cc-mek-scada/coordinator/ui/components/processctl.lua
2023-02-26 14:22:25 -05:00

268 lines
14 KiB
Lua

local tcd = require("scada-common.tcallbackdsp")
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
local process = require("coordinator.process")
local style = require("coordinator.ui.style")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local Rectangle = require("graphics.elements.rectangle")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local IndicatorLight = require("graphics.elements.indicators.light")
local RadIndicator = require("graphics.elements.indicators.rad")
local TriIndicatorLight = require("graphics.elements.indicators.trilight")
local HazardButton = require("graphics.elements.controls.hazard_button")
local RadioButton = require("graphics.elements.controls.radio_button")
local SpinboxNumeric = require("graphics.elements.controls.spinbox_numeric")
local TEXT_ALIGN = core.graphics.TEXT_ALIGN
local cpair = core.graphics.cpair
local border = core.graphics.border
local period = core.flasher.PERIOD
-- new process control view
---@param root graphics_element parent
---@param x integer top left x
---@param y integer top left y
local function new_view(root, x, y)
assert(root.height() >= (y + 24), "main display not of sufficient vertical resolution (add an additional row of monitors)")
local facility = iocontrol.get_db().facility
local units = iocontrol.get_db().units
local bw_fg_bg = cpair(colors.black, colors.white)
local hzd_fg_bg = cpair(colors.white, colors.gray)
local lu_cpair = cpair(colors.gray, colors.gray)
local dis_colors = cpair(colors.white, colors.lightGray)
local main = Div{parent=root,width=104,height=24,x=x,y=y}
local scram = HazardButton{parent=main,x=1,y=1,text="FAC SCRAM",accent=colors.yellow,dis_colors=dis_colors,callback=process.fac_scram,fg_bg=hzd_fg_bg}
local ack_a = HazardButton{parent=main,x=16,y=1,text="ACK \x13",accent=colors.orange,dis_colors=dis_colors,callback=process.fac_ack_alarms,fg_bg=hzd_fg_bg}
facility.scram_ack = scram.on_response
facility.ack_alarms_ack = ack_a.on_response
local all_ok = IndicatorLight{parent=main,y=5,label="Unit Systems Online",colors=cpair(colors.green,colors.red)}
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=cpair(colors.green,colors.gray)}
local rad_mon = TriIndicatorLight{parent=main,label="Radiation Monitor",c1=colors.gray,c2=colors.yellow,c3=colors.green}
facility.ps.subscribe("all_sys_ok", all_ok.update)
facility.induction_ps_tbl[1].subscribe("computed_status", function (status) ind_mat.update(status > 1) end)
facility.ps.subscribe("rad_computed_status", rad_mon.update)
main.line_break()
local auto_ready = IndicatorLight{parent=main,label="Configured Units Ready",colors=cpair(colors.green,colors.red)}
local auto_act = IndicatorLight{parent=main,label="Process Active",colors=cpair(colors.green,colors.gray)}
local auto_ramp = IndicatorLight{parent=main,label="Process Ramping",colors=cpair(colors.white,colors.gray),flash=true,period=period.BLINK_250_MS}
local auto_sat = IndicatorLight{parent=main,label="Min/Max Burn Rate",colors=cpair(colors.yellow,colors.gray)}
facility.ps.subscribe("auto_ready", auto_ready.update)
facility.ps.subscribe("auto_active", auto_act.update)
facility.ps.subscribe("auto_ramping", auto_ramp.update)
facility.ps.subscribe("auto_saturated", auto_sat.update)
main.line_break()
local auto_scram = IndicatorLight{parent=main,label="Automatic SCRAM",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local matrix_dc = IndicatorLight{parent=main,label="Matrix Disconnected",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
local matrix_fill = IndicatorLight{parent=main,label="Matrix Charge High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_500_MS}
local unit_crit = IndicatorLight{parent=main,label="Unit Critical Alarm",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local fac_rad_h = IndicatorLight{parent=main,label="Facility Radiation High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local gen_fault = IndicatorLight{parent=main,label="Gen. Control Fault",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
facility.ps.subscribe("auto_scram", auto_scram.update)
facility.ps.subscribe("as_matrix_dc", matrix_dc.update)
facility.ps.subscribe("as_matrix_fill", matrix_fill.update)
facility.ps.subscribe("as_crit_alarm", unit_crit.update)
facility.ps.subscribe("as_radiation", fac_rad_h.update)
facility.ps.subscribe("as_gen_fault", gen_fault.update)
TextBox{parent=main,y=23,text="Radiation",height=1,width=13,fg_bg=style.label}
local radiation = RadIndicator{parent=main,label="",format="%9.3f",lu_colors=lu_cpair,width=13,fg_bg=bw_fg_bg}
facility.ps.subscribe("radiation", radiation.update)
TextBox{parent=main,x=15,y=23,text="Linked RTUs",height=1,width=11,fg_bg=style.label}
local rtu_count = DataIndicator{parent=main,x=15,y=24,label="",format="%11d",value=0,lu_colors=lu_cpair,width=11,fg_bg=bw_fg_bg}
facility.ps.subscribe("rtu_count", rtu_count.update)
---------------------
-- process control --
---------------------
local proc = Div{parent=main,width=78,height=24,x=27,y=1}
-----------------------------
-- process control targets --
-----------------------------
local targets = Div{parent=proc,width=31,height=24,x=1,y=1}
local burn_tag = Div{parent=targets,x=1,y=1,width=8,height=4,fg_bg=cpair(colors.black,colors.purple)}
TextBox{parent=burn_tag,x=2,y=2,text="Burn Target",width=7,height=2}
local burn_target = Div{parent=targets,x=9,y=1,width=23,height=3,fg_bg=cpair(colors.gray,colors.white)}
local b_target = SpinboxNumeric{parent=burn_target,x=11,y=1,whole_num_precision=4,fractional_precision=1,min=0.1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
TextBox{parent=burn_target,x=18,y=2,text="mB/t"}
local burn_sum = DataIndicator{parent=targets,x=9,y=4,label="",format="%18.1f",value=0,unit="mB/t",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_burn_target", b_target.set_value)
facility.ps.subscribe("burn_sum", burn_sum.update)
local chg_tag = Div{parent=targets,x=1,y=6,width=8,height=4,fg_bg=cpair(colors.black,colors.purple)}
TextBox{parent=chg_tag,x=2,y=2,text="Charge Target",width=7,height=2}
local chg_target = Div{parent=targets,x=9,y=6,width=23,height=3,fg_bg=cpair(colors.gray,colors.white)}
local c_target = SpinboxNumeric{parent=chg_target,x=2,y=1,whole_num_precision=15,fractional_precision=0,min=0,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
TextBox{parent=chg_target,x=18,y=2,text="MFE"}
local cur_charge = DataIndicator{parent=targets,x=9,y=9,label="",format="%19d",value=0,unit="MFE",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_charge_target", c_target.set_value)
facility.induction_ps_tbl[1].subscribe("energy", function (j) cur_charge.update(util.joules_to_fe(j) / 1000000) end)
local gen_tag = Div{parent=targets,x=1,y=11,width=8,height=4,fg_bg=cpair(colors.black,colors.purple)}
TextBox{parent=gen_tag,x=2,y=2,text="Gen. Target",width=7,height=2}
local gen_target = Div{parent=targets,x=9,y=11,width=23,height=3,fg_bg=cpair(colors.gray,colors.white)}
local g_target = SpinboxNumeric{parent=gen_target,x=8,y=1,whole_num_precision=9,fractional_precision=0,min=0,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
TextBox{parent=gen_target,x=18,y=2,text="kFE/t"}
local cur_gen = DataIndicator{parent=targets,x=9,y=14,label="",format="%17d",value=0,unit="kFE/t",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_gen_target", g_target.set_value)
facility.induction_ps_tbl[1].subscribe("last_input", function (j) cur_gen.update(util.round(util.joules_to_fe(j) / 1000)) end)
-----------------
-- unit limits --
-----------------
local limit_div = Div{parent=proc,width=21,height=19,x=34,y=6}
local rate_limits = {}
for i = 1, facility.num_units do
local unit = units[i] ---@type ioctl_unit
local _y = ((i - 1) * 5) + 1
local unit_tag = Div{parent=limit_div,x=1,y=_y,width=8,height=4,fg_bg=cpair(colors.black,colors.lightBlue)}
TextBox{parent=unit_tag,x=2,y=2,text="Unit "..i.." Limit",width=7,height=2}
local lim_ctl = Div{parent=limit_div,x=9,y=_y,width=14,height=3,fg_bg=cpair(colors.gray,colors.white)}
rate_limits[i] = SpinboxNumeric{parent=lim_ctl,x=2,y=1,whole_num_precision=4,fractional_precision=1,min=0.1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
TextBox{parent=lim_ctl,x=9,y=2,text="mB/t",width=4,height=1}
unit.unit_ps.subscribe("max_burn", rate_limits[i].set_max)
unit.unit_ps.subscribe("burn_limit", rate_limits[i].set_value)
local cur_burn = DataIndicator{parent=limit_div,x=9,y=_y+3,label="",format="%7.1f",value=0,unit="mB/t",commas=false,lu_colors=cpair(colors.black,colors.black),width=14,fg_bg=cpair(colors.black,colors.brown)}
unit.unit_ps.subscribe("act_burn_rate", cur_burn.update)
end
-------------------
-- unit statuses --
-------------------
local stat_div = Div{parent=proc,width=38,height=19,x=57,y=6}
for i = 1, facility.num_units do
local unit = units[i] ---@type ioctl_unit
local _y = ((i - 1) * 5) + 1
local unit_tag = Div{parent=stat_div,x=1,y=_y,width=8,height=4,fg_bg=cpair(colors.black,colors.lightBlue)}
TextBox{parent=unit_tag,x=2,y=2,text="Unit "..i.." Status",width=7,height=2}
local lights = Div{parent=stat_div,x=9,y=_y,width=12,height=4,fg_bg=bw_fg_bg}
local ready = IndicatorLight{parent=lights,x=2,y=2,label="Ready",colors=cpair(colors.green,colors.gray)}
local degraded = IndicatorLight{parent=lights,x=2,y=3,label="Degraded",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
unit.unit_ps.subscribe("U_AutoReady", ready.update)
unit.unit_ps.subscribe("U_AutoDegraded", degraded.update)
end
-------------------------
-- controls and status --
-------------------------
local ctl_opts = { "Monitored Max Burn", "Combined Burn Rate", "Charge Level", "Generation Rate" }
local mode = RadioButton{parent=proc,x=34,y=1,options=ctl_opts,callback=function()end,radio_colors=cpair(colors.purple,colors.black),radio_bg=colors.gray}
facility.ps.subscribe("process_mode", mode.set_value)
local u_stat = Rectangle{parent=proc,border=border(1,colors.gray,true),thin=true,width=31,height=4,x=1,y=16,fg_bg=bw_fg_bg}
local stat_line_1 = TextBox{parent=u_stat,x=1,y=1,text="UNKNOWN",width=31,height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=bw_fg_bg}
local stat_line_2 = TextBox{parent=u_stat,x=1,y=2,text="awaiting data...",width=31,height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=cpair(colors.gray, colors.white)}
facility.ps.subscribe("status_line_1", stat_line_1.set_value)
facility.ps.subscribe("status_line_2", stat_line_2.set_value)
local auto_controls = Div{parent=proc,x=1,y=20,width=31,height=5,fg_bg=cpair(colors.gray,colors.white)}
-- save the automatic process control configuration without starting
local function _save_cfg()
local limits = {}
for i = 1, #rate_limits do limits[i] = rate_limits[i].get_value() end
process.save(mode.get_value(), b_target.get_value(), c_target.get_value(), g_target.get_value(), limits)
end
-- start automatic control after saving process control settings
local function _start_auto()
_save_cfg()
process.start_auto()
end
local save = HazardButton{parent=auto_controls,x=2,y=2,text="SAVE",accent=colors.purple,dis_colors=dis_colors,callback=_save_cfg,fg_bg=hzd_fg_bg}
local start = HazardButton{parent=auto_controls,x=13,y=2,text="START",accent=colors.lightBlue,dis_colors=dis_colors,callback=_start_auto,fg_bg=hzd_fg_bg}
local stop = HazardButton{parent=auto_controls,x=23,y=2,text="STOP",accent=colors.red,dis_colors=dis_colors,callback=process.stop_auto,fg_bg=hzd_fg_bg}
facility.start_ack = start.on_response
facility.stop_ack = stop.on_response
function facility.save_cfg_ack(ack)
tcd.dispatch(0.2, function () save.on_response(ack) end)
end
facility.ps.subscribe("auto_ready", function (ready)
if ready and (not facility.auto_active) then start.enable() else start.disable() end
end)
facility.ps.subscribe("auto_active", function (active)
if active then
b_target.disable()
c_target.disable()
g_target.disable()
mode.disable()
start.disable()
for i = 1, #rate_limits do
rate_limits[i].disable()
end
else
b_target.enable()
c_target.enable()
g_target.enable()
mode.enable()
if facility.auto_ready then start.enable() end
for i = 1, #rate_limits do
rate_limits[i].enable()
end
end
end)
end
return new_view