local comms = require("scada-common.comms")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local util = require("scada-common.util")
local apisessions = require("coordinator.apisessions")
local iocontrol = require("coordinator.iocontrol")
2022-07-19 18:03:02 +00:00
local dialog = require("coordinator.ui.dialog")
2022-06-15 19:35:34 +00:00
local coordinator = {}
local print = util.print
local println = util.println
local print_ts = util.print_ts
local println_ts = util.println_ts
2022-06-15 19:35:34 +00:00
local PROTOCOLS = comms.PROTOCOLS
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local SCADA_CRDN_TYPES = comms.SCADA_CRDN_TYPES
2022-05-10 21:09:02 +00:00
2022-06-15 19:35:34 +00:00
-- request the user to select a monitor
---@param names table available monitors
local function ask_monitor(names)
println("available monitors:")
for i = 1, #names do
print(" " .. names[i])
end
println("")
println("select a monitor or type c to cancel")
local iface = dialog.ask_options(names, "c")
if iface ~= false and iface ~= nil then
util.filter_table(names, function (x) return x ~= iface end)
end
return iface
end
2022-06-15 19:35:34 +00:00
-- configure monitor layout
---@param num_units integer number of units expected
function coordinator.configure_monitors(num_units)
---@class monitors_struct
local monitors = {
primary = nil,
primary_name = "",
unit_displays = {},
unit_name_map = {}
}
local monitors_avail = ppm.get_monitor_list()
local names = {}
-- get all interface names
for iface, _ in pairs(monitors_avail) do
table.insert(names, iface)
end
-- we need a certain number of monitors (1 per unit + 1 primary display)
if #names ~= num_units + 1 then
println("not enough monitors connected (need " .. num_units + 1 .. ")")
log.warning("insufficient monitors present (need " .. num_units + 1 .. ")")
return false
end
-- attempt to load settings
settings.load("/coord.settings")
---------------------
-- PRIMARY DISPLAY --
---------------------
local iface_primary_display = settings.get("PRIMARY_DISPLAY")
if not util.table_contains(names, iface_primary_display) then
println("primary display is not connected")
local response = dialog.ask_y_n("would you like to change it", true)
if response == false then return false end
iface_primary_display = nil
end
while iface_primary_display == nil and #names > 0 do
-- lets get a monitor
iface_primary_display = ask_monitor(names)
end
if iface_primary_display == false then return false end
settings.set("PRIMARY_DISPLAY", iface_primary_display)
util.filter_table(names, function (x) return x ~= iface_primary_display end)
monitors.primary = ppm.get_periph(iface_primary_display)
monitors.primary_name = iface_primary_display
-------------------
-- UNIT DISPLAYS --
-------------------
local unit_displays = settings.get("UNIT_DISPLAYS")
if unit_displays == nil then
unit_displays = {}
for i = 1, num_units do
local display = nil
while display == nil and #names > 0 do
-- lets get a monitor
println("please select monitor for unit " .. i)
display = ask_monitor(names)
end
if display == false then return false end
unit_displays[i] = display
end
else
-- make sure all displays are connected
for i = 1, num_units do
---@diagnostic disable-next-line: need-check-nil
local display = unit_displays[i]
if not util.table_contains(names, display) then
local response = dialog.ask_y_n("unit display " .. i .. " is not connected, would you like to change it?", true)
if response == false then return false end
display = nil
end
while display == nil and #names > 0 do
-- lets get a monitor
display = ask_monitor(names)
end
if display == false then return false end
unit_displays[i] = display
end
end
settings.set("UNIT_DISPLAYS", unit_displays)
settings.save("/coord.settings")
for i = 1, #unit_displays do
monitors.unit_displays[i] = ppm.get_periph(unit_displays[i])
monitors.unit_name_map[i] = unit_displays[i]
end
return true, monitors
end
2022-07-05 15:18:26 +00:00
-- dmesg print wrapper
---@param message string message
---@param dmesg_tag string tag
2022-07-06 03:48:01 +00:00
---@param working? boolean to use dmesg_working
---@return function? update, function? done
local function log_dmesg(message, dmesg_tag, working)
2022-07-05 15:18:26 +00:00
local colors = {
GRAPHICS = colors.green,
SYSTEM = colors.cyan,
BOOT = colors.blue,
COMMS = colors.purple
}
2022-07-06 03:48:01 +00:00
if working then
return log.dmesg_working(message, dmesg_tag, colors[dmesg_tag])
else
log.dmesg(message, dmesg_tag, colors[dmesg_tag])
end
2022-07-05 15:18:26 +00:00
end
function coordinator.log_graphics(message) log_dmesg(message, "GRAPHICS") end
function coordinator.log_sys(message) log_dmesg(message, "SYSTEM") end
function coordinator.log_boot(message) log_dmesg(message, "BOOT") end
function coordinator.log_comms(message) log_dmesg(message, "COMMS") end
2022-07-06 03:48:01 +00:00
---@param message string
---@return function update, function done
function coordinator.log_comms_connecting(message) return log_dmesg(message, "COMMS", true) end
-- coordinator communications
---@param version string
---@param modem table
---@param sv_port integer
---@param sv_listen integer
---@param api_listen integer
---@param sv_watchdog watchdog
2022-07-05 15:18:26 +00:00
function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, sv_watchdog)
local self = {
2022-07-06 03:48:01 +00:00
sv_linked = false,
sv_seq_num = 0,
sv_r_seq_num = nil,
2022-06-15 19:35:34 +00:00
modem = modem,
connected = false
}
2022-06-15 19:35:34 +00:00
---@class coord_comms
local public = {}
-- PRIVATE FUNCTIONS --
-- open all channels
local function _open_channels()
if not self.modem.isOpen(sv_listen) then
self.modem.open(sv_listen)
end
if not self.modem.isOpen(api_listen) then
self.modem.open(api_listen)
end
end
-- open at construct time
_open_channels()
-- send a packet to the supervisor
---@param msg_type SCADA_MGMT_TYPES|SCADA_CRDN_TYPES
---@param msg table
local function _send_sv(protocol, msg_type, msg)
2022-06-15 19:35:34 +00:00
local s_pkt = comms.scada_packet()
local pkt = nil ---@type mgmt_packet|crdn_packet
if protocol == PROTOCOLS.SCADA_MGMT then
pkt = comms.mgmt_packet()
elseif protocol == PROTOCOLS.SCADA_CRDN then
pkt = comms.crdn_packet()
else
return
end
2022-06-15 19:35:34 +00:00
pkt.make(msg_type, msg)
s_pkt.make(self.sv_seq_num, protocol, pkt.raw_sendable())
2022-06-15 19:35:34 +00:00
self.modem.transmit(sv_port, sv_listen, s_pkt.raw_sendable())
self.sv_seq_num = self.sv_seq_num + 1
2022-06-15 19:35:34 +00:00
end
-- attempt connection establishment
local function _send_establish()
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.ESTABLISH, { version })
end
-- keep alive ack
---@param srv_time integer
local function _send_keep_alive_ack(srv_time)
_send_sv(PROTOCOLS.SCADA_MGMT, SCADA_MGMT_TYPES.KEEP_ALIVE, { srv_time, util.time() })
end
2022-06-15 19:35:34 +00:00
-- PUBLIC FUNCTIONS --
-- reconnect a newly connected modem
---@param modem table
---@diagnostic disable-next-line: redefined-local
function public.reconnect_modem(modem)
self.modem = modem
_open_channels()
end
-- close the connection to the server
function public.close()
sv_watchdog.cancel()
_send_sv(PROTOCOLS.SCADA_MGMT, SCADA_MGMT_TYPES.CLOSE, {})
end
2022-07-06 03:48:01 +00:00
-- attempt to connect to the subervisor
---@param timeout_s number timeout in seconds
---@param tick_dmesg_waiting function callback to tick dmesg waiting
---@param task_done function callback to show done on dmesg
---@return boolean sv_linked true if connected, false otherwise
--- EVENT_CONSUMER: this function consumes events
function public.sv_connect(timeout_s, tick_dmesg_waiting, task_done)
local clock = util.new_clock(1)
local start = util.time_s()
local terminated = false
_send_establish()
2022-07-06 03:48:01 +00:00
clock.start()
while (util.time_s() - start) < timeout_s and not self.sv_linked do
local event, p1, p2, p3, p4, p5 = util.pull_event()
2022-07-06 03:48:01 +00:00
if event == "timer" and clock.is_clock(p1) then
-- timed out attempt, try again
tick_dmesg_waiting(math.max(0, timeout_s - (util.time_s() - start)))
_send_establish()
2022-07-06 03:48:01 +00:00
clock.start()
elseif event == "modem_message" then
-- handle message
local packet = public.parse_packet(p1, p2, p3, p4, p5)
if packet ~= nil and packet.type == SCADA_CRDN_TYPES.ESTABLISH then
2022-07-06 03:48:01 +00:00
public.handle_packet(packet)
end
elseif event == "terminate" then
terminated = true
break
end
end
2022-07-06 03:49:48 +00:00
task_done(self.sv_linked)
if terminated then
coordinator.log_comms("supervisor connection attempt cancelled by user")
2022-07-06 03:48:01 +00:00
end
return self.sv_linked
end
2022-06-15 19:35:34 +00:00
-- parse a packet
---@param side string
---@param sender integer
---@param reply_to integer
---@param message any
---@param distance integer
---@return mgmt_frame|crdn_frame|capi_frame|nil packet
2022-06-15 19:35:34 +00:00
function public.parse_packet(side, sender, reply_to, message, distance)
local pkt = nil
local s_pkt = comms.scada_packet()
-- parse packet as generic SCADA packet
s_pkt.receive(side, sender, reply_to, message, distance)
if s_pkt.is_valid() then
-- get as SCADA management packet
if s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
end
-- get as coordinator packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_CRDN then
local crdn_pkt = comms.crdn_packet()
if crdn_pkt.decode(s_pkt) then
pkt = crdn_pkt.get()
2022-06-15 19:35:34 +00:00
end
-- get as coordinator API packet
elseif s_pkt.protocol() == PROTOCOLS.COORD_API then
local capi_pkt = comms.capi_packet()
if capi_pkt.decode(s_pkt) then
pkt = capi_pkt.get()
end
else
log.debug("attempted parse of illegal packet type " .. s_pkt.protocol(), true)
end
end
return pkt
end
-- handle a packet
---@param packet mgmt_frame|crdn_frame|capi_frame
2022-06-15 19:35:34 +00:00
function public.handle_packet(packet)
if packet ~= nil then
local protocol = packet.scada_frame.protocol()
if protocol == PROTOCOLS.COORD_API then
apisessions.handle_packet(packet)
else
-- check sequence number
if self.sv_r_seq_num == nil then
self.sv_r_seq_num = packet.scada_frame.seq_num()
elseif self.connected and self.sv_r_seq_num >= packet.scada_frame.seq_num() then
log.warning("sequence out-of-order: last = " .. self.sv_r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
2022-06-15 19:35:34 +00:00
else
self.sv_r_seq_num = packet.scada_frame.seq_num()
2022-06-15 19:35:34 +00:00
end
-- feed watchdog on valid sequence number
sv_watchdog.feed()
-- handle packet
if protocol == PROTOCOLS.SCADA_CRDN then
if packet.type == SCADA_CRDN_TYPES.ESTABLISH then
2022-07-06 03:48:01 +00:00
-- connection with supervisor established
if packet.length > 1 then
-- get configuration
---@class facility_conf
local conf = {
num_units = packet.data[1],
defs = {} -- boilers and turbines
}
if (packet.length - 1) == (conf.num_units * 2) then
-- record sequence of pairs of [#boilers, #turbines] per unit
for i = 2, packet.length do
table.insert(conf.defs, packet.data[i])
end
-- init io controller
iocontrol.init(conf)
self.sv_linked = true
2022-07-06 03:48:01 +00:00
else
log.debug("supervisor conn establish packet length mismatch")
end
else
log.debug("supervisor conn establish packet length mismatch")
end
elseif packet.type == SCADA_CRDN_TYPES.STRUCT_BUILDS then
-- record builds
if iocontrol.record_builds(packet.data) then
-- acknowledge receipt of builds
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.STRUCT_BUILDS, {})
else
log.error("received invalid build packet")
end
elseif packet.type == SCADA_CRDN_TYPES.UNIT_STATUSES then
-- update statuses
if not iocontrol.update_statuses(packet.data) then
log.error("received invalid unit statuses packet")
end
elseif packet.type == SCADA_CRDN_TYPES.COMMAND_UNIT then
elseif packet.type == SCADA_CRDN_TYPES.ALARM then
else
log.warning("received unknown SCADA_CRDN packet type " .. packet.type)
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
if packet.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
local timestamp = packet.data[1]
local trip_time = util.time() - timestamp
if trip_time > 500 then
log.warning("coord KEEP_ALIVE trip time > 500ms (" .. trip_time .. "ms)")
end
-- log.debug("coord RTT = " .. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
else
log.debug("SCADA keep alive packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPES.CLOSE then
-- handle session close
sv_watchdog.cancel()
self.sv_linked = false
println_ts("server connection closed by remote host")
log.warning("server connection closed by remote host")
else
log.warning("received unknown SCADA_MGMT packet type " .. packet.type)
end
2022-06-15 19:35:34 +00:00
else
-- should be unreachable assuming packet is from parse_packet()
log.error("illegal packet type " .. protocol, true)
2022-06-15 19:35:34 +00:00
end
end
end
end
-- check if the coordinator is still linked to the supervisor
function public.is_linked() return self.sv_linked end
2022-06-15 19:35:34 +00:00
return public
end
2022-05-10 21:09:02 +00:00
return coordinator