cc-mek-scada/supervisor/supervisor.lua
2024-03-24 12:56:51 -04:00

475 lines
23 KiB
Lua

local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local themes = require("graphics.themes")
local svsessions = require("supervisor.session.svsessions")
local supervisor = {}
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local MGMT_TYPE = comms.MGMT_TYPE
---@type svr_config
local config = {}
supervisor.config = config
-- load the supervisor configuration
function supervisor.load_config()
if not settings.load("/supervisor.settings") then return false end
config.UnitCount = settings.get("UnitCount")
config.CoolingConfig = settings.get("CoolingConfig")
config.FacilityTankMode = settings.get("FacilityTankMode")
config.FacilityTankDefs = settings.get("FacilityTankDefs")
config.SVR_Channel = settings.get("SVR_Channel")
config.PLC_Channel = settings.get("PLC_Channel")
config.RTU_Channel = settings.get("RTU_Channel")
config.CRD_Channel = settings.get("CRD_Channel")
config.PKT_Channel = settings.get("PKT_Channel")
config.PLC_Timeout = settings.get("PLC_Timeout")
config.RTU_Timeout = settings.get("RTU_Timeout")
config.CRD_Timeout = settings.get("CRD_Timeout")
config.PKT_Timeout = settings.get("PKT_Timeout")
config.TrustedRange = settings.get("TrustedRange")
config.AuthKey = settings.get("AuthKey")
config.LogMode = settings.get("LogMode")
config.LogPath = settings.get("LogPath")
config.LogDebug = settings.get("LogDebug")
config.FrontPanelTheme = settings.get("FrontPanelTheme")
config.ColorMode = settings.get("ColorMode")
local cfv = util.new_validator()
cfv.assert_type_int(config.UnitCount)
cfv.assert_range(config.UnitCount, 1, 4)
cfv.assert_type_table(config.CoolingConfig)
cfv.assert_type_table(config.FacilityTankDefs)
cfv.assert_type_int(config.FacilityTankMode)
cfv.assert_range(config.FacilityTankMode, 0, 8)
cfv.assert_channel(config.SVR_Channel)
cfv.assert_channel(config.PLC_Channel)
cfv.assert_channel(config.RTU_Channel)
cfv.assert_channel(config.CRD_Channel)
cfv.assert_channel(config.PKT_Channel)
cfv.assert_type_num(config.PLC_Timeout)
cfv.assert_min(config.PLC_Timeout, 2)
cfv.assert_type_num(config.RTU_Timeout)
cfv.assert_min(config.RTU_Timeout, 2)
cfv.assert_type_num(config.CRD_Timeout)
cfv.assert_min(config.CRD_Timeout, 2)
cfv.assert_type_num(config.PKT_Timeout)
cfv.assert_min(config.PKT_Timeout, 2)
cfv.assert_type_num(config.TrustedRange)
cfv.assert_min(config.TrustedRange, 0)
if type(config.AuthKey) == "string" then
local len = string.len(config.AuthKey)
cfv.assert_eq(len == 0 or len >= 8, true)
end
cfv.assert_type_int(config.LogMode)
cfv.assert_range(config.LogMode, 0, 1)
cfv.assert_type_str(config.LogPath)
cfv.assert_type_bool(config.LogDebug)
cfv.assert_type_int(config.FrontPanelTheme)
cfv.assert_range(config.FrontPanelTheme, 1, 2)
cfv.assert_type_int(config.ColorMode)
cfv.assert_range(config.ColorMode, 1, themes.COLOR_MODE.NUM_MODES)
return cfv.valid()
end
-- supervisory controller communications
---@nodiscard
---@param _version string supervisor version
---@param nic nic network interface device
---@param fp_ok boolean if the front panel UI is running
---@diagnostic disable-next-line: unused-local
function supervisor.comms(_version, nic, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
---@class sv_cooling_conf
local cooling_conf = { r_cool = config.CoolingConfig, fac_tank_mode = config.FacilityTankMode, fac_tank_defs = config.FacilityTankDefs }
local self = {
last_est_acks = {}
}
comms.set_trusted_range(config.TrustedRange)
-- PRIVATE FUNCTIONS --
-- configure modem channels
nic.closeAll()
nic.open(config.SVR_Channel)
-- pass modem, status, and config data to svsessions
svsessions.init(nic, fp_ok, config, cooling_conf)
-- send an establish request response
---@param packet scada_packet
---@param ack ESTABLISH_ACK
---@param data? any optional data
local function _send_establish(packet, ack, data)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(MGMT_TYPE.ESTABLISH, { ack, data })
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
nic.transmit(packet.remote_channel(), config.SVR_Channel, s_pkt)
self.last_est_acks[packet.src_addr()] = ack
end
-- PUBLIC FUNCTIONS --
---@class superv_comms
local public = {}
-- parse a packet
---@nodiscard
---@param side string
---@param sender integer
---@param reply_to integer
---@param message any
---@param distance integer
---@return modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil packet
function public.parse_packet(side, sender, reply_to, message, distance)
local s_pkt = nic.receive(side, sender, reply_to, message, distance)
local pkt = nil
if s_pkt then
-- get as MODBUS TCP packet
if s_pkt.protocol() == PROTOCOL.MODBUS_TCP then
local m_pkt = comms.modbus_packet()
if m_pkt.decode(s_pkt) then
pkt = m_pkt.get()
end
-- get as RPLC packet
elseif s_pkt.protocol() == PROTOCOL.RPLC then
local rplc_pkt = comms.rplc_packet()
if rplc_pkt.decode(s_pkt) then
pkt = rplc_pkt.get()
end
-- get as SCADA management packet
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
end
-- get as coordinator packet
elseif s_pkt.protocol() == PROTOCOL.SCADA_CRDN then
local crdn_pkt = comms.crdn_packet()
if crdn_pkt.decode(s_pkt) then
pkt = crdn_pkt.get()
end
else
log.debug("attempted parse of illegal packet type " .. s_pkt.protocol(), true)
end
end
return pkt
end
-- handle a packet
---@param packet modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil
function public.handle_packet(packet)
if packet ~= nil then
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
local src_addr = packet.scada_frame.src_addr()
local protocol = packet.scada_frame.protocol()
if l_chan ~= config.SVR_Channel then
log.debug("received packet on unconfigured channel " .. l_chan, true)
elseif r_chan == config.PLC_Channel then
-- look for an associated session
local session = svsessions.find_plc_session(src_addr)
if protocol == PROTOCOL.RPLC then
---@cast packet rplc_frame
-- reactor PLC packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug("discarding RPLC packet without a known session")
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping PLC establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.PLC then
-- PLC linking request
if packet.length == 4 and type(packet.data[4]) == "number" then
local reactor_id = packet.data[4]
local plc_id = svsessions.establish_plc_session(src_addr, reactor_id, firmware_v)
if plc_id == false then
-- reactor already has a PLC assigned
if last_ack ~= ESTABLISH_ACK.COLLISION then
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
else
-- got an ID; assigned to a reactor successfully
println(util.c("PLC (", firmware_v, ") [@", src_addr, "] \xbb reactor ", reactor_id, " connected"))
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
end
else
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("invalid establish packet (on PLC channel)")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding PLC SCADA_MGMT packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
end
elseif r_chan == config.RTU_Channel then
-- look for an associated session
local session = svsessions.find_rtu_session(src_addr)
if protocol == PROTOCOL.MODBUS_TCP then
---@cast packet modbus_frame
-- MODBUS response
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug("discarding MODBUS_TCP packet without a known session")
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping RTU establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.RTU then
if packet.length == 4 then
-- this is an RTU advertisement for a new session
local rtu_advert = packet.data[4]
local s_id = svsessions.establish_rtu_session(src_addr, rtu_advert, firmware_v)
println(util.c("RTU (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
else
log.debug("RTU_ESTABLISH: packet length mismatch")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on RTU channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("invalid establish packet (on RTU channel)")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding RTU SCADA_MGMT packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
end
elseif r_chan == config.CRD_Channel then
-- look for an associated session
local session = svsessions.find_crd_session(src_addr)
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping coordinator establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.CRD then
-- this is an attempt to establish a new coordinator session
local s_id = svsessions.establish_crd_session(src_addr, firmware_v)
if s_id ~= false then
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
else
if last_ack ~= ESTABLISH_ACK.COLLISION then
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
end
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on coordinator channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("CRD_ESTABLISH: establish packet length mismatch")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding coordinator SCADA_MGMT packet without a known session from computer ", src_addr))
end
elseif protocol == PROTOCOL.SCADA_CRDN then
---@cast packet crdn_frame
-- coordinator packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding coordinator SCADA_CRDN packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
end
elseif r_chan == config.PKT_Channel then
-- look for an associated session
local session = svsessions.find_pdg_session(src_addr)
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping PDG establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.PKT then
-- this is an attempt to establish a new pocket diagnostic session
local s_id = svsessions.establish_pdg_session(src_addr, firmware_v)
println(util.c("PKT (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("PDG_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on pocket channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("PDG_ESTABLISH: establish packet length mismatch")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding pocket SCADA_MGMT packet without a known session from computer ", src_addr))
end
elseif protocol == PROTOCOL.SCADA_CRDN then
---@cast packet crdn_frame
-- coordinator packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding pocket SCADA_CRDN packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on pocket channel"))
end
else
log.debug("received packet for unknown channel " .. r_chan, true)
end
end
end
return public
end
return supervisor