mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#308 summary display of supervisor config
This commit is contained in:
@ -95,7 +95,7 @@ local tmp_cfg = {
|
|||||||
UnitCount = 1,
|
UnitCount = 1,
|
||||||
CoolingConfig = {},
|
CoolingConfig = {},
|
||||||
FacilityTankMode = 0,
|
FacilityTankMode = 0,
|
||||||
FacilityTankDefs = nil,
|
FacilityTankDefs = {},
|
||||||
SVR_Channel = nil,
|
SVR_Channel = nil,
|
||||||
PLC_Channel = nil,
|
PLC_Channel = nil,
|
||||||
RTU_Channel = nil,
|
RTU_Channel = nil,
|
||||||
@ -553,7 +553,7 @@ local function config_view(display)
|
|||||||
|
|
||||||
local function submit_mode()
|
local function submit_mode()
|
||||||
tmp_cfg.FacilityTankMode = tank_mode.get_value()
|
tmp_cfg.FacilityTankMode = tank_mode.get_value()
|
||||||
svr_pane.set_value(4)
|
main_pane.set_value(3)
|
||||||
end
|
end
|
||||||
|
|
||||||
PushButton{parent=svr_c_5,x=1,y=14,text="\x1b Back",callback=function()svr_pane.set_value(4)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
PushButton{parent=svr_c_5,x=1,y=14,text="\x1b Back",callback=function()svr_pane.set_value(4)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
@ -889,7 +889,7 @@ local function config_view(display)
|
|||||||
end
|
end
|
||||||
|
|
||||||
-- generate the summary list
|
-- generate the summary list
|
||||||
---@param cfg plc_config
|
---@param cfg svr_config
|
||||||
function tool_ctl.gen_summary(cfg)
|
function tool_ctl.gen_summary(cfg)
|
||||||
setting_list.remove_all()
|
setting_list.remove_all()
|
||||||
|
|
||||||
@ -907,9 +907,39 @@ local function config_view(display)
|
|||||||
local raw = cfg[f[1]]
|
local raw = cfg[f[1]]
|
||||||
local val = util.strval(raw)
|
local val = util.strval(raw)
|
||||||
|
|
||||||
if f[1] == "AuthKey" then val = string.rep("*", string.len(val)) end
|
if f[1] == "AuthKey" then val = string.rep("*", string.len(val))
|
||||||
if f[1] == "LogMode" then val = util.trinary(raw == log.MODE.APPEND, "append", "replace") end
|
elseif f[1] == "LogMode" then val = util.trinary(raw == log.MODE.APPEND, "append", "replace")
|
||||||
if f[1] == "EmerCoolColor" and raw ~= nil then val = rsio.color_name(raw) end
|
elseif f[1] == "CoolingConfig" and cfg.CoolingConfig then
|
||||||
|
val = ""
|
||||||
|
|
||||||
|
for idx = 1, #cfg.CoolingConfig do
|
||||||
|
local ccfg = cfg.CoolingConfig[idx]
|
||||||
|
local b_plural = util.trinary(ccfg.BoilerCount == 1, "", "s")
|
||||||
|
local t_plural = util.trinary(ccfg.TurbineCount == 1, "", "s")
|
||||||
|
local tank = util.trinary(ccfg.TankConnection, "has tank conn", "no tank conn")
|
||||||
|
val = val .. util.trinary(idx == 1, "", "\n") ..
|
||||||
|
util.sprintf(" \x07 unit %d - %d boiler%s, %d turbine%s, %s", idx, ccfg.BoilerCount, b_plural, ccfg.TurbineCount, t_plural, tank)
|
||||||
|
end
|
||||||
|
|
||||||
|
if val == "" then val = "no facility tanks" end
|
||||||
|
elseif f[1] == "FacilityTankMode" and raw == 0 then val = "0 (n/a unit mode)"
|
||||||
|
elseif f[1] == "FacilityTankDefs" and cfg.FacilityTankDefs then
|
||||||
|
val = ""
|
||||||
|
|
||||||
|
for idx = 1, #cfg.FacilityTankDefs do
|
||||||
|
local t_mode = "not connected to a tank"
|
||||||
|
if cfg.FacilityTankDefs[idx] == 1 then
|
||||||
|
t_mode = "connected to its unit tank"
|
||||||
|
elseif cfg.FacilityTankDefs[idx] == 2 then
|
||||||
|
t_mode = "connected to a facility tank"
|
||||||
|
end
|
||||||
|
|
||||||
|
val = val .. util.trinary(idx == 1, "", "\n") .. util.sprintf(" \x07 unit %d - %s", idx, t_mode)
|
||||||
|
end
|
||||||
|
|
||||||
|
if val == "" then val = "no facility tanks" end
|
||||||
|
end
|
||||||
|
|
||||||
if val == "nil" then val = "<not set>" end
|
if val == "nil" then val = "<not set>" end
|
||||||
|
|
||||||
local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
|
local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
|
||||||
|
Reference in New Issue