1. Overview

1.1 AtragMx from Horus Vision

Horus ATragMX software considers atmospheric conditions, gun data, ammunition, range, speed and muzzle velocity to calculate precise aiming solutions with "come-up" results and even accounts for Coriolis and spin drift effects. ATragMX, loaded on a handheld computer made by TDS Recon, is easy to use and lightning-fast. The Recon meets the rigorous MIL-STD-810F military standard for drops, vibration, humidity, altitude and extreme temperatures.

2. Usage

2.1 Example with M14 and default 7.62mm 20Rnd Mag

Start of the mission:

  • Open the Range Card and check the cartridge, the zeroed distance, the rifle twist, the muzzle velocity at 15°C and the bore height.
RangeCard
  • Open the AtragMx and the Atmsphr column, select Default and Done. (cf manual, p 15)
  • Open Gun the 7.62x51mm M80 in the GunList. (cf manual, p 25)
  • Select E (English unit) at the top right. (cf manual, p 10)
  • Open the Gun column, check and update the Bore, the Rifle Twist and Done.
  • Select M (Metric unit) at the top right.
  • Open the Gun column, check and update the Muzzle Velocity, the Zero Range and Done.
  • The Muzzle Velocity Table will be automatically updated. (cf manual, p 22)
  • Optionally, Save Gun and Done in the GunList.

In position:

  • Update the Atmsphr column with the Kestrel and Done. (cf manual, p 15)
  • Check the new Muzzle Velocity in the Gun column.
  • Update the Target column. (cf manual, p 16, 30, 32, 33)
  • Apply the vertical and horizontal elevations on the scope.
  • Control the breath and press.

2.2 Example with Truing tool

Start of the mission:

  • Select Drag Coef Table in the Options menu. (cf manual, p 22)
  • Add the ZR and the C1 (Gun column) in the table and Done.

In position:

  • Open the Truing Drop in the Options menu. (cf manual, p 23)
  • Add the actual Target Range in the SUPER column and Calc.
  • Add the same Target Range in the SUB column and Calc.
  • Apply the actual scope elevation in the Drop field and Calc.
  • Accept the new C1, Gun column and Elev are updated.
  • The Drag Coefficient Table will be automatically updated.
  • Optionally, Save Gun and Done in the GunList.
Calculation
  • If a new Target Range is applied in the Target column, select Drag Coef Table in the Options menu and Done.
  • The ballistic coefficient C1 and the elevation Elev will be recalculated.
Interpolation

2.3 Example with overwritten zero distance

  • The Default zero distance can be overwritten with the Scopes module or the serverconfig.hpp.
  • In this case, the Range Card will be automatically updated, NOT the AtragMx.
  • Open the Gun column, check and update the Zero Range and Done.
Default zero distance