mirror of
https://github.com/acemod/ACE3.git
synced 2024-08-30 18:23:18 +00:00
a5cb451f76
* Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Update atragmx.md * Add files via upload * Update atragmx.md * Update atragmx.md * Update atragmx.md
3.1 KiB
3.1 KiB
layout | title | description | group | category | parent | mod | version | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
wiki | ATragMX | Handheld ballistics calculator. | feature | equipment | wiki | ace |
|
1. Overview
1.1 AtragMx from Horus Vision
Horus ATragMX software considers atmospheric conditions, gun data, ammunition, range, speed and muzzle velocity to calculate precise aiming solutions with "come-up" results – and even accounts for Coriolis and spin drift effects. ATragMX, loaded on a handheld computer made by TDS Recon, is easy to use and lightning-fast. The Recon meets the rigorous MIL-STD-810F military standard for drops, vibration, humidity, altitude and extreme temperatures.
2. Usage
2.1 Example with M14 and default 7.62mm 20Rnd Mag
Start of the mission:
- Open the Range Card and check the cartridge, the zeroed distance, the rifle twist, the Muzzle Velocity at 15°C and the Bore Height at the end.
- Open the AtragMx and the
Atmsphr
column, selectDefault
andDone
. Open Gun
the 7.62x51mm M80 in theGunList
.- Select
E
(English unit) at the top right. - Open the
Gun
column, check and update theBore
, theRifle Twist
andDone
. - Select
M
(Metric unit) at the top right. - Open the
Gun
column, check and update theMuzzle Velocity
, theZero Range
andDone
. - The Muzzle Velocity Table will be automatically updated.
- Optionally,
Save Gun
andDone
in theGunList
.
In position:
- Update the
Atmsphr
column with the Kestrel andDone
(Check the new Muzzle Velocity in theGun
column). - Update the
Target
column. - Apply the vertical and horizontal elevations on the scope.
- Control the breath and press.
2.2 Example with Truing tool
Start of the mission:
- Select
Drag Coef Table
in theOptions
menu. - Add the
ZR
and theC1
(Gun
column) in the table andDone
.
In position:
- Open the
Truing Drop
in theOptions
menu. - Add the actual
Target Range
in theSUPER
column andCalc
. - Add the same
Target Range
in theSUB
column andCalc
. - Apply the actual scope elevation in the
Drop
field andCalc
. Accept
the newC1
,Gun
column andElev
are updated.- The Drag Coefficient Table will be automatically updated.
- Optionally,
Save Gun
andDone
in theGunList
.
- If a new
Target Range
is applied in theTarget
column, selectDrag Coef Table
in theOptions
menu andDone
. - The ballistic coefficient
C1
and the elevationElev
will be recalculated.
3. Official Manual and Horus Videos
4. Dependencies
{% include dependencies_list.md component="atragmx" %}