(log_tag, "rejected turbine linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return true return fail_code == 0
else return false end
end end
-- link a boiler RTU session -- link a boiler RTU session
---@param boiler unit_session ---@param boiler unit_session
---@return boolean linked boiler accepted to associated device slot ---@return boolean linked boiler accepted to associated device slot
function public.add_boiler(boiler) function public.add_boiler(boiler)
if #self.boilers < num_boilers and boiler.get_device_idx() <= num_boilers then local fail_code, fail_str = check_rtu_id(boiler, self.boilers, num_boilers)
if fail_code == 0 then
table.insert(self.boilers, boiler) table.insert(self.boilers, boiler)
-- reset deltas -- reset deltas
@ -464,19 +473,26 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
_reset_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx()) _reset_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx()) _reset_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx()) _reset_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx())
else
log.warning(util.c(log_tag, "rejected boiler linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return true return fail_code == 0
else return false end
end end
-- link a dynamic tank RTU session -- link a dynamic tank RTU session
---@param dynamic_tank unit_session ---@param dynamic_tank unit_session
---@return boolean linked dynamic tank accepted (max 1) ---@return boolean linked dynamic tank accepted (max 1)
function public.add_tank(dynamic_tank) function public.add_tank(dynamic_tank)
if #self.tanks == 0 then local fail_code, fail_str = check_rtu_id(dynamic_tank, self.tanks, 1)
if fail_code == 0 then
table.insert(self.tanks, dynamic_tank) table.insert(self.tanks, dynamic_tank)
return true else
else return false end log.warning(util.c(log_tag, "rejected dynamic tank linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end end
-- link a solar neutron activator RTU session -- link a solar neutron activator RTU session
@ -487,10 +503,15 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
---@param envd unit_session ---@param envd unit_session
---@return boolean linked environment detector accepted (max 1) ---@return boolean linked environment detector accepted (max 1)
function public.add_envd(envd) function public.add_envd(envd)
if #self.envd == 0 then local fail_code, fail_str = check_rtu_id(envd, self.envd, 99)
if fail_code == 0 then
table.insert(self.envd, envd) table.insert(self.envd, envd)
return true else
else return false end log.warning(util.c(log_tag, "rejected environment detector linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end end
-- purge devices associated with the given RTU session ID -- purge devices associated with the given RTU session ID
@ -512,7 +533,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
self.db.control.br100 = 0 self.db.control.br100 = 0
end end
-- unlink RTU unit sessions if they are closed -- unlink RTU sessions if they are closed
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- update degraded state for auto control -- update degraded state for auto control
@ -547,7 +568,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
-- stop idling when completed -- stop idling when completed
if self.auto_idling and (((util.time_ms() - self.auto_idle_start) > IDLE_TIME) or not self.auto_idle) then if self.auto_idling and (((util.time_ms() - self.auto_idle_start) > IDLE_TIME) or not self.auto_idle) then
log.info(util.c("UNIT ", self.r_id, ": completed idling period")) log.info(util.c(log_tag, "completed idling period"))
self.auto_idling = false self.auto_idling = false
self.plc_i.auto_set_burn(0, false) self.plc_i.auto_set_burn(0, false)
end end
@ -584,7 +605,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_engage() function public.auto_engage()
self.auto_engaged = true self.auto_engaged = true
if self.plc_i ~= nil then if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": engaged auto control")) log.debug(util.c(log_tag, "engaged auto control"))
self.plc_i.auto_lock(true) self.plc_i.auto_lock(true)
end end
end end
@ -593,7 +614,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_disengage() function public.auto_disengage()
self.auto_engaged = false self.auto_engaged = false
if self.plc_i ~= nil then if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": disengaged auto control")) log.debug(util.c(log_tag, "disengaged auto control"))
self.plc_i.auto_lock(false) self.plc_i.auto_lock(false)
self.db.control.br100 = 0 self.db.control.br100 = 0
end end
@ -610,7 +631,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
end end
if idle ~= self.auto_idle then if idle ~= self.auto_idle then
log.debug(util.c("UNIT ", self.r_id, ": idling mode changed to ", idle)) log.debug(util.c(log_tag, "idling mode changed to ", idle))
end end
self.auto_idle = idle self.auto_idle = idle
@ -623,7 +644,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_get_effective_limit() function public.auto_get_effective_limit()
local ctrl = self.db.control local ctrl = self.db.control
if (not ctrl.ready) or ctrl.degraded or self.plc_cache.rps_trip then if (not ctrl.ready) or ctrl.degraded or self.plc_cache.rps_trip then
-- log.debug(util.c("UNIT ", self.r_id, ": effective limit is zero! ready[", ctrl.ready, "] degraded[", ctrl.degraded, "] rps_trip[", self.plc_cache.rps_trip, "]")) -- log.debug(util.c(log_tag, "effective limit is zero! ready[", ctrl.ready, "] degraded[", ctrl.degraded, "] rps_trip[", self.plc_cache.rps_trip, "]"))
ctrl.br100 = 0 ctrl.br100 = 0
return 0 return 0
else return ctrl.lim_br100 end else return ctrl.lim_br100 end
@ -634,7 +655,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_commit_br100(ramp) function public.auto_commit_br100(ramp)
if self.auto_engaged then if self.auto_engaged then
if self.plc_i ~= nil then if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": commit br100 of ", self.db.control.br100, " with ramp set to ", ramp)) log.debug(util.c(log_tag, "commit br100 of ", self.db.control.br100, " with ramp set to ", ramp))
local rate = self.db.control.br100 / 100 local rate = self.db.control.br100 / 100
@ -643,16 +664,16 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
if self.auto_idle_start == 0 then if self.auto_idle_start == 0 then
self.auto_idling = true self.auto_idling = true
self.auto_idle_start = util.time_ms() self.auto_idle_start = util.time_ms()
log.info(util.c("UNIT ", self.r_id, ": started idling at ", IDLE_RATE, " mB/t")) log.info(util.c(log_tag, "started idling at ", IDLE_RATE, " mB/t"))
rate = IDLE_RATE rate = IDLE_RATE
elseif (util.time_ms() - self.auto_idle_start) > IDLE_TIME then elseif (util.time_ms() - self.auto_idle_start) > IDLE_TIME then
if self.auto_idling then if self.auto_idling then
self.auto_idling = false self.auto_idling = false
log.info(util.c("UNIT ", self.r_id, ": completed idling period")) log.info(util.c(log_tag, "completed idling period"))
end end
else else
log.debug(util.c("UNIT ", self.r_id, ": continuing idle at ", IDLE_RATE, " mB/t")) log.debug(util.c(log_tag, "continuing idle at ", IDLE_RATE, " mB/t"))
rate = IDLE_RATE rate = IDLE_RATE
end end