cc-mek-scada/reactor-plc/startup.lua

222 lines
6.8 KiB
Lua

--
-- Reactor Programmable Logic Controller
--
require("/initenv").init_env()
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local ppm = require("scada-common.ppm")
local util = require("scada-common.util")
local config = require("reactor-plc.config")
local plc = require("reactor-plc.plc")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "beta-v0.9.8"
local print = util.print
local println = util.println
local print_ts = util.print_ts
local println_ts = util.println_ts
----------------------------------------
-- config validation
----------------------------------------
local cfv = util.new_validator()
cfv.assert_type_bool(config.NETWORKED)
cfv.assert_type_int(config.REACTOR_ID)
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
assert(cfv.valid(), "bad config file: missing/invalid fields")
----------------------------------------
-- log init
----------------------------------------
log.init(config.LOG_PATH, config.LOG_MODE)
log.info("========================================")
log.info("BOOTING reactor-plc.startup " .. R_PLC_VERSION)
log.info("========================================")
println(">> Reactor PLC " .. R_PLC_VERSION .. " <<")
crash.set_env("plc", R_PLC_VERSION)
----------------------------------------
-- main application
----------------------------------------
local function main()
----------------------------------------
-- startup
----------------------------------------
-- mount connected devices
ppm.mount_all()
-- shared memory across threads
---@class plc_shared_memory
local __shared_memory = {
-- networked setting
networked = config.NETWORKED, ---@type boolean
-- PLC system state flags
---@class plc_state
plc_state = {
init_ok = true,
shutdown = false,
degraded = false,
reactor_formed = true,
no_reactor = false,
no_modem = false
},
-- control setpoints
---@class setpoints
setpoints = {
burn_rate_en = false,
burn_rate = 0.0
},
-- core PLC devices
plc_dev = {
reactor = ppm.get_fission_reactor(),
modem = ppm.get_wireless_modem()
},
-- system objects
plc_sys = {
rps = nil, ---@type rps
plc_comms = nil, ---@type plc_comms
conn_watchdog = nil ---@type watchdog
},
-- message queues
q = {
mq_rps = mqueue.new(),
mq_comms_tx = mqueue.new(),
mq_comms_rx = mqueue.new()
}
}
local smem_dev = __shared_memory.plc_dev
local smem_sys = __shared_memory.plc_sys
local plc_state = __shared_memory.plc_state
-- we need a reactor, can at least do some things even if it isn't formed though
if smem_dev.reactor == nil then
println("boot> fission reactor not found");
log.warning("no reactor on startup")
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_reactor = true
elseif not smem_dev.reactor.isFormed() then
println("boot> fission reactor not formed");
log.warning("reactor logic adapter present, but reactor is not formed")
plc_state.degraded = true
plc_state.reactor_formed = false
end
-- modem is required if networked
if __shared_memory.networked and smem_dev.modem == nil then
println("boot> wireless modem not found")
log.warning("no wireless modem on startup")
-- scram reactor if present and enabled
if (smem_dev.reactor ~= nil) and plc_state.reactor_formed and smem_dev.reactor.getStatus() then
smem_dev.reactor.scram()
end
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_modem = true
end
-- PLC init
---
--- EVENT_CONSUMER: this function consumes events
local function init()
if plc_state.init_ok then
-- just booting up, no fission allowed (neutrons stay put thanks)
if plc_state.reactor_formed and smem_dev.reactor.getStatus() then
smem_dev.reactor.scram()
end
-- init reactor protection system
smem_sys.rps = plc.rps_init(smem_dev.reactor, plc_state.reactor_formed)
log.debug("init> rps init")
if __shared_memory.networked then
-- comms watchdog, 3 second timeout
smem_sys.conn_watchdog = util.new_watchdog(3)
log.debug("init> conn watchdog started")
-- start comms
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
log.debug("init> comms init")
else
println("boot> starting in offline mode")
log.debug("init> running without networking")
end
util.push_event("clock_start")
println("boot> completed")
log.debug("init> boot completed")
else
println("boot> system in degraded state, awaiting devices...")
log.warning("init> booted in a degraded state, awaiting peripheral connections...")
end
end
----------------------------------------
-- start system
----------------------------------------
-- initialize PLC
init()
-- init threads
local main_thread = threads.thread__main(__shared_memory, init)
local rps_thread = threads.thread__rps(__shared_memory)
if __shared_memory.networked then
-- init comms threads
local comms_thread_tx = threads.thread__comms_tx(__shared_memory)
local comms_thread_rx = threads.thread__comms_rx(__shared_memory)
-- setpoint control only needed when networked
local sp_ctrl_thread = threads.thread__setpoint_control(__shared_memory)
-- run threads
parallel.waitForAll(main_thread.p_exec, rps_thread.p_exec, comms_thread_tx.p_exec, comms_thread_rx.p_exec, sp_ctrl_thread.p_exec)
if plc_state.init_ok then
-- send status one last time after RPS shutdown
smem_sys.plc_comms.send_status(plc_state.no_reactor, plc_state.reactor_formed)
smem_sys.plc_comms.send_rps_status()
-- close connection
smem_sys.plc_comms.close()
end
else
-- run threads, excluding comms
parallel.waitForAll(main_thread.p_exec, rps_thread.p_exec)
end
println_ts("exited")
log.info("exited")
end
if not xpcall(main, crash.handler) then crash.exit() end