diff --git a/README.md b/README.md index ce3e8db..78a965c 100644 --- a/README.md +++ b/README.md @@ -337,9 +337,10 @@ climate: rx_pin: 9 tx_pin: 10 supports: - mode: [HEAT_COOL, COOL, HEAT, FAN_ONLY] - fan_mode: [AUTO, LOW, MEDIUM, HIGH] - swing_mode: [OFF, VERTICAL] + mode: ["HEAT_COOL", "COOL", "HEAT", "FAN_ONLY"] + fan_mode: ["AUTO", "LOW", "MEDIUM", "HIGH"] + swing_mode: ["OFF", "VERTICAL"] + visual: min_temperature: 16 max_temperature: 31 @@ -361,14 +362,13 @@ climate: * *update\_interval* (_Optional_, range: 0ms to 9000ms): How often this component polls the heatpump hardware, in milliseconds. Maximum usable value is 9 seconds due to underlying issues with the HeatPump library. Default: 500ms -* *supports* (_Optional_): Supported features for the device. ** *mode* - (_Optional_, list): Supported climate modes for the HeatPump. Default: - `['HEAT_COOL', 'COOL', 'HEAT', 'DRY', 'FAN_ONLY']` - ** *fan_mode* (_Optional_, list): - Supported fan speeds for the HeatPump. Default: `['AUTO', 'DIFFUSE', 'LOW', - 'MEDIUM', 'MIDDLE', 'HIGH']` ** *swing_mode* (_Optional_, list): Supported - fan swing modes. Most Mitsubishi units only support the default. Default: - `['OFF', 'VERTICAL']` +* *supports* (_Optional_): Supported features for the device. + * *mode* (_Optional_, list): Supported climate modes for the HeatPump. Default: + `['HEAT_COOL', 'COOL', 'HEAT', 'DRY', 'FAN_ONLY']` + * *fan_mode* (_Optional_, list): Supported fan speeds for the HeatPump. + Default: `['AUTO', 'DIFFUSE', 'LOW', 'MEDIUM', 'MIDDLE', 'HIGH']` + * *swing_mode* (_Optional_, list): Supported fan swing modes. Most Mitsubishi + units only support the default. Default: `['OFF', 'VERTICAL']` ## Other configuration