cc-mek-scada/reactor-plc/startup.lua
2022-04-05 09:41:06 -04:00

229 lines
7.3 KiB
Lua

--
-- Reactor Programmable Logic Controller
--
os.loadAPI("scada-common/log.lua")
os.loadAPI("scada-common/util.lua")
os.loadAPI("scada-common/ppm.lua")
os.loadAPI("scada-common/comms.lua")
os.loadAPI("reactor-plc/config.lua")
os.loadAPI("reactor-plc/plc.lua")
local R_PLC_VERSION = "alpha-v0.1.0"
local print_ts = util.print_ts
print(">> Reactor PLC " .. R_PLC_VERSION .. " <<")
-- mount connected devices
ppm.mount_all()
local reactor = ppm.get_device("fissionReactor")
local modem = ppm.get_device("modem")
local plc_state = {
init_ok = true,
scram = true, -- treated as latching e-stop, all conditions must be OK to set false
degraded = false,
no_reactor = false,
no_modem = false
}
-- we need a reactor and a modem
if reactor == nil then
print_ts("Fission reactor not found. Running in a degraded state...\n");
log._warning("no reactor on startup")
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_reactor = true
end
if modem == nil then
if reactor ~= nil then
print_ts("No modem found. Disabling reactor and running in a degraded state...\n")
reactor.scram()
else
print_ts("No modem found. Running in a degraded state...\n")
end
log._warning("no modem on startup")
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_modem = true
end
::init::
if plc_state.init_ok then
-- just booting up, no fission allowed (neutrons stay put thanks)
reactor.scram()
-- init internal safety system
local iss = plc.iss_init(reactor)
log._debug("iss init")
-- start comms
local plc_comms = plc.comms_init(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor, iss)
log._debug("comms init")
-- comms watchdog, 3 second timeout
local conn_watchdog = watchdog.new_watchdog(3)
log._debug("conn watchdog started")
-- loop clock (10Hz, 2 ticks)
local loop_tick = os.startTimer(0.05)
log._debug("loop clock started")
else
log._warning("booted in a degraded state, awaiting peripheral connections...")
end
-- send status updates at ~3.33Hz (every 6 server ticks) (every 3 loop ticks)
-- send link requests at 0.5Hz (every 40 server ticks) (every 20 loop ticks)
local UPDATE_TICKS = 3
local LINK_TICKS = 20
-- start by linking
local ticks_to_update = LINK_TICKS
-- event loop
while true do
local event, param1, param2, param3, param4, param5 = os.pullEventRaw()
if plc_state.init_ok then
-- if we tried to SCRAM but failed, keep trying
-- if it disconnected, isPowered will return nil (and error logs will get spammed at 10Hz, so disable reporting)
-- in that case, SCRAM won't be called until it reconnects (this is the expected use of this check)
ppm.disable_reporting()
if plc_state.scram and reactor.isPowered() then
reactor.scram()
end
ppm.enable_reporting()
end
-- check for peripheral changes before ISS checks
if event == "peripheral_detach" then
local device = ppm.handle_unmount(param1)
if device.type == "fissionReactor" then
print_ts("reactor disconnected!\n")
log._error("reactor disconnected!")
plc_state.no_reactor = true
-- send an alarm: plc_comms.send_alarm(ALARMS.PLC_PERI_DC) ?
elseif device.type == "modem" then
print_ts("modem disconnected!\n")
log._error("modem disconnected!")
plc_state.no_modem = true
if plc_state.init_ok then
-- try to scram reactor if it is still connected
plc_state.scram = true
if reactor.scram() then
print_ts("successful reactor SCRAM\n")
else
print_ts("failed reactor SCRAM\n")
end
end
plc_state.degraded = true
end
elseif event == "peripheral" then
local device = ppm.mount(param1)
if device.type == "fissionReactor" then
-- reconnected reactor
plc_state.scram = true
device.scram()
print_ts("reactor reconnected.\n")
log._info("reactor reconnected.")
plc_state.no_reactor = false
if plc_state.init_ok then
iss.reconnect_reactor(device)
plc_comms.reconnect_reactor(device)
end
-- determine if we are still in a degraded state
if get_device("modem") not nil then
plc_state.degraded = false
end
elseif device.type == "modem" then
-- reconnected modem
if plc_state.init_ok then
plc_comms.reconnect_modem(device)
end
print_ts("modem reconnected.\n")
log._info("modem reconnected.")
plc_state.no_modem = false
-- determine if we are still in a degraded state
if ppm.get_device("fissionReactor") not nil then
plc_state.degraded = false
end
end
if not plc_state.init_ok and not plc_state.degraded then
plc_state.init_ok = false
goto init
end
end
-- check safety (SCRAM occurs if tripped)
if not plc_state.degraded then
local iss_tripped, iss_status, iss_first = iss.check()
plc_state.scram = plc_state.scram or iss_tripped
if iss_first then
plc_comms.send_iss_alarm(iss_status)
end
end
-- handle event
if event == "timer" and param1 == loop_tick then
if not plc_state.no_modem then
-- basic event tick, send updated data if it is time (~3.33Hz)
-- iss was already checked (main reason for this tick rate)
ticks_to_update = ticks_to_update - 1
if plc_comms.is_linked() then
if ticks_to_update <= 0 then
plc_comms.send_status(iss_tripped)
ticks_to_update = UPDATE_TICKS
end
else
if ticks_to_update <= 0 then
plc_comms.send_link_req()
ticks_to_update = LINK_TICKS
end
end
end
elseif event == "modem_message" then
-- got a packet
-- feed the watchdog first so it doesn't uhh...eat our packets
conn_watchdog.feed()
local packet = plc_comms.parse_packet(p1, p2, p3, p4, p5)
plc_comms.handle_packet(packet)
plc_state.scram = plc_state.scram or plc_comms.is_scrammed()
elseif event == "timer" and param1 == conn_watchdog.get_timer() then
-- haven't heard from server recently? shutdown reactor
plc_state.scram = true
plc_comms.unlink()
iss.trip_timeout()
print_ts("[alert] server timeout, reactor disabled\n")
elseif event == "terminate" then
-- safe exit
if plc_state.init_ok then
plc_state.scram = true
if reactor.scram() then
print_ts("[alert] exiting, reactor disabled\n")
else
-- send an alarm: plc_comms.send_alarm(ALARMS.PLC_LOST_CONTROL) ?
print_ts("[alert] exiting, reactor failed to disable\n")
end
end
-- send an alarm: plc_comms.send_alarm(ALARMS.PLC_SHUTDOWN) ?
print_ts("[alert] exited")
return
end
end