Added clarification for hardware_serial & baud_rate setting
Per #72 , added clarifications that setting baud_rate may be required on some ESP32 boards (mine is Huzzah32 Feather) or else you will go into boot loop. Also, added detail to baud_rate setting that some heat pumps require 2400. Mine is MSZ-GL18NA, which only worked with 2400 (not 4800 or 9600). Note, the default swicago library will first try 2400, and then try 9600, if no explicit rate is provided.
This commit is contained in:
parent
980271337a
commit
10949d3067
11
README.md
11
README.md
@ -107,6 +107,7 @@ climate:
|
||||
|
||||
# Optional
|
||||
hardware_uart: UART0
|
||||
baud_rate: 4800
|
||||
|
||||
# Optional
|
||||
update_interval: 500ms
|
||||
@ -121,7 +122,8 @@ logger:
|
||||
```
|
||||
|
||||
On ESP32 you can change `hardware_uart` to `UART1` or `UART2` and keep logging
|
||||
enabled on the main serial port.
|
||||
enabled on the main serial port. This may require specifying baud_rate on some
|
||||
ESP32 boards.
|
||||
|
||||
*Note:* this component DOES NOT use the ESPHome `uart` component, as it
|
||||
requires direct access to a hardware UART via the Arduino `HardwareSerial`
|
||||
@ -223,8 +225,10 @@ climate:
|
||||
|
||||
# ESP32 only - change UART0 to UART1 or UART2 and remove the
|
||||
# logging:baud_rate above to allow the built-in UART0 to function for
|
||||
# logging.
|
||||
# logging.
|
||||
# Some ESP32 boards will require the baud_rate setting if hardware_uart is specified.
|
||||
hardware_uart: UART0
|
||||
baud_rate: 4800
|
||||
```
|
||||
|
||||
# Advanced configuration
|
||||
@ -256,7 +260,8 @@ climate:
|
||||
`UART0`, `UART1`, and `UART2` are all valid choices. Default: `UART0`
|
||||
* *baud\_rate* (_Optional_): Serial BAUD rate used to communicate with the
|
||||
HeatPump. Most systems use the default value of `4800` baud, but some use
|
||||
`9600`. Default: `4800`
|
||||
`2400` or `9600`. Some ESP32 boards will require the baud_rate setting if
|
||||
hardware_uart is specified. Default: `4800`.
|
||||
* *update\_interval* (_Optional_, range: 0ms to 9000ms): How often this
|
||||
component polls the heatpump hardware, in milliseconds. Maximum usable value
|
||||
is 9 seconds due to underlying issues with the HeatPump library. Default: 500ms
|
||||
|