-- -- I/O Control for Supervisor/Coordinator Integration -- local log = require("scada-common.log") local psil = require("scada-common.psil") local types = require("scada-common.types") local util = require("scada-common.util") local process = require("coordinator.process") local sounder = require("coordinator.sounder") local pgi = require("coordinator.ui.pgi") local ALARM_STATE = types.ALARM_STATE local PROCESS = types.PROCESS local TEMP_SCALE = types.TEMP_SCALE local TEMP_UNITS = types.TEMP_SCALE_UNITS -- nominal RTT is ping (0ms to 10ms usually) + 500ms for CRD main loop tick local WARN_RTT = 1000 -- 2x as long as expected w/ 0 ping local HIGH_RTT = 1500 -- 3.33x as long as expected w/ 0 ping local iocontrol = {} ---@class ioctl local io = {} -- luacheck: no unused args -- placeholder acknowledge function for type hinting ---@param success boolean ---@diagnostic disable-next-line: unused-local local function __generic_ack(success) end -- luacheck: unused args -- initialize front panel PSIL ---@param firmware_v string coordinator version ---@param comms_v string comms version function iocontrol.init_fp(firmware_v, comms_v) ---@class ioctl_front_panel io.fp = { ps = psil.create() } io.fp.ps.publish("version", firmware_v) io.fp.ps.publish("comms_version", comms_v) end -- initialize the coordinator IO controller ---@param conf facility_conf configuration ---@param comms coord_comms comms reference ---@param temp_scale TEMP_SCALE temperature unit function iocontrol.init(conf, comms, temp_scale) io.temp_label = TEMP_UNITS[temp_scale] -- temperature unit label and conversion function (from Kelvin) if temp_scale == TEMP_SCALE.CELSIUS then io.temp_convert = function (t) return t - 273.15 end elseif temp_scale == TEMP_SCALE.FAHRENHEIT then io.temp_convert = function (t) return (1.8 * (t - 273.15)) + 32 end elseif temp_scale == TEMP_SCALE.RANKINE then io.temp_convert = function (t) return 1.8 * t end else io.temp_label = "K" io.temp_convert = function (t) return t end end -- facility data structure ---@class ioctl_facility io.facility = { conf = conf, num_units = conf.num_units, tank_mode = conf.cooling.fac_tank_mode, tank_defs = conf.cooling.fac_tank_defs, all_sys_ok = false, rtu_count = 0, auto_ready = false, auto_active = false, auto_ramping = false, auto_saturated = false, auto_scram = false, ---@type ascram_status ascram_status = { matrix_dc = false, matrix_fill = false, crit_alarm = false, radiation = false, gen_fault = false }, ---@type WASTE_PRODUCT auto_current_waste_product = types.WASTE_PRODUCT.PLUTONIUM, auto_pu_fallback_active = false, auto_sps_disabled = false, radiation = types.new_zero_radiation_reading(), save_cfg_ack = __generic_ack, start_ack = __generic_ack, stop_ack = __generic_ack, scram_ack = __generic_ack, ack_alarms_ack = __generic_ack, alarm_tones = { false, false, false, false, false, false, false, false }, ps = psil.create(), induction_ps_tbl = {}, induction_data_tbl = {}, sps_ps_tbl = {}, sps_data_tbl = {}, tank_ps_tbl = {}, tank_data_tbl = {}, env_d_ps = psil.create(), env_d_data = {} } -- create induction and SPS tables (currently only 1 of each is supported) table.insert(io.facility.induction_ps_tbl, psil.create()) table.insert(io.facility.induction_data_tbl, {}) table.insert(io.facility.sps_ps_tbl, psil.create()) table.insert(io.facility.sps_data_tbl, {}) -- determine tank information if io.facility.tank_mode == 0 then io.facility.tank_defs = {} -- on facility tank mode 0, setup tank defs to match unit tank option for i = 1, conf.num_units do io.facility.tank_defs[i] = util.trinary(conf.cooling.r_cool[i].TankConnection, 1, 0) end io.facility.tank_list = { table.unpack(io.facility.tank_defs) } else -- decode the layout of tanks from the connections definitions local tank_mode = io.facility.tank_mode local tank_defs = io.facility.tank_defs local tank_list = { table.unpack(tank_defs) } local function calc_fdef(start_idx, end_idx) local first = 4 for i = start_idx, end_idx do if io.facility.tank_defs[i] == 2 then if i < first then first = i end end end return first end if tank_mode == 1 then -- (1) 1 total facility tank (A A A A) local first_fdef = calc_fdef(1, #tank_defs) for i = 1, #tank_defs do if i > first_fdef and tank_defs[i] == 2 then tank_list[i] = 0 end end elseif tank_mode == 2 then -- (2) 2 total facility tanks (A A A B) local first_fdef = calc_fdef(1, math.min(3, #tank_defs)) for i = 1, #tank_defs do if (i ~= 4) and (i > first_fdef) and (tank_defs[i] == 2) then tank_list[i] = 0 end end elseif tank_mode == 3 then -- (3) 2 total facility tanks (A A B B) for _, a in pairs({ 1, 3 }) do local b = a + 1 if (tank_defs[a] == 2) and (tank_defs[b] == 2) then tank_list[b] = 0 end end elseif tank_mode == 4 then -- (4) 2 total facility tanks (A B B B) local first_fdef = calc_fdef(2, #tank_defs) for i = 1, #tank_defs do if (i ~= 1) and (i > first_fdef) and (tank_defs[i] == 2) then tank_list[i] = 0 end end elseif tank_mode == 5 then -- (5) 3 total facility tanks (A A B C) local first_fdef = calc_fdef(1, math.min(2, #tank_defs)) for i = 1, #tank_defs do if (not (i == 3 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then tank_list[i] = 0 end end elseif tank_mode == 6 then -- (6) 3 total facility tanks (A B B C) local first_fdef = calc_fdef(2, math.min(3, #tank_defs)) for i = 1, #tank_defs do if (not (i == 1 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then tank_list[i] = 0 end end elseif tank_mode == 7 then -- (7) 3 total facility tanks (A B C C) local first_fdef = calc_fdef(3, #tank_defs) for i = 1, #tank_defs do if (not (i == 1 or i == 2)) and (i > first_fdef) and (tank_defs[i] == 2) then tank_list[i] = 0 end end end io.facility.tank_list = tank_list end -- create facility tank tables for i = 1, #io.facility.tank_list do if io.facility.tank_list[i] == 2 then table.insert(io.facility.tank_ps_tbl, psil.create()) table.insert(io.facility.tank_data_tbl, {}) end end -- create unit data structures io.units = {} for i = 1, conf.num_units do local function ack(alarm) process.ack_alarm(i, alarm) end local function reset(alarm) process.reset_alarm(i, alarm) end ---@class ioctl_unit local entry = { unit_id = i, connected = false, rtu_hw = { boilers = {}, turbines = {} }, num_boilers = 0, num_turbines = 0, num_snas = 0, has_tank = conf.cooling.r_cool[i].TankConnection, control_state = false, burn_rate_cmd = 0.0, radiation = types.new_zero_radiation_reading(), sna_peak_rate = 0.0, sna_max_rate = 0.0, sna_out_rate = 0.0, waste_mode = types.WASTE_MODE.MANUAL_PLUTONIUM, waste_product = types.WASTE_PRODUCT.PLUTONIUM, last_rate_change_ms = 0, turbine_flow_stable = false, -- auto control group a_group = 0, start = function () process.start(i) end, scram = function () process.scram(i) end, reset_rps = function () process.reset_rps(i) end, ack_alarms = function () process.ack_all_alarms(i) end, set_burn = function (rate) process.set_rate(i, rate) end, ---@param rate number burn rate set_waste = function (mode) process.set_unit_waste(i, mode) end, ---@param mode WASTE_MODE waste processing mode set_group = function (grp) process.set_group(i, grp) end, ---@param grp integer|0 group ID or 0 for manual start_ack = __generic_ack, scram_ack = __generic_ack, reset_rps_ack = __generic_ack, ack_alarms_ack = __generic_ack, set_burn_ack = __generic_ack, set_waste_ack = __generic_ack, alarm_callbacks = { c_breach = { ack = function () ack(1) end, reset = function () reset(1) end }, radiation = { ack = function () ack(2) end, reset = function () reset(2) end }, r_lost = { ack = function () ack(3) end, reset = function () reset(3) end }, dmg_crit = { ack = function () ack(4) end, reset = function () reset(4) end }, damage = { ack = function () ack(5) end, reset = function () reset(5) end }, over_temp = { ack = function () ack(6) end, reset = function () reset(6) end }, high_temp = { ack = function () ack(7) end, reset = function () reset(7) end }, waste_leak = { ack = function () ack(8) end, reset = function () reset(8) end }, waste_high = { ack = function () ack(9) end, reset = function () reset(9) end }, rps_trans = { ack = function () ack(10) end, reset = function () reset(10) end }, rcs_trans = { ack = function () ack(11) end, reset = function () reset(11) end }, t_trip = { ack = function () ack(12) end, reset = function () reset(12) end } }, ---@type alarms alarms = { ALARM_STATE.INACTIVE, -- containment breach ALARM_STATE.INACTIVE, -- containment radiation ALARM_STATE.INACTIVE, -- reactor lost ALARM_STATE.INACTIVE, -- damage critical ALARM_STATE.INACTIVE, -- reactor taking damage ALARM_STATE.INACTIVE, -- reactor over temperature ALARM_STATE.INACTIVE, -- reactor high temperature ALARM_STATE.INACTIVE, -- waste leak ALARM_STATE.INACTIVE, -- waste level high ALARM_STATE.INACTIVE, -- RPS transient ALARM_STATE.INACTIVE, -- RCS transient ALARM_STATE.INACTIVE -- turbine trip }, annunciator = {}, ---@type annunciator unit_ps = psil.create(), reactor_data = {}, ---@type reactor_db boiler_ps_tbl = {}, boiler_data_tbl = {}, turbine_ps_tbl = {}, turbine_data_tbl = {}, tank_ps_tbl = {}, tank_data_tbl = {} } -- on other facility modes, overwrite unit TANK option with facility tank defs if io.facility.tank_mode ~= 0 then entry.has_tank = conf.cooling.fac_tank_defs[i] > 0 end -- create boiler tables for _ = 1, conf.cooling.r_cool[i].BoilerCount do table.insert(entry.boiler_ps_tbl, psil.create()) table.insert(entry.boiler_data_tbl, {}) table.insert(entry.rtu_hw.boilers, { connected = false, faulted = false }) end -- create turbine tables for _ = 1, conf.cooling.r_cool[i].TurbineCount do table.insert(entry.turbine_ps_tbl, psil.create()) table.insert(entry.turbine_data_tbl, {}) table.insert(entry.rtu_hw.turbines, { connected = false, faulted = false }) end -- create tank tables if io.facility.tank_defs[i] == 1 then table.insert(entry.tank_ps_tbl, psil.create()) table.insert(entry.tank_data_tbl, {}) end entry.num_boilers = #entry.boiler_data_tbl entry.num_turbines = #entry.turbine_data_tbl table.insert(io.units, entry) end -- pass IO control here since it can't be require'd due to a require loop process.init(io, comms) end --#region Front Panel PSIL -- toggle heartbeat indicator function iocontrol.heartbeat() io.fp.ps.toggle("heartbeat") end -- report presence of the wireless modem ---@param has_modem boolean function iocontrol.fp_has_modem(has_modem) io.fp.ps.publish("has_modem", has_modem) end -- report presence of the speaker ---@param has_speaker boolean function iocontrol.fp_has_speaker(has_speaker) io.fp.ps.publish("has_speaker", has_speaker) end -- report supervisor link state ---@param state integer function iocontrol.fp_link_state(state) io.fp.ps.publish("link_state", state) end -- report monitor connection state ---@param id string|integer unit ID for unit monitor, "main" for main monitor, or "flow" for flow monitor function iocontrol.fp_monitor_state(id, connected) local name = nil if id == "main" then name = "main_monitor" elseif id == "flow" then name = "flow_monitor" elseif type(id) == "number" then name = "unit_monitor_" .. id end if name ~= nil then io.fp.ps.publish(name, connected) end end -- report thread (routine) statuses ---@param thread string thread name ---@param ok boolean thread state function iocontrol.fp_rt_status(thread, ok) io.fp.ps.publish(util.c("routine__", thread), ok) end -- report PKT firmware version and PKT session connection state ---@param session_id integer PKT session ---@param fw string firmware version ---@param s_addr integer PKT computer ID function iocontrol.fp_pkt_connected(session_id, fw, s_addr) io.fp.ps.publish("pkt_" .. session_id .. "_fw", fw) io.fp.ps.publish("pkt_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr)) pgi.create_pkt_entry(session_id) end -- report PKT session disconnected ---@param session_id integer PKT session function iocontrol.fp_pkt_disconnected(session_id) pgi.delete_pkt_entry(session_id) end -- transmit PKT session RTT ---@param session_id integer PKT session ---@param rtt integer round trip time function iocontrol.fp_pkt_rtt(session_id, rtt) io.fp.ps.publish("pkt_" .. session_id .. "_rtt", rtt) if rtt > HIGH_RTT then io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.red) elseif rtt > WARN_RTT then io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.yellow_hc) else io.fp.ps.publish("pkt_" .. session_id .. "_rtt_color", colors.green_hc) end end --#endregion --#region Builds -- record and publish multiblock RTU build data ---@param id integer ---@param entry table ---@param data_tbl table ---@param ps_tbl table ---@param create boolean? true to create an entry if non exists, false to fail on missing ---@return boolean ok true if data saved, false if invalid ID local function _record_multiblock_build(id, entry, data_tbl, ps_tbl, create) local exists = type(data_tbl[id]) == "table" if exists or create then if not exists then ps_tbl[id] = psil.create() data_tbl[id] = {} end data_tbl[id].formed = entry[1] ---@type boolean data_tbl[id].build = entry[2] ---@type table ps_tbl[id].publish("formed", entry[1]) for key, val in pairs(data_tbl[id].build) do ps_tbl[id].publish(key, val) end end return exists or (create == true) end -- populate facility structure builds ---@param build table ---@return boolean valid function iocontrol.record_facility_builds(build) local valid = true if type(build) == "table" then local fac = io.facility -- induction matricies if type(build.induction) == "table" then for id, matrix in pairs(build.induction) do if not _record_multiblock_build(id, matrix, fac.induction_data_tbl, fac.induction_ps_tbl) then log.debug(util.c("iocontrol.record_facility_builds: invalid induction matrix id ", id)) valid = false end end end -- SPS if type(build.sps) == "table" then for id, sps in pairs(build.sps) do if not _record_multiblock_build(id, sps, fac.sps_data_tbl, fac.sps_ps_tbl) then log.debug(util.c("iocontrol.record_facility_builds: invalid SPS id ", id)) valid = false end end end -- dynamic tanks if type(build.tanks) == "table" then for id, tank in pairs(build.tanks) do _record_multiblock_build(id, tank, fac.tank_data_tbl, fac.tank_ps_tbl, true) end end else log.debug("facility builds not a table") valid = false end return valid end -- populate unit structure builds ---@param builds table ---@return boolean valid function iocontrol.record_unit_builds(builds) local valid = true -- note: if not all units and RTUs are connected, some will be nil for id, build in pairs(builds) do local unit = io.units[id] ---@type ioctl_unit local log_header = util.c("iocontrol.record_unit_builds[UNIT ", id, "]: ") if type(build) ~= "table" then log.debug(log_header .. "build not a table") valid = false elseif type(unit) ~= "table" then log.debug(log_header .. "invalid unit id") valid = false else -- reactor build if type(build.reactor) == "table" then unit.reactor_data.mek_struct = build.reactor ---@type mek_struct for key, val in pairs(unit.reactor_data.mek_struct) do unit.unit_ps.publish(key, val) end if (type(unit.reactor_data.mek_struct.length) == "number") and (unit.reactor_data.mek_struct.length ~= 0) and (type(unit.reactor_data.mek_struct.width) == "number") and (unit.reactor_data.mek_struct.width ~= 0) then unit.unit_ps.publish("size", { unit.reactor_data.mek_struct.length, unit.reactor_data.mek_struct.width }) end end -- boiler builds if type(build.boilers) == "table" then for b_id, boiler in pairs(build.boilers) do if not _record_multiblock_build(b_id, boiler, unit.boiler_data_tbl, unit.boiler_ps_tbl) then log.debug(util.c(log_header, "invalid boiler id ", b_id)) valid = false end end end -- turbine builds if type(build.turbines) == "table" then for t_id, turbine in pairs(build.turbines) do if not _record_multiblock_build(t_id, turbine, unit.turbine_data_tbl, unit.turbine_ps_tbl) then log.debug(util.c(log_header, "invalid turbine id ", t_id)) valid = false end end end -- dynamic tank builds if type(build.tanks) == "table" then for d_id, d_tank in pairs(build.tanks) do _record_multiblock_build(d_id, d_tank, unit.tank_data_tbl, unit.tank_ps_tbl, true) end end end end return valid end --#endregion --#region Statuses -- record and publish multiblock status data ---@param entry any ---@param data imatrix_session_db|sps_session_db|dynamicv_session_db|turbinev_session_db|boilerv_session_db ---@param ps psil ---@return boolean is_faulted local function _record_multiblock_status(entry, data, ps) local is_faulted = entry[1] ---@type boolean data.formed = entry[2] ---@type boolean data.state = entry[3] ---@type table data.tanks = entry[4] ---@type table ps.publish("formed", data.formed) ps.publish("faulted", is_faulted) for key, val in pairs(data.state) do ps.publish(key, val) end for key, val in pairs(data.tanks) do ps.publish(key, val) end return is_faulted end -- update facility status ---@param status table ---@return boolean valid function iocontrol.update_facility_status(status) local valid = true local log_header = util.c("iocontrol.update_facility_status: ") if type(status) ~= "table" then log.debug(util.c(log_header, "status not a table")) valid = false else local fac = io.facility -- auto control status information local ctl_status = status[1] if type(ctl_status) == "table" and #ctl_status == 17 then fac.all_sys_ok = ctl_status[1] fac.auto_ready = ctl_status[2] if type(ctl_status[3]) == "number" then fac.auto_active = ctl_status[3] > PROCESS.INACTIVE else fac.auto_active = false valid = false end fac.auto_ramping = ctl_status[4] fac.auto_saturated = ctl_status[5] fac.auto_scram = ctl_status[6] fac.ascram_status.matrix_dc = ctl_status[7] fac.ascram_status.matrix_fill = ctl_status[8] fac.ascram_status.crit_alarm = ctl_status[9] fac.ascram_status.radiation = ctl_status[10] fac.ascram_status.gen_fault = ctl_status[11] fac.status_line_1 = ctl_status[12] fac.status_line_2 = ctl_status[13] fac.ps.publish("all_sys_ok", fac.all_sys_ok) fac.ps.publish("auto_ready", fac.auto_ready) fac.ps.publish("auto_active", fac.auto_active) fac.ps.publish("auto_ramping", fac.auto_ramping) fac.ps.publish("auto_saturated", fac.auto_saturated) fac.ps.publish("auto_scram", fac.auto_scram) fac.ps.publish("as_matrix_dc", fac.ascram_status.matrix_dc) fac.ps.publish("as_matrix_fill", fac.ascram_status.matrix_fill) fac.ps.publish("as_crit_alarm", fac.ascram_status.crit_alarm) fac.ps.publish("as_radiation", fac.ascram_status.radiation) fac.ps.publish("as_gen_fault", fac.ascram_status.gen_fault) fac.ps.publish("status_line_1", fac.status_line_1) fac.ps.publish("status_line_2", fac.status_line_2) local group_map = ctl_status[14] if (type(group_map) == "table") and (#group_map == fac.num_units) then local names = { "Manual", "Primary", "Secondary", "Tertiary", "Backup" } for i = 1, #group_map do io.units[i].a_group = group_map[i] io.units[i].unit_ps.publish("auto_group_id", group_map[i]) io.units[i].unit_ps.publish("auto_group", names[group_map[i] + 1]) end end fac.auto_current_waste_product = ctl_status[15] fac.auto_pu_fallback_active = ctl_status[16] fac.auto_sps_disabled = ctl_status[17] fac.ps.publish("current_waste_product", fac.auto_current_waste_product) fac.ps.publish("pu_fallback_active", fac.auto_pu_fallback_active) fac.ps.publish("sps_disabled_low_power", fac.auto_sps_disabled) else log.debug(log_header .. "control status not a table or length mismatch") valid = false end -- RTU statuses local rtu_statuses = status[2] fac.rtu_count = 0 if type(rtu_statuses) == "table" then -- connected RTU count fac.rtu_count = rtu_statuses.count -- power statistics if type(rtu_statuses.power) == "table" and #rtu_statuses.power == 4 then local data = fac.induction_data_tbl[1] ---@type imatrix_session_db local ps = fac.induction_ps_tbl[1] ---@type psil local chg = tonumber(rtu_statuses.power[1]) local in_f = tonumber(rtu_statuses.power[2]) local out_f = tonumber(rtu_statuses.power[3]) local eta = tonumber(rtu_statuses.power[4]) ps.publish("avg_charge", chg) ps.publish("avg_inflow", in_f) ps.publish("avg_outflow", out_f) ps.publish("eta_ms", eta) ps.publish("is_charging", in_f > out_f) ps.publish("is_discharging", out_f > in_f) if data and data.build then local cap = util.joules_to_fe(data.build.transfer_cap) ps.publish("at_max_io", in_f >= cap or out_f >= cap) end else log.debug(log_header .. "power statistics list not a table") valid = false end -- induction matricies statuses if type(rtu_statuses.induction) == "table" then for id = 1, #fac.induction_ps_tbl do if rtu_statuses.induction[id] == nil then -- disconnected fac.induction_ps_tbl[id].publish("computed_status", 1) end end for id, matrix in pairs(rtu_statuses.induction) do if type(fac.induction_data_tbl[id]) == "table" then local data = fac.induction_data_tbl[id] ---@type imatrix_session_db local ps = fac.induction_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(matrix, data, ps) if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then if data.tanks.energy_fill >= 0.99 then ps.publish("computed_status", 6) -- full elseif data.tanks.energy_fill <= 0.01 then ps.publish("computed_status", 5) -- empty else ps.publish("computed_status", 4) -- on-line end else ps.publish("computed_status", 2) -- not formed end else log.debug(util.c(log_header, "invalid induction matrix id ", id)) end end else log.debug(log_header .. "induction matrix list not a table") valid = false end -- SPS statuses if type(rtu_statuses.sps) == "table" then for id = 1, #fac.sps_ps_tbl do if rtu_statuses.sps[id] == nil then -- disconnected fac.sps_ps_tbl[id].publish("computed_status", 1) end end for id, sps in pairs(rtu_statuses.sps) do if type(fac.sps_data_tbl[id]) == "table" then local data = fac.sps_data_tbl[id] ---@type sps_session_db local ps = fac.sps_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(sps, data, ps) if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then if data.state.process_rate > 0 then ps.publish("computed_status", 5) -- active else ps.publish("computed_status", 4) -- idle end else ps.publish("computed_status", 2) -- not formed end io.facility.ps.publish("am_rate", data.state.process_rate * 1000) else log.debug(util.c(log_header, "invalid sps id ", id)) end end else log.debug(log_header .. "sps list not a table") valid = false end -- dynamic tank statuses if type(rtu_statuses.tanks) == "table" then for id = 1, #fac.tank_ps_tbl do if rtu_statuses.tanks[id] == nil then -- disconnected fac.tank_ps_tbl[id].publish("computed_status", 1) end end for id, tank in pairs(rtu_statuses.tanks) do if type(fac.tank_data_tbl[id]) == "table" then local data = fac.tank_data_tbl[id] ---@type dynamicv_session_db local ps = fac.tank_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(tank, data, ps) if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then if data.tanks.fill >= 0.99 then ps.publish("computed_status", 6) -- full elseif data.tanks.fill < 0.20 then ps.publish("computed_status", 5) -- low else ps.publish("computed_status", 4) -- on-line end else ps.publish("computed_status", 2) -- not formed end else log.debug(util.c(log_header, "invalid dynamic tank id ", id)) end end else log.debug(log_header .. "dyanmic tank list not a table") valid = false end -- environment detector status if type(rtu_statuses.envds) == "table" then local max_rad, max_reading, any_conn, any_faulted = 0, types.new_zero_radiation_reading(), false, false for _, envd in pairs(rtu_statuses.envds) do local rtu_faulted = envd[1] ---@type boolean local radiation = envd[2] ---@type radiation_reading local rad_raw = envd[3] ---@type number any_conn = true any_faulted = any_faulted or rtu_faulted if rad_raw > max_rad then max_rad = rad_raw max_reading = radiation end end if any_conn then fac.radiation = max_reading fac.ps.publish("rad_computed_status", util.trinary(any_faulted, 2, 3)) else fac.radiation = types.new_zero_radiation_reading() fac.ps.publish("rad_computed_status", 1) end fac.ps.publish("radiation", fac.radiation) else log.debug(log_header .. "environment detector list not a table") valid = false end else log.debug(log_header .. "rtu statuses not a table") valid = false end fac.ps.publish("rtu_count", fac.rtu_count) -- alarm tone commands if (type(status[3]) == "table") and (#status[3] == 8) then fac.alarm_tones = status[3] sounder.set(fac.alarm_tones) else log.debug(log_header .. "alarm tones not a table or length mismatch") valid = false end end return valid end -- update unit statuses ---@param statuses table ---@return boolean valid function iocontrol.update_unit_statuses(statuses) local valid = true if type(statuses) ~= "table" then log.debug("iocontrol.update_unit_statuses: unit statuses not a table") valid = false elseif #statuses ~= #io.units then log.debug("iocontrol.update_unit_statuses: number of provided unit statuses does not match expected number of units") valid = false else local burn_rate_sum = 0.0 local sna_count_sum = 0 local pu_rate, po_rate, po_pl_rate, po_am_rate, spent_rate = 0.0, 0.0, 0.0, 0.0, 0.0 -- get all unit statuses for i = 1, #statuses do local log_header = util.c("iocontrol.update_unit_statuses[unit ", i, "]: ") local unit = io.units[i] ---@type ioctl_unit local status = statuses[i] local burn_rate = 0.0 if type(status) ~= "table" or #status ~= 6 then log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)") valid = false else -- reactor PLC status local reactor_status = status[1] if type(reactor_status) ~= "table" then reactor_status = {} log.debug(log_header .. "reactor status not a table") end if #reactor_status == 0 then unit.connected = false unit.unit_ps.publish("computed_status", 1) -- disconnected elseif #reactor_status == 3 then local mek_status = reactor_status[1] local rps_status = reactor_status[2] local gen_status = reactor_status[3] if #gen_status == 6 then unit.reactor_data.last_status_update = gen_status[1] unit.reactor_data.control_state = gen_status[2] unit.reactor_data.rps_tripped = gen_status[3] unit.reactor_data.rps_trip_cause = gen_status[4] unit.reactor_data.no_reactor = gen_status[5] unit.reactor_data.formed = gen_status[6] else log.debug(log_header .. "reactor general status length mismatch") end unit.reactor_data.rps_status = rps_status ---@type rps_status unit.reactor_data.mek_status = mek_status ---@type mek_status -- if status hasn't been received, mek_status = {} if type(unit.reactor_data.mek_status.act_burn_rate) == "number" then burn_rate = unit.reactor_data.mek_status.act_burn_rate burn_rate_sum = burn_rate_sum + burn_rate end if unit.reactor_data.mek_status.status then unit.unit_ps.publish("computed_status", 5) -- running else if unit.reactor_data.no_reactor then unit.unit_ps.publish("computed_status", 3) -- faulted elseif not unit.reactor_data.formed then unit.unit_ps.publish("computed_status", 2) -- multiblock not formed elseif unit.reactor_data.rps_status.force_dis then unit.unit_ps.publish("computed_status", 7) -- reactor force disabled elseif unit.reactor_data.rps_tripped and unit.reactor_data.rps_trip_cause ~= "manual" then unit.unit_ps.publish("computed_status", 6) -- SCRAM else unit.unit_ps.publish("computed_status", 4) -- disabled end end for key, val in pairs(unit.reactor_data) do if key ~= "rps_status" and key ~= "mek_struct" and key ~= "mek_status" then unit.unit_ps.publish(key, val) end end if type(unit.reactor_data.rps_status) == "table" then for key, val in pairs(unit.reactor_data.rps_status) do unit.unit_ps.publish(key, val) end end if type(unit.reactor_data.mek_status) == "table" then for key, val in pairs(unit.reactor_data.mek_status) do unit.unit_ps.publish(key, val) end end unit.connected = true else log.debug(log_header .. "reactor status length mismatch") valid = false end -- RTU statuses local rtu_statuses = status[2] if type(rtu_statuses) == "table" then -- boiler statuses if type(rtu_statuses.boilers) == "table" then local boil_sum = 0 for id = 1, #unit.boiler_ps_tbl do local connected = rtu_statuses.boilers[id] ~= nil unit.rtu_hw.boilers[id].connected = connected if not connected then -- disconnected unit.boiler_ps_tbl[id].publish("computed_status", 1) end end for id, boiler in pairs(rtu_statuses.boilers) do if type(unit.boiler_data_tbl[id]) == "table" then local data = unit.boiler_data_tbl[id] ---@type boilerv_session_db local ps = unit.boiler_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(boiler, data, ps) unit.rtu_hw.boilers[id].faulted = rtu_faulted if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then boil_sum = boil_sum + data.state.boil_rate if data.state.boil_rate > 0 then ps.publish("computed_status", 5) -- active else ps.publish("computed_status", 4) -- idle end else ps.publish("computed_status", 2) -- not formed end else log.debug(util.c(log_header, "invalid boiler id ", id)) valid = false end end unit.unit_ps.publish("boiler_boil_sum", boil_sum) else log.debug(log_header .. "boiler list not a table") valid = false end -- turbine statuses if type(rtu_statuses.turbines) == "table" then local flow_sum = 0 for id = 1, #unit.turbine_ps_tbl do local connected = rtu_statuses.turbines[id] ~= nil unit.rtu_hw.turbines[id].connected = connected if not connected then -- disconnected unit.turbine_ps_tbl[id].publish("computed_status", 1) end end for id, turbine in pairs(rtu_statuses.turbines) do if type(unit.turbine_data_tbl[id]) == "table" then local data = unit.turbine_data_tbl[id] ---@type turbinev_session_db local ps = unit.turbine_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(turbine, data, ps) unit.rtu_hw.turbines[id].faulted = rtu_faulted if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then flow_sum = flow_sum + data.state.flow_rate if data.tanks.energy_fill >= 0.99 then ps.publish("computed_status", 6) -- trip elseif data.state.flow_rate < 100 then ps.publish("computed_status", 4) -- idle else ps.publish("computed_status", 5) -- active end else ps.publish("computed_status", 2) -- not formed end else log.debug(util.c(log_header, "invalid turbine id ", id)) valid = false end end unit.unit_ps.publish("turbine_flow_sum", flow_sum) else log.debug(log_header .. "turbine list not a table") valid = false end -- dynamic tank statuses if type(rtu_statuses.tanks) == "table" then for id = 1, #unit.tank_ps_tbl do if rtu_statuses.tanks[id] == nil then -- disconnected unit.tank_ps_tbl[id].publish("computed_status", 1) end end for id, tank in pairs(rtu_statuses.tanks) do if type(unit.tank_data_tbl[id]) == "table" then local data = unit.tank_data_tbl[id] ---@type dynamicv_session_db local ps = unit.tank_ps_tbl[id] ---@type psil local rtu_faulted = _record_multiblock_status(tank, data, ps) if rtu_faulted then ps.publish("computed_status", 3) -- faulted elseif data.formed then if data.tanks.fill >= 0.99 then ps.publish("computed_status", 6) -- full elseif data.tanks.fill < 0.20 then ps.publish("computed_status", 5) -- low else ps.publish("computed_status", 4) -- on-line end else ps.publish("computed_status", 2) -- not formed end else log.debug(util.c(log_header, "invalid dynamic tank id ", id)) valid = false end end else log.debug(log_header .. "dynamic tank list not a table") valid = false end -- solar neutron activator status info if type(rtu_statuses.sna) == "table" then unit.num_snas = rtu_statuses.sna[1] ---@type integer unit.sna_peak_rate = rtu_statuses.sna[2] ---@type number unit.sna_max_rate = rtu_statuses.sna[3] ---@type number unit.sna_out_rate = rtu_statuses.sna[4] ---@type number unit.unit_ps.publish("sna_count", unit.num_snas) unit.unit_ps.publish("sna_peak_rate", unit.sna_peak_rate) unit.unit_ps.publish("sna_max_rate", unit.sna_max_rate) unit.unit_ps.publish("sna_out_rate", unit.sna_out_rate) sna_count_sum = sna_count_sum + unit.num_snas else log.debug(log_header .. "sna statistic list not a table") valid = false end -- environment detector status if type(rtu_statuses.envds) == "table" then local max_rad, max_reading, any_conn = 0, types.new_zero_radiation_reading(), false for _, envd in pairs(rtu_statuses.envds) do local radiation = envd[2] ---@type radiation_reading local rad_raw = envd[3] ---@type number any_conn = true if rad_raw > max_rad then max_rad = rad_raw max_reading = radiation end end if any_conn then unit.radiation = max_reading else unit.radiation = types.new_zero_radiation_reading() end unit.unit_ps.publish("radiation", unit.radiation) else log.debug(log_header .. "radiation monitor list not a table") valid = false end else log.debug(log_header .. "rtu list not a table") valid = false end -- annunciator unit.annunciator = status[3] if type(unit.annunciator) ~= "table" then unit.annunciator = {} log.debug(log_header .. "annunciator state not a table") valid = false end for key, val in pairs(unit.annunciator) do if key == "BoilerOnline" or key == "HeatingRateLow" or key == "WaterLevelLow" then -- split up array for all boilers for id = 1, #val do unit.boiler_ps_tbl[id].publish(key, val[id]) end elseif key == "TurbineOnline" or key == "SteamDumpOpen" or key == "TurbineOverSpeed" or key == "GeneratorTrip" or key == "TurbineTrip" then -- split up array for all turbines for id = 1, #val do unit.turbine_ps_tbl[id].publish(key, val[id]) end elseif type(val) == "table" then -- we missed one of the tables? log.debug(log_header .. "unrecognized table found in annunciator list, this is a bug") valid = false else -- non-table fields unit.unit_ps.publish(key, val) end end -- alarms local alarm_states = status[4] if type(alarm_states) == "table" then for id = 1, #alarm_states do local state = alarm_states[id] unit.alarms[id] = state if state == types.ALARM_STATE.TRIPPED or state == types.ALARM_STATE.ACKED then unit.unit_ps.publish("Alarm_" .. id, 2) elseif state == types.ALARM_STATE.RING_BACK then unit.unit_ps.publish("Alarm_" .. id, 3) else unit.unit_ps.publish("Alarm_" .. id, 1) end end else log.debug(log_header .. "alarm states not a table") valid = false end -- unit state fields local unit_state = status[5] if type(unit_state) == "table" then if #unit_state == 8 then unit.waste_mode = unit_state[5] unit.waste_product = unit_state[6] unit.last_rate_change_ms = unit_state[7] unit.turbine_flow_stable = unit_state[8] unit.unit_ps.publish("U_StatusLine1", unit_state[1]) unit.unit_ps.publish("U_StatusLine2", unit_state[2]) unit.unit_ps.publish("U_AutoReady", unit_state[3]) unit.unit_ps.publish("U_AutoDegraded", unit_state[4]) unit.unit_ps.publish("U_AutoWaste", unit.waste_mode == types.WASTE_MODE.AUTO) unit.unit_ps.publish("U_WasteMode", unit.waste_mode) unit.unit_ps.publish("U_WasteProduct", unit.waste_product) else log.debug(log_header .. "unit state length mismatch") valid = false end else log.debug(log_header .. "unit state not a table") valid = false end -- valve states local valve_states = status[6] if type(valve_states) == "table" then if #valve_states == 5 then unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0) unit.unit_ps.publish("V_pu_state", valve_states[1] == 2) unit.unit_ps.publish("V_po_conn", valve_states[2] > 0) unit.unit_ps.publish("V_po_state", valve_states[2] == 2) unit.unit_ps.publish("V_pl_conn", valve_states[3] > 0) unit.unit_ps.publish("V_pl_state", valve_states[3] == 2) unit.unit_ps.publish("V_am_conn", valve_states[4] > 0) unit.unit_ps.publish("V_am_state", valve_states[4] == 2) unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0) unit.unit_ps.publish("V_emc_state", valve_states[5] == 2) else log.debug(log_header .. "valve states length mismatch") valid = false end else log.debug(log_header .. "valve states not a table") valid = false end -- determine waste production for this unit, add to statistics local is_pu = unit.waste_product == types.WASTE_PRODUCT.PLUTONIUM local waste_rate = burn_rate / 10.0 local u_spent_rate = waste_rate local u_pu_rate = util.trinary(is_pu, waste_rate, 0.0) local u_po_rate = unit.sna_out_rate unit.unit_ps.publish("pu_rate", u_pu_rate) unit.unit_ps.publish("po_rate", u_po_rate) unit.unit_ps.publish("sna_in", util.trinary(is_pu, 0, burn_rate)) if unit.waste_product == types.WASTE_PRODUCT.POLONIUM then u_spent_rate = u_po_rate unit.unit_ps.publish("po_pl_rate", u_po_rate) unit.unit_ps.publish("po_am_rate", 0) po_pl_rate = po_pl_rate + u_po_rate elseif unit.waste_product == types.WASTE_PRODUCT.ANTI_MATTER then u_spent_rate = 0 unit.unit_ps.publish("po_pl_rate", 0) unit.unit_ps.publish("po_am_rate", u_po_rate) po_am_rate = po_am_rate + u_po_rate else unit.unit_ps.publish("po_pl_rate", 0) unit.unit_ps.publish("po_am_rate", 0) end unit.unit_ps.publish("ws_rate", u_spent_rate) pu_rate = pu_rate + u_pu_rate po_rate = po_rate + u_po_rate spent_rate = spent_rate + u_spent_rate end end io.facility.ps.publish("burn_sum", burn_rate_sum) io.facility.ps.publish("sna_count", sna_count_sum) io.facility.ps.publish("pu_rate", pu_rate) io.facility.ps.publish("po_rate", po_rate) io.facility.ps.publish("po_pl_rate", po_pl_rate) io.facility.ps.publish("po_am_rate", po_am_rate) io.facility.ps.publish("spent_waste_rate", spent_rate) end return valid end --#endregion -- get the IO controller database function iocontrol.get_db() return io end return iocontrol