cc-mek-scada/reactor-plc/panel/front_panel.lua

191 lines
8.1 KiB
Lua

--
-- Reactor PLC Front Panel GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("reactor-plc.databus")
local plc = require("reactor-plc.plc")
local style = require("reactor-plc.panel.style")
local core = require("graphics.core")
local flasher = require("graphics.flasher")
local Div = require("graphics.elements.div")
local Rectangle = require("graphics.elements.rectangle")
local TextBox = require("graphics.elements.textbox")
local PushButton = require("graphics.elements.controls.push_button")
local LED = require("graphics.elements.indicators.led")
local LEDPair = require("graphics.elements.indicators.ledpair")
local RGBLED = require("graphics.elements.indicators.ledrgb")
local LINK_STATE = types.PANEL_LINK_STATE
local ALIGN = core.ALIGN
local cpair = core.cpair
local border = core.border
local ind_grn = style.ind_grn
local ind_red = style.ind_red
-- create new front panel view
---@param panel graphics_element main displaybox
local function init(panel)
local s_hi_box = style.theme.highlight_box
local disabled_fg = style.fp.disabled_fg
local header = TextBox{parent=panel,y=1,text="FISSION REACTOR PLC - UNIT ?",alignment=ALIGN.CENTER,fg_bg=style.theme.header}
header.register(databus.ps, "unit_id", function (id) header.set_value(util.c("FISSION REACTOR PLC - UNIT ", id)) end)
--
-- system indicators
--
local system = Div{parent=panel,width=14,height=18,x=2,y=3}
local init_ok = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=ind_grn}
system.line_break()
init_ok.register(databus.ps, "init_ok", init_ok.update)
heartbeat.register(databus.ps, "heartbeat", heartbeat.update)
local reactor = LEDPair{parent=system,label="REACTOR",off=colors.red,c1=colors.yellow,c2=colors.green}
local modem = LED{parent=system,label="MODEM",colors=ind_grn}
if not style.colorblind then
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,style.ind_bkg}}
network.update(types.PANEL_LINK_STATE.DISCONNECTED)
network.register(databus.ps, "link_state", network.update)
else
local nt_lnk = LEDPair{parent=system,label="NT LINKED",off=style.ind_bkg,c1=colors.red,c2=colors.green}
local nt_ver = LEDPair{parent=system,label="NT VERSION",off=style.ind_bkg,c1=colors.red,c2=colors.green}
local nt_col = LED{parent=system,label="NT COLLISION",colors=ind_red}
nt_lnk.register(databus.ps, "link_state", function (state)
local value = 2
if state == LINK_STATE.DISCONNECTED then
value = 1
elseif state == LINK_STATE.LINKED then
value = 3
end
nt_lnk.update(value)
end)
nt_ver.register(databus.ps, "link_state", function (state)
local value = 3
if state == LINK_STATE.BAD_VERSION then
value = 2
elseif state == LINK_STATE.DISCONNECTED then
value = 1
end
nt_ver.update(value)
end)
nt_col.register(databus.ps, "link_state", function (state) nt_col.update(state == LINK_STATE.COLLISION) end)
end
system.line_break()
reactor.register(databus.ps, "reactor_dev_state", reactor.update)
modem.register(databus.ps, "has_modem", modem.update)
local rt_main = LED{parent=system,label="RT MAIN",colors=ind_grn}
local rt_rps = LED{parent=system,label="RT RPS",colors=ind_grn}
local rt_cmtx = LED{parent=system,label="RT COMMS TX",colors=ind_grn}
local rt_cmrx = LED{parent=system,label="RT COMMS RX",colors=ind_grn}
local rt_sctl = LED{parent=system,label="RT SPCTL",colors=ind_grn}
system.line_break()
rt_main.register(databus.ps, "routine__main", rt_main.update)
rt_rps.register(databus.ps, "routine__rps", rt_rps.update)
rt_cmtx.register(databus.ps, "routine__comms_tx", rt_cmtx.update)
rt_cmrx.register(databus.ps, "routine__comms_rx", rt_cmrx.update)
rt_sctl.register(databus.ps, "routine__spctl", rt_sctl.update)
---@diagnostic disable-next-line: undefined-field
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=5,width=6,text=comp_id,fg_bg=disabled_fg}
--
-- status & controls
--
local status = Div{parent=panel,width=19,height=18,x=17,y=3}
local active = LED{parent=status,x=2,width=12,label="RCT ACTIVE",colors=ind_grn}
-- only show emergency coolant LED if emergency coolant is configured for this device
if plc.config.EmerCoolEnable then
local emer_cool = LED{parent=status,x=2,width=14,label="EMER COOLANT",colors=cpair(colors.yellow,colors.yellow_off)}
emer_cool.register(databus.ps, "emer_cool", emer_cool.update)
end
local status_trip_rct = Rectangle{parent=status,width=20,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
local status_trip = Div{parent=status_trip_rct,width=18,height=1,fg_bg=s_hi_box}
local scram = LED{parent=status_trip,width=10,label="RPS TRIP",colors=ind_red,flash=true,period=flasher.PERIOD.BLINK_250_MS}
local controls_rct = Rectangle{parent=status,width=17,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
local controls = Div{parent=controls_rct,width=15,height=1,fg_bg=s_hi_box}
PushButton{parent=controls,x=1,y=1,min_width=7,text="SCRAM",callback=databus.rps_scram,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.black,colors.red_off)}
PushButton{parent=controls,x=9,y=1,min_width=7,text="RESET",callback=databus.rps_reset,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.black,colors.yellow_off)}
active.register(databus.ps, "reactor_active", active.update)
scram.register(databus.ps, "rps_scram", scram.update)
--
-- about footer
--
local about = Div{parent=panel,width=15,height=3,x=1,y=18,fg_bg=disabled_fg}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00",alignment=ALIGN.LEFT}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00",alignment=ALIGN.LEFT}
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
--
-- rps list
--
local rps = Rectangle{parent=panel,width=16,height=16,x=36,y=3,border=border(1,s_hi_box.bkg),thin=true,fg_bg=s_hi_box}
local rps_man = LED{parent=rps,label="MANUAL",colors=ind_red}
local rps_auto = LED{parent=rps,label="AUTOMATIC",colors=ind_red}
local rps_tmo = LED{parent=rps,label="TIMEOUT",colors=ind_red}
local rps_flt = LED{parent=rps,label="PLC FAULT",colors=ind_red}
local rps_fail = LED{parent=rps,label="RCT FAULT",colors=ind_red}
rps.line_break()
local rps_dmg = LED{parent=rps,label="HI DAMAGE",colors=ind_red}
local rps_tmp = LED{parent=rps,label="HI TEMP",colors=ind_red}
rps.line_break()
local rps_nof = LED{parent=rps,label="LO FUEL",colors=ind_red}
local rps_wst = LED{parent=rps,label="HI WASTE",colors=ind_red}
rps.line_break()
local rps_ccl = LED{parent=rps,label="LO CCOOLANT",colors=ind_red}
local rps_hcl = LED{parent=rps,label="HI HCOOLANT",colors=ind_red}
rps_man.register(databus.ps, "rps_manual", rps_man.update)
rps_auto.register(databus.ps, "rps_automatic", rps_auto.update)
rps_tmo.register(databus.ps, "rps_timeout", rps_tmo.update)
rps_flt.register(databus.ps, "rps_fault", rps_flt.update)
rps_fail.register(databus.ps, "rps_sysfail", rps_fail.update)
rps_dmg.register(databus.ps, "rps_damage", rps_dmg.update)
rps_tmp.register(databus.ps, "rps_high_temp", rps_tmp.update)
rps_nof.register(databus.ps, "rps_no_fuel", rps_nof.update)
rps_wst.register(databus.ps, "rps_high_waste", rps_wst.update)
rps_ccl.register(databus.ps, "rps_low_ccool", rps_ccl.update)
rps_hcl.register(databus.ps, "rps_high_hcool", rps_hcl.update)
end
return init