mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#367 reworked ownership of tank data and facility instance to make more sense
This commit is contained in:
parent
4775639245
commit
fc7441b2f6
@ -2,11 +2,11 @@ local log = require("scada-common.log")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local unit = require("supervisor.unit")
|
||||
local fac_update = require("supervisor.facility_update")
|
||||
|
||||
local unit = require("supervisor.unit")
|
||||
|
||||
local rsctl = require("supervisor.session.rsctl")
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local PROCESS = types.PROCESS
|
||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
@ -35,9 +35,7 @@ local facility = {}
|
||||
-- create a new facility management object
|
||||
---@nodiscard
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
|
||||
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
|
||||
function facility.new(config, cooling_conf, check_rtu_id)
|
||||
function facility.new(config)
|
||||
---@class _facility_self
|
||||
local self = {
|
||||
units = {},
|
||||
@ -46,8 +44,13 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
all_sys_ok = false,
|
||||
allow_testing = false,
|
||||
-- facility tanks
|
||||
tank_defs = cooling_conf.fac_tank_defs,
|
||||
tank_list = {},
|
||||
---@class sv_cooling_conf
|
||||
cooling_conf = {
|
||||
r_cool = config.CoolingConfig,
|
||||
fac_tank_mode = config.FacilityTankMode,
|
||||
fac_tank_defs = config.FacilityTankDefs,
|
||||
fac_tank_list = {}
|
||||
},
|
||||
-- rtus
|
||||
rtu_conn_count = 0,
|
||||
rtu_list = {},
|
||||
@ -124,7 +127,8 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
|
||||
-- create units
|
||||
for i = 1, config.UnitCount do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, check_rtu_id, config.ExtChargeIdling))
|
||||
table.insert(self.units,
|
||||
unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.group_map, 0)
|
||||
end
|
||||
|
||||
@ -143,26 +147,28 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
|
||||
--#region decode tank configuration
|
||||
|
||||
local cool_conf = self.cooling_conf
|
||||
|
||||
-- determine tank information
|
||||
if cooling_conf.fac_tank_mode == 0 then
|
||||
self.tank_defs = {}
|
||||
if cool_conf.fac_tank_mode == 0 then
|
||||
cool_conf.tank_defs = {}
|
||||
|
||||
-- on facility tank mode 0, setup tank defs to match unit tank option
|
||||
for i = 1, config.UnitCount do
|
||||
self.tank_defs[i] = util.trinary(cooling_conf.r_cool[i].TankConnection, 1, 0)
|
||||
cool_conf.tank_defs[i] = util.trinary(cool_conf.r_cool[i].TankConnection, 1, 0)
|
||||
end
|
||||
|
||||
self.tank_list = { table.unpack(self.tank_defs) }
|
||||
cool_conf.tank_list = { table.unpack(cool_conf.tank_defs) }
|
||||
else
|
||||
-- decode the layout of tanks from the connections definitions
|
||||
local tank_mode = cooling_conf.fac_tank_mode
|
||||
local tank_defs = self.tank_defs
|
||||
local tank_mode = cool_conf.fac_tank_mode
|
||||
local tank_defs = cool_conf.fac_tank_defs
|
||||
local tank_list = { table.unpack(tank_defs) }
|
||||
|
||||
local function calc_fdef(start_idx, end_idx)
|
||||
local first = 4
|
||||
for i = start_idx, end_idx do
|
||||
if self.tank_defs[i] == 2 then
|
||||
if tank_defs[i] == 2 then
|
||||
if i < first then first = i end
|
||||
end
|
||||
end
|
||||
@ -227,7 +233,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
end
|
||||
end
|
||||
|
||||
self.tank_list = tank_list
|
||||
cool_conf.fac_tank_list = tank_list
|
||||
end
|
||||
|
||||
--#endregion
|
||||
@ -247,7 +253,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
---@param imatrix unit_session
|
||||
---@return boolean linked induction matrix accepted (max 1)
|
||||
function public.add_imatrix(imatrix)
|
||||
local fail_code, fail_str = check_rtu_id(imatrix, self.induction, 1)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(imatrix, self.induction, 1)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.induction, imatrix)
|
||||
@ -262,7 +268,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
---@param sps unit_session
|
||||
---@return boolean linked SPS accepted (max 1)
|
||||
function public.add_sps(sps)
|
||||
local fail_code, fail_str = check_rtu_id(sps, self.sps, 1)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(sps, self.sps, 1)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.sps, sps)
|
||||
@ -303,7 +309,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
f_update.redstone(public.ack_all)
|
||||
|
||||
-- unit tasks
|
||||
f_update.unit_mgmt(cooling_conf)
|
||||
f_update.unit_mgmt()
|
||||
|
||||
-- update alarm tones
|
||||
f_update.alarm_audio()
|
||||
@ -631,6 +637,9 @@ function facility.new(config, cooling_conf, check_rtu_id)
|
||||
---@param rtu_sessions table session list of all connected RTUs
|
||||
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
|
||||
|
||||
-- get the facility cooling configuration
|
||||
function public.get_cooling_conf() return self.cooling_conf end
|
||||
|
||||
-- get the units in this facility
|
||||
---@nodiscard
|
||||
function public.get_units() return self.units end
|
||||
|
@ -766,8 +766,7 @@ function update.redstone(ack_all)
|
||||
end
|
||||
|
||||
-- update unit tasks
|
||||
---@param cooling_conf sv_cooling_conf cooling configuration
|
||||
function update.unit_mgmt(cooling_conf)
|
||||
function update.unit_mgmt()
|
||||
local insufficent_po_rate = false
|
||||
local need_emcool = false
|
||||
|
||||
@ -782,7 +781,7 @@ function update.unit_mgmt(cooling_conf)
|
||||
end
|
||||
|
||||
-- check if unit activated emergency coolant & uses facility tanks
|
||||
if (cooling_conf.fac_tank_mode > 0) and u.is_emer_cool_tripped() and (cooling_conf.fac_tank_defs[i] == 2) then
|
||||
if (self.cooling_conf.fac_tank_mode > 0) and u.is_emer_cool_tripped() and (self.cooling_conf.fac_tank_defs[i] == 2) then
|
||||
need_emcool = true
|
||||
end
|
||||
end
|
||||
|
@ -3,7 +3,6 @@ local mqueue = require("scada-common.mqueue")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local databus = require("supervisor.databus")
|
||||
local facility = require("supervisor.facility")
|
||||
|
||||
local pgi = require("supervisor.panel.pgi")
|
||||
|
||||
@ -45,7 +44,7 @@ local self = {
|
||||
|
||||
---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
--#region PRIVATE FUNCTIONS
|
||||
|
||||
-- handle a session output queue
|
||||
---@param session sv_session_structs
|
||||
@ -208,13 +207,15 @@ local function _update_dev_dbg()
|
||||
end
|
||||
end
|
||||
|
||||
-- SHARED FUNCTIONS --
|
||||
--#endregion
|
||||
|
||||
--#region PUBLIC FUNCTIONS
|
||||
|
||||
---@param unit unit_session RTU session
|
||||
---@param list table table of RTU sessions
|
||||
---@param max integer max of this type of RTU
|
||||
---@return 0|1|2|3 fail_code, string fail_str 0 = success, 1 = out-of-range, 2 = duplicate, 3 = exceeded table max
|
||||
local function check_rtu_id(unit, list, max)
|
||||
function svsessions.check_rtu_id(unit, list, max)
|
||||
local fail_code, fail_str = 0, "OK"
|
||||
|
||||
if (unit.get_device_idx() < 1 and max ~= 1) or unit.get_device_idx() > max then
|
||||
@ -254,18 +255,16 @@ local function check_rtu_id(unit, list, max)
|
||||
return fail_code, fail_str
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- initialize svsessions
|
||||
---@param nic nic network interface device
|
||||
---@param fp_ok boolean front panel active
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configuration definition
|
||||
function svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
---@param facility facility
|
||||
function svsessions.init(nic, fp_ok, config, facility)
|
||||
self.nic = nic
|
||||
self.fp_ok = fp_ok
|
||||
self.config = config
|
||||
self.facility = facility.new(config, cooling_conf, check_rtu_id)
|
||||
self.facility = facility
|
||||
|
||||
-- initialize connection tracking table
|
||||
self.dev_dbg.connected = { imatrix = nil, sps = nil, tanks = {}, units = {} }
|
||||
@ -554,4 +553,6 @@ function svsessions.close_all()
|
||||
svsessions.free_all_closed()
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
return svsessions
|
||||
|
@ -16,6 +16,7 @@ local core = require("graphics.core")
|
||||
|
||||
local configure = require("supervisor.configure")
|
||||
local databus = require("supervisor.databus")
|
||||
local facility = require("supervisor.facility")
|
||||
local renderer = require("supervisor.renderer")
|
||||
local supervisor = require("supervisor.supervisor")
|
||||
|
||||
@ -129,9 +130,12 @@ local function main()
|
||||
println_ts = function (_) end
|
||||
end
|
||||
|
||||
-- create facility and unit objects
|
||||
local sv_facility = facility.new(config)
|
||||
|
||||
-- create network interface then setup comms
|
||||
local nic = network.nic(modem)
|
||||
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, nic, fp_ok)
|
||||
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, nic, fp_ok, sv_facility)
|
||||
|
||||
-- base loop clock (6.67Hz, 3 ticks)
|
||||
local MAIN_CLOCK = 0.15
|
||||
|
@ -102,14 +102,12 @@ end
|
||||
---@param _version string supervisor version
|
||||
---@param nic nic network interface device
|
||||
---@param fp_ok boolean if the front panel UI is running
|
||||
---@param facility facility facility instance
|
||||
---@diagnostic disable-next-line: unused-local
|
||||
function supervisor.comms(_version, nic, fp_ok)
|
||||
function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
-- print a log message to the terminal as long as the UI isn't running
|
||||
local function println(message) if not fp_ok then util.println_ts(message) end end
|
||||
|
||||
---@class sv_cooling_conf
|
||||
local cooling_conf = { r_cool = config.CoolingConfig, fac_tank_mode = config.FacilityTankMode, fac_tank_defs = config.FacilityTankDefs }
|
||||
|
||||
local self = {
|
||||
last_est_acks = {}
|
||||
}
|
||||
@ -122,8 +120,8 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
nic.closeAll()
|
||||
nic.open(config.SVR_Channel)
|
||||
|
||||
-- pass modem, status, and config data to svsessions
|
||||
svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
-- pass system data and objects to svsessions
|
||||
svsessions.init(nic, fp_ok, config, facility)
|
||||
|
||||
-- send an establish request response
|
||||
---@param packet scada_packet
|
||||
@ -373,7 +371,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, facility.get_cooling_conf() })
|
||||
else
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
|
@ -1,12 +1,13 @@
|
||||
local log = require("scada-common.log")
|
||||
local rsio = require("scada-common.rsio")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
local log = require("scada-common.log")
|
||||
local rsio = require("scada-common.rsio")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local logic = require("supervisor.unitlogic")
|
||||
local logic = require("supervisor.unitlogic")
|
||||
|
||||
local plc = require("supervisor.session.plc")
|
||||
local rsctl = require("supervisor.session.rsctl")
|
||||
local plc = require("supervisor.session.plc")
|
||||
local rsctl = require("supervisor.session.rsctl")
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local WASTE_MODE = types.WASTE_MODE
|
||||
local WASTE = types.WASTE_PRODUCT
|
||||
@ -63,9 +64,8 @@ local unit = {}
|
||||
---@param reactor_id integer reactor unit number
|
||||
---@param num_boilers integer number of boilers expected
|
||||
---@param num_turbines integer number of turbines expected
|
||||
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
|
||||
---@param ext_idle boolean extended idling mode
|
||||
function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
|
||||
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
-- time (ms) to idle for auto idling
|
||||
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
|
||||
|
||||
@ -444,7 +444,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
|
||||
---@param turbine unit_session
|
||||
---@return boolean linked turbine accepted to associated device slot
|
||||
function public.add_turbine(turbine)
|
||||
local fail_code, fail_str = check_rtu_id(turbine, self.turbines, num_turbines)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(turbine, self.turbines, num_turbines)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.turbines, turbine)
|
||||
@ -463,7 +463,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
|
||||
---@param boiler unit_session
|
||||
---@return boolean linked boiler accepted to associated device slot
|
||||
function public.add_boiler(boiler)
|
||||
local fail_code, fail_str = check_rtu_id(boiler, self.boilers, num_boilers)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(boiler, self.boilers, num_boilers)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.boilers, boiler)
|
||||
@ -484,7 +484,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
|
||||
---@param dynamic_tank unit_session
|
||||
---@return boolean linked dynamic tank accepted (max 1)
|
||||
function public.add_tank(dynamic_tank)
|
||||
local fail_code, fail_str = check_rtu_id(dynamic_tank, self.tanks, 1)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(dynamic_tank, self.tanks, 1)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.tanks, dynamic_tank)
|
||||
@ -503,7 +503,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
|
||||
---@param envd unit_session
|
||||
---@return boolean linked environment detector accepted (max 1)
|
||||
function public.add_envd(envd)
|
||||
local fail_code, fail_str = check_rtu_id(envd, self.envd, 99)
|
||||
local fail_code, fail_str = svsessions.check_rtu_id(envd, self.envd, 99)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.envd, envd)
|
||||
|
Loading…
Reference in New Issue
Block a user