local types = require("scada-common.types")
local util = require("scada-common.util")
local log = require("scada-common.log")
local unit = {}
local TRI_FAIL = types.TRI_FAIL
local DUMPING_MODE = types.DUMPING_MODE
local DT_KEYS = {
ReactorTemp = "RTP",
ReactorFuel = "RFL",
ReactorWaste = "RWS",
ReactorCCool = "RCC",
ReactorHCool = "RHC",
BoilerWater = "BWR",
BoilerSteam = "BST",
BoilerCCool = "BCC",
BoilerHCool = "BHC",
TurbineSteam = "TST",
TurbinePower = "TPR"
}
-- create a new reactor unit
---@param for_reactor integer reactor unit number
---@param num_boilers integer number of boilers expected
---@param num_turbines integer number of turbines expected
function unit.new(for_reactor, num_boilers, num_turbines)
local self = {
r_id = for_reactor,
plc_s = nil, ---@class plc_session_struct
plc_i = nil, ---@class plc_session
counts = { boilers = num_boilers, turbines = num_turbines },
turbines = {},
boilers = {},
redstone = {},
deltas = {},
last_heartbeat = 0,
db = {
---@class annunciator
annunciator = {
-- reactor
PLCOnline = false,
PLCHeartbeat = false, -- alternate true/false to blink, each time there is a keep_alive
ReactorSCRAM = false,
ManualReactorSCRAM = false,
AutoReactorSCRAM = false,
RCPTrip = false,
RCSFlowLow = false,
ReactorTempHigh = false,
ReactorHighDeltaT = false,
FuelInputRateLow = false,
WasteLineOcclusion = false,
HighStartupRate = false,
-- boiler
BoilerOnline = {},
HeatingRateLow = {},
BoilRateMismatch = false,
CoolantFeedMismatch = false,
-- turbine
TurbineOnline = {},
SteamFeedMismatch = false,
MaxWaterReturnFeed = false,
SteamDumpOpen = {},
TurbineOverSpeed = {},
TurbineTrip = {}
}
}
}
-- init boiler table fields
for _ = 1, num_boilers do
table.insert(self.db.annunciator.BoilerOnline, false)
table.insert(self.db.annunciator.HeatingRateLow, false)
end
-- init turbine table fields
for _ = 1, num_turbines do
table.insert(self.db.annunciator.TurbineOnline, false)
table.insert(self.db.annunciator.SteamDumpOpen, TRI_FAIL.OK)
table.insert(self.db.annunciator.TurbineOverSpeed, false)
table.insert(self.db.annunciator.TurbineTrip, false)
end
---@class reactor_unit
local public = {}
-- PRIVATE FUNCTIONS --
-- compute a change with respect to time of the given value
---@param key string value key
---@param value number value
---@param time number timestamp for value
local function _compute_dt(key, value, time)
if self.deltas[key] then
local data = self.deltas[key]
if time > data.last_t then
data.dt = (value - data.last_v) / (time - data.last_t)
data.last_v = value
data.last_t = time
end
else
self.deltas[key] = {
last_t = time,
last_v = value,
dt = 0.0
}
end
end
-- clear a delta
---@param key string value key
local function _reset_dt(key) self.deltas[key] = nil end
-- get the delta t of a value
---@param key string value key
---@return number
local function _get_dt(key)
if self.deltas[key] then
return self.deltas[key].dt
else
return 0.0
end
end
-- update all delta computations
local function _dt__compute_all()
if self.plc_s ~= nil then
local plc_db = self.plc_i.get_db()
local last_update_s = plc_db.last_status_update / 1000.0
_compute_dt(DT_KEYS.ReactorTemp, plc_db.mek_status.temp, last_update_s)
_compute_dt(DT_KEYS.ReactorFuel, plc_db.mek_status.fuel, last_update_s)
_compute_dt(DT_KEYS.ReactorWaste, plc_db.mek_status.waste, last_update_s)
_compute_dt(DT_KEYS.ReactorCCool, plc_db.mek_status.ccool_amnt, last_update_s)
_compute_dt(DT_KEYS.ReactorHCool, plc_db.mek_status.hcool_amnt, last_update_s)
end
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
local db = boiler.get_db() ---@type boilerv_session_db
local last_update_s = db.tanks.last_update / 1000.0
_compute_dt(DT_KEYS.BoilerWater .. boiler.get_device_idx(), db.tanks.water.amount, last_update_s)
_compute_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx(), db.tanks.steam.amount, last_update_s)
_compute_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx(), db.tanks.ccool.amount, last_update_s)
_compute_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx(), db.tanks.hcool.amount, last_update_s)
end
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
local db = turbine.get_db() ---@type turbinev_session_db
local last_update_s = db.tanks.last_update / 1000.0
_compute_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx(), db.tanks.steam.amount, last_update_s)
---@todo unused currently?
_compute_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx(), db.tanks.energy, last_update_s)
end
end
-- update the annunciator
local function _update_annunciator()
-- update deltas
_dt__compute_all()
-- variables for boiler, or reactor if no boilers used
local total_boil_rate = 0.0
-------------
-- REACTOR --
-------------
-- check PLC status
self.db.annunciator.PLCOnline = (self.plc_s ~= nil) and (self.plc_s.open)
if self.plc_s ~= nil then
local plc_db = self.plc_i.get_db()
-- heartbeat blink about every second
if self.last_heartbeat + 1000 < plc_db.last_status_update then
self.db.annunciator.PLCHeartbeat = not self.db.annunciator.PLCHeartbeat
self.last_heartbeat = plc_db.last_status_update
end
-- update other annunciator fields
self.db.annunciator.ReactorSCRAM = plc_db.rps_tripped
self.db.annunciator.ManualReactorSCRAM = plc_db.rps_trip_cause == types.rps_status_t.manual
self.db.annunciator.AutoReactorSCRAM = plc_db.rps_trip_cause == types.rps_status_t.automatic
self.db.annunciator.RCPTrip = plc_db.rps_tripped and (plc_db.rps_status.ex_hcool or plc_db.rps_status.no_cool)
self.db.annunciator.RCSFlowLow = plc_db.mek_status.ccool_fill < 0.75 or plc_db.mek_status.hcool_fill > 0.25
self.db.annunciator.ReactorTempHigh = plc_db.mek_status.temp > 1000
self.db.annunciator.ReactorHighDeltaT = _get_dt(DT_KEYS.ReactorTemp) > 100
self.db.annunciator.FuelInputRateLow = _get_dt(DT_KEYS.ReactorFuel) < -1.0 or plc_db.mek_status.fuel_fill <= 0.01
self.db.annunciator.WasteLineOcclusion = _get_dt(DT_KEYS.ReactorWaste) > 1.0 or plc_db.mek_status.waste_fill >= 0.85
---@todo this is dependent on setup, i.e. how much coolant is buffered and the turbine setup
self.db.annunciator.HighStartupRate = not plc_db.mek_status.status and plc_db.mek_status.burn_rate > 40
-- if no boilers, use reactor heating rate to check for boil rate mismatch
if self.counts.boilers == 0 then
total_boil_rate = plc_db.mek_status.heating_rate
end
end
-------------
-- BOILERS --
-------------
-- clear boiler online flags
for i = 1, self.counts.boilers do self.db.annunciator.BoilerOnline[i] = false end
-- aggregated statistics
local boiler_steam_dt_sum = 0.0
local boiler_water_dt_sum = 0.0
if self.counts.boilers > 0 then
-- go through boilers for stats and online
for i = 1, #self.boilers do
local session = self.boilers[i] ---@type unit_session
local boiler = session.get_db() ---@type boilerv_session_db
total_boil_rate = total_boil_rate + boiler.state.boil_rate
boiler_steam_dt_sum = _get_dt(DT_KEYS.BoilerSteam .. self.boilers[i].get_device_idx())
boiler_water_dt_sum = _get_dt(DT_KEYS.BoilerWater .. self.boilers[i].get_device_idx())
self.db.annunciator.BoilerOnline[session.get_device_idx()] = true
end
-- check heating rate low
if self.plc_s ~= nil and #self.boilers > 0 then
local r_db = self.plc_i.get_db()
-- check for inactive boilers while reactor is active
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
local idx = boiler.get_device_idx()
local db = boiler.get_db() ---@type boilerv_session_db
if r_db.mek_status.status then
self.db.annunciator.HeatingRateLow[idx] = db.state.boil_rate == 0
else
self.db.annunciator.HeatingRateLow[idx] = false
end
end
end
else
boiler_steam_dt_sum = _get_dt(DT_KEYS.ReactorHCool)
boiler_water_dt_sum = _get_dt(DT_KEYS.ReactorCCool)
end
---------------------------
-- COOLANT FEED MISMATCH --
---------------------------
-- check coolant feed mismatch if using boilers, otherwise calculate with reactor
local cfmismatch = false
if self.counts.boilers > 0 then
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
local idx = boiler.get_device_idx()
local db = boiler.get_db() ---@type boilerv_session_db
local gaining_hc = _get_dt(DT_KEYS.BoilerHCool .. idx) > 10.0 or db.tanks.hcool_fill == 1
-- gaining heated coolant
cfmismatch = cfmismatch or gaining_hc
-- losing cooled coolant
cfmismatch = cfmismatch or _get_dt(DT_KEYS.BoilerCCool .. idx) < -10.0 or (gaining_hc and db.tanks.ccool_fill == 0)
end
elseif self.plc_s ~= nil then
local r_db = self.plc_i.get_db()
local gaining_hc = _get_dt(DT_KEYS.ReactorHCool) > 10.0 or r_db.mek_status.hcool_fill == 1
-- gaining heated coolant (steam)
cfmismatch = cfmismatch or gaining_hc
-- losing cooled coolant (water)
cfmismatch = cfmismatch or _get_dt(DT_KEYS.ReactorCCool) < -10.0 or (gaining_hc and r_db.mek_status.ccool_fill == 0)
end
self.db.annunciator.CoolantFeedMismatch = cfmismatch
--------------
-- TURBINES --
--------------
-- clear turbine online flags
for i = 1, self.counts.turbines do self.db.annunciator.TurbineOnline[i] = false end
-- aggregated statistics
local total_flow_rate = 0
local total_input_rate = 0
local max_water_return_rate = 0
-- go through turbines for stats and online
for i = 1, #self.turbines do
local session = self.turbines[i] ---@type unit_session
local turbine = session.get_db() ---@type turbinev_session_db
total_flow_rate = total_flow_rate + turbine.state.flow_rate
total_input_rate = total_input_rate + turbine.state.steam_input_rate
max_water_return_rate = max_water_return_rate + turbine.build.max_water_output
self.db.annunciator.TurbineOnline[session.get_device_idx()] = true
end
-- check for boil rate mismatch (either between reactor and turbine or boiler and turbine)
self.db.annunciator.BoilRateMismatch = math.abs(total_boil_rate - total_input_rate) > 4
-- check for steam feed mismatch and max return rate
local sfmismatch = math.abs(total_flow_rate - total_input_rate) > 10
sfmismatch = sfmismatch or boiler_steam_dt_sum > 2.0 or boiler_water_dt_sum < -2.0
self.db.annunciator.SteamFeedMismatch = sfmismatch
self.db.annunciator.MaxWaterReturnFeed = max_water_return_rate == total_flow_rate and total_flow_rate ~= 0
-- check if steam dumps are open
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
local db = turbine.get_db() ---@type turbinev_session_db
local idx = turbine.get_device_idx()
if db.state.dumping_mode == DUMPING_MODE.IDLE then
self.db.annunciator.SteamDumpOpen[idx] = TRI_FAIL.OK
elseif db.state.dumping_mode == DUMPING_MODE.DUMPING_EXCESS then
self.db.annunciator.SteamDumpOpen[idx] = TRI_FAIL.PARTIAL
else
self.db.annunciator.SteamDumpOpen[idx] = TRI_FAIL.FULL
end
end
-- check if turbines are at max speed but not keeping up
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
local db = turbine.get_db() ---@type turbinev_session_db
local idx = turbine.get_device_idx()
self.db.annunciator.TurbineOverSpeed[idx] = (db.state.flow_rate == db.build.max_flow_rate) and (_get_dt(DT_KEYS.TurbineSteam .. idx) > 0.0)
end
--[[
Turbine Trip
a turbine trip is when the turbine stops, which means we are no longer receiving water and lose the ability to cool.
this can be identified by these conditions:
- the current flow rate is 0 mB/t and it should not be
- can initially catch this by detecting a 0 flow rate with a non-zero input rate, but eventually the steam will fill up
- can later identified by presence of steam in tank with a 0 flow rate
]]--
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
local db = turbine.get_db() ---@type turbinev_session_db
local has_steam = db.state.steam_input_rate > 0 or db.tanks.steam_fill > 0.01
self.db.annunciator.TurbineTrip[turbine.get_device_idx()] = has_steam and db.state.flow_rate == 0
end
end
-- unlink disconnected units
---@param sessions table
local function _unlink_disconnected_units(sessions)
util.filter_table(sessions, function (u) return u.is_connected() end)
end
-- PUBLIC FUNCTIONS --
-- ADD/LINK DEVICES --
-- link the PLC
---@param plc_session plc_session_struct
function public.link_plc_session(plc_session)
self.plc_s = plc_session
self.plc_i = plc_session.instance
-- reset deltas
_reset_dt(DT_KEYS.ReactorTemp)
_reset_dt(DT_KEYS.ReactorFuel)
_reset_dt(DT_KEYS.ReactorWaste)
_reset_dt(DT_KEYS.ReactorCCool)
_reset_dt(DT_KEYS.ReactorHCool)
end
-- link a turbine RTU session
---@param turbine unit_session
function public.add_turbine(turbine)
if #self.turbines < num_turbines and turbine.get_device_idx() <= num_turbines then
table.insert(self.turbines, turbine)
-- reset deltas
_reset_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx())
_reset_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx())
return true
else
return false
end
end
-- link a boiler RTU session
---@param boiler unit_session
function public.add_boiler(boiler)
if #self.boilers < num_boilers and boiler.get_device_idx() <= num_boilers then
table.insert(self.boilers, boiler)
-- reset deltas
_reset_dt(DT_KEYS.BoilerWater .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx())
return true
else
return false
end
end
-- link a redstone RTU capability
function public.add_redstone(field, accessor)
-- ensure field exists
if self.redstone[field] == nil then
self.redstone[field] = {}
end
-- insert into list
table.insert(self.redstone[field], accessor)
end
-- purge devices associated with the given RTU session ID
---@param session integer RTU session ID
function public.purge_rtu_devices(session)
util.filter_table(self.turbines, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.boilers, function (s) return s.get_session_id() ~= session end)
util.filter_table(self.redstone, function (s) return s.get_session_id() ~= session end)
end
-- UPDATE SESSION --
-- update (iterate) this unit
function public.update()
-- unlink PLC if session was closed
if self.plc_s ~= nil and not self.plc_s.open then
self.plc_s = nil
end
-- unlink RTU unit sessions if they are closed
_unlink_disconnected_units(self.boilers)
_unlink_disconnected_units(self.turbines)
-- update annunciator logic
_update_annunciator()
end
-- READ STATES/PROPERTIES --
-- get build properties of all machines
function public.get_build()
local build = {}
if self.plc_s ~= nil then
build.reactor = self.plc_i.get_struct()
end
build.boilers = {}
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
build.boilers[boiler.get_device_idx()] = { boiler.get_db().formed, boiler.get_db().build }
end
build.turbines = {}
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
build.turbines[turbine.get_device_idx()] = { turbine.get_db().formed, turbine.get_db().build }
end
return build
end
-- get reactor status
function public.get_reactor_status()
local status = {}
if self.plc_s ~= nil then
local reactor = self.plc_i
status = { reactor.get_status(), reactor.get_rps(), reactor.get_general_status() }
end
return status
end
-- get RTU statuses
function public.get_rtu_statuses()
local status = {}
-- status of boilers (including tanks)
status.boilers = {}
for i = 1, #self.boilers do
local boiler = self.boilers[i] ---@type unit_session
status.boilers[boiler.get_device_idx()] = {
boiler.is_faulted(),
boiler.get_db().formed,
boiler.get_db().state,
boiler.get_db().tanks
}
end
-- status of turbines (including tanks)
status.turbines = {}
for i = 1, #self.turbines do
local turbine = self.turbines[i] ---@type unit_session
status.turbines[turbine.get_device_idx()] = {
turbine.is_faulted(),
turbine.get_db().formed,
turbine.get_db().state,
turbine.get_db().tanks
}
end
---@todo other RTU statuses
return status
end
-- get the annunciator status
function public.get_annunciator() return self.db.annunciator end
-- get the reactor ID
function public.get_id() return self.r_id end
return public
end
return unit