local log = require("scada-common.log") local types = require("scada-common.types") local util = require("scada-common.util") local unit_session = require("supervisor.session.rtu.unit_session") local imatrix = {} local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE local MODBUS_FCODE = types.MODBUS_FCODE local TXN_TYPES = { FORMED = 1, BUILD = 2, STATE = 3, TANKS = 4 } local TXN_TAGS = { "imatrix.formed", "imatrix.build", "imatrix.state", "imatrix.tanks" } local PERIODICS = { FORMED = 2000, BUILD = 1000, STATE = 500, TANKS = 1000 } -- create a new imatrix rtu session runner ---@nodiscard ---@param session_id integer RTU gateway session ID ---@param unit_id integer RTU ID ---@param advert rtu_advertisement RTU advertisement table ---@param out_queue mqueue RTU message out queue function imatrix.new(session_id, unit_id, advert, out_queue) -- checks if advert.type ~= RTU_UNIT_TYPE.IMATRIX then log.error("attempt to instantiate imatrix RTU for type " .. types.rtu_type_to_string(advert.type)) return nil end local log_tag = util.c("session.rtu(", session_id, ").imatrix[@", unit_id, "]: ") local self = { session = unit_session.new(session_id, unit_id, advert, out_queue, log_tag, TXN_TAGS), has_build = false, periodics = { next_formed_req = 0, next_build_req = 0, next_state_req = 0, next_tanks_req = 0 }, ---@class imatrix_session_db db = { formed = false, build = { last_update = 0, length = 0, width = 0, height = 0, min_pos = types.new_zero_coordinate(), max_pos = types.new_zero_coordinate(), max_energy = 0, transfer_cap = 0, cells = 0, providers = 0 }, state = { last_update = 0, last_input = 0, last_output = 0 }, tanks = { last_update = 0, energy = 0, energy_need = 0, energy_fill = 0.0 } } } local public = self.session.get() -- PRIVATE FUNCTIONS -- -- query if the multiblock is formed local function _request_formed() -- read discrete input 1 (start = 1, count = 1) self.session.send_request(TXN_TYPES.FORMED, MODBUS_FCODE.READ_DISCRETE_INPUTS, { 1, 1 }) end -- query the build of the device local function _request_build() -- read input registers 1 through 9 (start = 1, count = 9) self.session.send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 9 }) end -- query the state of the device local function _request_state() -- read input register 10 through 11 (start = 10, count = 2) self.session.send_request(TXN_TYPES.STATE, MODBUS_FCODE.READ_INPUT_REGS, { 10, 2 }) end -- query the tanks of the device local function _request_tanks() -- read input registers 12 through 15 (start = 12, count = 3) self.session.send_request(TXN_TYPES.TANKS, MODBUS_FCODE.READ_INPUT_REGS, { 12, 3 }) end -- PUBLIC FUNCTIONS -- -- handle a packet ---@param m_pkt modbus_frame function public.handle_packet(m_pkt) local txn_type = self.session.try_resolve(m_pkt) if txn_type == false then -- nothing to do elseif txn_type == TXN_TYPES.FORMED then -- formed response -- load in data if correct length if m_pkt.length == 1 then self.db.formed = m_pkt.data[1] if not self.db.formed then self.has_build = false end else log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")") end elseif txn_type == TXN_TYPES.BUILD then -- build response -- load in data if correct length if m_pkt.length == 9 then self.db.build.last_update = util.time_ms() self.db.build.length = m_pkt.data[1] self.db.build.width = m_pkt.data[2] self.db.build.height = m_pkt.data[3] self.db.build.min_pos = m_pkt.data[4] self.db.build.max_pos = m_pkt.data[5] self.db.build.max_energy = m_pkt.data[6] self.db.build.transfer_cap = m_pkt.data[7] self.db.build.cells = m_pkt.data[8] self.db.build.providers = m_pkt.data[9] self.has_build = true out_queue.push_data(unit_session.RTU_US_DATA.BUILD_CHANGED, { unit = advert.reactor, type = advert.type }) else log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")") end elseif txn_type == TXN_TYPES.STATE then -- state response -- load in data if correct length if m_pkt.length == 2 then self.db.state.last_update = util.time_ms() self.db.state.last_input = m_pkt.data[1] self.db.state.last_output = m_pkt.data[2] else log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")") end elseif txn_type == TXN_TYPES.TANKS then -- tanks response -- load in data if correct length if m_pkt.length == 3 then self.db.tanks.last_update = util.time_ms() self.db.tanks.energy = m_pkt.data[1] self.db.tanks.energy_need = m_pkt.data[2] self.db.tanks.energy_fill = m_pkt.data[3] else log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")") end elseif txn_type == nil then log.error(log_tag .. "unknown transaction reply") else log.error(log_tag .. "unknown transaction type " .. txn_type) end end -- update this runner ---@param time_now integer milliseconds function public.update(time_now) if self.periodics.next_formed_req <= time_now then _request_formed() self.periodics.next_formed_req = time_now + PERIODICS.FORMED end if self.db.formed then if not self.has_build and self.periodics.next_build_req <= time_now then _request_build() self.periodics.next_build_req = time_now + PERIODICS.BUILD end if self.periodics.next_state_req <= time_now then _request_state() self.periodics.next_state_req = time_now + PERIODICS.STATE end if self.periodics.next_tanks_req <= time_now then _request_tanks() self.periodics.next_tanks_req = time_now + PERIODICS.TANKS end end self.session.post_update() end -- invalidate build cache function public.invalidate_cache() self.periodics.next_formed_req = 0 self.periodics.next_build_req = 0 self.has_build = false end -- get the unit session database ---@nodiscard function public.get_db() return self.db end return public end return imatrix