cc-mek-scada/supervisor/session/rtu/boiler.lua
2022-05-11 13:02:21 -04:00

211 lines
7.0 KiB
Lua

local comms = require("scada-common.comms")
local log = require("scada-common.log")
local types = require("scada-common.types")
local util = require("scada-common.util")
local txnctrl = require("supervisor.session.rtu.txnctrl")
local boiler = {}
local PROTOCOLS = comms.PROTOCOLS
local MODBUS_FCODE = types.MODBUS_FCODE
local rtu_t = types.rtu_t
local TXN_TYPES = {
BUILD = 0,
STATE = 1,
TANKS = 2
}
local PERIODICS = {
BUILD = 1000,
STATE = 500,
TANKS = 1000
}
-- create a new boiler rtu session runner
---@param advert rtu_advertisement
---@param out_queue mqueue
boiler.new = function (advert, out_queue)
-- type check
if advert.type ~= rtu_t.boiler then
log.error("attempt to instantiate boiler RTU for non boiler type '" .. advert.type .. "'. this is a bug.")
return nil
end
local log_tag = "session.rtu.boiler(" .. advert.index .. "): "
local self = {
uid = advert.index,
reactor = advert.reactor,
out_q = out_queue,
transaction_controller = txnctrl.new(),
has_build = false,
periodics = {
next_build_req = 0,
next_state_req = 0,
next_tanks_req = 0,
},
---@class boiler_session_db
db = {
build = {
boil_cap = 0.0,
steam_cap = 0,
water_cap = 0,
hcoolant_cap = 0,
ccoolant_cap = 0,
superheaters = 0,
max_boil_rate = 0.0
},
state = {
temperature = 0.0,
boil_rate = 0.0
},
tanks = {
steam = 0,
steam_need = 0,
steam_fill = 0.0,
water = 0,
water_need = 0,
water_fill = 0.0,
hcool = 0,
hcool_need = 0,
hcool_fill = 0.0,
ccool = 0,
ccool_need = 0,
ccool_fill = 0.0
}
}
}
---@class rtu_session__boiler
local public = {}
-- PRIVATE FUNCTIONS --
-- query the build of the device
local _request_build = function ()
local m_pkt = comms.modbus_packet()
local txn_id = self.transaction_controller.create(TXN_TYPES.BUILD)
-- read input registers 1 through 7 (start = 1, count = 7)
m_pkt.make(txn_id, self.uid, MODBUS_FCODE.READ_INPUT_REGS, { 1, 7 })
self.out_q.push_packet(m_pkt)
end
-- query the state of the device
local _request_state = function ()
local m_pkt = comms.modbus_packet()
local txn_id = self.transaction_controller.create(TXN_TYPES.STATE)
-- read input registers 8 through 9 (start = 8, count = 2)
m_pkt.make(txn_id, self.uid, MODBUS_FCODE.READ_INPUT_REGS, { 8, 2 })
self.out_q.push_packet(m_pkt)
end
-- query the tanks of the device
local _request_tanks = function ()
local m_pkt = comms.modbus_packet()
local txn_id = self.transaction_controller.create(TXN_TYPES.TANKS)
-- read input registers 10 through 21 (start = 10, count = 12)
m_pkt.make(txn_id, self.uid, MODBUS_FCODE.READ_INPUT_REGS, { 10, 12 })
self.out_q.push_packet(m_pkt)
end
-- PUBLIC FUNCTIONS --
-- handle a packet
---@param m_pkt modbus_frame
public.handle_packet = function (m_pkt)
local success = false
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
if m_pkt.unit_id == self.uid then
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
if txn_type == TXN_TYPES.BUILD then
-- build response
if m_pkt.length == 7 then
self.db.build.boil_cap = m_pkt.data[1]
self.db.build.steam_cap = m_pkt.data[2]
self.db.build.water_cap = m_pkt.data[3]
self.db.build.hcoolant_cap = m_pkt.data[4]
self.db.build.ccoolant_cap = m_pkt.data[5]
self.db.build.superheaters = m_pkt.data[6]
self.db.build.max_boil_rate = m_pkt.data[7]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.build)")
end
elseif txn_type == TXN_TYPES.STATE then
-- state response
if m_pkt.length == 2 then
self.db.state.temperature = m_pkt.data[1]
self.db.state.boil_rate = m_pkt.data[2]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.state)")
end
elseif txn_type == TXN_TYPES.TANKS then
-- tanks response
if m_pkt.length == 12 then
self.db.tanks.steam = m_pkt.data[1]
self.db.tanks.steam_need = m_pkt.data[2]
self.db.tanks.steam_fill = m_pkt.data[3]
self.db.tanks.water = m_pkt.data[4]
self.db.tanks.water_need = m_pkt.data[5]
self.db.tanks.water_fill = m_pkt.data[6]
self.db.tanks.hcool = m_pkt.data[7]
self.db.tanks.hcool_need = m_pkt.data[8]
self.db.tanks.hcool_fill = m_pkt.data[9]
self.db.tanks.ccool = m_pkt.data[10]
self.db.tanks.ccool_need = m_pkt.data[11]
self.db.tanks.ccool_fill = m_pkt.data[12]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (boiler.tanks)")
end
elseif txn_type == nil then
log.error(log_tag .. "unknown transaction reply")
else
log.error(log_tag .. "unknown transaction type " .. txn_type)
end
else
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
end
else
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
end
return success
end
public.get_uid = function () return self.uid end
public.get_reactor = function () return self.reactor end
public.get_db = function () return self.db end
-- update this runner
---@param time_now integer milliseconds
public.update = function (time_now)
if not self.has_build and self.next_build_req <= time_now then
_request_build()
self.next_build_req = time_now + PERIODICS.BUILD
end
if self.next_state_req <= time_now then
_request_state()
self.next_state_req = time_now + PERIODICS.STATE
end
if self.next_tanks_req <= time_now then
_request_tanks()
self.next_tanks_req = time_now + PERIODICS.TANKS
end
end
return public
end
return boiler