-- -- Nuclear Generation Facility SCADA Supervisor -- require("/initenv").init_env() local crash = require("scada-common.crash") local comms = require("scada-common.comms") local log = require("scada-common.log") local network = require("scada-common.network") local ppm = require("scada-common.ppm") local tcd = require("scada-common.tcd") local util = require("scada-common.util") local core = require("graphics.core") local configure = require("supervisor.configure") local databus = require("supervisor.databus") local renderer = require("supervisor.renderer") local supervisor = require("supervisor.supervisor") local svsessions = require("supervisor.session.svsessions") local SUPERVISOR_VERSION = "v1.3.7" local println = util.println local println_ts = util.println_ts ---------------------------------------- -- get configuration ---------------------------------------- if not supervisor.load_config() then -- try to reconfigure (user action) local success, error = configure.configure(true) if success then if not supervisor.load_config() then println("failed to load a valid configuration, please reconfigure") return end else println("configuration error: " .. error) return end end local config = supervisor.config local cfv = util.new_validator() cfv.assert_eq(#config.CoolingConfig, config.UnitCount) assert(cfv.valid(), "startup> the number of reactor cooling configurations is different than the number of units") for i = 1, config.UnitCount do cfv.assert_type_table(config.CoolingConfig[i]) assert(cfv.valid(), "startup> missing cooling entry for reactor unit " .. i) cfv.assert_type_int(config.CoolingConfig[i].BoilerCount) cfv.assert_type_int(config.CoolingConfig[i].TurbineCount) cfv.assert_type_bool(config.CoolingConfig[i].TankConnection) assert(cfv.valid(), "startup> missing boiler/turbine/tank fields for reactor unit " .. i) cfv.assert_range(config.CoolingConfig[i].BoilerCount, 0, 2) cfv.assert_range(config.CoolingConfig[i].TurbineCount, 1, 3) assert(cfv.valid(), "startup> out-of-range number of boilers and/or turbines provided for reactor unit " .. i) end if config.FacilityTankMode > 0 then assert(config.UnitCount == #config.FacilityTankDefs, "startup> the number of facility tank definitions must be equal to the number of units in facility tank mode") for i = 1, config.UnitCount do local def = config.FacilityTankDefs[i] cfv.assert_type_int(def) cfv.assert_range(def, 0, 2) assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i) end end ---------------------------------------- -- log init ---------------------------------------- log.init(config.LogPath, config.LogMode, config.LogDebug) log.info("========================================") log.info("BOOTING supervisor.startup " .. SUPERVISOR_VERSION) log.info("========================================") println(">> SCADA Supervisor " .. SUPERVISOR_VERSION .. " <<") crash.set_env("supervisor", SUPERVISOR_VERSION) crash.dbg_log_env() ---------------------------------------- -- main application ---------------------------------------- local function main() ---------------------------------------- -- startup ---------------------------------------- -- record firmware versions and ID databus.tx_versions(SUPERVISOR_VERSION, comms.version) -- mount connected devices ppm.mount_all() -- message authentication init if type(config.AuthKey) == "string" and string.len(config.AuthKey) > 0 then network.init_mac(config.AuthKey) end -- get modem local modem = ppm.get_wireless_modem() if modem == nil then println("startup> wireless modem not found") log.fatal("no wireless modem on startup") return end databus.tx_hw_modem(true) -- start UI local fp_ok, message = renderer.try_start_ui(config.FrontPanelTheme, config.ColorMode) if not fp_ok then println_ts(util.c("UI error: ", message)) log.error(util.c("front panel GUI render failed with error ", message)) else -- redefine println_ts local to not print as we have the front panel running println_ts = function (_) end end -- create network interface then setup comms local nic = network.nic(modem) local superv_comms = supervisor.comms(SUPERVISOR_VERSION, nic, fp_ok) -- base loop clock (6.67Hz, 3 ticks) local MAIN_CLOCK = 0.15 local loop_clock = util.new_clock(MAIN_CLOCK) -- start clock loop_clock.start() -- halve the rate heartbeat LED flash local heartbeat_toggle = true -- event loop while true do local event, param1, param2, param3, param4, param5 = util.pull_event() -- handle event if event == "peripheral_detach" then local type, device = ppm.handle_unmount(param1) if type ~= nil and device ~= nil then if type == "modem" then -- we only care if this is our wireless modem if nic.is_modem(device) then nic.disconnect() println_ts("wireless modem disconnected!") log.warning("comms modem disconnected") local other_modem = ppm.get_wireless_modem() if other_modem then log.info("found another wireless modem, using it for comms") nic.connect(other_modem) else databus.tx_hw_modem(false) end else log.warning("non-comms modem disconnected") end end end elseif event == "peripheral" then local type, device = ppm.mount(param1) if type ~= nil and device ~= nil then if type == "modem" then if device.isWireless() and not nic.is_connected() then -- reconnected modem nic.connect(device) println_ts("wireless modem reconnected.") log.info("comms modem reconnected") databus.tx_hw_modem(true) elseif device.isWireless() then log.info("unused wireless modem reconnected") else log.info("wired modem reconnected") end end end elseif event == "timer" and loop_clock.is_clock(param1) then -- main loop tick if heartbeat_toggle then databus.heartbeat() end heartbeat_toggle = not heartbeat_toggle -- iterate sessions svsessions.iterate_all() -- free any closed sessions svsessions.free_all_closed() loop_clock.start() elseif event == "timer" then -- a non-clock timer event, check watchdogs svsessions.check_all_watchdogs(param1) -- notify timer callback dispatcher tcd.handle(param1) elseif event == "modem_message" then -- got a packet local packet = superv_comms.parse_packet(param1, param2, param3, param4, param5) superv_comms.handle_packet(packet) elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" or event == "double_click" then -- handle a mouse event renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3)) end -- check for termination request if event == "terminate" or ppm.should_terminate() then println_ts("closing sessions...") log.info("terminate requested, closing sessions...") svsessions.close_all() log.info("sessions closed") break end end renderer.close_ui() util.println_ts("exited") log.info("exited") end if not xpcall(main, crash.handler) then pcall(renderer.close_ui) crash.exit() else log.close() end