1. Overview

1.1 AtragMx from Horus Vision

Horus ATragMX software considers atmospheric conditions, gun data, ammunition, range, speed and muzzle velocity to calculate precise aiming solutions with "come-up" results and even accounts for Coriolis and spin drift effects. ATragMX, loaded on a handheld computer made by TDS Recon, is easy to use and lightning-fast. The Recon meets the rigorous MIL-STD-810F military standard for drops, vibration, humidity, altitude and extreme temperatures.

2. Requirement

3. Usage

3.1 Opening the AtragMx

3.1.1 Interaction Menu

  • Open the self interaction menu Ctrl + ⊞ Win
  • Select Equipment
  • Select Open AtragMx

3.1.2 Custom key

  • OPTIONS / CONTROLS / CONFIGURE ADDONS / ACE3 Equipment

3.1.3 Inventory

Inventory

3.2 Example with M14 and default 7.62mm 20Rnd Mag

Start of the mission:

  • Open the Range Card and check the cartridge, the zeroed distance, the rifle twist, the muzzle velocity at 15°C and the bore height. RangeCard

  • Open the AtragMx and the Atmsphr column, select Default and Done. [Manual]

  • Open Gun the 7.62x51mm M80 in the GunList. [Manual]

  • Select E (English unit) at the top right. [Manual]

  • Open the Gun column, check and update the Bore, the Rifle Twist and Done.

  • Select M (Metric unit) at the top right.

  • Open the Gun column, check and update the Muzzle Velocity, the Zero Range and Done.

  • The Muzzle Velocity Table will be automatically updated. [Manual]

  • (Must be edited manually for specific cartridges according with the range card)

  • Optionally, Save Gun and Done in the GunList.

In position:

  • Update the Atmsphr column with the Kestrel 4500 and Done.
  • Check the new Muzzle Velocity in the Gun column.
  • Update the Target column (the wind arrow will also help). [1] [2] [3] [4]
  • Apply the vertical and horizontal elevations on the scope.
  • Control the breath and press.

3.3 Example with Truing tool

Start of the mission:

  • Select Drag Coef Table in the Options menu.
  • Add the ZR and the C1 (Gun column) in the table and Done.

In position:

  • Open the Truing Drop in the Options menu. [Manual]
  • Add the actual Target Range in the SUPER column and Calc.
  • Add the same Target Range in the SUB column and Calc.
  • Apply the actual scope elevation in the Drop field and Calc.
  • Accept the new C1, Gun column and Elev are updated.
  • The Drag Coefficient Table will be automatically updated. [Manual]
  • Optionally, Save Gun and Done in the GunList.
Calculation
  • If a new Target Range is applied in the Target column, select Drag Coef Table in the Options menu and Done.
  • The ballistic coefficient C1 and the elevation Elev will be recalculated.
Interpolation

3.4 Example with overwritten zero distance

  • The Default zero distance can be overwritten with the Scopes module or the Settings Framework.
  • In this case, the Range Card will be automatically updated, NOT the AtragMx.
  • Open the Gun column, check and update the Zero Range and Done.
Default zero distance

4. Official Manual and Horus Videos

5. Dependencies

{% include dependencies_list.md component="atragmx" %}