cc-mek-scada/supervisor/session/rtu/boiler.lua
2022-05-18 13:49:04 -04:00

189 lines
6.2 KiB
Lua

local comms = require("scada-common.comms")
local log = require("scada-common.log")
local types = require("scada-common.types")
local unit_session = require("supervisor.session.rtu.unit_session")
local boiler = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
BUILD = 1,
STATE = 2,
TANKS = 3
}
local TXN_TAGS = {
"boiler.build",
"boiler.state",
"boiler.tanks",
}
local PERIODICS = {
BUILD = 1000,
STATE = 500,
TANKS = 1000
}
-- create a new boiler rtu session runner
---@param session_id integer
---@param unit_id integer
---@param advert rtu_advertisement
---@param out_queue mqueue
boiler.new = function (session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.BOILER then
log.error("attempt to instantiate boiler RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end
local log_tag = "session.rtu(" .. session_id .. ").boiler(" .. advert.index .. "): "
local self = {
session = unit_session.new(unit_id, advert, out_queue, log_tag, TXN_TAGS),
has_build = false,
periodics = {
next_build_req = 0,
next_state_req = 0,
next_tanks_req = 0,
},
---@class boiler_session_db
db = {
build = {
boil_cap = 0.0,
steam_cap = 0,
water_cap = 0,
hcoolant_cap = 0,
ccoolant_cap = 0,
superheaters = 0,
max_boil_rate = 0.0
},
state = {
temperature = 0.0,
boil_rate = 0.0
},
tanks = {
steam = 0,
steam_need = 0,
steam_fill = 0.0,
water = 0,
water_need = 0,
water_fill = 0.0,
hcool = {}, ---@type tank_fluid
hcool_need = 0,
hcool_fill = 0.0,
ccool = {}, ---@type tank_fluid
ccool_need = 0,
ccool_fill = 0.0
}
}
}
local public = self.session.get()
-- PRIVATE FUNCTIONS --
-- query the build of the device
local _request_build = function ()
-- read input registers 1 through 7 (start = 1, count = 7)
self.session.send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 7 })
end
-- query the state of the device
local _request_state = function ()
-- read input registers 8 through 9 (start = 8, count = 2)
self.session.send_request(TXN_TYPES.STATE, MODBUS_FCODE.READ_INPUT_REGS, { 8, 2 })
end
-- query the tanks of the device
local _request_tanks = function ()
-- read input registers 10 through 21 (start = 10, count = 12)
self.session.send_request(TXN_TYPES.TANKS, MODBUS_FCODE.READ_INPUT_REGS, { 10, 12 })
end
-- PUBLIC FUNCTIONS --
-- handle a packet
---@param m_pkt modbus_frame
public.handle_packet = function (m_pkt)
local txn_type = self.session.try_resolve(m_pkt.txn_id)
if txn_type == false then
-- nothing to do
elseif txn_type == TXN_TYPES.BUILD then
-- build response
-- load in data if correct length
if m_pkt.length == 7 then
self.db.build.boil_cap = m_pkt.data[1]
self.db.build.steam_cap = m_pkt.data[2]
self.db.build.water_cap = m_pkt.data[3]
self.db.build.hcoolant_cap = m_pkt.data[4]
self.db.build.ccoolant_cap = m_pkt.data[5]
self.db.build.superheaters = m_pkt.data[6]
self.db.build.max_boil_rate = m_pkt.data[7]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.build)")
end
elseif txn_type == TXN_TYPES.STATE then
-- state response
-- load in data if correct length
if m_pkt.length == 2 then
self.db.state.temperature = m_pkt.data[1]
self.db.state.boil_rate = m_pkt.data[2]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.state)")
end
elseif txn_type == TXN_TYPES.TANKS then
-- tanks response
-- load in data if correct length
if m_pkt.length == 12 then
self.db.tanks.steam = m_pkt.data[1]
self.db.tanks.steam_need = m_pkt.data[2]
self.db.tanks.steam_fill = m_pkt.data[3]
self.db.tanks.water = m_pkt.data[4]
self.db.tanks.water_need = m_pkt.data[5]
self.db.tanks.water_fill = m_pkt.data[6]
self.db.tanks.hcool = m_pkt.data[7]
self.db.tanks.hcool_need = m_pkt.data[8]
self.db.tanks.hcool_fill = m_pkt.data[9]
self.db.tanks.ccool = m_pkt.data[10]
self.db.tanks.ccool_need = m_pkt.data[11]
self.db.tanks.ccool_fill = m_pkt.data[12]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.tanks)")
end
elseif txn_type == nil then
log.error(log_tag .. "unknown transaction reply")
else
log.error(log_tag .. "unknown transaction type " .. txn_type)
end
end
-- update this runner
---@param time_now integer milliseconds
public.update = function (time_now)
if not self.periodics.has_build and self.periodics.next_build_req <= time_now then
_request_build()
self.periodics.next_build_req = time_now + PERIODICS.BUILD
end
if self.periodics.next_state_req <= time_now then
_request_state()
self.periodics.next_state_req = time_now + PERIODICS.STATE
end
if self.periodics.next_tanks_req <= time_now then
_request_tanks()
self.periodics.next_tanks_req = time_now + PERIODICS.TANKS
end
end
-- get the unit session database
public.get_db = function () return self.db end
return public
end
return boiler