@ -29,7 +29,7 @@ local annunc = {}
|
||||
annunc.RCSFlowLow_H2O = -3.2 -- flow < -3.2 mB/s
|
||||
annunc.RCSFlowLow_NA = -2.0 -- flow < -2.0 mB/s
|
||||
annunc.CoolantLevelLow = 0.4 -- fill < 40%
|
||||
annunc.ReactorTempHigh = 1000 -- temp > 1000K
|
||||
annunc.OpTempTolerance = 5 -- high temp if >= operational temp + X
|
||||
annunc.ReactorHighDeltaT = 50 -- rate > 50K/s
|
||||
annunc.FuelLevelLow = 0.05 -- fill <= 5%
|
||||
annunc.WasteLevelHigh = 0.80 -- fill >= 80%
|
||||
@ -101,9 +101,11 @@ constants.EXTREME_RADIATION = 100.0
|
||||
---@class _mek_constants
|
||||
local mek = {}
|
||||
|
||||
mek.TURBINE_GAS_PER_TANK = 64000 -- mekanism: turbineGasPerTank
|
||||
mek.TURBINE_DISPERSER_FLOW = 1280 -- mekanism: turbineDisperserGasFlow
|
||||
mek.TURBINE_VENT_FLOW = 32000 -- mekanism: turbineVentGasFlow
|
||||
mek.BASE_BOIL_TEMP = 373.15 -- mekanism: HeatUtils.BASE_BOIL_TEMP
|
||||
mek.JOULES_PER_MB = 1000000 -- mekanism: energyPerFissionFuel
|
||||
mek.TURBINE_GAS_PER_TANK = 64000 -- mekanism: turbineGasPerTank
|
||||
mek.TURBINE_DISPERSER_FLOW = 1280 -- mekanism: turbineDisperserGasFlow
|
||||
mek.TURBINE_VENT_FLOW = 32000 -- mekanism: turbineVentGasFlow
|
||||
|
||||
constants.mek = mek
|
||||
|
||||
|
@ -1,4 +1,5 @@
|
||||
local comms = require("scada-common.comms")
|
||||
local const = require("scada-common.constants")
|
||||
local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local types = require("scada-common.types")
|
||||
@ -105,6 +106,8 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
|
||||
formed = false,
|
||||
rps_tripped = false,
|
||||
rps_trip_cause = "ok", ---@type rps_trip_cause
|
||||
max_op_temp_H2O = 1200,
|
||||
max_op_temp_Na = 1200,
|
||||
---@class rps_status
|
||||
rps_status = {
|
||||
high_dmg = false,
|
||||
@ -138,11 +141,11 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
|
||||
waste = 0,
|
||||
waste_need = 0,
|
||||
waste_fill = 0.0,
|
||||
ccool_type = "?",
|
||||
ccool_type = types.FLUID.EMPTY_GAS, ---@type fluid
|
||||
ccool_amnt = 0,
|
||||
ccool_need = 0,
|
||||
ccool_fill = 0.0,
|
||||
hcool_type = "?",
|
||||
hcool_type = types.FLUID.EMPTY_GAS, ---@type fluid
|
||||
hcool_amnt = 0,
|
||||
hcool_need = 0,
|
||||
hcool_fill = 0.0
|
||||
@ -169,6 +172,21 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
|
||||
---@class plc_session
|
||||
local public = {}
|
||||
|
||||
-- compute maximum expected operational temperatures for high temp warnings
|
||||
local function _compute_op_temps()
|
||||
local JOULES_PER_MB = const.mek.JOULES_PER_MB
|
||||
local BASE_BOIL_TEMP = const.mek.BASE_BOIL_TEMP
|
||||
|
||||
local heat_cap = self.sDB.mek_struct.heat_cap
|
||||
local max_burn = self.sDB.mek_struct.max_burn
|
||||
|
||||
self.sDB.max_op_temp_H2O = max_burn * 2 * (JOULES_PER_MB * heat_cap ^ -1) + BASE_BOIL_TEMP
|
||||
self.sDB.max_op_temp_Na = max_burn * (JOULES_PER_MB * heat_cap ^ -1) + BASE_BOIL_TEMP
|
||||
|
||||
log.info(util.sprintf(log_header .. "computed maximum operational temperatures %.3f (H2O) and %.3f (Na)",
|
||||
self.sDB.max_op_temp_H2O, self.sDB.max_op_temp_Na))
|
||||
end
|
||||
|
||||
-- copy in the RPS status
|
||||
---@param rps_status table
|
||||
local function _copy_rps_status(rps_status)
|
||||
@ -351,6 +369,7 @@ function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, f
|
||||
local status = pcall(_copy_struct, pkt.data)
|
||||
if status then
|
||||
-- copied in structure data OK
|
||||
_compute_op_temps()
|
||||
self.received_struct = true
|
||||
out_queue.push_data(svqtypes.SV_Q_DATA.PLC_BUILD_CHANGED, reactor_id)
|
||||
else
|
||||
|
@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v1.3.7"
|
||||
local SUPERVISOR_VERSION = "v1.3.8"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
@ -147,7 +147,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
},
|
||||
damage = 0,
|
||||
temp = 0,
|
||||
waste = 0
|
||||
waste = 0,
|
||||
high_temp_lim = 1150
|
||||
},
|
||||
---@class alarm_monitors
|
||||
alarms = {
|
||||
|
@ -133,7 +133,15 @@ function logic.update_annunciator(self)
|
||||
self.last_heartbeat = plc_db.last_status_update
|
||||
end
|
||||
|
||||
local flow_low = util.trinary(plc_db.mek_status.ccool_type == types.FLUID.SODIUM, ANNUNC_LIMS.RCSFlowLow_NA, ANNUNC_LIMS.RCSFlowLow_H2O)
|
||||
local flow_low = ANNUNC_LIMS.RCSFlowLow_H2O
|
||||
local high_temp = plc_db.max_op_temp_H2O
|
||||
|
||||
if plc_db.mek_status.ccool_type == types.FLUID.SODIUM then
|
||||
flow_low = ANNUNC_LIMS.RCSFlowLow_NA
|
||||
high_temp = plc_db.max_op_temp_Na
|
||||
end
|
||||
|
||||
self.plc_cache.high_temp_lim = math.min(high_temp + ANNUNC_LIMS.OpTempTolerance, 1200)
|
||||
|
||||
-- update other annunciator fields
|
||||
annunc.ReactorSCRAM = plc_db.rps_tripped
|
||||
@ -142,7 +150,7 @@ function logic.update_annunciator(self)
|
||||
annunc.RCPTrip = plc_db.rps_tripped and (plc_db.rps_status.ex_hcool or plc_db.rps_status.low_cool)
|
||||
annunc.RCSFlowLow = _get_dt(DT_KEYS.ReactorCCool) < flow_low
|
||||
annunc.CoolantLevelLow = plc_db.mek_status.ccool_fill < ANNUNC_LIMS.CoolantLevelLow
|
||||
annunc.ReactorTempHigh = plc_db.mek_status.temp > ANNUNC_LIMS.ReactorTempHigh
|
||||
annunc.ReactorTempHigh = plc_db.mek_status.temp >= self.plc_cache.high_temp_lim
|
||||
annunc.ReactorHighDeltaT = _get_dt(DT_KEYS.ReactorTemp) > ANNUNC_LIMS.ReactorHighDeltaT
|
||||
annunc.FuelInputRateLow = _get_dt(DT_KEYS.ReactorFuel) < -1.0 or plc_db.mek_status.fuel_fill <= ANNUNC_LIMS.FuelLevelLow
|
||||
annunc.WasteLineOcclusion = _get_dt(DT_KEYS.ReactorWaste) > 1.0 or plc_db.mek_status.waste_fill >= ANNUNC_LIMS.WasteLevelHigh
|
||||
@ -542,7 +550,8 @@ function logic.update_alarms(self)
|
||||
end
|
||||
|
||||
-- High Temperature
|
||||
_update_alarm_state(self, plc_cache.temp >= ALARM_LIMS.HIGH_TEMP, self.alarms.ReactorHighTemp)
|
||||
local high_temp = math.min(math.max(self.plc_cache.high_temp_lim, 1100), 1199.995)
|
||||
_update_alarm_state(self, plc_cache.temp >= high_temp, self.alarms.ReactorHighTemp)
|
||||
|
||||
-- Waste Leak
|
||||
_update_alarm_state(self, plc_cache.waste >= 1.0, self.alarms.ReactorWasteLeak)
|
||||
@ -718,11 +727,11 @@ function logic.update_status_text(self)
|
||||
self.status_text[2] = "elevated level of radiation"
|
||||
end
|
||||
elseif is_active(self.alarms.ReactorOverTemp) then
|
||||
self.status_text = { "CORE OVER TEMP", "reactor core temperature >=1200K" }
|
||||
self.status_text = { "CORE OVER TEMP", "reactor core temp damaging" }
|
||||
elseif is_active(self.alarms.ReactorWasteLeak) then
|
||||
self.status_text = { "WASTE LEAK", "radioactive waste leak detected" }
|
||||
elseif is_active(self.alarms.ReactorHighTemp) then
|
||||
self.status_text = { "CORE TEMP HIGH", "reactor core temperature >1150K" }
|
||||
self.status_text = { "CORE TEMP HIGH", "reactor core temperature high" }
|
||||
elseif is_active(self.alarms.ReactorHighWaste) then
|
||||
self.status_text = { "WASTE LEVEL HIGH", "waste accumulating in reactor" }
|
||||
elseif is_active(self.alarms.TurbineTrip) then
|
||||
|