Merge pull request #105 from wtadler/develop
Edit README notes on baud rate and external temperature sensor
This commit is contained in:
commit
38d089fce3
27
README.md
27
README.md
@ -365,7 +365,9 @@ climate:
|
|||||||
`UART0`, `UART1`, and `UART2` are all valid choices. Default: `UART0`
|
`UART0`, `UART1`, and `UART2` are all valid choices. Default: `UART0`
|
||||||
* `baud_rate` (_Optional_): Serial BAUD rate used to communicate with the
|
* `baud_rate` (_Optional_): Serial BAUD rate used to communicate with the
|
||||||
HeatPump. Most systems use the default value of `4800` baud, but some use
|
HeatPump. Most systems use the default value of `4800` baud, but some use
|
||||||
`2400` or `9600`. Some ESP32 boards will require the baud_rate setting if
|
`2400` or `9600`. Check [here](https://github.com/SwiCago/HeatPump/issues/13)
|
||||||
|
to find discussion of whether your particular model requires a non-default baud rate.
|
||||||
|
Some ESP32 boards will require the baud_rate setting if
|
||||||
hardware_uart is specified. Default: `4800`.
|
hardware_uart is specified. Default: `4800`.
|
||||||
* `rx_pin` (_Optional_): pin number to use as RX for the specified hardware
|
* `rx_pin` (_Optional_): pin number to use as RX for the specified hardware
|
||||||
UART (ESP32 only - ESP8266 hardware UART's pins aren't configurable).
|
UART (ESP32 only - ESP8266 hardware UART's pins aren't configurable).
|
||||||
@ -409,9 +411,11 @@ climate:
|
|||||||
|
|
||||||
It is possible to use an external temperature sensor to tell the heat pump what
|
It is possible to use an external temperature sensor to tell the heat pump what
|
||||||
the room temperature is, rather than relying on its internal temperature
|
the room temperature is, rather than relying on its internal temperature
|
||||||
sensor. You can do this by calling `set_remote_temperature(float temp)` on the
|
sensor. This is helpful if you want to make sure that a particular room, or part
|
||||||
`mitsubishi_heatpump` object in a lambda. Note that you can call
|
of the room, reaches the desired temperature—rather than just the area near the
|
||||||
`set_remote_temperature(0)` to switch back to the internal temperature sensor.
|
heat pump or the thermostat. You can do this by calling `set_remote_temperature(float temp)`
|
||||||
|
on the `mitsubishi_heatpump` object in a lambda. (If needed, you can call
|
||||||
|
`set_remote_temperature(0)` to switch back to the internal temperature sensor.)
|
||||||
|
|
||||||
There are several ways you could make use of this functionality. One is to use
|
There are several ways you could make use of this functionality. One is to use
|
||||||
a sensor automation:
|
a sensor automation:
|
||||||
@ -423,7 +427,7 @@ climate:
|
|||||||
id: hp
|
id: hp
|
||||||
|
|
||||||
sensor:
|
sensor:
|
||||||
# You could use a Bluetooth temperature sensor
|
# You could use a Bluetooth temperature sensor as the source...
|
||||||
- platform: atc_mithermometer
|
- platform: atc_mithermometer
|
||||||
mac_address: "XX:XX:XX:XX:XX:XX"
|
mac_address: "XX:XX:XX:XX:XX:XX"
|
||||||
temperature:
|
temperature:
|
||||||
@ -432,7 +436,7 @@ sensor:
|
|||||||
then:
|
then:
|
||||||
- lambda: 'id(hp).set_remote_temperature(x);'
|
- lambda: 'id(hp).set_remote_temperature(x);'
|
||||||
|
|
||||||
# Or you could use a HomeAssistant sensor
|
# ...or you could use a Home Assistant sensor as the source
|
||||||
- platform: homeassistant
|
- platform: homeassistant
|
||||||
name: "Temperature Sensor From Home Assistant"
|
name: "Temperature Sensor From Home Assistant"
|
||||||
entity_id: sensor.temperature_sensor
|
entity_id: sensor.temperature_sensor
|
||||||
@ -440,10 +444,17 @@ sensor:
|
|||||||
then:
|
then:
|
||||||
- lambda: 'id(hp).set_remote_temperature(x);'
|
- lambda: 'id(hp).set_remote_temperature(x);'
|
||||||
```
|
```
|
||||||
|
One issue that you might have here is that, after some amount of time with no update from the
|
||||||
|
external temperature sensor, the heat pump will revert back to its internal temperature.
|
||||||
|
You can prevent this by [adding a `heartbeat` filter](https://github.com/geoffdavis/esphome-mitsubishiheatpump/issues/31#issuecomment-1207115352)
|
||||||
|
to the sensor, which will keep reminding the heat pump of the external sensor value.
|
||||||
|
|
||||||
Alternatively you could define a
|
Also, if your external sensor is in Fahrenheit, you will have to [convert the value to Celsius](https://github.com/geoffdavis/esphome-mitsubishiheatpump/issues/31#issuecomment-1207115352).
|
||||||
|
|
||||||
|
|
||||||
|
Alternatively, you could define a
|
||||||
[service](https://www.esphome.io/components/api.html#user-defined-services)
|
[service](https://www.esphome.io/components/api.html#user-defined-services)
|
||||||
that HomeAssistant can call:
|
that Home Assistant can call:
|
||||||
|
|
||||||
```yaml
|
```yaml
|
||||||
api:
|
api:
|
||||||
|
Loading…
Reference in New Issue