cc-mek-scada/supervisor/startup.lua

152 lines
4.7 KiB
Lua

--
-- Nuclear Generation Facility SCADA Supervisor
--
require("/initenv").init_env()
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local util = require("scada-common.util")
local svsessions = require("supervisor.session.svsessions")
local config = require("supervisor.config")
local supervisor = require("supervisor.supervisor")
local SUPERVISOR_VERSION = "beta-v0.5.10"
local print = util.print
local println = util.println
local print_ts = util.print_ts
local println_ts = util.println_ts
----------------------------------------
-- config validation
----------------------------------------
local cfv = util.new_validator()
cfv.assert_port(config.SCADA_DEV_LISTEN)
cfv.assert_port(config.SCADA_SV_LISTEN)
cfv.assert_type_int(config.NUM_REACTORS)
cfv.assert_type_table(config.REACTOR_COOLING)
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
assert(cfv.valid(), "bad config file: missing/invalid fields")
for i = 1, config.NUM_REACTORS do
cfv.assert_type_table(config.REACTOR_COOLING[i])
assert(cfv.valid(), "missing cooling entry for reactor " .. i)
cfv.assert_type_int(config.REACTOR_COOLING[i].BOILERS)
cfv.assert_type_int(config.REACTOR_COOLING[i].TURBINES)
assert(cfv.valid(), "missing boilers/turbines for reactor " .. i)
cfv.assert_min(config.REACTOR_COOLING[i].BOILERS, 0)
cfv.assert_min(config.REACTOR_COOLING[i].TURBINES, 1)
assert(cfv.valid(), "bad number of boilers/turbines for reactor " .. i)
end
----------------------------------------
-- log init
----------------------------------------
log.init(config.LOG_PATH, config.LOG_MODE)
log.info("========================================")
log.info("BOOTING supervisor.startup " .. SUPERVISOR_VERSION)
log.info("========================================")
println(">> SCADA Supervisor " .. SUPERVISOR_VERSION .. " <<")
----------------------------------------
-- startup
----------------------------------------
-- mount connected devices
ppm.mount_all()
local modem = ppm.get_wireless_modem()
if modem == nil then
println("boot> wireless modem not found")
log.fatal("no wireless modem on startup")
return
end
-- start comms, open all channels
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, config.NUM_REACTORS, config.REACTOR_COOLING, modem,
config.SCADA_DEV_LISTEN, config.SCADA_SV_LISTEN)
-- base loop clock (6.67Hz, 3 ticks)
local MAIN_CLOCK = 0.15
local loop_clock = util.new_clock(MAIN_CLOCK)
-- start clock
loop_clock.start()
-- event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
-- handle event
if event == "peripheral_detach" then
local type, device = ppm.handle_unmount(param1)
if type ~= nil and device ~= nil then
if type == "modem" then
-- we only care if this is our wireless modem
if device == modem then
println_ts("wireless modem disconnected!")
log.error("comms modem disconnected!")
else
log.warning("non-comms modem disconnected")
end
end
end
elseif event == "peripheral" then
local type, device = ppm.mount(param1)
if type ~= nil and device ~= nil then
if type == "modem" then
if device.isWireless() then
-- reconnected modem
modem = device
superv_comms.reconnect_modem(modem)
println_ts("wireless modem reconnected.")
log.info("comms modem reconnected.")
else
log.info("wired modem reconnected.")
end
end
end
elseif event == "timer" and loop_clock.is_clock(param1) then
-- main loop tick
-- iterate sessions
svsessions.iterate_all()
-- free any closed sessions
svsessions.free_all_closed()
loop_clock.start()
elseif event == "timer" then
-- a non-clock timer event, check watchdogs
svsessions.check_all_watchdogs(param1)
elseif event == "modem_message" then
-- got a packet
local packet = superv_comms.parse_packet(param1, param2, param3, param4, param5)
superv_comms.handle_packet(packet)
end
-- check for termination request
if event == "terminate" or ppm.should_terminate() then
println_ts("closing sessions...")
log.info("terminate requested, closing sessions...")
svsessions.close_all()
log.info("sessions closed")
break
end
end
println_ts("exited")
log.info("exited")