Flow test note

#261
This commit is contained in:
lawgicau
2021-07-13 19:59:28 +10:00
parent af041ab661
commit 41d851ef8f

View File

@ -509,7 +509,7 @@
</div>
<p>Now slice and print!</p>
<h2>Interpreting Results:</h2>
<p>Use digital/vernier callipers to measure the outer wall thickness of the hollow cube. Take measurements in multiple places/sides and average them.</p>
<p>Use digital/vernier callipers to measure the outer wall thickness of the hollow cube. Take measurements in multiple places/sides and average them. You may wish to cut/tear off the lower and upper layers of the cube. This is to remove portions with elephant's foot and/or other abnormalities.</p>
<a href="#" data-featherlight="img/measurecube.jpg"><img class="thumb" src="img/measurecube.jpg" /></a>
<p>If your measurement is <i>significantly</i> off, the following calculator can then be used to calculate the new flow rate:</p>
<table>