1. Overview
1.1 AtragMx from Horus Vision
Horus ATragMX software considers atmospheric conditions, gun data, ammunition, range, speed and muzzle velocity to calculate precise aiming solutions with "come-up" results – and even accounts for Coriolis and spin drift effects. ATragMX, loaded on a handheld computer made by TDS Recon, is easy to use and lightning-fast. The Recon meets the rigorous MIL-STD-810F military standard for drops, vibration, humidity, altitude and extreme temperatures.
2. Requirement
- [Advanced Ballistics module enabled]({{ site.baseurl }}/wiki/feature/advanced-ballistics.html)
3. Usage
3.1 Opening the AtragMx
3.1.1 Interaction Menu
- Open the self interaction menu Ctrl + ⊞ Win
- Select
Equipment
- Select
Open AtragMx
3.1.2 Custom key
OPTIONS
/CONTROLS
/CONFIGURE ADDONS
/ACE3 Equipment
3.1.3 Inventory
3.2 Example with M14 and default 7.62mm 20Rnd Mag
Start of the mission:
- Open the [Range Card]({{ site.baseurl }}/wiki/feature/rangecard.html) and check the cartridge, the zeroed distance, the rifle twist, the muzzle velocity at 15°C and the bore height.
- Open the AtragMx and the
Atmsphr
column, selectDefault
andDone
. [Manual] Open Gun
the 7.62x51mm M80 in theGunList
. [Manual]- Select
E
(English unit) at the top right. [Manual] - Open the
Gun
column, check and update theBore
, theRifle Twist
andDone
. - Select
M
(Metric unit) at the top right. - Open the
Gun
column, check and update theMuzzle Velocity
, theZero Range
andDone
. - The Muzzle Velocity Table will be automatically updated. [Manual]
- (Must be edited manually for specific cartridges according with the range card)
- Optionally,
Save Gun
andDone
in theGunList
.
In position:
- Update the
Atmsphr
column with the [Kestrel 4500]({{ site.baseurl }}/wiki/feature/kestrel4500.html) andDone
. - Check the new
Muzzle Velocity
in theGun
column. - Update the
Target
column (the [wind arrow]({{ site.baseurl }}/wiki/feature/weather.html) will also help). [1] [2] [3] [4] - The latitude for all common maps can be found in the ACE3 Github.
- Apply the vertical and horizontal elevations on the [scope]({{ site.baseurl }}/wiki/feature/scopes.html).
- Control the breath and press.
3.3 Example with Truing tool
Start of the mission:
- Select
Drag Coef Table
in theOptions
menu. - Add the
ZR
and theC1
(Gun
column) in the table andDone
.
In position:
- Open the
Truing Drop
in theOptions
menu. [Manual] - Add the actual
Target Range
in theSUPER
column andCalc
. - Add the same
Target Range
in theSUB
column andCalc
. - Apply the actual scope elevation in the
Drop
field andCalc
. Accept
the newC1
,Gun
column andElev
are updated.- The Drag Coefficient Table will be automatically updated. [Manual]
- Optionally,
Save Gun
andDone
in theGunList
.
- If a new
Target Range
is applied in theTarget
column, selectDrag Coef Table
in theOptions
menu andDone
. - The ballistic coefficient
C1
and the elevationElev
will be recalculated.
3.4 Example with overwritten zero distance
- The
Default zero distance
can be overwritten with the [Scopes module]({{ site.baseurl }}/wiki/feature/scopes.html) or the [Settings Framework]({{ site.baseurl }}/wiki/framework/settings-framework.html). - In this case, the [Range Card]({{ site.baseurl }}/wiki/feature/rangecard.html) will be automatically updated, NOT the AtragMx.
- Open the AtragMx and the
Atmsphr
column, selectDefault
andDone
. [Manual] - Open the
Gun
column, check and update theZero Range
andDone
.
3.5 Example with Add New Gun
in GunList
- Open the [Range Card]({{ site.baseurl }}/wiki/feature/rangecard.html) and check the cartridge, the caliber, the bullet weight and the muzzle velocities.
- Open the AtragMx and the
Atmsphr
column, selectDefault
andDone
. [Manual] - Select
Add New Gun
in theGunList
. [Manual] - Add a
New Gun Name
andOpen Gun
. - Select
E
(English unit) at the top right. [Manual] - Open the
Gun
column, check and update theBullet Weight (grains)
, theBullet Diam (inches)
andDone
. - Select
M
(Metric unit) at the top right. - Open the
Muz Vel Table
in theOptions
menu or click onMV
in theGun
column. - Edit manually the
Muzzle Velocity Table
according with theRange card
andDone
. [Manual] - The
C1 coefficient
of the bullet can be found, for example, in the Eden EditorConfig Viewer
:
configfile >> "CfgAmmo" >> "Range card cartridge" >> "ACE_ballisticCoefficients"
configfile >> "CfgAmmo" >> "Range card cartridge" >> "ACE_dragModel"
- The AtragMx accepts only G1 ballistic coefficient.
- G7 ballistic coefficient can be converted, for example, with the online JBM Ballistics Calculators.
- Optionally,
Save Gun
andDone
in theGunList
.
4. Official Manual and Horus Videos
- [Official Manual]({{ site.ace.githubUrl }}/blob/master/extras/manual_Horus_ATrag-v385.pdf)
- Horus video part1
- Horus video part2
5. Dependencies
{% include dependencies_list.md component="atragmx" %}