local comms = require("scada-common.comms")
|
|
local log = require("scada-common.log")
|
|
local psil = require("scada-common.psil")
|
|
local types = require("scada-common.types")
|
|
local util = require("scada-common.util")
|
|
|
|
local process = require("coordinator.process")
|
|
local sounder = require("coordinator.sounder")
|
|
|
|
local UNIT_COMMANDS = comms.UNIT_COMMANDS
|
|
|
|
local ALARM_STATE = types.ALARM_STATE
|
|
|
|
local iocontrol = {}
|
|
|
|
---@class ioctl
|
|
local io = {}
|
|
|
|
-- initialize the coordinator IO controller
|
|
---@param conf facility_conf configuration
|
|
---@param comms coord_comms comms reference
|
|
---@diagnostic disable-next-line: redefined-local
|
|
function iocontrol.init(conf, comms)
|
|
---@class ioctl_facility
|
|
io.facility = {
|
|
num_units = conf.num_units, ---@type integer
|
|
all_sys_ok = false,
|
|
rtu_count = 0,
|
|
|
|
auto_ready = false,
|
|
auto_active = false,
|
|
auto_ramping = false,
|
|
auto_saturated = false,
|
|
|
|
auto_scram = false,
|
|
---@type ascram_status
|
|
ascram_status = {
|
|
matrix_dc = false,
|
|
matrix_fill = false,
|
|
crit_alarm = false,
|
|
radiation = false,
|
|
gen_fault = false
|
|
},
|
|
|
|
radiation = types.new_zero_radiation_reading(),
|
|
|
|
save_cfg_ack = function (success) end, ---@param success boolean
|
|
start_ack = function (success) end, ---@param success boolean
|
|
stop_ack = function (success) end, ---@param success boolean
|
|
scram_ack = function (success) end, ---@param success boolean
|
|
ack_alarms_ack = function (success) end, ---@param success boolean
|
|
|
|
ps = psil.create(),
|
|
|
|
induction_ps_tbl = {},
|
|
induction_data_tbl = {},
|
|
|
|
env_d_ps = psil.create(),
|
|
env_d_data = {}
|
|
}
|
|
|
|
-- create induction tables (max 1 per unit, preferably 1 total)
|
|
for _ = 1, conf.num_units do
|
|
local data = {} ---@type imatrix_session_db
|
|
table.insert(io.facility.induction_ps_tbl, psil.create())
|
|
table.insert(io.facility.induction_data_tbl, data)
|
|
end
|
|
|
|
io.units = {}
|
|
for i = 1, conf.num_units do
|
|
local function ack(alarm) process.ack_alarm(i, alarm) end
|
|
local function reset(alarm) process.reset_alarm(i, alarm) end
|
|
|
|
---@class ioctl_unit
|
|
local entry = {
|
|
---@type integer
|
|
unit_id = i,
|
|
|
|
num_boilers = 0,
|
|
num_turbines = 0,
|
|
|
|
control_state = false,
|
|
burn_rate_cmd = 0.0,
|
|
waste_control = 0,
|
|
radiation = types.new_zero_radiation_reading(),
|
|
|
|
a_group = 0, -- auto control group
|
|
|
|
start = function () process.start(i) end,
|
|
scram = function () process.scram(i) end,
|
|
reset_rps = function () process.reset_rps(i) end,
|
|
ack_alarms = function () process.ack_all_alarms(i) end,
|
|
set_burn = function (rate) process.set_rate(i, rate) end, ---@param rate number burn rate
|
|
set_waste = function (mode) process.set_waste(i, mode) end, ---@param mode integer waste processing mode
|
|
|
|
set_group = function (grp) process.set_group(i, grp) end, ---@param grp integer|0 group ID or 0
|
|
|
|
start_ack = function (success) end, ---@param success boolean
|
|
scram_ack = function (success) end, ---@param success boolean
|
|
reset_rps_ack = function (success) end, ---@param success boolean
|
|
ack_alarms_ack = function (success) end, ---@param success boolean
|
|
set_burn_ack = function (success) end, ---@param success boolean
|
|
set_waste_ack = function (success) end, ---@param success boolean
|
|
|
|
alarm_callbacks = {
|
|
c_breach = { ack = function () ack(1) end, reset = function () reset(1) end },
|
|
radiation = { ack = function () ack(2) end, reset = function () reset(2) end },
|
|
r_lost = { ack = function () ack(3) end, reset = function () reset(3) end },
|
|
dmg_crit = { ack = function () ack(4) end, reset = function () reset(4) end },
|
|
damage = { ack = function () ack(5) end, reset = function () reset(5) end },
|
|
over_temp = { ack = function () ack(6) end, reset = function () reset(6) end },
|
|
high_temp = { ack = function () ack(7) end, reset = function () reset(7) end },
|
|
waste_leak = { ack = function () ack(8) end, reset = function () reset(8) end },
|
|
waste_high = { ack = function () ack(9) end, reset = function () reset(9) end },
|
|
rps_trans = { ack = function () ack(10) end, reset = function () reset(10) end },
|
|
rcs_trans = { ack = function () ack(11) end, reset = function () reset(11) end },
|
|
t_trip = { ack = function () ack(12) end, reset = function () reset(12) end }
|
|
},
|
|
|
|
---@type alarms
|
|
alarms = {
|
|
ALARM_STATE.INACTIVE, -- containment breach
|
|
ALARM_STATE.INACTIVE, -- containment radiation
|
|
ALARM_STATE.INACTIVE, -- reactor lost
|
|
ALARM_STATE.INACTIVE, -- damage critical
|
|
ALARM_STATE.INACTIVE, -- reactor taking damage
|
|
ALARM_STATE.INACTIVE, -- reactor over temperature
|
|
ALARM_STATE.INACTIVE, -- reactor high temperature
|
|
ALARM_STATE.INACTIVE, -- waste leak
|
|
ALARM_STATE.INACTIVE, -- waste level high
|
|
ALARM_STATE.INACTIVE, -- RPS transient
|
|
ALARM_STATE.INACTIVE, -- RCS transient
|
|
ALARM_STATE.INACTIVE -- turbine trip
|
|
},
|
|
|
|
annunciator = {}, ---@type annunciator
|
|
|
|
unit_ps = psil.create(),
|
|
reactor_data = {}, ---@type reactor_db
|
|
|
|
boiler_ps_tbl = {},
|
|
boiler_data_tbl = {},
|
|
|
|
turbine_ps_tbl = {},
|
|
turbine_data_tbl = {}
|
|
}
|
|
|
|
-- create boiler tables
|
|
for _ = 1, conf.defs[(i * 2) - 1] do
|
|
local data = {} ---@type boilerv_session_db
|
|
table.insert(entry.boiler_ps_tbl, psil.create())
|
|
table.insert(entry.boiler_data_tbl, data)
|
|
end
|
|
|
|
-- create turbine tables
|
|
for _ = 1, conf.defs[i * 2] do
|
|
local data = {} ---@type turbinev_session_db
|
|
table.insert(entry.turbine_ps_tbl, psil.create())
|
|
table.insert(entry.turbine_data_tbl, data)
|
|
end
|
|
|
|
entry.num_boilers = #entry.boiler_data_tbl
|
|
entry.num_turbines = #entry.turbine_data_tbl
|
|
|
|
table.insert(io.units, entry)
|
|
end
|
|
|
|
-- pass IO control here since it can't be require'd due to a require loop
|
|
process.init(io, comms)
|
|
end
|
|
|
|
-- populate facility structure builds
|
|
---@param build table
|
|
---@return boolean valid
|
|
function iocontrol.record_facility_builds(build)
|
|
if type(build) == "table" then
|
|
local fac = io.facility
|
|
|
|
-- induction matricies
|
|
if type(build.induction) == "table" then
|
|
for id, matrix in pairs(build.induction) do
|
|
if type(fac.induction_data_tbl[id]) == "table" then
|
|
fac.induction_data_tbl[id].formed = matrix[1] ---@type boolean
|
|
fac.induction_data_tbl[id].build = matrix[2] ---@type table
|
|
|
|
fac.induction_ps_tbl[id].publish("formed", matrix[1])
|
|
|
|
for key, val in pairs(fac.induction_data_tbl[id].build) do
|
|
fac.induction_ps_tbl[id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c("iocontrol.record_facility_builds: invalid induction matrix id ", id))
|
|
end
|
|
end
|
|
end
|
|
else
|
|
log.error("facility builds not a table")
|
|
return false
|
|
end
|
|
|
|
return true
|
|
end
|
|
|
|
-- populate unit structure builds
|
|
---@param builds table
|
|
---@return boolean valid
|
|
function iocontrol.record_unit_builds(builds)
|
|
-- note: if not all units and RTUs are connected, some will be nil
|
|
for id, build in pairs(builds) do
|
|
local unit = io.units[id] ---@type ioctl_unit
|
|
|
|
if type(build) ~= "table" then
|
|
log.error(util.c("corrupted unit builds provided, unit ", id, " not a table"))
|
|
return false
|
|
elseif type(unit) ~= "table" then
|
|
log.error(util.c("corrupted unit builds provided, invalid unit ", id))
|
|
return false
|
|
end
|
|
|
|
local log_header = util.c("iocontrol.record_unit_builds[unit ", id, "]: ")
|
|
|
|
-- reactor build
|
|
if type(build.reactor) == "table" then
|
|
unit.reactor_data.mek_struct = build.reactor ---@type mek_struct
|
|
for key, val in pairs(unit.reactor_data.mek_struct) do
|
|
unit.unit_ps.publish(key, val)
|
|
end
|
|
|
|
if (type(unit.reactor_data.mek_struct.length) == "number") and (unit.reactor_data.mek_struct.length ~= 0) and
|
|
(type(unit.reactor_data.mek_struct.width) == "number") and (unit.reactor_data.mek_struct.width ~= 0) then
|
|
unit.unit_ps.publish("size", { unit.reactor_data.mek_struct.length, unit.reactor_data.mek_struct.width })
|
|
end
|
|
end
|
|
|
|
-- boiler builds
|
|
if type(build.boilers) == "table" then
|
|
for b_id, boiler in pairs(build.boilers) do
|
|
if type(unit.boiler_data_tbl[b_id]) == "table" then
|
|
unit.boiler_data_tbl[b_id].formed = boiler[1] ---@type boolean
|
|
unit.boiler_data_tbl[b_id].build = boiler[2] ---@type table
|
|
|
|
unit.boiler_ps_tbl[b_id].publish("formed", boiler[1])
|
|
|
|
for key, val in pairs(unit.boiler_data_tbl[b_id].build) do
|
|
unit.boiler_ps_tbl[b_id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c(log_header, "invalid boiler id ", b_id))
|
|
end
|
|
end
|
|
end
|
|
|
|
-- turbine builds
|
|
if type(build.turbines) == "table" then
|
|
for t_id, turbine in pairs(build.turbines) do
|
|
if type(unit.turbine_data_tbl[t_id]) == "table" then
|
|
unit.turbine_data_tbl[t_id].formed = turbine[1] ---@type boolean
|
|
unit.turbine_data_tbl[t_id].build = turbine[2] ---@type table
|
|
|
|
unit.turbine_ps_tbl[t_id].publish("formed", turbine[1])
|
|
|
|
for key, val in pairs(unit.turbine_data_tbl[t_id].build) do
|
|
unit.turbine_ps_tbl[t_id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c(log_header, "invalid turbine id ", t_id))
|
|
end
|
|
end
|
|
end
|
|
end
|
|
|
|
return true
|
|
end
|
|
|
|
-- update facility status
|
|
---@param status table
|
|
---@return boolean valid
|
|
function iocontrol.update_facility_status(status)
|
|
local log_header = util.c("iocontrol.update_facility_status: ")
|
|
if type(status) ~= "table" then
|
|
log.debug(log_header .. "status not a table")
|
|
return false
|
|
else
|
|
local fac = io.facility
|
|
|
|
-- auto control status information
|
|
|
|
local ctl_status = status[1]
|
|
|
|
if type(ctl_status) == "table" and (#ctl_status == 14) then
|
|
fac.all_sys_ok = ctl_status[1]
|
|
fac.auto_ready = ctl_status[2]
|
|
fac.auto_active = ctl_status[3] > 0
|
|
fac.auto_ramping = ctl_status[4]
|
|
fac.auto_saturated = ctl_status[5]
|
|
|
|
fac.auto_scram = ctl_status[6]
|
|
fac.ascram_status.matrix_dc = ctl_status[7]
|
|
fac.ascram_status.matrix_fill = ctl_status[8]
|
|
fac.ascram_status.crit_alarm = ctl_status[9]
|
|
fac.ascram_status.radiation = ctl_status[10]
|
|
fac.ascram_status.gen_fault = ctl_status[11]
|
|
|
|
fac.status_line_1 = ctl_status[12]
|
|
fac.status_line_2 = ctl_status[13]
|
|
|
|
fac.ps.publish("all_sys_ok", fac.all_sys_ok)
|
|
fac.ps.publish("auto_ready", fac.auto_ready)
|
|
fac.ps.publish("auto_active", fac.auto_active)
|
|
fac.ps.publish("auto_ramping", fac.auto_ramping)
|
|
fac.ps.publish("auto_saturated", fac.auto_saturated)
|
|
fac.ps.publish("auto_scram", fac.auto_scram)
|
|
fac.ps.publish("as_matrix_dc", fac.ascram_status.matrix_dc)
|
|
fac.ps.publish("as_matrix_fill", fac.ascram_status.matrix_fill)
|
|
fac.ps.publish("as_crit_alarm", fac.ascram_status.crit_alarm)
|
|
fac.ps.publish("as_radiation", fac.ascram_status.radiation)
|
|
fac.ps.publish("as_gen_fault", fac.ascram_status.gen_fault)
|
|
fac.ps.publish("status_line_1", fac.status_line_1)
|
|
fac.ps.publish("status_line_2", fac.status_line_2)
|
|
|
|
local group_map = ctl_status[14]
|
|
|
|
if (type(group_map) == "table") and (#group_map == fac.num_units) then
|
|
local names = { "Manual", "Primary", "Secondary", "Tertiary", "Backup" }
|
|
for i = 1, #group_map do
|
|
io.units[i].a_group = group_map[i]
|
|
io.units[i].unit_ps.publish("auto_group_id", group_map[i])
|
|
io.units[i].unit_ps.publish("auto_group", names[group_map[i] + 1])
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "control status not a table or length mismatch")
|
|
end
|
|
|
|
-- RTU statuses
|
|
|
|
local rtu_statuses = status[2]
|
|
|
|
fac.rtu_count = 0
|
|
if type(rtu_statuses) == "table" then
|
|
-- connected RTU count
|
|
fac.rtu_count = rtu_statuses.count
|
|
fac.ps.publish("rtu_count", fac.rtu_count)
|
|
|
|
-- power statistics
|
|
if type(rtu_statuses.power) == "table" then
|
|
fac.induction_ps_tbl[1].publish("avg_charge", rtu_statuses.power[1])
|
|
fac.induction_ps_tbl[1].publish("avg_inflow", rtu_statuses.power[2])
|
|
fac.induction_ps_tbl[1].publish("avg_outflow", rtu_statuses.power[3])
|
|
else
|
|
log.debug(log_header .. "power statistics list not a table")
|
|
end
|
|
|
|
-- induction matricies statuses
|
|
if type(rtu_statuses.induction) == "table" then
|
|
for id = 1, #fac.induction_ps_tbl do
|
|
if rtu_statuses.induction[id] == nil then
|
|
-- disconnected
|
|
fac.induction_ps_tbl[id].publish("computed_status", 1)
|
|
end
|
|
end
|
|
|
|
for id, matrix in pairs(rtu_statuses.induction) do
|
|
if type(fac.induction_data_tbl[id]) == "table" then
|
|
local rtu_faulted = matrix[1] ---@type boolean
|
|
fac.induction_data_tbl[id].formed = matrix[2] ---@type boolean
|
|
fac.induction_data_tbl[id].state = matrix[3] ---@type table
|
|
fac.induction_data_tbl[id].tanks = matrix[4] ---@type table
|
|
|
|
local data = fac.induction_data_tbl[id] ---@type imatrix_session_db
|
|
|
|
fac.induction_ps_tbl[id].publish("formed", data.formed)
|
|
fac.induction_ps_tbl[id].publish("faulted", rtu_faulted)
|
|
|
|
if data.formed then
|
|
if rtu_faulted then
|
|
fac.induction_ps_tbl[id].publish("computed_status", 3) -- faulted
|
|
elseif data.tanks.energy_fill >= 0.99 then
|
|
fac.induction_ps_tbl[id].publish("computed_status", 6) -- full
|
|
elseif data.tanks.energy_fill <= 0.01 then
|
|
fac.induction_ps_tbl[id].publish("computed_status", 5) -- empty
|
|
else
|
|
fac.induction_ps_tbl[id].publish("computed_status", 4) -- on-line
|
|
end
|
|
else
|
|
fac.induction_ps_tbl[id].publish("computed_status", 2) -- not formed
|
|
end
|
|
|
|
for key, val in pairs(fac.induction_data_tbl[id].state) do
|
|
fac.induction_ps_tbl[id].publish(key, val)
|
|
end
|
|
|
|
for key, val in pairs(fac.induction_data_tbl[id].tanks) do
|
|
fac.induction_ps_tbl[id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c(log_header, "invalid induction matrix id ", id))
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "induction matrix list not a table")
|
|
end
|
|
|
|
-- environment detector status
|
|
if type(rtu_statuses.rad_mon) == "table" then
|
|
if #rtu_statuses.rad_mon > 0 then
|
|
local rad_mon = rtu_statuses.rad_mon[1]
|
|
local rtu_faulted = rad_mon[1] ---@type boolean
|
|
fac.radiation = rad_mon[2] ---@type number
|
|
|
|
fac.ps.publish("rad_computed_status", util.trinary(rtu_faulted, 2, 3))
|
|
fac.ps.publish("radiation", fac.radiation)
|
|
else
|
|
fac.radiation = types.new_zero_radiation_reading()
|
|
fac.ps.publish("rad_computed_status", 1)
|
|
end
|
|
else
|
|
log.debug(log_header .. "radiation monitor list not a table")
|
|
return false
|
|
end
|
|
else
|
|
log.debug(log_header .. "rtu statuses not a table")
|
|
end
|
|
end
|
|
|
|
return true
|
|
end
|
|
|
|
-- update unit statuses
|
|
---@param statuses table
|
|
---@return boolean valid
|
|
function iocontrol.update_unit_statuses(statuses)
|
|
if type(statuses) ~= "table" then
|
|
log.debug("iocontrol.update_unit_statuses: unit statuses not a table")
|
|
return false
|
|
elseif #statuses ~= #io.units then
|
|
log.debug("iocontrol.update_unit_statuses: number of provided unit statuses does not match expected number of units")
|
|
return false
|
|
else
|
|
local burn_rate_sum = 0.0
|
|
|
|
-- get all unit statuses
|
|
for i = 1, #statuses do
|
|
local log_header = util.c("iocontrol.update_unit_statuses[unit ", i, "]: ")
|
|
local unit = io.units[i] ---@type ioctl_unit
|
|
local status = statuses[i]
|
|
|
|
if type(status) ~= "table" or #status ~= 5 then
|
|
log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)")
|
|
return false
|
|
end
|
|
|
|
-- reactor PLC status
|
|
|
|
local reactor_status = status[1]
|
|
|
|
if type(reactor_status) ~= "table" then
|
|
reactor_status = {}
|
|
log.debug(log_header .. "reactor status not a table")
|
|
end
|
|
|
|
if #reactor_status == 0 then
|
|
unit.unit_ps.publish("computed_status", 1) -- disconnected
|
|
elseif #reactor_status == 3 then
|
|
local mek_status = reactor_status[1]
|
|
local rps_status = reactor_status[2]
|
|
local gen_status = reactor_status[3]
|
|
|
|
if #gen_status == 6 then
|
|
unit.reactor_data.last_status_update = gen_status[1]
|
|
unit.reactor_data.control_state = gen_status[2]
|
|
unit.reactor_data.rps_tripped = gen_status[3]
|
|
unit.reactor_data.rps_trip_cause = gen_status[4]
|
|
unit.reactor_data.no_reactor = gen_status[5]
|
|
unit.reactor_data.formed = gen_status[6]
|
|
else
|
|
log.debug(log_header .. "reactor general status length mismatch")
|
|
end
|
|
|
|
unit.reactor_data.rps_status = rps_status ---@type rps_status
|
|
unit.reactor_data.mek_status = mek_status ---@type mek_status
|
|
|
|
-- if status hasn't been received, mek_status = {}
|
|
if type(unit.reactor_data.mek_status.act_burn_rate) == "number" then
|
|
burn_rate_sum = burn_rate_sum + unit.reactor_data.mek_status.act_burn_rate
|
|
end
|
|
|
|
if unit.reactor_data.mek_status.status then
|
|
unit.unit_ps.publish("computed_status", 5) -- running
|
|
else
|
|
if unit.reactor_data.no_reactor then
|
|
unit.unit_ps.publish("computed_status", 3) -- faulted
|
|
elseif not unit.reactor_data.formed then
|
|
unit.unit_ps.publish("computed_status", 2) -- multiblock not formed
|
|
elseif unit.reactor_data.rps_status.force_dis then
|
|
unit.unit_ps.publish("computed_status", 7) -- reactor force disabled
|
|
elseif unit.reactor_data.rps_tripped and unit.reactor_data.rps_trip_cause ~= "manual" then
|
|
unit.unit_ps.publish("computed_status", 6) -- SCRAM
|
|
else
|
|
unit.unit_ps.publish("computed_status", 4) -- disabled
|
|
end
|
|
end
|
|
|
|
for key, val in pairs(unit.reactor_data) do
|
|
if key ~= "rps_status" and key ~= "mek_struct" and key ~= "mek_status" then
|
|
unit.unit_ps.publish(key, val)
|
|
end
|
|
end
|
|
|
|
if type(unit.reactor_data.rps_status) == "table" then
|
|
for key, val in pairs(unit.reactor_data.rps_status) do
|
|
unit.unit_ps.publish(key, val)
|
|
end
|
|
end
|
|
|
|
if type(unit.reactor_data.mek_status) == "table" then
|
|
for key, val in pairs(unit.reactor_data.mek_status) do
|
|
unit.unit_ps.publish(key, val)
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "reactor status length mismatch")
|
|
end
|
|
|
|
-- RTU statuses
|
|
|
|
local rtu_statuses = status[2]
|
|
|
|
if type(rtu_statuses) == "table" then
|
|
-- boiler statuses
|
|
if type(rtu_statuses.boilers) == "table" then
|
|
for id = 1, #unit.boiler_ps_tbl do
|
|
if rtu_statuses.boilers[i] == nil then
|
|
-- disconnected
|
|
unit.boiler_ps_tbl[id].publish("computed_status", 1)
|
|
end
|
|
end
|
|
|
|
for id, boiler in pairs(rtu_statuses.boilers) do
|
|
if type(unit.boiler_data_tbl[id]) == "table" then
|
|
local rtu_faulted = boiler[1] ---@type boolean
|
|
unit.boiler_data_tbl[id].formed = boiler[2] ---@type boolean
|
|
unit.boiler_data_tbl[id].state = boiler[3] ---@type table
|
|
unit.boiler_data_tbl[id].tanks = boiler[4] ---@type table
|
|
|
|
local data = unit.boiler_data_tbl[id] ---@type boilerv_session_db
|
|
|
|
unit.boiler_ps_tbl[id].publish("formed", data.formed)
|
|
unit.boiler_ps_tbl[id].publish("faulted", rtu_faulted)
|
|
|
|
if data.formed then
|
|
if rtu_faulted then
|
|
unit.boiler_ps_tbl[id].publish("computed_status", 3) -- faulted
|
|
elseif data.state.boil_rate > 0 then
|
|
unit.boiler_ps_tbl[id].publish("computed_status", 5) -- active
|
|
else
|
|
unit.boiler_ps_tbl[id].publish("computed_status", 4) -- idle
|
|
end
|
|
else
|
|
unit.boiler_ps_tbl[id].publish("computed_status", 2) -- not formed
|
|
end
|
|
|
|
for key, val in pairs(unit.boiler_data_tbl[id].state) do
|
|
unit.boiler_ps_tbl[id].publish(key, val)
|
|
end
|
|
|
|
for key, val in pairs(unit.boiler_data_tbl[id].tanks) do
|
|
unit.boiler_ps_tbl[id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c(log_header, "invalid boiler id ", id))
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "boiler list not a table")
|
|
end
|
|
|
|
-- turbine statuses
|
|
if type(rtu_statuses.turbines) == "table" then
|
|
for id = 1, #unit.turbine_ps_tbl do
|
|
if rtu_statuses.turbines[i] == nil then
|
|
-- disconnected
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 1)
|
|
end
|
|
end
|
|
|
|
for id, turbine in pairs(rtu_statuses.turbines) do
|
|
if type(unit.turbine_data_tbl[id]) == "table" then
|
|
local rtu_faulted = turbine[1] ---@type boolean
|
|
unit.turbine_data_tbl[id].formed = turbine[2] ---@type boolean
|
|
unit.turbine_data_tbl[id].state = turbine[3] ---@type table
|
|
unit.turbine_data_tbl[id].tanks = turbine[4] ---@type table
|
|
|
|
local data = unit.turbine_data_tbl[id] ---@type turbinev_session_db
|
|
|
|
unit.turbine_ps_tbl[id].publish("formed", data.formed)
|
|
unit.turbine_ps_tbl[id].publish("faulted", rtu_faulted)
|
|
|
|
if data.formed then
|
|
if data.tanks.energy_fill >= 0.99 then
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 6) -- trip
|
|
elseif rtu_faulted then
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 3) -- faulted
|
|
elseif data.state.flow_rate < 100 then
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 4) -- idle
|
|
else
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 5) -- active
|
|
end
|
|
else
|
|
unit.turbine_ps_tbl[id].publish("computed_status", 2) -- not formed
|
|
end
|
|
|
|
for key, val in pairs(unit.turbine_data_tbl[id].state) do
|
|
unit.turbine_ps_tbl[id].publish(key, val)
|
|
end
|
|
|
|
for key, val in pairs(unit.turbine_data_tbl[id].tanks) do
|
|
unit.turbine_ps_tbl[id].publish(key, val)
|
|
end
|
|
else
|
|
log.debug(util.c(log_header, "invalid turbine id ", id))
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "turbine list not a table")
|
|
return false
|
|
end
|
|
|
|
-- environment detector status
|
|
if type(rtu_statuses.rad_mon) == "table" then
|
|
if #rtu_statuses.rad_mon > 0 then
|
|
local rad_mon = rtu_statuses.rad_mon[1]
|
|
local rtu_faulted = rad_mon[1] ---@type boolean
|
|
unit.radiation = rad_mon[2] ---@type number
|
|
|
|
unit.unit_ps.publish("radiation", unit.radiation)
|
|
else
|
|
unit.radiation = types.new_zero_radiation_reading()
|
|
end
|
|
else
|
|
log.debug(log_header .. "radiation monitor list not a table")
|
|
return false
|
|
end
|
|
else
|
|
log.debug(log_header .. "rtu list not a table")
|
|
end
|
|
|
|
-- annunciator
|
|
|
|
unit.annunciator = status[3]
|
|
|
|
if type(unit.annunciator) ~= "table" then
|
|
unit.annunciator = {}
|
|
log.debug(log_header .. "annunciator state not a table")
|
|
end
|
|
|
|
for key, val in pairs(unit.annunciator) do
|
|
if key == "TurbineTrip" then
|
|
-- split up turbine trip table for all turbines and a general OR combination
|
|
local trips = val
|
|
local any = false
|
|
|
|
for id = 1, #trips do
|
|
any = any or trips[id]
|
|
unit.turbine_ps_tbl[id].publish(key, trips[id])
|
|
end
|
|
|
|
unit.unit_ps.publish("TurbineTrip", any)
|
|
elseif key == "BoilerOnline" or key == "HeatingRateLow" or key == "WaterLevelLow" then
|
|
-- split up array for all boilers
|
|
for id = 1, #val do
|
|
unit.boiler_ps_tbl[id].publish(key, val[id])
|
|
end
|
|
elseif key == "TurbineOnline" or key == "SteamDumpOpen" or key == "TurbineOverSpeed" then
|
|
-- split up array for all turbines
|
|
for id = 1, #val do
|
|
unit.turbine_ps_tbl[id].publish(key, val[id])
|
|
end
|
|
elseif type(val) == "table" then
|
|
-- we missed one of the tables?
|
|
log.error(log_header .. "unrecognized table found in annunciator list, this is a bug", true)
|
|
else
|
|
-- non-table fields
|
|
unit.unit_ps.publish(key, val)
|
|
end
|
|
end
|
|
|
|
-- alarms
|
|
|
|
local alarm_states = status[4]
|
|
|
|
if type(alarm_states) == "table" then
|
|
for id = 1, #alarm_states do
|
|
local state = alarm_states[id]
|
|
|
|
unit.alarms[id] = state
|
|
|
|
if state == types.ALARM_STATE.TRIPPED or state == types.ALARM_STATE.ACKED then
|
|
unit.unit_ps.publish("Alarm_" .. id, 2)
|
|
elseif state == types.ALARM_STATE.RING_BACK then
|
|
unit.unit_ps.publish("Alarm_" .. id, 3)
|
|
else
|
|
unit.unit_ps.publish("Alarm_" .. id, 1)
|
|
end
|
|
end
|
|
else
|
|
log.debug(log_header .. "alarm states not a table")
|
|
end
|
|
|
|
-- unit state fields
|
|
|
|
local unit_state = status[5]
|
|
|
|
if type(unit_state) == "table" then
|
|
if #unit_state == 5 then
|
|
unit.unit_ps.publish("U_StatusLine1", unit_state[1])
|
|
unit.unit_ps.publish("U_StatusLine2", unit_state[2])
|
|
unit.unit_ps.publish("U_WasteMode", unit_state[3])
|
|
unit.unit_ps.publish("U_AutoReady", unit_state[4])
|
|
unit.unit_ps.publish("U_AutoDegraded", unit_state[5])
|
|
else
|
|
log.debug(log_header .. "unit state length mismatch")
|
|
end
|
|
else
|
|
log.debug(log_header .. "unit state not a table")
|
|
end
|
|
end
|
|
|
|
io.facility.ps.publish("burn_sum", burn_rate_sum)
|
|
|
|
-- update alarm sounder
|
|
sounder.eval(io.units)
|
|
end
|
|
|
|
return true
|
|
end
|
|
|
|
-- get the IO controller database
|
|
function iocontrol.get_db() return io end
|
|
|
|
return iocontrol
|