#127 adjusted annunciator rate/feed checks

This commit is contained in:
Mikayla Fischler 2022-11-17 11:20:53 -05:00
parent 6fcd18e17a
commit c93a386e74
4 changed files with 59 additions and 42 deletions

View File

@ -17,7 +17,7 @@ local config = require("coordinator.config")
local coordinator = require("coordinator.coordinator")
local renderer = require("coordinator.renderer")
local COORDINATOR_VERSION = "alpha-v0.6.12"
local COORDINATOR_VERSION = "alpha-v0.6.13"
local print = util.print
local println = util.println

View File

@ -84,16 +84,6 @@ local function init(parent, id)
DataIndicator{parent=main,x=21,label="",format="%6.2f",value=0,unit="mSv/h",lu_colors=lu_cpair,width=12,fg_bg=stat_fg_bg}
main.line_break()
-- TextBox{parent=main,text="FL",x=21,y=19,height=1,width=2,fg_bg=style.label}
-- TextBox{parent=main,text="WS",x=24,y=19,height=1,width=2,fg_bg=style.label}
-- TextBox{parent=main,text="CL",x=28,y=19,height=1,width=2,fg_bg=style.label}
-- TextBox{parent=main,text="HC",x=31,y=19,height=1,width=2,fg_bg=style.label}
-- local fuel = VerticalBar{parent=main,x=21,y=12,fg_bg=cpair(colors.black,colors.gray),height=6,width=2}
-- local waste = VerticalBar{parent=main,x=24,y=12,fg_bg=cpair(colors.brown,colors.gray),height=6,width=2}
-- local ccool = VerticalBar{parent=main,x=28,y=12,fg_bg=cpair(colors.lightBlue,colors.gray),height=6,width=2}
-- local hcool = VerticalBar{parent=main,x=31,y=12,fg_bg=cpair(colors.orange,colors.gray),height=6,width=2}
-- annunciator --
local annunciator = Div{parent=main,x=34,y=3}
@ -164,14 +154,14 @@ local function init(parent, id)
annunciator.line_break()
-- cooling
local c_brm = IndicatorLight{parent=annunciator,label="Boil Rate Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_cfm = IndicatorLight{parent=annunciator,label="Coolant Feed Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_brm = IndicatorLight{parent=annunciator,label="Boil Rate Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_sfm = IndicatorLight{parent=annunciator,label="Steam Feed Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_mwrf = IndicatorLight{parent=annunciator,label="Max Water Return Feed",colors=cpair(colors.yellow,colors.gray)}
local c_tbnt = IndicatorLight{parent=annunciator,label="Turbine Trip",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
r_ps.subscribe("BoilRateMismatch", c_brm.update)
r_ps.subscribe("CoolantFeedMismatch", c_cfm.update)
r_ps.subscribe("BoilRateMismatch", c_brm.update)
r_ps.subscribe("SteamFeedMismatch", c_sfm.update)
r_ps.subscribe("MaxWaterReturnFeed", c_mwrf.update)
r_ps.subscribe("TurbineTrip", c_tbnt.update)
@ -249,6 +239,15 @@ local function init(parent, id)
-- reactor controls --
local burn_control = Div{parent=main,x=2,y=22,width=19,height=3,fg_bg=cpair(colors.gray,colors.white)}
local burn_rate = SpinboxNumeric{parent=burn_control,x=2,y=1,whole_num_precision=4,fractional_precision=1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=cpair(colors.black,colors.white)}
TextBox{parent=burn_control,x=9,y=2,text="mB/t"}
local set_burn = function () unit.set_burn(burn_rate.get_value()) end
PushButton{parent=burn_control,x=14,y=2,text="SET",min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.white,colors.gray),callback=set_burn}
r_ps.subscribe("burn_rate", function (v) burn_rate.set_value(v) end)
local dis_colors = cpair(colors.white, colors.lightGray)
local start = HazardButton{parent=main,x=2,y=26,text="START",accent=colors.lightBlue,dis_colors=dis_colors,callback=unit.start,fg_bg=scram_fg_bg}
@ -270,15 +269,6 @@ local function init(parent, id)
r_ps.subscribe("rps_tripped", start_button_en_check)
r_ps.subscribe("rps_tripped", function (active) if active then reset.enable() else reset.disable() end end)
local burn_control = Div{parent=main,x=2,y=22,width=19,height=3,fg_bg=cpair(colors.gray,colors.white)}
local burn_rate = SpinboxNumeric{parent=burn_control,x=2,y=1,whole_num_precision=4,fractional_precision=1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=cpair(colors.black,colors.white)}
TextBox{parent=burn_control,x=9,y=2,text="mB/t"}
local set_burn = function () unit.set_burn(burn_rate.get_value()) end
PushButton{parent=burn_control,x=14,y=2,text="SET",min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.white,colors.gray),callback=set_burn}
r_ps.subscribe("burn_rate", function (v) burn_rate.set_value(v) end)
local opts = {
{
text = "Auto",

View File

@ -95,7 +95,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
if self.deltas[key] then
local data = self.deltas[key]
if time ~= data.last_t then
if time > data.last_t then
data.dt = (value - data.last_v) / (time - data.last_t)
data.last_v = value
@ -168,6 +168,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
-- update deltas
_dt__compute_all()
-- variables for boiler, or reactor if no boilers used
local total_boil_rate = 0.0
-------------
-- REACTOR --
-------------
@ -192,10 +195,15 @@ function unit.new(for_reactor, num_boilers, num_turbines)
self.db.annunciator.RCSFlowLow = plc_db.mek_status.ccool_fill < 0.75 or plc_db.mek_status.hcool_fill > 0.25
self.db.annunciator.ReactorTempHigh = plc_db.mek_status.temp > 1000
self.db.annunciator.ReactorHighDeltaT = _get_dt(DT_KEYS.ReactorTemp) > 100
self.db.annunciator.FuelInputRateLow = _get_dt(DT_KEYS.ReactorFuel) < 0.0 or plc_db.mek_status.fuel_fill <= 0.01
self.db.annunciator.WasteLineOcclusion = _get_dt(DT_KEYS.ReactorWaste) > 0.0 or plc_db.mek_status.waste_fill >= 0.85
self.db.annunciator.FuelInputRateLow = _get_dt(DT_KEYS.ReactorFuel) < -1.0 or plc_db.mek_status.fuel_fill <= 0.01
self.db.annunciator.WasteLineOcclusion = _get_dt(DT_KEYS.ReactorWaste) > 1.0 or plc_db.mek_status.waste_fill >= 0.85
---@todo this is dependent on setup, i.e. how much coolant is buffered and the turbine setup
self.db.annunciator.HighStartupRate = not plc_db.mek_status.status and plc_db.mek_status.burn_rate > 40
-- if no boilers, use reactor heating rate to check for boil rate mismatch
if self.counts.boilers == 0 then
total_boil_rate = plc_db.mek_status.heating_rate
end
end
-------------
@ -206,10 +214,10 @@ function unit.new(for_reactor, num_boilers, num_turbines)
for i = 1, self.counts.boilers do self.db.annunciator.BoilerOnline[i] = false end
-- aggregated statistics
local total_boil_rate = 0.0
local boiler_steam_dt_sum = 0.0
local boiler_water_dt_sum = 0.0
if self.counts.boilers > 0 then
-- go through boilers for stats and online
for i = 1, #self.boilers do
local session = self.boilers[i] ---@type unit_session
@ -223,7 +231,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
end
-- check heating rate low
if self.plc_s ~= nil then
if self.plc_s ~= nil and #self.boilers > 0 then
local r_db = self.plc_i.get_db()
-- check for inactive boilers while reactor is active
@ -238,25 +246,41 @@ function unit.new(for_reactor, num_boilers, num_turbines)
self.db.annunciator.HeatingRateLow[idx] = false
end
end
-- check for rate mismatch
local expected_boil_rate = r_db.mek_status.heating_rate / 10.0
self.db.annunciator.BoilRateMismatch = math.abs(expected_boil_rate - total_boil_rate) > 25.0
end
else
boiler_steam_dt_sum = _get_dt(DT_KEYS.ReactorHCool)
boiler_water_dt_sum = _get_dt(DT_KEYS.ReactorCCool)
end
-- check coolant feed mismatch
local cfmismatch = false
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
local idx = boiler.get_device_idx()
local db = boiler.get_db() ---@type boilerv_session_db
---------------------------
-- COOLANT FEED MISMATCH --
---------------------------
local gaining_hc = _get_dt(DT_KEYS.BoilerHCool .. idx) > 0 or db.tanks.hcool_fill == 1
-- check coolant feed mismatch if using boilers, otherwise calculate with reactor
local cfmismatch = false
if self.counts.boilers > 0 then
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
local idx = boiler.get_device_idx()
local db = boiler.get_db() ---@type boilerv_session_db
local gaining_hc = _get_dt(DT_KEYS.BoilerHCool .. idx) > 10.0 or db.tanks.hcool_fill == 1
-- gaining heated coolant
cfmismatch = cfmismatch or gaining_hc
-- losing cooled coolant
cfmismatch = cfmismatch or _get_dt(DT_KEYS.BoilerCCool .. idx) < 0 or (gaining_hc and db.tanks.ccool_fill == 0)
cfmismatch = cfmismatch or _get_dt(DT_KEYS.BoilerCCool .. idx) < -10.0 or (gaining_hc and db.tanks.ccool_fill == 0)
end
elseif self.plc_s ~= nil then
local r_db = self.plc_i.get_db()
local gaining_hc = _get_dt(DT_KEYS.ReactorHCool) > 10.0 or r_db.mek_status.hcool_fill == 1
-- gaining heated coolant (steam)
cfmismatch = cfmismatch or gaining_hc
-- losing cooled coolant (water)
cfmismatch = cfmismatch or _get_dt(DT_KEYS.ReactorCCool) < -10.0 or (gaining_hc and r_db.mek_status.ccool_fill == 0)
end
self.db.annunciator.CoolantFeedMismatch = cfmismatch
@ -285,9 +309,12 @@ function unit.new(for_reactor, num_boilers, num_turbines)
self.db.annunciator.TurbineOnline[session.get_device_idx()] = true
end
-- check for boil rate mismatch (either between reactor and turbine or boiler and turbine)
self.db.annunciator.BoilRateMismatch = math.abs(total_boil_rate - total_input_rate) > 4
-- check for steam feed mismatch and max return rate
local sfmismatch = math.abs(total_flow_rate - total_input_rate) > 10
sfmismatch = sfmismatch or boiler_steam_dt_sum > 0 or boiler_water_dt_sum < 0
sfmismatch = sfmismatch or boiler_steam_dt_sum > 2.0 or boiler_water_dt_sum < -2.0
self.db.annunciator.SteamFeedMismatch = sfmismatch
self.db.annunciator.MaxWaterReturnFeed = max_water_return_rate == total_flow_rate and total_flow_rate ~= 0
@ -312,7 +339,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
local db = turbine.get_db() ---@type turbinev_session_db
local idx = turbine.get_device_idx()
self.db.annunciator.TurbineOverSpeed[idx] = (db.state.flow_rate == db.build.max_flow_rate) and (_get_dt(DT_KEYS.TurbineSteam .. idx) > 0)
self.db.annunciator.TurbineOverSpeed[idx] = (db.state.flow_rate == db.build.max_flow_rate) and (_get_dt(DT_KEYS.TurbineSteam .. idx) > 0.0)
end
--[[

View File

@ -14,7 +14,7 @@ local svsessions = require("supervisor.session.svsessions")
local config = require("supervisor.config")
local supervisor = require("supervisor.supervisor")
local SUPERVISOR_VERSION = "beta-v0.7.8"
local SUPERVISOR_VERSION = "beta-v0.7.9"
local print = util.print