cc-mek-scada/supervisor/supervisor.lua
2022-08-28 12:12:30 -04:00

304 lines
12 KiB
Lua

local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local svsessions = require("supervisor.session.svsessions")
local supervisor = {}
local PROTOCOLS = comms.PROTOCOLS
local RPLC_TYPES = comms.RPLC_TYPES
local RPLC_LINKING = comms.RPLC_LINKING
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local SCADA_CRDN_TYPES = comms.SCADA_CRDN_TYPES
local SESSION_TYPE = svsessions.SESSION_TYPE
local print = util.print
local println = util.println
local print_ts = util.print_ts
local println_ts = util.println_ts
-- supervisory controller communications
---@param version string
---@param num_reactors integer
---@param cooling_conf table
---@param modem table
---@param dev_listen integer
---@param coord_listen integer
function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen, coord_listen)
local self = {
version = version,
num_reactors = num_reactors,
modem = modem,
dev_listen = dev_listen,
coord_listen = coord_listen,
reactor_struct_cache = nil
}
---@class superv_comms
local public = {}
-- PRIVATE FUNCTIONS --
-- open all channels
local function _open_channels()
if not self.modem.isOpen(self.dev_listen) then
self.modem.open(self.dev_listen)
end
if not self.modem.isOpen(self.coord_listen) then
self.modem.open(self.coord_listen)
end
end
-- open at construct time
_open_channels()
-- link modem to svsessions
svsessions.init(self.modem, num_reactors, cooling_conf)
-- send PLC link request response
---@param dest integer
---@param msg table
local function _send_plc_linking(seq_id, dest, msg)
local s_pkt = comms.scada_packet()
local r_pkt = comms.rplc_packet()
r_pkt.make(0, RPLC_TYPES.LINK_REQ, msg)
s_pkt.make(seq_id, PROTOCOLS.RPLC, r_pkt.raw_sendable())
self.modem.transmit(dest, self.dev_listen, s_pkt.raw_sendable())
end
-- send RTU advertisement response
---@param seq_id integer
---@param dest integer
local function _send_remote_linked(seq_id, dest)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(SCADA_MGMT_TYPES.REMOTE_LINKED, {})
s_pkt.make(seq_id, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
self.modem.transmit(dest, self.dev_listen, s_pkt.raw_sendable())
end
-- send coordinator connection establish response
---@param seq_id integer
---@param dest integer
local function _send_crdn_establish(seq_id, dest)
local s_pkt = comms.scada_packet()
local c_pkt = comms.crdn_packet()
local config = { self.num_reactors }
for i = 1, #cooling_conf do
table.insert(config, cooling_conf[i].BOILERS)
table.insert(config, cooling_conf[i].TURBINES)
end
c_pkt.make(SCADA_CRDN_TYPES.ESTABLISH, config)
s_pkt.make(seq_id, PROTOCOLS.SCADA_CRDN, c_pkt.raw_sendable())
self.modem.transmit(dest, self.coord_listen, s_pkt.raw_sendable())
end
-- PUBLIC FUNCTIONS --
-- reconnect a newly connected modem
---@param modem table
---@diagnostic disable-next-line: redefined-local
function public.reconnect_modem(modem)
self.modem = modem
svsessions.relink_modem(self.modem)
_open_channels()
end
-- parse a packet
---@param side string
---@param sender integer
---@param reply_to integer
---@param message any
---@param distance integer
---@return modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil packet
function public.parse_packet(side, sender, reply_to, message, distance)
local pkt = nil
local s_pkt = comms.scada_packet()
-- parse packet as generic SCADA packet
s_pkt.receive(side, sender, reply_to, message, distance)
if s_pkt.is_valid() then
-- get as MODBUS TCP packet
if s_pkt.protocol() == PROTOCOLS.MODBUS_TCP then
local m_pkt = comms.modbus_packet()
if m_pkt.decode(s_pkt) then
pkt = m_pkt.get()
end
-- get as RPLC packet
elseif s_pkt.protocol() == PROTOCOLS.RPLC then
local rplc_pkt = comms.rplc_packet()
if rplc_pkt.decode(s_pkt) then
pkt = rplc_pkt.get()
end
-- get as SCADA management packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
end
-- get as coordinator packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_CRDN then
local crdn_pkt = comms.crdn_packet()
if crdn_pkt.decode(s_pkt) then
pkt = crdn_pkt.get()
end
else
log.debug("attempted parse of illegal packet type " .. s_pkt.protocol(), true)
end
end
return pkt
end
-- handle a packet
---@param packet modbus_frame|rplc_frame|mgmt_frame|crdn_frame
function public.handle_packet(packet)
if packet ~= nil then
local l_port = packet.scada_frame.local_port()
local r_port = packet.scada_frame.remote_port()
local protocol = packet.scada_frame.protocol()
-- device (RTU/PLC) listening channel
if l_port == self.dev_listen then
if protocol == PROTOCOLS.MODBUS_TCP then
-- look for an associated session
local session = svsessions.find_rtu_session(r_port)
-- MODBUS response
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug("discarding MODBUS_TCP packet without a known session")
end
elseif protocol == PROTOCOLS.RPLC then
-- look for an associated session
local session = svsessions.find_plc_session(r_port)
-- reactor PLC packet
if session ~= nil then
if packet.type == RPLC_TYPES.LINK_REQ then
-- new device on this port? that's a collision
log.debug("PLC_LNK: request from existing connection received on " .. r_port .. ", responding with collision")
_send_plc_linking(packet.scada_frame.seq_num() + 1, r_port, { RPLC_LINKING.COLLISION })
else
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
end
else
local next_seq_id = packet.scada_frame.seq_num() + 1
-- unknown session, is this a linking request?
if packet.type == RPLC_TYPES.LINK_REQ then
if packet.length == 2 then
-- this is a linking request
local plc_id = svsessions.establish_plc_session(l_port, r_port, packet.data[1], packet.data[2])
if plc_id == false then
-- reactor already has a PLC assigned
log.debug(util.c("PLC_LNK: assignment collision with reactor ", packet.data[1]))
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.COLLISION })
else
-- got an ID; assigned to a reactor successfully
println(util.c("connected to reactor ", packet.data[1], " PLC (", packet.data[2], ") [:", r_port, "]"))
log.debug("PLC_LNK: allowed for device at " .. r_port)
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.ALLOW })
end
else
log.debug("PLC_LNK: new linking packet length mismatch")
end
else
-- force a re-link
log.debug("PLC_LNK: no session but not a link, force relink")
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.DENY })
end
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
-- look for an associated session
local session = svsessions.find_device_session(r_port)
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPES.RTU_ADVERT then
if packet.length >= 1 then
-- this is an RTU advertisement for a new session
println(util.c("connected to RTU (", packet.data[1], ") [:", r_port, "]"))
svsessions.establish_rtu_session(l_port, r_port, packet.data)
log.debug("RTU_ADVERT: linked " .. r_port)
_send_remote_linked(packet.scada_frame.seq_num() + 1, r_port)
else
log.debug("RTU_ADVERT: advertisement packet empty")
end
else
-- any other packet should be session related, discard it
log.debug(util.c(r_port, "->", l_port, ": discarding SCADA_MGMT packet without a known session"))
end
else
log.debug("illegal packet type " .. protocol .. " on device listening channel")
end
-- coordinator listening channel
elseif l_port == self.coord_listen then
-- look for an associated session
local session = svsessions.find_coord_session(r_port)
if protocol == PROTOCOLS.SCADA_MGMT then
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug(util.c(r_port, "->", l_port, ": discarding SCADA_MGMT packet without a known session"))
end
elseif protocol == PROTOCOLS.SCADA_CRDN then
-- coordinator packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_CRDN_TYPES.ESTABLISH then
if packet.length == 1 then
-- this is an attempt to establish a new session
println(util.c("connected to coordinator [:", r_port, "]"))
svsessions.establish_coord_session(l_port, r_port, packet.data[1])
log.debug("CRDN_ESTABLISH: connected to " .. r_port)
_send_crdn_establish(packet.scada_frame.seq_num() + 1, r_port)
else
log.debug("CRDN_ESTABLISH: establish packet length mismatch")
end
else
-- any other packet should be session related, discard it
log.debug(util.c(r_port, "->", l_port, ": discarding SCADA_CRDN packet without a known session"))
end
else
log.debug("illegal packet type " .. protocol .. " on coordinator listening channel")
end
else
log.warning("received packet on unused channel " .. l_port)
end
end
end
return public
end