cc-mek-scada/coordinator/ui/layout/main_view.lua
Mikayla Fischler 98c37caecd #460 cleanup
2024-04-08 23:59:16 -04:00

94 lines
3.1 KiB
Lua

--
-- Main SCADA Coordinator GUI
--
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
local style = require("coordinator.ui.style")
local imatrix = require("coordinator.ui.components.imatrix")
local process_ctl = require("coordinator.ui.components.process_ctl")
local unit_overview = require("coordinator.ui.components.unit_overview")
local core = require("graphics.core")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local ALIGN = core.ALIGN
-- create new main view
---@param main graphics_element main displaybox
local function init(main)
local s_header = style.theme.header
local facility = iocontrol.get_db().facility
local units = iocontrol.get_db().units
-- window header message
local header = TextBox{parent=main,y=1,text="Nuclear Generation Facility SCADA Coordinator",alignment=ALIGN.CENTER,height=1,fg_bg=s_header}
local ping = DataIndicator{parent=main,x=1,y=1,label="SVTT",format="%d",value=0,unit="ms",lu_colors=style.lg_white,width=12,fg_bg=s_header}
-- max length example: "01:23:45 AM - Wednesday, September 28 2022"
local datetime = TextBox{parent=main,x=(header.get_width()-42),y=1,text="",alignment=ALIGN.RIGHT,width=42,height=1,fg_bg=s_header}
ping.register(facility.ps, "sv_ping", ping.update)
datetime.register(facility.ps, "date_time", datetime.set_value)
local uo_1, uo_2, uo_3, uo_4 ---@type graphics_element
local cnc_y_start = 3
local row_1_height = 0
-- unit overviews
if facility.num_units >= 1 then
uo_1 = unit_overview(main, 2, 3, units[1])
row_1_height = uo_1.get_height()
end
if facility.num_units >= 2 then
uo_2 = unit_overview(main, 84, 3, units[2])
row_1_height = math.max(row_1_height, uo_2.get_height())
end
cnc_y_start = cnc_y_start + row_1_height + 1
util.nop()
if facility.num_units >= 3 then
-- base offset 3, spacing 1, max height of units 1 and 2
local row_2_offset = cnc_y_start
uo_3 = unit_overview(main, 2, row_2_offset, units[3])
cnc_y_start = row_2_offset + uo_3.get_height() + 1
if facility.num_units == 4 then
uo_4 = unit_overview(main, 84, row_2_offset, units[4])
cnc_y_start = math.max(cnc_y_start, row_2_offset + uo_4.get_height() + 1)
end
util.nop()
end
-- command & control
-- induction matrix and process control interfaces are 24 tall + space needed for divider
local cnc_bottom_align_start = main.get_height() - 26
assert(cnc_bottom_align_start >= cnc_y_start, "main display not of sufficient vertical resolution (add an additional row of monitors)")
TextBox{parent=main,y=cnc_bottom_align_start,text=string.rep("\x8c", header.get_width()),alignment=ALIGN.CENTER,height=1,fg_bg=style.lg_gray}
cnc_bottom_align_start = cnc_bottom_align_start + 2
process_ctl(main, 2, cnc_bottom_align_start)
util.nop()
imatrix(main, 131, cnc_bottom_align_start, facility.induction_data_tbl[1], facility.induction_ps_tbl[1])
end
return init