cc-mek-scada/supervisor/session/rtu.lua
2023-05-05 13:04:13 -04:00

404 lines
15 KiB
Lua

local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local svqtypes = require("supervisor.session.svqtypes")
-- supervisor rtu sessions (svrs)
local unit_session = require("supervisor.session.rtu.unit_session")
local svrs_boilerv = require("supervisor.session.rtu.boilerv")
local svrs_envd = require("supervisor.session.rtu.envd")
local svrs_imatrix = require("supervisor.session.rtu.imatrix")
local svrs_redstone = require("supervisor.session.rtu.redstone")
local svrs_sna = require("supervisor.session.rtu.sna")
local svrs_sps = require("supervisor.session.rtu.sps")
local svrs_turbinev = require("supervisor.session.rtu.turbinev")
local rtu = {}
local PROTOCOL = comms.PROTOCOL
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
-- local println = util.println
local println = function (str) end
local PERIODICS = {
KEEP_ALIVE = 2000
}
-- create a new RTU session
---@nodiscard
---@param id integer session ID
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
---@param advertisement table RTU device advertisement
---@param facility facility facility data table
function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facility)
local log_header = "rtu_session(" .. id .. "): "
local self = {
modbus_q = mqueue.new(),
advert = advertisement,
fac_units = facility.get_units(),
-- connection properties
seq_num = 0,
r_seq_num = nil,
connected = true,
conn_watchdog = util.new_watchdog(timeout),
last_rtt = 0,
-- periodic messages
periodics = {
last_update = 0,
keep_alive = 0
},
units = {}
}
---@class rtu_session
local public = {}
local function _reset_config()
self.units = {}
end
-- parse the recorded advertisement and create unit sub-sessions
local function _handle_advertisement()
_reset_config()
for i = 1, #self.fac_units do
local unit = self.fac_units[i] ---@type reactor_unit
unit.purge_rtu_devices(id)
facility.purge_rtu_devices(id)
end
for i = 1, #self.advert do
local unit = nil ---@type unit_session|nil
---@type rtu_advertisement
local unit_advert = {
type = self.advert[i][1],
index = self.advert[i][2],
reactor = self.advert[i][3],
rsio = self.advert[i][4]
}
local u_type = unit_advert.type ---@type integer|boolean
-- validate unit advertisement
local advert_validator = util.new_validator()
advert_validator.assert_type_int(unit_advert.index)
advert_validator.assert_type_int(unit_advert.reactor)
if u_type == RTU_UNIT_TYPE.REDSTONE then
advert_validator.assert_type_table(unit_advert.rsio)
end
if advert_validator.valid() then
advert_validator.assert_min(unit_advert.index, 1)
advert_validator.assert_min(unit_advert.reactor, 0)
advert_validator.assert_max(unit_advert.reactor, #self.fac_units)
if not advert_validator.valid() then u_type = false end
else
u_type = false
end
local type_string = util.strval(u_type)
if type(u_type) == "number" then type_string = types.rtu_type_to_string(u_type) end
-- create unit by type
if u_type == false then
-- validation fail
log.debug(log_header .. "advertisement unit validation failure")
else
if unit_advert.reactor > 0 then
local target_unit = self.fac_units[unit_advert.reactor] ---@type reactor_unit
if u_type == RTU_UNIT_TYPE.REDSTONE then
-- redstone
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_redstone(unit) end
elseif u_type == RTU_UNIT_TYPE.BOILER_VALVE then
-- boiler (Mekanism 10.1+)
unit = svrs_boilerv.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_boiler(unit) end
elseif u_type == RTU_UNIT_TYPE.TURBINE_VALVE then
-- turbine (Mekanism 10.1+)
unit = svrs_turbinev.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_turbine(unit) end
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_envd(unit) end
else
log.error(util.c(log_header, "bad advertisement: encountered unsupported reactor-specific RTU type ", type_string))
end
else
if u_type == RTU_UNIT_TYPE.REDSTONE then
-- redstone
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_redstone(unit) end
elseif u_type == RTU_UNIT_TYPE.IMATRIX then
-- induction matrix
unit = svrs_imatrix.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_imatrix(unit) end
elseif u_type == RTU_UNIT_TYPE.SPS then
-- super-critical phase shifter
unit = svrs_sps.new(id, i, unit_advert, self.modbus_q)
elseif u_type == RTU_UNIT_TYPE.SNA then
-- solar neutron activator
unit = svrs_sna.new(id, i, unit_advert, self.modbus_q)
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_envd(unit) end
else
log.error(util.c(log_header, "bad advertisement: encountered unsupported reactor-independent RTU type ", type_string))
end
end
end
if unit ~= nil then
table.insert(self.units, unit)
else
_reset_config()
log.error(util.c(log_header, "bad advertisement: error occured while creating a unit (type is ", type_string, ")"))
break
end
end
end
-- mark this RTU session as closed, stop watchdog
local function _close()
self.conn_watchdog.cancel()
self.connected = false
-- mark all RTU unit sessions as closed so the reactor unit knows
for i = 1, #self.units do
self.units[i].close()
end
end
-- send a MODBUS packet
---@param m_pkt modbus_packet MODBUS packet
local function _send_modbus(m_pkt)
local s_pkt = comms.scada_packet()
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
end
-- send a SCADA management packet
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send_mgmt(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
end
-- handle a packet
---@param pkt modbus_frame|mgmt_frame
local function _handle_packet(pkt)
-- check sequence number
if self.r_seq_num == nil then
self.r_seq_num = pkt.scada_frame.seq_num()
elseif (self.r_seq_num + 1) ~= pkt.scada_frame.seq_num() then
log.warning(log_header .. "sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. pkt.scada_frame.seq_num())
return
else
self.r_seq_num = pkt.scada_frame.seq_num()
end
-- feed watchdog
self.conn_watchdog.feed()
-- process packet
if pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
---@cast pkt modbus_frame
if self.units[pkt.unit_id] ~= nil then
local unit = self.units[pkt.unit_id] ---@type unit_session
unit.handle_packet(pkt)
end
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
---@cast pkt mgmt_frame
-- handle management packet
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive reply
if pkt.length == 2 then
local srv_start = pkt.data[1]
-- local rtu_send = pkt.data[2]
local srv_now = util.time()
self.last_rtt = srv_now - srv_start
if self.last_rtt > 750 then
log.warning(log_header .. "RTU KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
end
-- log.debug(log_header .. "RTU RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "RTU TT = " .. (srv_now - rtu_send) .. "ms")
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
elseif pkt.type == SCADA_MGMT_TYPE.RTU_ADVERT then
-- RTU unit advertisement
log.debug(log_header .. "received updated advertisement")
self.advert = pkt.data
-- handle advertisement; this will re-create all unit sub-sessions
_handle_advertisement()
elseif pkt.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT then
if pkt.length == 1 then
local unit_id = pkt.data[1]
if self.units[unit_id] ~= nil then
local unit = self.units[unit_id] ---@type unit_session
unit.invalidate_cache()
end
else
log.debug(log_header .. "SCADA RTU device re-mount packet length mismatch")
end
else
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end
end
end
-- PUBLIC FUNCTIONS --
-- get the session ID
function public.get_id() return id end
-- check if a timer matches this session's watchdog
---@nodiscard
---@param timer number
function public.check_wd(timer)
return self.conn_watchdog.is_timer(timer) and self.connected
end
-- close the connection
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println(log_header .. "connection to RTU closed by server")
log.info(log_header .. "session closed by server")
end
-- iterate the session
---@nodiscard
---@return boolean connected
function public.iterate()
if self.connected then
------------------
-- handle queue --
------------------
local handle_start = util.time()
while in_queue.ready() and self.connected do
-- get a new message to process
local msg = in_queue.pop()
if msg ~= nil then
if msg.qtype == mqueue.TYPE.PACKET then
-- handle a packet
_handle_packet(msg.message)
elseif msg.qtype == mqueue.TYPE.COMMAND then
-- handle instruction
elseif msg.qtype == mqueue.TYPE.DATA then
-- instruction with body
end
end
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log.warning(log_header .. "exceeded 100ms queue process limit")
break
end
end
-- exit if connection was closed
if not self.connected then
println("RTU connection " .. id .. " closed by remote host")
log.info(log_header .. "session closed by remote host")
return self.connected
end
------------------
-- update units --
------------------
local time_now = util.time()
for i = 1, #self.units do
self.units[i].update(time_now)
end
----------------------
-- update periodics --
----------------------
local elapsed = util.time() - self.periodics.last_update
local periodics = self.periodics
-- keep alive
periodics.keep_alive = periodics.keep_alive + elapsed
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
periodics.keep_alive = 0
end
self.periodics.last_update = util.time()
--------------------------------------------
-- process RTU session handler out queues --
--------------------------------------------
for _ = 1, self.modbus_q.length() do
-- get the next message
local msg = self.modbus_q.pop()
if msg ~= nil then
if msg.qtype == mqueue.TYPE.PACKET then
-- handle a packet
_send_modbus(msg.message)
elseif msg.qtype == mqueue.TYPE.COMMAND then
-- handle instruction
elseif msg.qtype == mqueue.TYPE.DATA then
-- instruction with body
local cmd = msg.message ---@type queue_data
if cmd.key == unit_session.RTU_US_DATA.BUILD_CHANGED then
out_queue.push_data(svqtypes.SV_Q_DATA.RTU_BUILD_CHANGED, cmd.val)
end
end
end
end
end
return self.connected
end
-- handle initial advertisement
_handle_advertisement()
return public
end
return rtu