-- Reactor PLC Front Panel GUI
|
|
--
|
|
|
|
local types = require("scada-common.types")
|
|
local util = require("scada-common.util")
|
|
|
|
local databus = require("reactor-plc.databus")
|
|
local plc = require("reactor-plc.plc")
|
|
|
|
local style = require("reactor-plc.panel.style")
|
|
|
|
local core = require("graphics.core")
|
|
local flasher = require("graphics.flasher")
|
|
local themes = require("graphics.themes")
|
|
|
|
local Div = require("graphics.elements.div")
|
|
local Rectangle = require("graphics.elements.rectangle")
|
|
local TextBox = require("graphics.elements.textbox")
|
|
|
|
local PushButton = require("graphics.elements.controls.push_button")
|
|
|
|
local LED = require("graphics.elements.indicators.led")
|
|
local LEDPair = require("graphics.elements.indicators.ledpair")
|
|
local RGBLED = require("graphics.elements.indicators.ledrgb")
|
|
|
|
local LINK_STATE = types.PANEL_LINK_STATE
|
|
|
|
local ALIGN = core.ALIGN
|
|
|
|
local cpair = core.cpair
|
|
local border = core.border
|
|
|
|
local ind_grn = style.ind_grn
|
|
local ind_red = style.ind_red
|
|
|
|
-- create new front panel view
|
|
---@param panel graphics_element main displaybox
|
|
local function init(panel)
|
|
local s_hi_box = style.theme.highlight_box
|
|
|
|
local disabled_fg = style.fp.disabled_fg
|
|
|
|
local header = TextBox{parent=panel,y=1,text="FISSION REACTOR PLC - UNIT ?",alignment=ALIGN.CENTER,height=1,fg_bg=style.theme.header}
|
|
header.register(databus.ps, "unit_id", function (id) header.set_value(util.c("FISSION REACTOR PLC - UNIT ", id)) end)
|
|
|
|
--
|
|
-- system indicators
|
|
--
|
|
|
|
local system = Div{parent=panel,width=14,height=18,x=2,y=3}
|
|
|
|
local init_ok = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
|
|
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=ind_grn}
|
|
system.line_break()
|
|
|
|
init_ok.register(databus.ps, "init_ok", init_ok.update)
|
|
heartbeat.register(databus.ps, "heartbeat", heartbeat.update)
|
|
|
|
local reactor = LEDPair{parent=system,label="REACTOR",off=colors.red,c1=colors.yellow,c2=colors.green}
|
|
local modem = LED{parent=system,label="MODEM",colors=ind_grn}
|
|
|
|
if not style.colorblind then
|
|
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,colors.gray}}
|
|
network.update(types.PANEL_LINK_STATE.DISCONNECTED)
|
|
network.register(databus.ps, "link_state", network.update)
|
|
else
|
|
local nt_lnk = RGBLED{parent=system,label="NT LINKED",colors={colors.red_off,colors.red,colors.green}}
|
|
local nt_ver = RGBLED{parent=system,label="NT VERSION",colors={colors.red_off,colors.red,colors.green}}
|
|
local nt_col = LED{parent=system,label="NT COLLISION",colors=ind_red}
|
|
|
|
nt_lnk.register(databus.ps, "link_state", function (state)
|
|
local value = 2
|
|
|
|
if state == LINK_STATE.DISCONNECTED then
|
|
value = 1
|
|
elseif state == LINK_STATE.LINKED then
|
|
value = 3
|
|
end
|
|
|
|
nt_lnk.update(value)
|
|
end)
|
|
|
|
nt_ver.register(databus.ps, "link_state", function (state)
|
|
local value = 3
|
|
|
|
if state == LINK_STATE.BAD_VERSION then
|
|
value = 2
|
|
elseif state == LINK_STATE.DISCONNECTED then
|
|
value = 1
|
|
end
|
|
|
|
nt_ver.update(value)
|
|
end)
|
|
|
|
nt_col.register(databus.ps, "link_state", function (state) nt_col.update(state == LINK_STATE.COLLISION) end)
|
|
end
|
|
|
|
system.line_break()
|
|
|
|
reactor.register(databus.ps, "reactor_dev_state", reactor.update)
|
|
modem.register(databus.ps, "has_modem", modem.update)
|
|
|
|
local rt_main = LED{parent=system,label="RT MAIN",colors=ind_grn}
|
|
local rt_rps = LED{parent=system,label="RT RPS",colors=ind_grn}
|
|
local rt_cmtx = LED{parent=system,label="RT COMMS TX",colors=ind_grn}
|
|
local rt_cmrx = LED{parent=system,label="RT COMMS RX",colors=ind_grn}
|
|
local rt_sctl = LED{parent=system,label="RT SPCTL",colors=ind_grn}
|
|
system.line_break()
|
|
|
|
rt_main.register(databus.ps, "routine__main", rt_main.update)
|
|
rt_rps.register(databus.ps, "routine__rps", rt_rps.update)
|
|
rt_cmtx.register(databus.ps, "routine__comms_tx", rt_cmtx.update)
|
|
rt_cmrx.register(databus.ps, "routine__comms_rx", rt_cmrx.update)
|
|
rt_sctl.register(databus.ps, "routine__spctl", rt_sctl.update)
|
|
|
|
---@diagnostic disable-next-line: undefined-field
|
|
local comp_id = util.sprintf("(%d)", os.getComputerID())
|
|
TextBox{parent=system,x=9,y=5,width=6,height=1,text=comp_id,fg_bg=disabled_fg}
|
|
|
|
--
|
|
-- status & controls
|
|
--
|
|
|
|
local status = Div{parent=panel,width=19,height=18,x=17,y=3}
|
|
|
|
local active = LED{parent=status,x=2,width=12,label="RCT ACTIVE",colors=ind_grn}
|
|
|
|
-- only show emergency coolant LED if emergency coolant is configured for this device
|
|
if plc.config.EmerCoolEnable then
|
|
local emer_cool = LED{parent=status,x=2,width=14,label="EMER COOLANT",colors=cpair(colors.yellow,colors.yellow_off)}
|
|
emer_cool.register(databus.ps, "emer_cool", emer_cool.update)
|
|
end
|
|
|
|
local status_trip_rct = Rectangle{parent=status,width=20,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
|
|
local status_trip = Div{parent=status_trip_rct,width=18,height=1,fg_bg=s_hi_box}
|
|
local scram = LED{parent=status_trip,width=10,label="RPS TRIP",colors=ind_red,flash=true,period=flasher.PERIOD.BLINK_250_MS}
|
|
|
|
local controls_rct = Rectangle{parent=status,width=17,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
|
|
local controls = Div{parent=controls_rct,width=15,height=1,fg_bg=s_hi_box}
|
|
PushButton{parent=controls,x=1,y=1,min_width=7,text="SCRAM",callback=databus.rps_scram,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.black,colors.red_off)}
|
|
PushButton{parent=controls,x=9,y=1,min_width=7,text="RESET",callback=databus.rps_reset,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.black,colors.yellow_off)}
|
|
|
|
active.register(databus.ps, "reactor_active", active.update)
|
|
scram.register(databus.ps, "rps_scram", scram.update)
|
|
|
|
--
|
|
-- about footer
|
|
--
|
|
|
|
local about = Div{parent=panel,width=15,height=3,x=1,y=18,fg_bg=disabled_fg}
|
|
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00",alignment=ALIGN.LEFT,height=1}
|
|
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00",alignment=ALIGN.LEFT,height=1}
|
|
|
|
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
|
|
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
|
|
|
|
--
|
|
-- rps list
|
|
--
|
|
|
|
local rps = Rectangle{parent=panel,width=16,height=16,x=36,y=3,border=border(1,s_hi_box.bkg),thin=true,fg_bg=s_hi_box}
|
|
local rps_man = LED{parent=rps,label="MANUAL",colors=ind_red}
|
|
local rps_auto = LED{parent=rps,label="AUTOMATIC",colors=ind_red}
|
|
local rps_tmo = LED{parent=rps,label="TIMEOUT",colors=ind_red}
|
|
local rps_flt = LED{parent=rps,label="PLC FAULT",colors=ind_red}
|
|
local rps_fail = LED{parent=rps,label="RCT FAULT",colors=ind_red}
|
|
rps.line_break()
|
|
local rps_dmg = LED{parent=rps,label="HI DAMAGE",colors=ind_red}
|
|
local rps_tmp = LED{parent=rps,label="HI TEMP",colors=ind_red}
|
|
rps.line_break()
|
|
local rps_nof = LED{parent=rps,label="LO FUEL",colors=ind_red}
|
|
local rps_wst = LED{parent=rps,label="HI WASTE",colors=ind_red}
|
|
rps.line_break()
|
|
local rps_ccl = LED{parent=rps,label="LO CCOOLANT",colors=ind_red}
|
|
local rps_hcl = LED{parent=rps,label="HI HCOOLANT",colors=ind_red}
|
|
|
|
rps_man.register(databus.ps, "rps_manual", rps_man.update)
|
|
rps_auto.register(databus.ps, "rps_automatic", rps_auto.update)
|
|
rps_tmo.register(databus.ps, "rps_timeout", rps_tmo.update)
|
|
rps_flt.register(databus.ps, "rps_fault", rps_flt.update)
|
|
rps_fail.register(databus.ps, "rps_sysfail", rps_fail.update)
|
|
rps_dmg.register(databus.ps, "rps_damage", rps_dmg.update)
|
|
rps_tmp.register(databus.ps, "rps_high_temp", rps_tmp.update)
|
|
rps_nof.register(databus.ps, "rps_no_fuel", rps_nof.update)
|
|
rps_wst.register(databus.ps, "rps_high_waste", rps_wst.update)
|
|
rps_ccl.register(databus.ps, "rps_low_ccool", rps_ccl.update)
|
|
rps_hcl.register(databus.ps, "rps_high_hcool", rps_hcl.update)
|
|
end
|
|
|
|
return init
|